Search PubMed⌕ Search

Biomedical subjects

R F Edlich

Publications and source records attributed to R F Edlich.

At least 433 records · Page 24Linked to original sources

Accidental hypothermia: a potential life-threatening hazard of automobile platform lifts.

The wheelchair/scooter of a patient with a relapsing-remitting form of multiple sclerosis was immobilized after inadvertent slippage of the rear wheels of his scooter off an automobile platform lift during travel. While waiting 45 min for the rescue squad, he developed mild hypothermia that responded to passive external rewarming techniques. This potentially life-threatening injury could have been prevented by using a platform lift equipped with full inboard and outboard roll-stop barriers on the platform.

Automobiles↗

Natural rubber latex allergy: spectrum, diagnostic approach, and therapy.

Latex allergy has reached epidemic proportions in the United States and is increasingly recognized as a significant contributor to morbidity and mortality during medical and surgical procedures. Ultimately, many of the affected patients with recognized latex sensitivity and those who are not yet diagnosed will receive treatment for their allergic reactions to latex in emergency departments. Consequently, emergency physicians must have a comprehensive understanding of the etiology, epidemiology, pathogenesis, treatment, and management of these challenging patients. Groups at high risk include spina bifida cystica patients, health care workers, latex industry workers, specific food-allergy patients, and patients with a history of atopy or multiple surgical procedures. Sensitization to latex antigens is commonly encountered in health care workers wearing latex gloves with high latex allergen concentrations and in workers using powdered latex surgical gloves. Exposure to air-borne allergens and water-soluble IgE reactive latex antigens from natural rubber latex products in sensitized individuals can result in type I (immediate) hypersensitivity reactions. Clinical manifestations include contact urticaria, dermatitis, allergic rhinitis, conjunctivitis, asthma, angioedema, and anaphylaxis. Diagnostic tools include serological assays and skin prick testing. At present, latex avoidance is the only available treatment and is the key to preventing allergic reactions in latex-sensitized individuals. Health care worker sensitization to latex antigens in natural rubber products is becoming an increasing contributor to workers' liability and disability claims. Specific action can be taken to reduce occupational and patient exposure to latex antigens.

Anaphylaxis↗

Surgical glove lubricants: from toxicity to opportunity.

In most emergency departments, surgical gloves are coated with surface powders that act as lubricants to facilitate donning. Cornstarch powder is an absorbable powder employed as a donning agent on most powdered gloves. Talcum powder, a nonabsorbable powder, is used as a mold release agent in glove manufacture and is still commonly found on the surfaces of modern surgical gloves. These powders are foreign bodies that elicit inflammatory responses, leading to a wide number of symptoms and complications. The best method of preventing clinical complications from glove powder is to use powder-free gloves.

Gloves, Surgical↗

Wangensteen's transformation of the treatment of intestinal obstruction from empiric craft to scientific discipline.

Dr. Owen Wangensteen, who is considered by many to be the greatest surgical educator of the 20th century, is recognized for his revolutionary studies of intestinal obstruction. He defined the criteria for the early diagnosis of intestinal obstruction with the aid of a stethoscope and X-ray examination. Moreover, be discovered that suction through a nasal catheter extended to the stomach could relieve the distention by gas as effectively as enterostomy. In his innovative studies, Dr. Wangensteen reduced the mortality from intestinal obstruction from more than 60% to 5%.

General Surgery↗

Industrial high-voltage electrical burn of the skull, a preventable injury.

Deep burns of the scalp and skull are often caused by high-voltage electrical injuries. Patients with such injuries should be referred to regional burn centers that are prepared to excise necrotic burn tissue and cover the devitalized bone with a well-vascularized flap. Strategies for prevention of these electrical burns are discussed.

Accidents, Occupational↗

Technical considerations in knot construction. Part I. Continuous percutaneous and dermal suture closure.

The purpose of this investigation was to determine the security of the square knot tied with one looped end and one free end versus the security of the square knot tied with two free ends. Size 4/0 and size 6/0 monofilament nylon, polypropylene, and Biosyn sutures were selected for this evaluation. The mechanical performance of these sutures was judged according to knot breakage force and number of throws required to attain security. Knots with one looped end and one free end require more throws to ensure knot security than do knots constructed from two single suture strands of comparable sizes and types of sutures.

Caprolactam↗

Search for a scientific basis for continuous suture closure: a 30-yr odyssey.

Continuous percutaneous and dermal suture closures have an important role in the approximation of long, linear lacerations in the emergency department. This report documents the scientific basis for these continuous closure techniques. In addition, a detailed description of these surgical closure techniques is presented.

Evidence-Based Medicine↗

Technical considerations in knot construction. Part II. Interrupted dermal suture closure.

