Circadian responsiveness of the hypothalamic-pituitary axis.

Five healthy men 25-38 years old were subjected to simultaneous composite intravenous stimulation tests of insulin hypoglycemia (0.1 U/kg), thyrotropin-releasing hormone (TRH, 100 mug), and luteinizing hormone-releasing hormone (LHRH, 50 mug) at weekly intervals to study the circadian responsiveness of the hypothalamic-adenohypophyseal axis at 0600, 1200, 1800, and 0000 hours. Blood sugar (BS), LH, follicle-stimulating hormone, TSH, prolactin, cortisol (C), growth hormone, and testosterone (T) levels were estimated before and after the administration of drugs. Comparisons were made between basal and delta values (difference between basal and peak or nadir levels) at different tests. Significant circadian variations in BS, GH, C, and, to a lesser extent PRL, responses were observed 0600 h basal and delta BS values were the lowest, delta BS was highest at 0000 h accompanied by maximal hypoglycemic symptoms; the delta values of both C and GH were significantly higher at 0600 h and 0000 h; highest mean delta PRL was observed at 0600; at 1800 h the basal plasma PRL level was maximum but the delta PRL was lowest. Plasma TSH, LH, and FSH responses did not show significant circadian variations. These results suggest that circadian variations are evident when stimuli act through central or hypothalamic mechanisms; however, direct stimulation of the adenohypophysis resulted in indentical responses at different periods tested.

Adult↗

A specific, non-chromatographic radioimmunoassay for human plasma cortisol.

A radioimmunoassay technique has been developed for the measurement of cortisol in a single methylene chloride extract of human plasma without chromatography. The antiserum, obtained by immunizing rabbits with cortisol-3-carboxymethyl-oxime conjugated to bovine serum albumin, had a high affinity (KA = 1.8 X 10(9) 1/mole) and capacity (2.3 X 10(-6) moles/L undiluted serum) for cortisol. The minimum detectable amount determined at the lower 95% confidence limit of the buffer control tubes was 8.3 +/- 4.7 pg/tube and a log dose - logit response standard curve was linear between 20 pg and 20 ng/tube. The antiserum was highly specific for cortisol with only corticosterone, cortisone, 11-deoxycortisol and 21-deoxycortisol showing significant cross-reaction (12.4, 6.6, 3.8 and 3.7%, respectively). The cross-reaction for the other tested naturally occurring and synthetic steroids did not exceed 1%. Regression analysis of cortisol concentration estimates obtained on 20 samples before and after Sephadex LH-20 column chromatography gave a coefficient of correlation (r) of 0.995 and a regression coefficient (b) of 1.04. Recovery of cortisol added to plasma samples was quantitative. The intra-assay error was 8.5% and the inter-assay error averaged 5.7%. The method is simple requiring a single solvent extraction of plasma, therefore permitting large numbers of samples to be handled efficiently by a single technician.

Cross Reactions↗

Erythropoiesis and erythropoietin in hypo- and hyperthyroidism.

Qualitative and quantitative studies of erythropoiesis in 23 patients with hypothyroidism and 21 patients with hyperthryoidism included routine hematologic evaluation, bone marrow morphology, status of serum iron, B12 and folate red blood cell mass and plasma volume by radioisotope methods, erythrokinetics and radiobioassay of plasma erythropoietin. A majority of patients with the hypothyroid state had significant reduction in red blood cell mas per kg of body weight. The presence of anemia in many of these patients was not evident from hemoglobin and hematocrit values due to concomitant reduction of plasma volume. The erythrokinetic data in hypothyroid patients provided evidence of significant decline of the erythropoietic activity of the bone marrow. Erythroid cells in the marrow were depleted and also showed reduced proliferative activity as indicated by lower 3H-thymidine labeling index. Plasma erythropoietin levels were reduced, often being immeasurable by the polycythemic mouse bioassay technique. These changes in erythropoiesis in the hypothyroid state appear to be a part of physiological adjustment to the reduced oxygen requirement of the tissues due to diminished basal metabolic rate. Similar investigations revealed mild erythrocytosis in a significant proportion of patients with hyperthyroidism. Failure of erythrocytosis to occur in other patients of this group was associated with impaired erythropoiesis due to a deficiency of hemopoietic nutrients such as iron, vitamin B12 and folate. The mean plasma erythropoietin level of these patients was significantly elevated; in 4 patients the levels were in the upper normal range whereas in the rest, the values were above the normal range. The bone marrow showed erythyroid hyperplasia in all patients with hyperthyroidism. The mean 3H-thymidine labeling index of the erythroblasts was also significantly higher than normal in hyperthyroidism; in 8 patients the index was within the normal range whereas in the remaining 13 it was above the normal range. Erythrokinetic studies also provided evidences of increased erythropoietic activity in the bone marrow. It is postulated that thyroid hormones stimulate erythropoiesis, sometimes leading to erythrocytosis provided there is no deficiency of hemopoietic nutrients. Stimulation of erythropoiesis by thryoid hormones appears to be mediated through erythropoietin.

Biological Assay↗