Search PubMed⌕ Search

Biomedical subjects

R G McKay

Publications and source records attributed to R G McKay.

At least 37 records · Page 2Linked to original sources

Factors associated with the release of cardiac troponin T following percutaneous transluminal coronary angioplasty.

BACKGROUND: Recent studies have suggested that immunoassay of cardiac troponin T (cTnT) provides a more sensitive measurement of myocardial necrosis than creatine kinase MB (CK-MB) mass concentration. HYPOTHESIS: The purpose of this study was to compare the release of cTnT and CK-MB isoenzyme in patients undergoing percutaneous coronary angioplasty, and to investigate the clinical, procedural, and angiographic correlates of abnormal elevations of both of these markers. METHODS: Total creatine kinase (total CK), CK-MB, and cTnT levels were measured immediately before and 12 h following intervention in 110 patients, including 100 consecutive patients undergoing coronary angioplasty and 10 control patients undergoing diagnostic cardiac catheterization. All patients had normal levels of all three markers at baseline. A postintervention total CK level > 225 U/l, an increase in CK-MB > 5.0 ng/ml, and/or an increase in cTnT > 0.04 ng/ml were considered indicative of myocardial injury. RESULTS: Coronary angioplasty was successfully performed in all 100 patients without emergency bypass surgery or death, although six patients required emergent placement of an intracoronary stent for threatened closure. Eight patients demonstrated an abnormal increase in total CK, including six who were undergoing primary angioplasty for an acute myocardial infarction. One of these patients sustained a Q-wave infarction. Post angioplasty, 18 patients had elevations of both CK-MB and cTnT, 23 had elevations of only cTnT, and the remaining 59 patients had elevations of neither. All patients with CK-MB elevation also had cTnT elevation. Neither serologic marker increased in the diagnostic catheterization control patients. In comparison with patients without postintervention cTnT rise, patients with abnormal cTnT levels had a higher incidence of complex lesion morphology (p < 0.01) and intracoronary thrombus (p < or = 0.0001) prior to coronary angioplasty, and a higher incidence of coronary dissection (p < or = 0.01), abrupt closure (p < or = 0.05), and side-branch occlusion (p < or = 0.01) during angioplasty. In patients with elevation of both cTnT and CK-MB, postintervention CK-MB levels were 12-fold higher and cTnT levels were 21-fold higher than in patients with isolated elevation of only cTnT (p < 0.01). CONCLUSIONS: These data indicate that > 40% of patients undergoing coronary angioplasty have evidence of minor degrees of myocardial damage, as evidenced by cTnT release. High-risk coronary lesions and both minor and major complications of angioplasty are associated with cTnT release. cTnT appears to be a more sensitive marker of myocardial injury than CK-MB under these circumstances. In comparison with isolated cTnT rise, elevation of both CK-MB and cTnT may be indicative of greater levels of myocardial injury.

Aged↗

Use of local drug delivery for treating intracoronary thrombus and thrombus-containing stenoses.

The local delivery of thrombolytic agents directly to the site of intracoronary thrombus using catheter-based technology is a new technique for treating intraluminal clot and thrombus-containing stenoses that is currently under active investigation. The theoretic mechanism of thrombolysis underlying this approach involves the 'trapping' of thrombus in an environment of high thrombolytic drug concentration, mechanical disruption of intraluminal clot by the drug delivery catheter itself, and intramural deposition of lytic agents with the creation of a drug reservoir that may provide for prolonged local thrombolysis. To date, animal studies with five local drug delivery catheters have documented successful intramural deposition of thrombolytic agents at balloon angioplasty sites. Three of these devices have also been successfully used in patients to treat intracoronary thrombus, with preliminary results suggesting that thrombolysis can be achieved using much lower doses of lytic agents than are employed in standard infusion protocols and with low complication rates. These preliminary observations will be studied further in two multicentre randomized protocols comparing local thrombolysis with standard techniques for treating intracoronary thrombus.

Animals↗

Enhanced intracoronary thrombolysis with urokinase using a novel, local drug delivery system. In vitro, in vivo, and clinical studies.

