Search PubMed⌕ Search

Biomedical subjects

R G Bach

Publications and source records attributed to R G Bach.

At least 55 records · Page 3Linked to original sources

Patterns of phasic coronary collateral flow velocity in patients.

Antegrade or retrograde collateral flow velocity Doppler signals, acquired with the flowire, permit the quantitation of collateral blood flow and its phasic patterns. The velocity spectra are easily visualized, and reproducible alterations during balloon occlusion may be directly related to coronary collateral flow-dependent variables of ischemia and left ventricular wall motion. The effects of pharmacologic stimulation on collateral flow remain under study.

Aged↗

Influence of adjunctive balloon angioplasty on coronary blood flow after rotational atherectomy.

Rotational atherectomy is being performed with increasing frequency in a distinct subset of patients whose lesion characteristics are unfavorable for conventional balloon angioplasty. Although satisfactory luminal enlargement can be accomplished with the use of rotational atherectomy alone in some patients, adjunctive balloon angioplasty is necessary in most patients, to obtain a minimal residual angiographic result. To demonstrate responses associated with rotational atherectomy results, serial coronary blood flow measurements were obtained in a patient undergoing rotational atherectomy for unstable angina. Adjunctive balloon angioplasty resulted in normalization of post-stenotic coronary flow reserve. Recanalization by rotablator alone may not normalize coronary flow despite a satisfactory angiographic result.

Aged↗

Comparison of pressure-derived fractional flow reserve with poststenotic coronary flow velocity reserve for prediction of stress myocardial perfusion imaging results.

The physiologic importance of coronary stenoses can be assessed indirectly by stress myocardial perfusion imaging or directly by translesional pressure and flow measurements. The aims of this study were to compare myocardial fractional flow reserve (FFRmyo), a recently proposed index of lesion significance derived from hyperemic translesional pressure gradients, with directly measured poststenotic flow velocity reserve for the prediction of myocardial perfusion stress imaging results in corresponding vascular beds. Poststenotic coronary flow velocity (0.018-inch guide wire) and translesional pressure gradients (2.7F fluid-filled catheter) were measured at baseline and after intracoronary adenosine (12 to 18 micrograms) in 70 arteries (diameter stenosis: mean 56% +/- 15%, range 14% to 94% by quantitative angiography). Coronary flow reserve was calculated as the ratio of hyperemic to basal mean flow velocity. FFRmyo was calculated during maximal hyperemia as equal to 1-(hyperemic gradient [mean aortic pressure-5]), where 5 is the assumed central venous pressure. Positive and negative predictive values and predictive accuracy for reversible stress myocardial perfusion abnormalities were computed. There was a significant correlation between pressure-derived FFRmyo and distal coronary flow reserve (r = 0.46; p < 0.0001). The strongest predictor of stress myocardial perfusion imaging results was the poststenotic coronary flow reserve (chi square = 33.2; p < 0.0001). The correlation between stress myocardial perfusion imaging and FFRmyo was also significant (chi square = 8.3; p < 0.005). There was no correlation between stress myocardial perfusion imaging and percentage diameter stenosis (chi square = 2.9; p = 0.10) or minimal lumen diameter (chi square = 0.47; p = 0.73). A poststenotic coronary flow reserve of < or = 2 had a positive predictive value of 89% for regionally abnormal myocardial perfusion imaging abnormalities, whereas the positive predictive values of FFRmyo and angiographic percentage diameter stenosis were only 71% and 67% respectively. In conclusion, the predictive value of poststenotic coronary flow velocity reserve for stress-induced myocardial perfusion abnormalities exceeds that of the translesional FFRmyo. These findings should be considered when applying these techniques for clinical decision making in the assessment of coronary stenosis severity.

Adult↗

Hemodynamic significance of coronary jet velocity in patients: limitations of the Bernouilli equation in small conduits.

The objective of this study was to assess the use of coronary stenosis velocity in the determination of translesional pressure gradients. In the physiologic assessment of coronary stenosis, the accelerated intracoronary flow velocity within a narrowing has correlated with minimal lesion cross-sectional area according to the continuity equation. In large conduits the jet velocity can determine pressure gradients when used in the Bernouilli equation. However, the use of intralesional flow velocity for calculation of translesional pressure gradients by the simplified Bernouilli equation (delta P = 4V2) may be inaccurate in small (< 5 mm diameter) conduits. Translesional pressure (2.2F catheter) and flow velocity (0.018-inch guidewire) were measured in a single coronary artery in 23 patients undergoing diagnostic angiography or angioplasty. The electronically determined mean of phasic proximal and distal pressure and planimetry of the instantaneous phasic pressure gradient were used and compared with the instantaneous velocity calculations of pressure by the simplified Bernouilli formula with both maximal jet velocity and a modified formula including proximal velocity. The mean measured translesional pressure gradient was 18 +/- 13 mm Hg (range 0 to 50 mm Hg) and was equivalent to the instantaneous average pressure gradient by planimetry. The maximal jet velocity was 125 +/- 40 cm/sec (range 63 to 250 cm/sec), yielding a calculated pressure gradient of 3 +/- 3 mm Hg. The calculated pressure gradient by the simplified Bernouilli equation correlated poorly with the measured translesional gradient (r = 0.27, F = 1.63, p = 0.21).(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Flow Velocity↗

Clinical outcome of deferring angioplasty in patients with normal translesional pressure-flow velocity measurements.

