Incorporation of a minicomputer as an intelligent terminal in a treatment planning system.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Mohan.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Pancreatic B-cell function in relation to diabetic retinopathy was studied in 195 NIDDM patients with long-standing diabetes. Background diabetic retinopathy (BDR) was present in 95 (48.7%) and proliferative retinopathy (PDR) in 17 (8.7%) of the subjects. There was no significant difference between the BDR, PDR, and non-retinopathy groups with respect to age, age at diagnosis of diabetes and HbA1 values. Mean duration of diabetes was higher in the PDR group (p less than 0.05). Serum C-peptide values showed no correlation with the presence of retinopathy or with the duration of diabetes. The C-peptide values were widely scattered in patients with BDR and PDR showing no association between pancreatic B-cell reserve and occurrence or severity of retinopathy in NIDDM patients. Thus, decreased pancreatic B-cell reserve does not appear to be a risk factor for diabetic retinopathy in NIDDM patients.
The use of a compact, mobile, relatively inexpensive electromechanical patient-contouring mechanism is described. The system utilizes a Numonics Model 224 graphics digitizer suspended over the patient. The digital X and Y coordinates of the patient contour in either of multiple, parallel transverse, or sagittal planes are inherently accurate to within +/-0.25 mm over a total reading are of 60X90 cm. Display features include the interface to an analog 11-in.X17-in. X-Y plotter with a variable scale-down factor for those contours which would otherwise be larger than the plotting surface. The system is easy to use and may also be readily interfaced for on-line entry of patient contours to calculator- or minicomputer-based treatment-planning systems.
The contribution made by contaminating electrons present in a clinical photon beam to the buildup dose in a polystyrene phantom has been calculated and compared to measurements. A Monte Carlo technique was employed. The calculation was divided into two parts. First, the accelerator treatment head was simulated in detail using the EGS-PEGS electromagnetic shower code. Then, information obtained from these calculations was used to compute dose curves in a polystyrene phantom. Two cases were considered, one in which both electrons and photons were incident upon the phantom, and another in which electrons were eliminated from the incident beam. Results of these calculations agree with recent experimental findings. A decrease in buildup dose as well as a shift in dmax was observed when electrons were eliminated from the beam.
A detailed Monte Carlo approach has been employed to investigate the sources of electron contamination for the 25-MV photon beam generated by Varian's Clinac-35. Three sources of contamination were examined: (a) the flattening filter and beam monitor chamber, (b) the fixed primary collimators downstream from the monitor chamber and the adjustable photon jaws, and (c) the air volume separating the treatment head from the observation point. Five source-to-surface distances (SSDs) were considered for a single field size, 28 cm in diameter at 80 cm SSD. It was found that for small SSDs (80-100 cm), the dominant sources of electron contamination were the flattening filter and the beam monitor chamber which accounted for 70% of the unwanted electrons. Thirteen percent of the remaining electrons originated in the downstream primary collimators and the photon jaws, and 17% were produced in air. At larger SSDs, the fraction of unwanted electrons originating in air increased. At 400 cm SSD, 61% of the contaminating electrons present in the beam were produced in air, 34% originated in the flattening filter and beam monitor chamber, and 5% were due to interactions in the fixed collimators downstream from the monitor chamber and the adjustable photon jaws. These calculated results are substantiated by recent experiments.
The technique of separating dose into primary and scatter components for calculating photon dose distributions is widely used. The primary and scatter dose models ignore ignore the fact that electrons have a finite range. This may be a good approximation for 60Co photons but not for higher energies. For the latter, the range of electrons may be several centimeters in soft tissue and even longer in lungs and will lead to errors in computed dose in regions where electronic equilibrium does not exist. Ignoring the finite range of electrons will affect dose at points such as those near the beam boundaries, near inhomogeneity boundaries, and at bone-soft-tissue interfaces. Other possible problems associated with the definition and use of "primary" and "scatter" dose in dose distribution calculations result from extrapolation of measured data to obtain data for zero and very large field sizes and from the use of these quantities, which are defined for central axis, for points at large distances from the central axis. This paper examines the limits of the validity of these assumptions.
