Immediate results and long-term follow-up after repeat balloon aortic valvuloplasty.

Balloon aortic valvuloplasty (BAV) was performed in 219 elderly patients with aortic stenosis between December 1985 and April 1990. Forty-three patients underwent repeat BAV for symptomatic restenosis of the aortic valve 13 +/- 8 mo following initial BAV. To evaluate the outcome following initial and repeat BAV, hemodynamic results were analyzed according to the following subgroups: BAV 1--initial BAV for all patients (n = 219); BAV 1/1--initial BAV in those who had only one BAV (n = 176); BAV 1/2--the initial BAV in those who had repeat BAV (n = 43); and BAV 2--repeat BAV (n = 43). The mean age of patients undergoing BAV 2 was 82 +/- 6 yr compared to 78 +/- 10 yr for all patients undergoing BAV 1 (p = .01). At the time of BAV 1 there was no difference in baseline or post-valvuloplasty aortic valve area (AVA) or peak aortic valve gradient (AVG) for patients having BAV 1/1 compared to those having BAV 1/2. However, for patients having repeat BAV, although the magnitude of the hemodynamic improvement of BAV 1/2 (AVA increased from 0.6 to 0.9 cm2, AVG decreased from 68 to 34 mm Hg, p less than .001) was similar to the magnitude of the hemodynamic improvement of BAV 2 (AVA increased from 0.5 to 0.8 cm2, AVG decreased from 65 to 34 mm Hg, p less than .001), the baseline AVA (0.5 cm2 at BAV 2 vs. 0.6 at BAV 1/2) and the post-valvuloplasty AVA (0.8 cm2 at BAV 2 vs. 0.9 at BAV 1/2) were significantly smaller (p less than .004).(ABSTRACT TRUNCATED AT 250 WORDS)

Actuarial Analysis↗

Predictors of event-free survival after balloon aortic valvuloplasty.

BACKGROUND: Balloon aortic valvuloplasty was developed as an alternative to aortic-valve replacement in selected elderly patients with aortic stenosis. The use of this procedure is limited, however, by a high incidence of restenosis. METHODS: Between December 1985 and April 1989, valvuloplasty was performed in 205 patients. We evaluated 40 demographic and hemodynamic variables as univariate predictors of event-free survival by Cox regression analysis and identified independent predictors of event-free survival by stepwise multivariate analysis. RESULTS: Early hemodynamic results indicated a decrease in the peak transaortic-valve pressure gradient from 67 +/- 28 to 33 +/- 15 mm Hg after valvuloplasty and an increase in aortic-valve area from 0.6 +/- 0.2 to 0.9 +/- 0.3 cm2 (P less than 0.001 for both comparisons). The rate of event-free survival (defined as survival without recurrent symptoms, repeated valvuloplasty, or aortic-valve replacement) was 18 percent over the mean (+/- SD) follow-up period of 24 +/- 12 months (range, 1 to 47). Significant predictors of event-free survival included the left ventricular ejection fraction and the left ventricular and aortic systolic pressure before valvuloplasty, and the percent reduction in the aortic-valve pressure gradient; the pulmonary-capillary wedge pressure was inversely associated with event-free survival. Although the predicted event-free survival rate for the entire patient group was 50 percent at one year (95 percent confidence interval, 43 to 57 percent) and 25 percent at two years (95 percent confidence interval, 19 to 31 percent), the probability of event-free survival at one year varied between 23 and 65 percent when patients were stratified according to three independent predictors: the aortic systolic pressure, the pulmonary-capillary wedge pressure, and the percent reduction in the peak aortic-valve gradient. CONCLUSIONS: The most important predictors of event-free survival after balloon aortic valvuloplasty were related to base-line left ventricular performance. The best long-term results after valvuloplasty were observed among patients who would also have been expected to have excellent long-term results after aortic-valve replacement.

Aortic Valve Stenosis↗

Hemodynamic evaluation of a chronically implanted, electrically powered left ventricular assist system: responses to acute circulatory stress.