BACKGROUND: Current pharmacological regimens for treating intracoronary thrombus in the cardiac catheterization laboratory generally involve the administration of thrombolytic agents that result in a systemic fibrinolytic state and/or require prolonged arterial drug infusion. The purpose of the present study was to assess a new technique for treating intracoronary thrombus consisting of the local infusion of limited quantities of urokinase with a novel drug delivery device. METHODS AND RESULTS: THe Dispatch coronary infusion catheter is a new local drug delivery system that allows for the prolonged infusion of therapeutic agents at an angioplasty site while distal coronary flow is maintained. Three experimental protocols were performed to determine the in vitro, in vivo, and clinical efficacy of this device. First, in vitro thrombolysis of fresh, porcine thrombus trapped in a 4-mm plastic tube with a 50% constriction and perfused with 20% porcine plasma was measured. Twenty-three thrombi were weighed before and after no treatment (n = 5), "systemic" urokinase administration (n = 4), local infusion of 150,000 U urokinase with a standard end-hole catheter (n = 4), local infusion of saline with the Dispatch catheter (n = 5), and local infusion of 150,000 U urokinase with the Dispatch catheter (n = 5). Second, 25 porcine coronary arteries in 23 pigs were dilated in vivo with conventional balloon angioplasty and then treated with 123I-labeled urokinase that was administered either by the Dispatch catheter (150,000 U; n = 16), intravenous systemic bolus (1,000,000 U; n = 3), guiding catheter infusion (500,000 U; n = 3), or local end-hole catheter infusion (150,000 U; n = 3). All vessels were subsequently harvested to quantify intramural deposition and subsequent washout of urokinase at the angioplasty site. Finally, 19 patients with angiographic evidence of intracoronary thrombus were treated with local urokinase infusion with the Dispatch catheter either before or after balloon angioplasty or directional atherectomy. In vitro studies demonstrated that infusion of urokinase with the Dispatch catheter decreased thrombus weight by 66% compared with no treatment (-25%), "systemic" urokinase administration (25%), end-hole catheter urokinase infusion (32%), or infusion of saline by the Dispatch catheter (32%) (P < or = .005). In vivo studies demonstrated immediate deposition of 0.12% of the urokinase delivered by the Dispatch catheter to the angioplasty site, compared with 0.0007% with systemic bolus, 0.003% with guiding catheter infusion, and 0.007% with local infusion with an end-hole catheter (P < .001). Urokinase deposited by the Dispatch catheter persisted intramurally for at least 5 hours. Patient studies demonstrated reduction of thrombus-containing stenoses and complete disappearance of intracoronary thrombus in all cases in which 150,000 U urokinase was locally infused over 30 minutes. There was no evidence of abrupt closure, distal embolization, or no reflow in any patient. CONCLUSIONS: Local urokinase delivery with the Dispatch catheter can result in rapid and complete intracoronary thrombolysis using substantially less drug than standard thrombolytic techniques. Intramural deposition of drug with this technique creates a local reservoir of urokinase that may provide prolonged thrombolytic activity at the infusion site.

Adult↗

Treatment of acute stent thrombosis with local urokinase therapy using catheter-based, drug delivery systems: a case report.

Abrupt thrombotic stent closure remains a difficult problem to treat in the cardiac catheterization laboratory. A 63-yr-old white female initially underwent successful placement of a Palmaz-Schatz biliary stent in the proximal RCA following failed coronary angioplasty. One week later, the patient represented with an acute inferior infarction and thrombotic occlusion of the stent site in spite of adequate anticoagulation. A new, local drug infusion catheter (the Dispatch catheter) was placed at the angioplasty site and 150,000 units of urokinase were locally infused, with immediate restoration of normal distal flow and a subsequent marked decrease in angiographic thrombus. A small, residual thrombotic filling defect was further treated with a urokinase-coated hydrogel balloon (Hydro Plus). Following local urokinase delivery with the Dispatch catheter and hydrogel balloon, there was complete resolution of angiographic thrombus with TIMI 3 flow and no evidence of distal embolization or no-reflow. Local urokinase delivery directly to the site of thrombus with catheter-based drug delivery systems may be a useful technique for rapidly lysing intracoronary clot and re-establishing coronary flow in the setting of acute stent thrombosis.

Angioplasty, Balloon, Coronary↗

Primary angioplasty using a urokinase-coated hydrogel balloon in acute myocardial infarction during pregnancy.