For accurate three-dimensional treatment planning, new models of dose calculations are being developed which require the knowledge of the energy spectra and angular distributions of the photons incident on the surface of the patient. Knowledge of the spectra is also useful in other applications, including the design of filters and beam modifying devices and determination of factors to convert ionization chamber measurements to dose. We have used Monte Carlo code (EGS) to compute photon spectra for a number of different linear accelerators. Both the target and the flattening filter have been accurately modeled. We find the mean photon energy to have a value lower than the generally perceived value of one-third the maximum energy. As expected, the spectra become softer as the distance from the central axis increases. Verification of the spectra is performed by computing dose distributions and half-value layers in water using the calculated spectra and comparing the results with measured data. We also examined the angular distributions of photons incident on the surface of the phantom. In currently used models of dose computations, it is assumed that the angular distribution of photons with respect to fan lines emanating from the source is negligible. Although the angular spread of photons with respect to the incident direction has been found to be small, its contribution to the diffuseness of the beam boundaries is significant.
A new method is proposed for computing the off-center ratios (OCR's) in three-dimensional dose calculations. For an open field, the OCR at a point is computed as the product of the primary OCR (POCR) and the boundary factors (BF's). The POCR describes the beam profile for an infinite field, that is, without the effect of the collimators. It is defined as the ratio of the dose at a point off the central ray to the dose at the point on the central ray at the same depth for an infinite field. The POCR is a function of radial distance from the beam central ray and depth. The BF describes the shape of the beam in the neighborhood of the field boundary defined by the collimators. It is defined as the ratio of the OCR at a point for a finite field to the OCR at the same point for an infinite field. The BF is a function of distance from the field boundary, depth, and field size. For a wedged field, we assume that the boundary factors remain the same as for open fields but the POCR's are altered. The changes in beam profiles are described by a factor called the wedge profile factor (WPF), defined as the ratio of the dose at a point for the largest wedged field to the dose at the same point for an open field of the same field size. The WPF is a function of lateral distance from the beam central plane and depth. Calculated OCR's using this new method are in agreement with the measured data along both the transverse and the diagonal directions of the field.
Differential pencil beam (DPB) is defined as the dose distribution relative to the position of the first collision, per unit collision density, for a monoenergetic pencil beam of photons in an infinite homogeneous medium of unit density. We have generated DPB dose distribution tables for a number of photon energies in water using the Monte Carlo method. The three-dimensional (3D) nature of the transport of photons and electrons is automatically incorporated in DPB dose distributions. Dose is computed by evaluating 3D integrals of DPB dose. The DPB dose computation model has been applied to calculate dose distributions for 60Co and accelerator beams. Calculations for the latter are performed using energy spectra generated with the Monte Carlo program. To predict dose distributions near the beam boundaries defined by the collimation system as well as blocks, we utilize the angular distribution of incident photons. Inhomogeneities are taken into account by attenuating the primary photon fluence exponentially utilizing the average total linear attenuation coefficient of intervening tissue, by multiplying photon fluence by the linear attenuation coefficient to yield the number of collisions in the scattering volume, and by scaling the path between the scattering volume element and the computation point by an effective density.
Graphical displays of three-dimensional dose distribution data are often too complex to be easily assimilated and interpreted for the evaluation of radiation treatment plans. Histograms showing dose versus volume are convenient and useful tools for summarizing dose distribution information throughout the entire volume of a given anatomic structure. They can quickly highlight characteristics such as dose uniformity and hot and cold spots, and can be used to produce statistics including tumor control and normal tissue complication probabilities. To obtain a dose volume histogram for a given structure, it may be necessary to examine its spatial relationships with neighboring structures. They may overlap, be completely disjoint, or one may be contained within another. To resolve potential ambiguities, a procedure has been developed that assigns hierarchies to anatomical structures for the purpose of histogram calculation. The hierarchy assigned to each structure is used to determine the structure within which a given dose matrix point is considered to lie. In this manner, regions of structure intersection are assigned to one object or another, and dose volume histograms can be calculated for each structure separately. From this framework, addition and subtraction of histograms can also be performed. Details of the algorithm are presented along with an example using patient data.
