Search PubMed⌕ Search

Biomedical subjects

R Mohan

Publications and source records attributed to R Mohan.

At least 199 records · Page 11Linked to original sources

Epidemiologic and laboratory observations of Chlamydia psittaci infection in pet birds.

Psittacosis was diagnosed in 13 (24%) of 55 pet bird submissions in the first 3 months of 1983, compared with 18 (17%) of 103 in 1982, 4 (4.6%) of 87 in 1981, and 3 (8%) of 36 in 1980. The numbers and types of birds in which psittacosis was diagnosed were 2 of 47 budgerigars, 8 of 45 cockatiels , 3 of 11 small parrots ( lovebirds , conures ), 20 of 116 medium-sized parrots (African Grays, Amazons ), 2 of 21 macaws , and 3 of 21 cockatoos . Thirty-nine percent of psittacosis-positive birds were received from pet bird owners, compared with 21% from pet shops, 18% from pet bird breeders and fanciers, and 13% from pet bird jobbers and retailers . Most frequently observed clinical signs were anorexia, weight loss, and diarrhea or yellowish droppings. Major gross lesions were splenohepatomegaly (77%), followed by enteritis (53%), sinusitis (47%), airsacculitis (37%), pneumonitis (23%), and pericarditis (10%). Regarding the 38 cases of confirmed psittacosis in pet birds since 1980, transmission of the disease to human beings was confirmed in 2 cases and suspected in 4 cases.

Adult↗

A computerized record and verify system for radiation treatments.

We have developed a general purpose, comprehensive, and highly reliable computerized Record and Verify System to detect and prevent mistakes in the delivery of external beam radiation therapy. This system helps prevent accidental delivery of dangerous dose, improves quality control, and provides invaluable record keeping and report generating capabilities. Currently, treatment machine and couch parameter settings of four different machines are monitored by the system and compared with prescribed values. The system inhibits a machine from being turned on if the settings do not agree with the prescribed values to within specified maximum permissible deviations. The system is user-friendly and provides useful, complete, and easily accessible data. We describe many aspects of the system including hardware, software, data, and operation, and we conclude with a brief discussion of clinical experience and preliminary data.

Computers↗

Standardization of therapy machine interface for treatment monitoring.

Computerized monitoring of radiation treatments is an effective tool in detecting and preventing errors in treatment delivery. Most manufacturers now supply optional treatment monitoring (Record and Verify) systems. These differ significantly in their features and are, in general, incompatible with each other. Based on our examination of four different commercial systems, we believe that these commercial and individualized systems are not adequate and are difficult to use. In a radiation therapy facility with more than one treatment machine, it is highly desirable, for a variety of reasons, that such a system be implemented on a central computer which monitors all machines. A centralized record and verify system which allows the storage of all data on a long term basis in an on-line common data base permits much easier access to individual patient data as well as useful data analysis and reports. Every patient's demographic, prescription and treatment data are then available on all treatment machines. This is particularly useful for cases in which a patient may be transferred from one machine to the other. Such a system is also easier to operate. The development of such a treatment monitoring system requires that the protocol of communication between the therapy machine and the computer, and the data describing therapy machine settings transmitted to the computer be standardized. We propose that every manufacturer supply an optional interface meeting this standard. A description of the proposed standard evolved in four years of our work in this field is given.

Computers↗

Electrokinetic properties of (Na+, K+)-ATPase vesicles as studied by laser Doppler spectroscopy.

The technique of laser Doppler electrophoresis was applied for the study of the surface charge properties of (NA+, K+)-ATPase containing microsomal vesicles derived from guinea-pig kidney. The influence of pH, the screening and binding of uni- and divalent cations and the binding of ATP show: (1) one net negative charge per protein unit with a pK = 3.9; (2) deviation from the Debye relation between surface potential and ionic strength for univalent cations, with no difference in the effect of Na+ and K+; (3) Mg2+ binds with an association constant of Ka = 1.1. 10(2) M-1 while ATP binds with an apparent Ka = 1.1.10(4) M-1 for 1 mM NaCl, 0.2 mM KCI, 0.1 mM MgCl2, 0.1 mM Tris-HCl2, 0.1 mM Tris-HCl (pH 7.3). The binding is weaker at higher Mg2+ concentrations. There is no ATP binding in the absence of Mg2+. In addition, the average vesicle size derived from the linewidth of the quasielastic light scattering spectrum is 203.7 +/- 15.2 nm. In the presence of ATP a reduction in size is observed.

Animals↗

Use of computerized tomography in dose calculations for radiation treatment planning.

The detailed anatomic information provided by CT scanners can be used to improve the accuracy of dose distribution calculations for radiation treatment planning. Commonly used methods for dose computations are described, with emphasis on their use with CT data, and measured data are presented to illustrate their relative merits. Modification of CT numbers to account for the difference in energies of diagnostic and therapeutic radiation is discussed. A description of a typical CT-based radiation treatment planning system is presented.

Humans↗

A method of correction for curvature and inhomogeneities in computer aided calculation of external beam radiation dose distributions.

This paper deals with the problem of finding the effective pathlength along a ray passing through a patient's outline and internal structure. The pathlength contributes to the correction applied for curvature and inhomogeneities in the computer-aided calculation of external beam radiation dose distributions. The pathlength is found by first determining the intersections of the ray with the contours defining the patient's body and the interior inhomogeneities. From these intersections the geometric length within each contour is obtained. This information is then employed in a treatment planning program for high energy gamma and X-rays and electrons, in which the radiation dose distribution is computed taking into account the actual inhomogeneous tissue structures. Other applications of the techniques described to problems in the field of radiation therapy are briefly discussed.

Computers↗

Oak poisoning of cattle in Ohio.

Fourteen cases of oak poisoning were diagnosed at the Ohio Veterinary Diagnostic Laboratory, Reynoldsburg, Oh, in the fall of 1976. The poisoning was attributed to ingestion of oak shrubs, oak leaves, and acorns. Clinical signs included anorexia, rumen atony, hemorrhagic diarrhea, subcutaneous edema, and abnormal renal function. Perirenal edema and hemorrhage, ascites, hydrothorax, and hemorrhagic enteritis were frequently encountered pathologic changes. Histologic examination of the kidney revealed multifocal necrosis of the proximal convoluted tubules, which is a characteristic feature of this type of poisoning.

Animals↗