A 38-year-old multigravid white female presented at 16 weeks gestation with an acute inferoposterolateral myocardial infarction. Emergent coronary angiography demonstrated a total proximal occlusion of a large dominant left circumflex artery with a filling defect at the site of the occlusion suggestive of thrombus. Primary angioplasty using a urokinase-coated hydrogel balloon resulted in successful recanalization of the vessel with restoration of normal TIMI Grade III flow and, most notably, apparent complete lysis of the intracoronary thrombus. After a subsequently uneventful pregnancy, a healthy baby was delivered.

Adult↗

Recanalization of totally occluded saphenous vein grafts using local urokinase delivery with the Dispatch catheter.

Current techniques for the percutaneous revascularization of totally occluded vein grafts are limited by a low initial success rate, a significant incidence of distal embolization, and a high rate of early graft reclosure. This case report describes two patients in whom graft recanalization was attempted with the combined use of balloon angioplasty/intra-graft stent placement and local urokinase delivery using a new angiotherapy catheter. Successful recanalization was achieved in both patients without major complications, in spite of a large thrombus burden as demonstrated by angiography.

Angioplasty, Balloon, Coronary↗

Feasibility of radiofrequency powered, thermal balloon ablation of atrioventricular bypass tracts via the coronary sinus: in vivo canine studies.

Radiofrequency catheter ablation of left-sided accessory pathways is technically demanding and usually requires left heart catheterization. The feasibility of creating lesions from within the coronary sinus of sufficient size to ablate accessory pathways in humans using a thermal balloon catheter was studied in 20 dogs. In group 1 (n = 14), 17 thermal inflations were performed in 12 dogs at either 70 degrees, 80 degrees, or 90 degrees C each for 30 or 60 seconds (in 2 dogs two non-thermal control inflations were performed). Animals were sacrificed 6.3 +/- 1.6 days later. In group 2 (n = 6), seven thermal inflations were performed at 90 degrees C each for 180, 300, or 360 seconds. Group 2 animals received antiplatelet and anticoagulant therapy for 1 week and were sacrificed at 13 +/- 10.7 days. In both groups, hemodynamic, angiographic, and electrocardiographic studies were performed at baseline, 1 hour after inflation, and prior to sacrifice. All dogs remained clinically stable throughout the procedure and no complications were attributed to the effect of thermal inflation. Thermal lesions measured 14.4 +/- 4.4 mm in length and extended from the coronary sinus intima to a mean depth of 2.9 +/- 1.2 mm (range 1.4-6.5 mm). Group 2 lesions were significantly deeper than group 1 lesions (P = 0.03). Of the 24 thermal lesions created, atrial necrosis was present in 23 and ventricular necrosis in 11. In all lesions there was some degree of either atrial necrosis, ventricular necrosis, or both. A variable degree of coronary sinus thrombus was present in 18 dogs without clinical sequelae. It is concluded that radiofrequency balloon heating via the coronary sinus can create thermal lesions in the atrioventricular sulcus of dogs that may be of sufficient size to ablate accessory left-sided pathways in humans.

Animals↗

Intracardiac ultrasound imaging during transseptal catheterization.

STUDY OBJECTIVE: The purpose of this study was to assess the feasibility of using small 12.5- or 20-MHz intracardiac ultrasound catheters to image the fossa ovalis and guide transseptal catheterization. DESIGN: The study was performed in three phases. First, in vitro imaging of human autopsy hearts was performed to define the intracardiac ultrasound appearance of the fossa ovalis and transseptal apparatus. Subsequently, the optimum approach for imaging the fossa ovalis in vivo was established in 30 patients. Finally, intracardiac ultrasound imaging was performed during transseptal catheterization of 10 patients undergoing percutaneous mitral commissurotomy. INTERVENTIONS: Intracardiac ultrasound imaging was performed with a 12.5- or 20-MHz single-element mechanical device in which a central imaging core is rotated within a 6F polyethylene sheath. MEASUREMENTS AND RESULTS: In both in vitro and in vivo studies, the fossa ovalis was easily identifiable as a thin membranous region surrounded by the thicker muscular portion of the interatrial septum. Initial in vivo studies established venous access by the femoral route to be superior to the internal jugular approach for catheter introduction. Studies performed during transseptal catheterization established the utility of using the fluoroscopic image of the catheter adjacent to the fossa ovalis to generate a guiding shot for positioning the transseptal apparatus. In addition, distention of the fossa prior to needle perforation could be demonstrated. However, since it was often difficult to track the tip of the needle, actual puncture of the fossa was rarely demonstrated. CONCLUSIONS: Intravascular ultrasound imaging can precisely locate the fossa ovalis in virtually all subjects. It therefore may assist transseptal catheterization.