OBJECTIVES: The objective of this study was to determine the feasibility, safety and outcome of deferring angioplasty in patients with angiographically intermediate lesions that are found not to limit flow, as determined by direct translesional hemodynamic assessment. BACKGROUND: The clinical importance of some coronary stenoses of intermediate angiographic severity frequently requires noninvasive stress testing. Direct translesional pressure and flow measurements may assist in clinical decision making in patients with such stenoses. METHODS: Translesional spectral flow velocity (Doppler guide wire) and pressure data were obtained in 88 patients for 100 lesions (26 single-vessel and 74 multivessel coronary artery lesions) with quantitative angiographic coronary narrowings (mean +/- SD diameter narrowing 54 +/- 7% [range 40% to 74%]). Target lesion angioplasty was prospectively deferred on the basis of predetermined normal values, defined as a proximal/distal velocity ratio < 1.7 or a pressure gradient < 25 mm Hg, or both. Patients were followed up for 9 +/- 5 months (range 6 to 30). RESULTS: In the deferred angioplasty group, translesional velocity ratios were similar to those of a normal reference group (mean 1.1 +/- 0.32 vs. 1.3 +/- 0.55) and significantly lower than those of a reference cohort of patients who had undergone angioplasty (2.27 +/- 1.2, p < 0.05). The mean translesional pressure gradient in the deferred angioplasty group was also lower than that in the angioplasty group (10 +/- 9 vs. 45 +/- 22 mm Hg, p < 0.001). At follow-up in the deferred angioplasty group, four, six, zero and two patients, respectively, had had subsequent angioplasty, coronary artery bypass graft surgery or myocardial infarction or had died. In one patient, death was related to angioplasty of a nontarget artery lesion, and one patient with multivessel disease had a cardiac arrest due to ventricular fibrillation 12 months after lesion assessment. Among the 10 patients requiring later angioplasty or coronary artery bypass grafting, only six procedures were performed on target arteries. No patient had a complication of translesional flow or pressure measurements. CONCLUSIONS: These data demonstrate the safety, feasibility and clinical outcome of deferring angioplasty of coronary artery narrowings associated with normal translesional coronary hemodynamic variables. Given the practice of performing angioplasty without ischemic testing or when testing is inconclusive, translesional hemodynamic data obtained at diagnostic catheterization can identify patients in whom it is safe to postpone angioplasty.

Aged↗

Quantification of collateral blood flow during PTCA by intravascular Doppler.

The assessment of flow velocity using the Doppler guidewire provides a means of investigating both antegrade and retrograde blood flow in the coronary artery distal to obstructive lesions and occluding PTCA balloons. This has yielded unique qualitative and quantitative information regarding coronary collateral blood flow, and the responses of collaterals to pharmacological and haemodynamic perturbations. The current study analysed collateral flow velocity recordings obtained during coronary interventions in 46 patients in our laboratory. The mean collateral peak velocity integral distal to the occluding PTCA balloon was 9 +/- 7 units, while antegrade distal coronary peak velocity integral following stenosis relief by PTCA was 27 +/- 12 units. Thus, during PTCA balloon occlusion collaterals were able to supply a mean of 30 +/- 18% of the flow provided antegrade by successful PTCA. Variability in collateral flow velocity was not accounted for by differences in the PTCA artery assessed, the supply artery, the direction of collateral filling, the severity of coronary stenosis, or the angiographic grade of collaterals, and the magnitude of collateral flow velocity did not correlate with preserved left ventricular regional wall motion. The measurement of collateral flow velocity by intravascular Doppler provides unique and quantitative information regarding the coronary collateral circulation.

Angioplasty, Balloon, Coronary↗

Intracoronary Doppler flow velocity measurements for the evaluation and treatment of coronary artery disease.