Hemodynamic stress testing was performed in four calves with a chronically implanted left ventricular assist device consisting of a double-valved pump interposed between the left ventricular apex and the descending thoracic aorta. The device was powered either pneumatically (n = 1) or with a transcutaneous energy transmission system (n = 3). Hemodynamic evaluation (cardiac output and right and left ventricular and pulmonary and carotid artery pressures) was carried out at baseline and during all hemodynamically stressed states. Atrial pacing and ventricular pacing to a heart rate of 140 beats/min resulted in no significant change in right or left heart filling pressures or cardiac output. Preload reduction with nitroprusside or transient inferior vena cava balloon occlusion resulted in a marked decrease in left ventricular pressure with preservation of mean arterial pressure. Phenylephrine administration resulted in a marked rise in mean arterial pressure with no change in cardiac output or filling pressure. Induction of ventricular fibrillation resulted in a decrease of mean left ventricular pressure to 11 +/- 8 mm Hg, but mean arterial pressure was maintained at greater than or equal to 50 mm Hg. It is concluded that a multicomponent, implantable, electrically powered assist system is capable of maintaining a normal cardiac output under a wide range of loading conditions and chronotropic states. Although this device is clearly preload dependent, it is capable of maintaining normal systemic pressures during conditions of severe left ventricular dysfunction and circulatory collapse.

Animals↗

The Mansfield Scientific Aortic Valvuloplasty Registry: overview of acute hemodynamic results and procedural complications.

Between December 1, 1986 and October 30, 1987, balloon aortic valvuloplasty was performed in 492 patients with aortic stenosis (mean age 79 +/- 8.4 years) enrolled in the Mansfield Scientific Aortic Valvuloplasty Registry. All procedures were performed from a femoral approach (92%), brachial approach (6%) or transseptal approach (2%) and utilized either a single balloon technique (72%) or a double balloon technique (28%). Valvuloplasty resulted in a significant improvement in aortic valve area (0.50 +/- 0.18 cm2 to 0.82 +/- 0.30 cm2), mean aortic valve gradient (60 +/- 23 mm Hg to 30 +/- 13 mm Hg) and cardiac output (3.86 +/- 1.26 to 4.05 +/- 1.31 liters/min). Serial aortography demonstrated a moderate or severe increase in aortic insufficiency in only 2.1% of patients. Statistical analysis of the procedural factors affecting acute valvuloplasty results demonstrated significant correlations of single versus double balloon technique, total number of balloon inflations and total number of balloon exchanges with respect to the absolute change in mean aortic valve gradient occurring during the valvuloplasty procedure. In addition, there was a significant correlation between the maximal time of valvuloplasty balloon inflation with aortic valve area measured after valvuloplasty, and there were significant correlations of the total number of balloon inflations and total number of balloon exchanges with the aortic valve mean gradient measured after valvuloplasty. The overall complication rate for the procedure was 20.5%, including vascular injury in 11%, embolic phenomenon in 2.2%, ventricular perforation resulting in tamponade in 1.8%, massive aortic insufficiency in 1%, nonfatal arrhythmia in 0.8% and myocardial infarction in 0.2%.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Real-time, intracardiac, two-dimensional echocardiography: enhanced depth of field with a low-frequency (12.5 mhz) ultrasound catheter.

Advances in catheter-based ultrasound imaging technology allow for a unique opportunity to develop two-dimensional intracardiac echocardiography, an imaging method that could have significant clinical applications. In this study, we evaluated the potential of a new, percutaneous, 9-Fr prototype intracardiac echocardiographic catheter with a 12.5-MHz rotating crystal in 13 dogs. In all dogs, we were able to easily advance the intracardiac echocardiographic catheter into the right and left hearts percutaneously and obtain dynamic images of cardiac structures in various imaging planes. With the intracardiac echocardiographic catheter in the right atrium, the whole chamber could be visualized. Minor manipulation allowed visualization of the right atrium, right ventricle, and tricuspid valve in a two-chamber view; further maneuvering yielded four-chamber views. With advancement of the catheter into the right ventricle and pulmonary artery, the right ventricular cavity, right ventricular outflow tract, and pulmonary artery could be imaged. The intracardiac echocardiographic catheter in the aortic root allowed visualization of the pulmonary artery and its bifurcation, superior portions of the atria, interatrial septum, aortic valve, and the proximal left coronary artery. With the intracardiac echocardiographic catheter in the left ventricle, short-axis images of the whole left ventricle were obtained. Manipulating the catheter tip within the left ventricle, we could visualize the left ventricle, left atrium (LA), and the mitral valve in the long axis. We were also able to visualize and identify experimentally-induced ischemic regional left ventricular dyskinesis (four of of five dogs), aortic valvular tear (five out of five dogs), and pericardial effusion with right atrial collapse (two out of two dogs). Intracardiac echocardiography was not associated with any complications. We conclude that percutaneous, low-frequency intracardiac echocardiography with a 12.5-MHz, 9-Fr catheter yields cardiac images in many imaging planes with a good depth of field, allows identification of valvular, myocardial, and pericardial abnormalities, and has excellent clinical potential in the assessment of many cardiovascular disorders.