Adult↗

Site-specific, catheter-based thrombolysis: a new technique for treating intracoronary thrombus and thrombus-containing stenosis.

Site-specific thrombolysis is a new technique for treating intracoronary thrombus and thrombus-containing stenoses that is currently under active investigation and that involves the local delivery of thrombolytic agents directly to intraluminal clot using catheter-based technology. The theoretic mechanisms of thrombolysis underlying this approach involves the "trapping" of thrombus in an environment of high thrombolytic drug concentration, mechanical disruption of intraluminal clot by the drug delivery catheter itself, and intramural deposition of lytic agents with the creation of a drug reservoir that may provide for prolonged local thrombolysis. To date, preliminary studies have documented enhanced local thrombolysis with urokinase using two new drug delivery systems--the Dispatch catheter and the hydrogel-coated balloon. In 68 patients that have been reported to date, use of these two new systems has resulted in enhanced intracoronary thrombolysis using much less urokinase than involved in standard infusion protocols, and with low complication rates. These preliminary observations will be further studied in two multicenter randomized protocols comparing local drug delivery with standard techniques for treating intracoronary thrombus.

Angioplasty, Balloon, Coronary↗

Treatment of intracoronary thrombus with local urokinase infusion using a new, site-specific drug delivery system: the Dispatch catheter.

BACKGROUND: The presence of intracoronary thrombus significantly increases the risk of conventional balloon angioplasty because of a high incidence of abrupt closure, distal embolization, and no-reflow phenomenon. The purpose of this study was to assess a new technique for treating intracoronary thrombus consisting of the local delivery of urokinase directly to the angioplasty site with a novel, catheter-based, drug delivery system. METHODS: The Dispatch catheter is a new local, drug-delivery device that allows for the prolonged infusion of therapeutic agents at an angioplasty site while still maintaining distal coronary perfusion. Six patients with angiographic or clinical evidence of intracoronary thrombus were treated with 150,000 units of urokinase over a 30-min period using this device prior to or following conventional balloon angioplasty and/or directional atherectomy. RESULTS: Successful delivery of urokinase directly to the angioplasty site was achieved in all 6 patients without hemodynamic or electrocardiographic compromise. In all six cases, local urokinase therapy resulted in complete dissolution of angiographic intracoronary thrombus and/or reduction of the coronary stenosis. Limited ischemia due to side-branch occlusion by the catheter's coils was noted in one patient. Distal embolization or no-reflow phenomenon were not observed in any case. CONCLUSION: The local drug-delivery catheter used in this study was able to successfully and rapidly achieve intracoronary thrombolysis by delivering limited quantities of urokinase directly to the angioplasty site, while still maintaining distal coronary perfusion. This technique of local, thrombolytic drug delivery may be useful in the percutaneous treatment of intracoronary thrombus and thrombus-containing stenoses.

Aged↗

Effect of low-grade conductive heating on vascular compliance during in vitro balloon angioplasty.

Radiofrequency-powered, thermal balloon angioplasty is a new technique that enhances luminal dilatation with less dissection than conventional angioplasty. The purpose of this study was to assess the effect of radiofrequency heating of balloon fluid on the pressure-volume mechanics of in vitro balloon angioplasty and to determine the histologic basis for thermal-induced compliance changes. In vitro, radiofrequency-powered, thermal balloon angioplasty was performed on 46 paired iliac segments freshly harvested from 23 nonatherosclerotic pigs. Balloon inflations at 60 degrees C were compared to room temperature inflations in paired arterial segments. Intraballoon pressure and volume were recorded during each inflation as volume infusion increased pressure over a 0 to 10 atm range. Pressure-volume compliance curves were plotted for all dilatations. Six segments were stained to assess the histologic abnormalities associated with thermal compliance changes. Radiofrequency heating acutely shifted the pressure-volume curves rightward in 20 of 23 iliac segments compared to nonheated controls. This increase in compliance persisted after heating and exceeded the maximum compliance shift caused by multiple nonheated inflations in a subset of arterial segments. Histologically, heated segments showed increased thinning and compression of the arterial wall, increased medial cell necrosis and altered elastic tissue fibers compared to nonheated specimens. In conclusion, radiofrequency heating of intraballoon fluid to 60 degrees C acutely increases vascular compliance during in vitro balloon angioplasty of nonatherosclerotic iliac arteries. The increased compliance persists after heating and can be greater than the compliance shifts induced by multiple conventional dilatations. Arterial wall thinning and irreversible alteration of elastic tissue fibers probably account for thermal compliance changes.