The purpose of this study was to identify the optimal knot construction for interrupted dermal sutures. A synthetic braided absorbable suture, sizes 3-0 and 5-0, was selected for this evaluation. With reproducible mechanical performance tests, we determined that the construction of secure knots without ears required one additional throw as compared with secure knots with 3-mm ears. The direction of applied tension did not alter knot security, with the exception of granny knots, which required an extra throw when tension was applied parallel to the suture loop. Because interrupted dermal knot construction is accomplished without knot ears and with an applied tension parallel to the wound, one additional throw must be added to the knot to ensure knot security.

Humans↗

Metacarpophalangeal joint dislocation: indications for open surgical reduction.

In complex dislocations of the metacarpophalangeal joint, the volar plate is separated from the proximal phalanx and the metacarpal head is entrapped within surrounding tissue structures. These complex dislocations must be managed by open surgical reduction to reduce the dislocation and realign the volar plate. A 58-year-old male presented to the emergency department with a complex dislocation of the metacarpophalangeal joint of the left little finger, which was successfully treated by open reduction in the operating room. The indications for open reduction of metacarpophalangeal joint dislocations are reviewed.

Collateral Ligaments↗

Molten metal burns: further evidence of industrial foundries' failure to comply with Occupational Safety and Health Administration regulations.

The purpose of this report is to describe another case of a molten metal burn to the foot of a foundry worker. The foundry in which he worked failed to comply with Occupational Safety and Health Administration regulations with regard to protective apparel. This injury could have been prevented with annual, unscheduled inspections by the Occupational Safety and Health Administration and with enforcement of additional regulations regarding protective apparel.

Accidents, Occupational↗

Biomechanical performance of cutting edge surgical needles.

The purpose of this study was to compare the biomechanical performance of cutting edge needles made of S45500 stainless steel alloy to Surgalloy stainless steel. The new high-nickel stainless steel alloy, Surgalloy, has superior performance characteristics over that of the other high-nickel stainless steel alloy, S45500. The Surgalloy needle is produced from a stronger stainless steel alloy than the S45500 needle. The Surgalloy needle has considerably greater resistance to bending than the needle produced from S45500 alloy. In addition, Surgalloy stainless steel has almost a twofold greater resistance to fracture than the S45500 stainless steel alloy.

Biomechanical Phenomena↗

Asymptomatic jaundice after fasting: a diagnostic dilemma.

An 18-year-old female with asymptomatic jaundice presented to the emergency department after fasting. She was referred to the regional medical center for evaluation and treatment. The diagnosis of Gilbert's syndrome was made by fractionation of serum unconjugated and conjugated bilirubin fraction by alkaline methanolysis, followed by thin-layer chromatography and analysis of fasting-state levels of cholyl conjugated bile acids. Methods for diagnosing this disorder are discussed.

Adolescent↗

Magnetic resonance imaging in the early diagnosis of group A beta streptococcal necrotizing fasciitis: a case report.

Early diagnosis of invasive group A beta streptococcal (GABS) infection has been achieved in a patient using magnetic resonance imaging (MRI) complemented by needle aspiration. Life-saving treatments of GABS infection that include immediate surgical debridement along with the administration of i.v. antibiotics, gamma globulin, and hyperbaric oxygen were then implemented successfully to prevent the development of streptococcal toxic shock syndrome. While MRI is valuable in making early diagnosis of GABS, it should not delay surgical intervention.

Biopsy, Needle↗

Inadequate standard for glove puncture resistance: allows production of gloves with limited puncture resistance.

The National Fire Protection Association has developed standards for glove puncture resistance using a metal puncture probe. Biomechanical performance studies have demonstrated that glove puncture resistance to the probe is significantly greater than that of the hypodermic needle, suggesting that these standards have no clinical relevance. These standards give a false sense of security to health care personnel and sanction the production and use of gloves that give inadequate protection. The result is potentially harmful for medical personnel.

Equipment Design↗

Technical considerations in knot construction, part III. Knot asymmetry.

Lactomer and the Polyglactin 910 are coated synthetic braided absorbable sutures commonly used for dermal wound closure. Biomechanical performance tests demonstrated superior performance characteristics of the Lactomer sutures. Using narrow diameter sutures, the Lactomer sutures exhibited superior knot holding forces over the Polyglactin 910 sutures. Moreover, knot security could be reliably achieved with asymmetric and symmetric knots using the Lactomer sutures.

Biomechanical Phenomena↗

"Scientific basis of wound closure techniques." Evaluation of a new training program.

A formal training program in wound repair entitled "Scientific Basis of Wound Closure Techniques" has been developed and is accredited by the Dannemiller Memorial Educational Foundation. This course is now available at no cost to medical schools, residencies, and continuing education programs for graduate physicians. A manual with its complementing videotape allow the course participant to gain the necessary psychomotor skills to repair wounds. Evaluation of the course taken by third-year medical students and first-year residents demonstrates a high level of satisfaction. After instituting the course, there was a noticeable change in the types of barriers, instruments, and wound closure techniques practiced in our emergency department.

Education, Medical, Continuing↗