Animals↗

Assessment of right atrial pressure-volume relations in patients with and without an atrial septal defect.

Assessment of the complex relations between pressure and volume in the right atrium has been hampered in the past by difficulties in the measurement of atrial volume. Accordingly, in the present study the dynamics of right atrial pressure-volume relations were examined (with the use of an impedance catheter to measure right atrial volume) in patients with and without an atrial septal defect. Right atrial pressure and impedance volume were measured in 16 patients at the time of cardiac catheterization with the use of a multi-electrode impedance catheter to provide continuous, on-line, pressure-volume data. Eleven patients without evidence of an interatrial shunt were examined during normal respiration and during the Valsalva maneuver and contrasted with five patients with an atrial septal defect documented by oxygen saturation step-up and echocardiographic studies. Right atrial pressure-volume diagrams in patients without an atrial septal defect exhibited the normal figure eight pattern, with an A loop (atrial contraction) and a V loop (passive filling), corresponding to the A wave and V wave of right atrial pressure, respectively. During inspiration, mean right atrial pressure decreased and mean right atrial volume increased, consistent with augmented venous return. With the Valsalva maneuver, right atrial pressure increased and both right atrial stroke volume and mean right atrial volume decreased compared with baseline. Patients with an atrial septal defect demonstrated baseline pressure-volume diagrams similar to those of patients without an interatrial shunt. However, no change in mean right atrial volume occurred with either respiration or the Valsalva maneuver despite changes in right atrial pressure similar to those seen inpatients without an atrial septal defect.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Effects of respiration and vasodilation on venous volume in animals and man, as measured with an impedance catheter.

Venous return determines cardiac preload and is in turn affected by respiration and vasodilation. The purpose of the present study was to examine the dynamics of venous return and venous volume, using impedance volume measurements in the venous system. In order to develop a methodology for the assessment of venous volume and venous return in man, we first studied 17 endotracheally intubated and ventilated anesthetized closed-chest dogs. We measured central venous and inferior vena cava (IVC) pressure (micromanometer) and volume (impedance catheter). Studies were done above and below the diaphragm with normal ventilation, with positive end-expiratory pressure (PEEP), and with beta-adrenergic blockade and i.v. nitroglycerin. Intrathoracic IVC volume fell and extrathoracic IVC volume rose with lung inflation, while PEEP raised extrathoracic IVC volume and lowered intrathoracic IVC volume. Nitroglycerin lowered intrathoracic IVC volume. Beta blockade did not affect IVC volume, ventilatory variation, or response to PEEP and nitroglycerin. We performed similar studies in 14 human subjects during normal quiet respiration, with measurements above and below the diaphragm, and with interventions including Valsalva maneuver and i.v. nitroglycerin. Intrathoracic IVC volume fell and extrathoracic IVC volume rose with expiration and Valsalva maneuver. Nitroglycerin again lowered intrathoracic IVC volume. We conclude that venous volume and the dynamics of venous return can be assessed in animals and man with an impedance catheter. Specifically, we show the divergent effects of respiration, ventilation, PEEP, and nitroglycerin on IVC volumes above and below the diaphragm. Beta-adrenergic blockage does not appear to play a role in altering any of these effects.(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenergic beta-Antagonists↗

Serial assessment of mitral regurgitation by pulsed Doppler echocardiography in patients undergoing balloon aortic valvuloplasty.