Angioplasty, Balloon↗

Intracardiac ultrasound determination of left ventricular volumes: in vitro and in vivo validation.

OBJECTIVES: This study was designed to assess the feasibility of calculating left ventricular volumes using intracardiac ultrasound. BACKGROUND: Previous studies have validated transthoracic echocardiographic determinations of left ventricular volumes and have indicated the superiority of Simpson rule reconstruction algorithms. The feasibility of imaging the left ventricle with intracardiac ultrasound has also been demonstrated. METHODS: The determination of left ventricular volumes with Simpson rule reconstruction of intracardiac ultrasound images was evaluated in two phases. In vitro validation was performed in 29 animal hearts preserved in either a nondistended or distended state. Latex cast volumes were the reference standard. In vivo studies used 14 pigs, and compared intracardiac ultrasound volumes and ejection fraction with single-plane contrast angiographic values. A 12.5-MHz device was used to record short-axis images at 0.5-cm intervals. These were used to reconstruct the ventricle as a stack of cylindric elements using all imaged levels as well as sections recorded every 1 and 2 cm and at a single midventricular level. RESULTS: In the in vitro hearts, when all recorded sections were used, there was excellent agreement between intracardiac ultrasound and latex cast volumes (intracardiac ultrasound volume = 0.89 latex cast volume + 2.22, r = 0.95; intracardiac ultrasound volume = 0.97 latex cast volume + 0.91, r = 0.99) for nondistended and distended hearts, respectively. In vivo, there was again close correspondence between ultrasound and angiographic volumes (intracardiac ultrasound volume = 1.04 angiographic volume - 3.6, r = 0.91). The relation between intracardiac ultrasound and angiographic ejection fraction was fair (intracardiac ultrasound ejection fraction = 1.00 angiographic ejection fraction + 6.85, r = 0.69). Excellent correlations for the volumes were maintained as the number of cross sections was reduced to those recorded every 1 and 2 cm (r = 0.87 to 0.99). With a single midventricular site more variable but generally good correlations were obtained (r = 0.77 to 0.99). CONCLUSIONS: The application of Simpson rule reconstruction to short-axis images of the left ventricle obtained with intracardiac ultrasound provides accurate determination of left ventricular volumes in animal hearts. This technique may prove useful in the analysis of left ventricular structure and function.

Algorithms↗

Localized intramural drug delivery during balloon angioplasty using hydrogel-coated balloons and pressure-augmented diffusion.

OBJECTIVES: This study was designed to assess the feasibility of using hydrogel-coated balloons to deliver biologically active agents to the blood vessel wall. BACKGROUND: The local intramural delivery of therapeutic agents during balloon angioplasty has been proposed as an adjunctive technique for preventing early intracoronary thrombosis and late restenosis. METHODS: To assess the efficacy of delivery and depth of penetration in vitro, local delivery of horseradish peroxidase was performed in 40 porcine peripheral arteries, and delivery of fluoresceinated heparin was performed in 20 porcine peripheral arteries and 7 human atheromatous arteries. To determine the persistence of these agents in the vessel wall in vivo, horseradish peroxidase was delivered to 18 porcine peripheral arteries that were harvested at intervals of 45 min to 48 h. Fluoresceinated heparin was delivered to 22 porcine peripheral arteries, 14 with the use of a protective sleeve, harvested at intervals of 30 s to 24 h. RESULTS: In vitro agent delivery was successful in all specimens. The depth of penetration of horseradish peroxidase was directly related to both balloon pressure (p < 0.04) and duration of inflation (p < 0.01). In vivo peroxidase staining was evident at 45 and 90 min but not thereafter. With the use of a protective sleeve, heparin was present in all arteries harvested at 30 s, with marked dissipation at 1 and 24 h. Without a sleeve, no fluorescein staining was detected in any artery. With both agents, delivery occurred consistently over broad regions of the vessel wall that were free of architectural disruption. CONCLUSIONS: Hydrogel-coated balloons can deliver biologically active agents to the vessel wall without gross tissue disruption and may provide an atraumatic method for the local delivery of therapeutic agents during balloon angioplasty.