The functional significance of coronary artery disease is often inadequately revealed by the solely anatomic information provided by coronary angiography, especially with respect to intermediate-severity stenoses and the complex lesions that result from percutaneous coronary intervention. The clinical application of coronary flow velocity measurements using the Doppler flow wire during cardiac catheterization represents a promising means for providing immediate physiologic assessment of coronary artery lesion significance. Recent correlations with translesional hemodynamics and noninvasive perfusion imaging have confirmed the accuracy and reliability of Doppler translesional flow velocity assessment. The use of intracoronary flow velocity data for functional assessment can refine the selection of patients for revascularization. Furthermore, measurements of translesional and distal coronary flow velocity dynamics during procedures provide immediate data regarding the physiologic adequacy of the intervention. The information provided by the analysis of coronary blood flow using the Doppler guide wire can serve to improve the diagnostic and therapeutic capabilities of interventional cardiology.

Angioplasty, Balloon, Coronary↗

Immunohistochemical characterization of immune cell composition and cytokine receptor expression in human coronary atherectomy tissue.

BACKGROUND: Prior histologic studies have examined smooth muscle cell, macrophage and thrombus constituents of atherosclerotic coronary atherectomy specimens. Lymphocytes and mononuclear leukocytes are also detectable in atherosclerotic surgical pathology specimens utilizing immunocytochemical techniques. METHODS: In order to quantify the histological contribution of cytokine receptor-expressing immunocompetent cells to human coronary artery stenoses, 30 directional atherectomy catheter biopsy specimens (wet weight < or = 10 mg) from 16 patients were snap frozen (-70 degrees C) for quantitative immunocytochemical studies. Following computer-assisted quantification of total intimal nuclei per tissue section (mean 297 +/- 177; cell density 7 +/- 5/10(4) microns 2), monoclonal antibody cytochemistry was used to identify the percentage of these cells expressing antigenic clusters of differentiation (CD) characteristic of T-lymphocytes, B-lymphocytes and monocytes. Identification of alpha (low affinity) and beta (intermediate affinity) interleukin-2 receptors on intimal cells was accomplished using a three-step streptavidin-biotin method. RESULTS: A significant percentage of intimal cells were of lymphocytic (11 +/- 13%) or monocytic (12 +/- 14%) origin, with helper T-cells (9 +/- 12%) outnumbering both suppressor T-cells (2 +/- 4%) and B-lymphocytes (1 +/- 2%). Interleukin-2 receptors were noted on 9 +/- 12% of intimal cells, including cells with a vascular smooth muscle phenotype. CONCLUSIONS: These quantitative immunocytochemical data conclusively demonstrate that lymphocytes and monocytes account for over 20% of coronary plaque cells obtained by in-vivo atherectomy, and that helper (CD4) T-cells predominate over suppressor (CD8) T-cells and B-lymphocytes. Variable interleukin-2 receptor subtype expression occurs in mononuclear leukocytes infiltrating chronic human atheroma. By applying these techniques, the therapeutic effects of cytotoxic agents on selectively targeted cytokine receptor-expressing cells may now be evaluated in vivo in small human directional coronary atherectomy specimens.

Adult↗

Translesional pressure-flow velocity assessment in patients: Part I.

Interventional physiology presents the operator with objective data to facilitate decision making. A thorough and validated understanding of the alterations of pressure and flow in the human coronary circulation is currently in progress. As illustrated in the case studies, some situations have data which may initially appear contradictory or unhelpful to clinical practice. These data should provide a framework to understand the dynamic physiology producing the clinical syndromes in patients undergoing coronary interventional procedures. Future Interventional Physiology Rounds will examine coronary pressure-flow responses during directional atherectomy, stents, and acute myocardial infarction.

Adult↗

Alterations of coronary flow velocity during intervention for acute myocardial infarction: responses to complications of intracoronary thrombolysis and angioplasty.

Alterations, either an increase or decrease, in the distal flow velocity over time are associated with alterations in vessel diameter and/or unstable flow velocity. Unexplained unstable flow velocity patterns should act as early warning signs to prompt the interventionalist to assess continued coronary patency and need for renewed interventions.

Angioplasty, Balloon, Coronary↗

Limitations of translesional pressure and flow velocity for long ostial left anterior descending stenoses.

Translesional pressure and flow velocity can be used to assess angiographically intermediate or indeterminate lesions. Ostial narrowings and long lesions represent situations that may require both pressure and flow velocity assessment. In patients with hypertension, diabetes mellitus, and chronic renal failure, distally measured absolute and regional coronary reserve values alone may not be helpful in selecting lesions requiring intervention.

Adult↗

Approach to total occlusion of an aorto-ostial "Y" saphenous vein graft with anterior descending graft limb stenosis by serial balloon angioplasty and elective stent deployment.

Coronary revascularization using balloon angioplasty and stent placement for unstable angina was performed in a 74-year-old woman with an aorto-ostial occlusion of a "Y-type" saphenous vein graft and a severe stenosis in the body of a 14-year-old left anterior descending saphenous vein graft. Multiple prior coronary bypass graft surgeries, location of branch graft lesions, and length of the ostial stenosis must be considered in selecting the approach to revascularization.

Aged↗