Mitral regurgitation was serially assessed by pulsed Doppler echocardiography in 144 patients undergoing balloon aortic valvuloplasty for symptomatic aortic stenosis. Regurgitant scores of 0, 1, 2 and 3 were assigned to pulsed Doppler patterns corresponding to no, mild, moderate and severe mitral regurgitation, respectively. Before balloon aortic valvuloplasty, mitral regurgitant score correlated significantly (p less than 0.005) but weakly with aortic valve area (r = -0.24), left ventricular ejection fraction (r = -0.34) and left ventricular systolic pressure (r = 0.23). There was no significant correlation between mitral regurgitation and either mean catheterization or mean Doppler aortic valve gradient. Balloon aortic valvuloplasty produced significant decreases in both catheterization and Doppler mean transvalvular aortic valve gradients (56 +/- 19 to 31 +/- 12 and 60 +/- 19 to 48 +/- 16 mm Hg, respectively; both p less than 0.0001) and a significant increase (p less than 0.0001) in aortic valve area assessed by catheterization (0.6 +/- 0.2 to 0.9 +/- 0.3 cm2). Left ventricular ejection fraction did not change, but cardiac output increased (p less than 0.001) and pulmonary capillary wedge pressure decreased (p less than 0.0001). Pulsed Doppler findings of mitral regurgitation were present in 102 of the 144 patients. Eighty-eight patients had a score compatible with mild or more severe degrees of mitral regurgitation, and 49 had a score indicative of moderate or severe valvular insufficiency. In the entire group of 144 patients, mitral regurgitant score decreased significantly from 1.1 +/- 1.0 to 1.0 +/- 1.0 (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Progressive improvement in pulmonary vascular resistance after percutaneous mitral valvuloplasty.

Percutaneous mitral valvuloplasty has been proposed as a nonsurgical technique for treating high-risk patients with mitral stenosis who are deferred from mitral valve replacement. The effect of this technique on patients with pulmonary hypertension, however, has not been fully evaluated. Accordingly, serial assessment of pulmonary vascular resistance was made in 14 patients with critical mitral stenosis and pulmonary hypertension (pulmonary vascular resistance greater than 250 dynes.sec/cm5 or mean pulmonary artery pressure greater than 40 mm Hg or both) who underwent percutaneous balloon dilatation of the mitral valve. Balloon valvuloplasty was performed with either one (n = 10) or two (n = 4) balloons through the transseptal approach, and it resulted in significant improvement in mean mitral gradient (from 18 +/- 4 to 9 +/- 4 mm Hg, p less than 0.001), systemic blood flow (from 3.7 +/- 1.2 to 5.0 +/- 2.2 l/min, p less than 0.001), and calculated mitral valve area (from 0.7 +/- 0.2 to 1.6 +/- 0.7 cm2, p less than 0.001). Immediately after balloon mitral valvuloplasty, pulmonary vascular resistance fell from 630 +/- 570 to 447 +/- 324 dynes.sec/cm5. Repeat catheterization 7 +/- 4 months after valvuloplasty showed further improvement of pulmonary hypertension in 12 of the 14 patients, with a mean pulmonary vascular resistance for the group as a whole of 280 +/- 183 dynes.sec/cm5, p less than 0.005. In two patients, mitral valve restenosis to a mitral valve area less than 1.0 cm2 was associated with a return of pulmonary hypertension to predilatation values.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

The use of nitroprusside to characterize aortic pressure-diameter relationships.

The viscoelastic properties of the wall of the ascending aorta can be determined by calculating the relationship between pressure and diameter of the vessel. Because of potential nonlinearities in aortic pressure-diameter relationships, however, pressure-diameter curves are more accurate than compliance expressed as a single value in measuring aortic viscoelastic properties. To determine whether nitroprusside could be used to obtain aortic pressure-diameter curves over a wide range, we measured simultaneous aortic pressure and diameter in anesthetized dogs. The inferior vena cava (IVC) of each animal was briefly occluded to generate a baseline series of pressure-diameter points over a wide range of pressure and diameter. We found that moderate lowering of systolic arterial pressure (30 mmHg) with nitroprusside did not significantly affect the aortic pressure-diameter relationship in comparison with control measurements during brief IVC occlusions at similar pressures and diameters. Prolonged inferior vena caval occlusion and a more profound lowering of arterial pressure with nitroprusside or IVC occlusion resulted in a leftward and upward shift of the aortic pressure-diameter relationship, with higher pressures at comparable diameters and lower diameters at comparable pressures. However, with more profound changes in arterial pressure, possible reflex-mediated mechanisms that alter the baseline aortic pressure-diameter relationship may be activated. We conclude that nitroprusside can be used to obtain aortic pressure-diameter data over a wider range than that possible from a single cardiac cycle.