Angioplasty, Balloon↗

Decreased platelet deposition and smooth muscle cell proliferation after intramural heparin delivery with hydrogel-coated balloons.

BACKGROUND: In vitro and in vivo studies have demonstrated both anticoagulant and antiproliferative effects of heparin. The purpose of this study was to assess the effect of local intramural delivery of heparin, using heparin-coated hydrogel balloons, on platelet deposition and early smooth muscle cell proliferation after in vivo balloon angioplasty. METHODS AND RESULTS: The effects of local heparin delivery were assessed during balloon angioplasty of porcine peripheral arteries. All balloon dilatations were performed with oversized hydrogel balloons coated with a known quantity of heparin. Balloon dilatations in contralateral vessels with uncoated hydrogel balloons served as study controls. The pharmacokinetics of heparin delivery were assessed using 3H-heparin to quantitate heparin wash-off from the balloon surface, heparin delivery to the arterial wall, and intramural persistence of drug. Platelet deposition at 1 hour after balloon injury was quantified using 111In-labeled platelets. Smooth muscle cell proliferation was assessed 6 to 7 days after angioplasty with immunohistochemical staining for proliferating cell nuclear antigen. 3H-heparin wash-off from the hydrogel balloon surface occurred rapidly, with approximately 95% of the heparin coating disappearing within 10 seconds in the intact circulation. Approximately 2% of heparin on the balloon surface was delivered intramurally at the time of angioplasty. Intramural heparin dissipated rapidly, although small amounts of intramural heparin could still be detected for at least 48 hours. In comparison to control vessels, there was less 111In-platelet deposition (P = .002) and less medial smooth muscle cell proliferation (P = .03) in heparin-treated vessels. CONCLUSIONS: Local intraluminal delivery of heparin at the time of balloon angioplasty with heparin-coated hydrogel balloons results in intramural deposition of drug that persists for at least 48 hours. This in vivo technique significantly decreases platelet deposition and early smooth muscle cell proliferation after angioplasty injury.

Angioplasty, Balloon↗

In vivo radiofrequency thermal balloon angioplasty of porcine coronary arteries: histologic effects and safety.

The purpose of this study was to assess the safety and histologic effects of radiofrequency thermal balloon angioplasty in the coronary vasculature of normal pigs. Radiofrequency thermal balloon angioplasty was performed in 30 coronary arteries of 16 nonatherosclerotic pigs. Heated inflations were performed at either 50 degrees, 60 degrees, or 70 degrees C for 30 or 60 seconds, and were compared with five nonheated inflations in five additional arteries. All balloon inflations were performed at 2 atm pressure with a balloon/vessel diameter ratio of 1.2 to 1. Heart rate, arterial pressure, and left ventricular pressure were monitored continuously for each animal. A 12-lead ECG, coronary angiography, and two-dimensional transthoracic echocardiography were performed before and 1 hour after each balloon inflation. Each animal was subsequently put to death for postmortem cardiac examination. Heated inflations were well tolerated in 28 of the 30 arteries without significant adverse effects. During one inflation, ventricular fibrillation occurred because of prolonged ischemia from an occlusive guiding catheter. In another artery, a heated inflation resulted in a dissection with a transient decrease in distal coronary flow. Histologic examination revealed a significant increase in wall thinning and elastic fiber straightening with heating at 70 degrees C for both 30 and 60 seconds, and a significant increase in intracoronary thrombus with heating at 70 degrees C for 60 seconds. Depth of periarterial myocardial heat necrosis paralleled the increase in temperature, with an average depth of 166 microns at 50 degrees C, 312 microns at 60 degrees C, and 1031 microns at 70 degrees C. In vivo, radiofrequency coronary angioplasty can be performed relatively safely without significant electrical, hemodynamic, or ischemic changes beyond those seen with conventional nonthermal angioplasty. The extent of heat-induced vessel wall thinning, elastic tissue straightening, intracoronary thrombus formation, and periarterial myocardial necrosis are all related to balloon temperature or duration of heating.