In three-dimensional radiation treatment planning, essentially all fields are irregular and compensated. Consequently, it is important to predict accurately dose for such fields to ensure adequate coverage of the target region and sparing of healthy tissues. Traditional approaches, namely, those involving scatter integration and extended source and those utilizing negatively weighted fields, are inaccurate, especially near the boundaries defined by blocks and collimators. In the method presented in this paper, dose distributions for arbitrarily shaped beams are calculated by two-dimensional convolution of the relative primary photon fluence distributions and kernels representing the cross-sectional profiles of a pencil beam at a series of depths. The pencil beam dose distributions are computed, once and for all, with the Monte Carlo method for photon energy spectrum for each treatment machine. The finite size of the source, which is important for cobalt machines, is also taken into account using convolution of the source with the relative primary fluence distribution. Convolutions are performed using fast Fourier transforms on an array processor. Results of calculations are in excellent agreement with measured data. While no data are presented for fields modified by compensators, the method of calculation should apply at least as well for such fields since the variations in fluence distribution for compensated fields are not as sharp as for points near the block boundaries.
We have used the Stanford Electron Gamma Shower (EGS) Monte Carlo code to compute photon spectra from an AECL Theratron 780 cobalt-60 unit. Particular attention has been paid to the careful modeling of the geometry and material construction of the cobalt-60 source capsule, source housing, and collimator assembly. From our simulation, we conclude that the observed increase in output of the machine with increasing field size is caused by scattered photons from the primary definer and the adjustable collimator. We have also used the generated photon spectra as input to a pencil beam model to calculate the tissue-air ratios in water and compared it to a model which uses a monochromatic photon energy of 1.25 MeV.
Asymmetric fields defined by independent jaws can be used to split a beam or to match adjacent fields. We have extended a method originally developed for symmetric fields to calculate the dose for asymmetric fields. The dose to a point is computed as the product of the tissue maximum ratio (TMR), the off center ratio (OCR), and the inverse square factor. The TMR is computed from the measured central axis depth doses for symmetric fields. The OCR is obtained by multiplying the primary OCR (POCR) and the boundary factors (BF's) for the four jaws. The POCR's and BF's were derived from measured beam profiles, which include the effect of off-axis beam quality variations. Using this method, the beam profiles and isodose distributions for asymmetric fields of a 6-MV accelerator were calculated and compared with the measured data. The agreement is within experimental errors both in the penumbra region and along the central ray of the asymmetric field.
Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-dimensional step function whose shape corresponds to the applicator aperture. Two different approaches to obtain angular spread or the equivalent spatial spread are investigated. In the first method, the pencil beam angular spread is assumed to be Gaussian in shape. The angular spread constants (sigma theta) are then obtained from the slopes of measured intensity profiles. In the second method, the angular spread, in the form of an array of numerical values, is obtained by the deconvolution of measured intensity profiles. After obtaining the angular spread, the calculation for convolution is done in a number of parallel planes normal to the central axis at various distances from the electron collimator. Intensity at any arbitrary point in space is computed by interpolating between intensity distributions in adjacent planes on either side of the point. The effects of variations in angular spread as a function of field size for two treatment machines, one with a scanned electron beam and the other with a scattering foil, have been studied. The consequences of assuming angular spread to be of Gaussian shape are also examined. The electron intensity calculation techniques described in this paper apply primarily to methods of dose calculations that employ pencil beams generated using Monte Carlo simulations.
A method has been developed to extract pencil beam kernels from measured broad beam profiles. In theory, the convolution of a symmetric kernel with a step function will yield a function that is symmetric about the inflection point. Conversely, by deconvolution, the kernel may be extracted from a measured distribution. In practice, however, due to the uncertainties and errors associated with the measurements and due to the singularities produced in the fast Fourier transforms employed in the deconvolution process, the kernels thus obtained and the dose distributions calculated therefrom, often exhibit erratic fluctuations. We propose a method that transforms measured profiles to new, modified distributions so that they satisfy the theoretical symmetry condition. The resultant kernel from the deconvolution is then free of fluctuations. We applied this method to compute photon and electron dose distributions at various depths in water and electron fluence distributions in air. The agreement between measured and computed profiles is within 1% in dose or 1 mm in distance in high dose gradient regions.