Error detection of high concentrations of endogenous free glycerol in determination of serum triglyceride with the TBA-80S automated discrete analyzer.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Fushimi.
Explore the source record for details and available documents.
We established a simple and rapid enzymatic method for measuring potassium ion in serum by using tryptophanase (EC 4.1.99.1) purified from Escherichia coli K12 strain (E. coli K12 IFO 3301). The presence of pyridoxal 5-phosphate promotes this enzymatic reaction, and potassium and (or) ammonium ions further accelerate it, with ammonium and potassium ions providing equivalent acceleration. We eliminated endogenous ammonium ion by using glutamate dehydrogenase (GLDH; EC 1.4.1.4), then produced ammonium ion in the presence of tryptophanase, tryptophan, and pyridoxal 5-phosphate. The concentration of formed ammonium ion, which was proportional to that of potassium ion in sample, was determined by adding GLDH to produce NADP+ in the presence of 2-oxoglutarate and NADPH; we then read the change of absorbance at 340 nm. The standard curve was linear for potassium ion concentrations up to 7.00 mmol/L. The within-assay variation (CV) was 0.89% at 5.51 mmol/L and 1.32% at 3.37 mmol/L. The day-to-day CVs were 0.99% at 6.85 mmol/L and 1.71% at 3.52 mmol/L. Analytical recoveries ranged from 98.7% to 108.9%. The correlation coefficient between values obtained with this enzymatic assay (y) and by flame photometry (x) was 0.995: y = 0.984x + 0.091 mmol/L (Sy.x = 0.105, n = 100). The presence of hemoglobin, bilirubin, or other cations little affects this system.
We experienced an abnormal blood sample which showed larger numbers of white blood cells and platelets counted by the electric resistance system and of platelets in mechanical counting by the flow system, than those in manual counting. Many precipitates were observed in this blood sample at room temperature or 4 degrees C, but were not observed at 37 degrees C. The precipitates were clarified to be caused by the mixed type (IgA, IgG and IgM) cryoglobulin by using an immunofluorescence method and an ouchterlony method. These data indicate that precipitation of cryoglobulin at room temperature induce falsely high value of platelet count in mechanical counting systems.
We examined an inhibitor to factor VIII in non-haemophilic patient who had been developed widely spread ecchymosis and intramuscular bleeding. He had no previous personal or family history of abnormal bleeding tendency. His laboratory data was all normal except examination for blood coagulation. Coagulation studies showed prolonged activated partial thromboplastin time (48 sec) and decreased factor VIII activity (8%). The activity of the inhibitor to factor VIII was demonstrated to be 4.0 Bethesda unit. By the studies of dilution and time response curve, this inhibitor was found to inhibit up to 90% of factor VIII activity but not 100%. This inhibitor was shown to be IgG by protein-A affinity chromatography. In addition, bleeding time was prolonged in the patient. The value of von Willebrand factor antigen was 200%, but that of Ristocetin cofactor was 93%. Since the gel filtration analysis indicated that this inhibitor also suppressed Ristocetin cofactor activity, the relatively low value of Ristocetin cofactor might occur through the action of the inhibitor. These data suggest that patient's inhibitor react to factor VIII high molecular subunit.
Immunoreactive digoxin-like activity was observed in Chinese medicine, KYUSHIN tablet, taken popularly in Japan without prescription. The antibodies used in the assays of digoxin reacted with Chan-su, the major effective component of KYUSHIN, which contained cardiotonic steroids with similar chemical structure as digoxin. One tablet of KYUSHIN had digoxin-like immunoreactivity equivalent to 1.9, 1.5, and 72 micrograms of digoxin measured by three different commercial kits. These different equivalences may be attributed to differences in cross-reactivity of the antibody used in the immunoassays. Two healthy volunteers took two KYUSHIN tablets three times a day, a typical dose, and digoxin-like immunoreactivity reached almost 0.4 micrograms/L in 0.5 day. Therapeutic drug monitoring should be interpreted carefully in patients taking Chinese medicines, many of which contain the Chan-su component.
Explore the source record for details and available documents.
As a part of studies concerning clinical application of the measurement of urinary iodide with an iodide-selective ion electrode, we report here the reference values for the iodide content or concentration in morning spot urine specimens from normal subjects of varying ages and studies with patients with thyroid diseases in Japan. The number distribution of the iodide content or concentration in the morning specimens appeared logarithmic normal in adults, children and infants. Normal ranges found in 95 per cent of populations of healthy subjects were 5.3 to 62.0 mumoles/g Creatinine (Cr) for adults, 5.3 to 42 mumoles/g Cr for children, and 1.9 to 56 microM for infants, respectively. Urinary iodide concentrations in breast-fed infants varied widely compared with those in bottle-fed infants. Mean values were 16.4 microM for breast-fed infants and 8.6 microM for bottle-fed infants, and they were not statistically different. Urine samples from the infants with transient hypothyroidism, who had undergone amniofetography showed extraordinarily high iodide concentrations, even though they were measured at 20th, 29th and 30th days after birth. Although urinary iodide excretion in patients with simple goiter was within normal limits, the mean was statistically lower than that in normal controls (p less than 0.001). Because of the simplicity and rapidity of the electrode method, we strongly recommend it for use in examining iodide excretion in patients with various thyroid diseases.
Explore the source record for details and available documents.
A simple and rapid way to measure the concentration of iodide in urine with an iodide-selective ion electrode was described. Potentiometric equilibrium was attained in less than 5 min, and a linear calibration curve was obtained over the potassium iodide (KI) concentration range of 10(-2) to 10(-6) M. The coefficients of variation ranged from 6.2 to 10.0% within assay, and 5.4 to 14.4% between assays. The serial dilution of 3 urine samples with different concentration of iodide showed good linear correlations passing through zero. In practice, the chloride ions in urine did not cause serious errors in the measurement of iodide at molar ratios of chloride ion to iodide up to 2 X 10(4). A good linear correlation was obtained between iodide concentrations in urine determined by the electrode method and by the conventional chemical method (r = 0.92). A linear correlation was also observed between the iodide concentrations of 24 h collected urine and those of single morning urine (r = 0.91). The normal iodide content in single morning urine specimens from 127 Japanese people was 5.3 to 62.0 X 10(-6) moles/g creatinine.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.