Angioplasty, Balloon, Coronary↗

Intracardiac echocardiography in humans using a small-sized (6F), low frequency (12.5 MHz) ultrasound catheter. Methods, imaging planes and clinical experience.

OBJECTIVES: This study was designed to determine the clinical utility and feasibility of using 12.5-MHz ultrasound catheters for intracardiac echocardiography. BACKGROUND: Intracardiac echocardiography is a potentially useful technique of cardiac imaging and monitoring in certain settings. The feasibility of intracardiac echocardiography using 20-MHz ultrasound catheters in patients has been demonstrated. High resolution images of normal cardiac structures as well as cardiac abnormalities have been obtained. However, imaging has been limited by the shallow depth of field inherent in high frequency ultrasound imaging. METHODS: Intracardiac echocardiography with 12.5-MHz catheters was performed in eight mongrel dogs and 92 patients. Catheters were introduced percutaneously in 80 patients studied in the catheterization laboratory and directly into the heart in 12 patients in the operating room. Right heart imaging was performed in 68 patients and arterial and left heart imaging in 35 patients. RESULTS: When these catheters were introduced into the venous system, the right atrium, tricuspid valve, right ventricle, pulmonary valve and pulmonary artery were visualized. Pericardial effusion, intracardiac masses and atrial septal defects were correctly identified. The left ventricle, left atrium, mitral valve, aortic valve, aorta and coronary arteries could be imaged from the arterial circulation. Diseases identified included valvular aortic stenosis, subvalvular aortic stenosis and Kawasaki disease. Average imaging time was 10 min. No complications occurred as a result of intracardiac echocardiography. CONCLUSIONS: Intracardiac echocardiography with 12.5-MHz ultrasound catheters is safe and feasible; it also provides anatomic and physiologic information. This feasibility study provides a foundation for wider clinical use of intracardic echocardiography.

Adolescent↗

Predictors of long-term outcome after percutaneous balloon mitral valvuloplasty.

BACKGROUND: Percutaneous balloon mitral valvuloplasty is known to produce short-term hemodynamic and symptomatic improvement in many patients with mitral stenosis. Comprehensive assessment of the clinical usefulness of balloon valvuloplasty requires evaluation of patients' long-term outcomes. METHODS: We performed balloon mitral valvuloplasty in 146 patients between October 1, 1985, and October 1, 1991. Base-line demographic, clinical, echocardiographic, and hemodynamic variables were evaluated in order to identify predictors of long-term event-free survival. RESULTS: Balloon mitral valvuloplasty was completed successfully in 136 (93 percent) of the patients in whom the procedure was attempted; it resulted in an increase in the mean (+/- SD) mitral-valve area from 1.0 +/- 0.4 to 2.1 +/- 0.9 cm2 and a decrease in the mean transmitral pressure gradient from 14 +/- 5 to 6 +/- 3 mm Hg (P < 0.001 for both comparisons). The estimated overall five-year survival rate was 76 +/- 5 percent, and the estimated five-year event-free survival rate (the percentage of patients without mitral-valve replacement, repeat valvuloplasty, or death from cardiac causes) was 51 +/- 6 percent. According to multivariate Cox proportional-hazards analysis, the independent predictors of longer event-free survival were a lower mitral-valve echocardiographic score (a measure of mitral-valve deformity; range, 0 for a normal valve to 16 for a seriously deformed valve; P < 0.001), lower left ventricular end-diastolic pressure (P = 0.001), and a lower New York Heart Association (NYHA) functional class (P = 0.04). Patients with no risk factors for early restenosis or only one risk factor (echocardiographic score > 8, left ventricular end-diastolic pressure > 10 mm Hg, or NYHA functional class IV) had a predicted five-year event-free survival rate of 60 to 84 percent, whereas patients with two or three risk factors had a predicted five-year event-free survival rate of only 13 to 41 percent. CONCLUSIONS: Balloon mitral valvuloplasty as a treatment for selected patients with mitral stenosis has good long-term results. The long-term outcome after this procedure can be predicted on the basis of patients' base-line characteristics.

Catheterization↗