Journal Article↗

Use of balloon flotation pacing catheters for prophylactic temporary pacing during diagnostic and therapeutic catheterization procedures.

The use of prophylactic temporary pacemakers during diagnostic catheterization, coronary angioplasty and percutaneous balloon valvuloplasty was investigated retrospectively over an 18-month period. Balloon flotation temporary pacemaker leads were placed in 193 (12%) of 1,609 patients undergoing diagnostic catheterization, 641 (65%) of 993 patients undergoing coronary angioplasty and 199 (100%) of 199 patients undergoing aortic or mitral valvuloplasty. There were no perforations or significant arrhythmic complications related to pacemaker placement in these 1,033 cases, and pacing was initiated promptly when required by withdrawal of the catheter tip into the right ventricle. Significant bradycardia or new conduction defects developed in 17 patients (1%) during diagnostic catheterization, 10 patients (1%) during angioplasty and 20 patients (10%) during valvuloplasty, but were severe enough to require initiation of temporary pacing in only 1 (0.06%), 4 (0.4%) and 5 (2.5%) patients, respectively. No patient undergoing diagnostic catheterization or angioplasty (but 5 patients undergoing valvuloplasty) required immediate pacing support to treat a life-threatening bradycardia. The total cost of prophylactic pacemakers was $103,300, with a cost per actual use of $19,300 for diagnostic cases, $16,025 for angioplasty and $3,980 for balloon valvuloplasty. These data suggest that prophylactic temporary pacing is not indicated during either diagnostic catheterization or coronary angioplasty, but should be used routinely during balloon valvuloplasty.

Angioplasty, Balloon↗

Usefulness of noninvasive assessment of aortic stenosis before and after percutaneous aortic valvuloplasty.

Noninvasive and catheterization studies were performed in 40 patients (mean age 76 +/- 12 years) before and after percutaneous aortic valvuloplasty. Measurements included time to 1/2 carotid upstroke, left ventricular ejection time, aortic valve excursion, mean aortic valve gradient and aortic valve area assessed using the continuity equation: aortic valve area = A X V/V1, where A = left ventricular outflow tract area, V = maximal left ventricular outflow tract velocity assessed by pulsed Doppler echocardiography and V1 = peak velocity in the aortic stenotic jet assessed using continuous-wave echocardiography. In addition, mitral regurgitation was assessed by pulsed Doppler mapping techniques. Mean aortic valve gradient, cardiac output and aortic valve area, calculated using the Gorlin formula, were determined at cardiac catheterization. There were significant correlations between Doppler and catheterization measurements of aortic valve area both before (r = 0.71, p less than 0.001) and after (r = 0.85, p less than 0.0001) valvuloplasty. The relations were demonstrated to be linear by F test and met criteria for identity. There were significant increases (all p less than 0.0005) after valvuloplasty in catheterization valve area (0.60 +/- 0.21 to 0.95 +/- 0.39 cm2), Doppler valve area (0.64 +/- 0.22 to 0.91 +/- 0.37 cm2), valve excursion (0.5 +/- 0.3 to 0.8 +/- 0.3 cm) and cardiac output (4.5 +/- 1.6 to 4.9 +/- 1.7 liter/min).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Initial success and long-term follow-up of percutaneous transluminal coronary angioplasty in chronic total occlusions versus conventional stenoses.

Coronary angioplasty was attempted in 1,074 consecutive patients, including 169 patients with total (100%) occlusion (group 1), 102 patients with functional total (99%) occlusion (group 2) and 711 patients with conventional (70 to 95%) stenoses (group 3). After exclusion of 92 patients with acute myocardial infarction, the mean age of the patients was 57 +/- 12 years, including 727 men (74%) and 255 women (26%). Although there were no differences between groups with respect to anginal symptoms or extent of coronary artery disease, the primary success rate (by lesion) varied according to lesion severity, and was 63%, 78% and 90% for groups 1, 2 and 3, respectively (p less than 0.001). Only 3 patients (1%) with chronic coronary artery occlusion (groups 1 and 2) required emergency surgery because of side-branch occlusion in 2 patients and guidewire fracture in 1 patient, whereas emergency surgery was required in 14 patients (2%) in group 3. Long-term follow-up averaging 19 +/- 11 months was available for 95% of patients. Although the combined likelihood of death or nonfatal myocardial infarction was below 6% for each group at 2 years (difference not significant), the likelihood of death, nonfatal infarction, coronary bypass surgery or repeat percutaneous transluminal coronary angioplasty was higher (41%) in group 1 than in groups 2 (28%) or 3 (28%) (p less than 0.001). Thus, coronary angioplasty can be performed safely and effectively in patients with chronic total occlusion, although neither the primary success rate nor the long-term follow-up are as favorable as in patients with conventional stenoses.

Angioplasty, Balloon↗

Use of percutaneous transluminal coronary angioplasty and bypass surgery despite improved medical therapy for unstable angina pectoris.

To evaluate current strategies for the management of unstable angina, 104 consecutive patients admitted to the coronary care unit with unstable angina during a 6-month period were followed prospectively. Although 58 patients had symptomatic relief with the initiation of intensive medical therapy, 46 (44%) continued to have episodes of angina despite maximal tolerated triple-drug antianginal therapy as well as aspirin or heparin, or both. In-hospital mortality for the 104 patients was 4%. The incidence of myocardial infarction was 8%, and differed (p less than 0.01) for the medically responsive group (3%) vs the medically refractory group (13%). Based on clinical status and coronary anatomy, patients were referred for either bypass surgery (46%), coronary angioplasty (41%) or continued medical therapy (13%). Choice of therapy varied according to the extent of coronary disease, with coronary angioplasty attempted in 72% of patients with 1-vessel disease, 44% of patients with 2-vessel disease and 7% of patients with 3-vessel disease. Angioplasty was performed with an initial success rate of 88%, and compared favorably with bypass surgery in terms of in-hospital mortality (0 vs 11%), late mortality (2.8 vs 7.7%), freedom from angina (62 vs 69%) and subsequent employment (44 vs 27%) at 18 months follow-up. The favorable results of angioplasty in this prospective observational study suggest that additional randomized trials should be conducted in this important patient group.

Adrenergic beta-Antagonists↗

Balloon valvuloplasty for treating pulmonic, mitral and aortic valve stenosis.

Percutaneous balloon valvuloplasty is a technique that has been developed in the cardiac catheterization laboratory over the last 5 years for the treatment of pulmonic, mitral and aortic valve stenosis in children and adults. This review will attempt to summarize recent advances in this new field of invasive cardiology over the last several years.

Aortic Valve Stenosis↗

Noninvasive assessment of mitral stenosis before and after percutaneous balloon mitral valvuloplasty.

Thirty-seven patients with symptomatic mitral stenosis underwent balloon dilatation of the mitral valve. Significant increases (p less than 0.001) were noted in both catheterization- and Doppler-determined valve area (0.9 +/- 0.3 to 1.8 +/- 0.8 and 0.9 +/- 0.2 to 1.7 +/- 0.5 cm2). However, catheterization and Doppler areas before and after valvuloplasty correlated less well (r = 0.51, p less than 0.002 and r = 0.47, p less than 0.005, respectively) than the catheterization-Doppler area correlation in a previous study of 59 consecutive patients with varying degrees of mitral stenosis (r = 0.84, p less than 0.001). Mitral valve area increases were independent of valve thickness estimated using 2-dimensional echocardiography. Flail mitral leaflet movement was not observed and the degree of mitral regurgitation qualitatively assessed using pulsed Doppler mapping techniques increased by greater than 1 of 4 grades in only 1 patient. The lateral mitral valve orifice diameter increased more than the anteroposterior diameter, suggesting commissural splitting as the mechanism of successful valvuloplasty. Increases (all p less than 0.0001) were noted in mitral valve EF slope (7 +/- 5 to 18 +/- 10 mm/s), excursion (11 +/- 5 to 13 +/- 4 mm), S20S interval (0.07 +/- 0.02 to 0.08 +/- 0.02 s) and cardiac output (4.2 +/- 1.3 to 5.3 +/- 2.0 liters/min). There were significant decreases (all p less than 0.001) in left atrial diameter (5.4 +/- 1.0 to 5.1 +/- 1.0 cm), mean catheterization gradient (15 +/- 5 to 8 +/- 4 mm Hg) and mean Doppler gradient (10 +/- 4 to 6 +/- 3 mm Hg).(ABSTRACT TRUNCATED AT 250 WORDS)

Catheterization↗