Search PubMed⌕ Search

Biomedical subjects

R F Edlich

Publications and source records attributed to R F Edlich.

At least 415 records · Page 23Linked to original sources

Electric heating pad burns.

Patients with sensory deficits are especially prone to heating pad burns. Two cases are reported of patients with anesthetic skin who received partial and full-thickness burns of their feet from an electric heating pad. These burn injuries could have been prevented if the patients understood the potential hazard of heating pads.

Adult↗

Human T-cell lymphotrophic virus type-I (HTLV-I) retrovirus and human disease.

Human T-cell lymphotrophic virus type-I (HTLV-I) was the first pathogenic retrovirus identified in humans. HTLV-I is now linked to a number of clinical diseases, most notably adult T-cell leukemia/lymphoma and the syndrome known as HTLV-associated myelopathy or tropical spastic paraparesis (HAM/TSP). For the emergency physician practicing among patients from high-risk groups, HTLV-I infection and its associated diseases are presenting an increasing challenge. This report describes its transmission, seroprevalence, associated diseases, and methods to control the spread of this retrovirus.

Counseling↗

A serious skin sulfur mustard burn from an artillery shell.

Despite the Geneva Protocol of 1925 and the Paris Conference on Prohibition of Chemical Weapons in 1989, sulfur mustard and other chemical weapons continue to pose a hazard to both civilians and soldiers. The presence of artillery shells containing sulfur mustard, both in waters where these shells were dumped and in old battlefields, presents a problem in times of peace, especially for those who collect wartime memorabilia. Past literature has reported several hundred incidents involving fishermen who inadvertently pulled leaking shells aboard their fishing vessels, thereby exposing themselves to the vesicant chemical. Other literature reports exposure to children who found the chemical shells in old battlefields. The purpose of this article is to report the first case of a serious sulfur mustard burn that occurred after removing the detonator from an old artillery shell in a historic battle field near Verdun, France. The circumstances surrounding the injury, the diagnosis and management of injuries secondary to sulfur mustard, and the long-term consequences to the patient are presented and discussed. Although skin grafting has been used in the management of other chemical burn injuries, this report is the first to describe the need for split-thickness skin grafts in the management of a patient with sulfur mustard burns.

Burns, Chemical↗

Considerations in the selection of surgical gloves for tape wound closure.

One of the reasons that tape closure of wounds is rarely used in the emergency department is that it is difficult for the emergency physician wearing powdered, latex gloves to handle skin closure tapes. Because the skin closure tapes adhere aggressively to powdered latex gloves, it is difficult for the emergency physician to separate the tape from his glove and apply the tape to the skin. The advent of a new powder free glove allows the emergency physician to handle the tapes and accomplish tape wound closure.

Adhesiveness↗

Ease of donning surgical gloves: an important consideration in glove selection.

It is a commonly held belief among physicians that powder free surgical gloves are more difficult to don than cornstarch powdered gloves. This difficulty is supposedly enhanced when the physician's hands are wet, a situation commonly encountered when regloving during surgical procedures. This investigation dispels these beliefs by demonstrating that the forces required to don powder free gloves do not differ significantly from those required to don gloves coated in cornstarch lubricant. Moreover, Biogel, a new powder free glove with an inner hydrogel lining, is shown to don easily and safely without ripping, even with wet hands, a circumstance not encountered with other gloves.

Emergency Medicine↗

A new glove puncture detection system.

A new glove detection system has been developed for early and accurate detection of a hole in the glove. It consists of an inner glove colored by a green dye and outer glove. When a breach in the outer glove occurs, the inner glove develops a dark patch around the needle puncture hole, a visible indicator for immediate glove change. Using a computerized needle penetration system, the immediate and maximal penetration forces as well as the work required for needle penetration of this new double glove was significantly greater than those encountered with either the inner or outer glove tested separately. In addition to hole detection, this double glove provides increased protection against needle penetration.

Coloring Agents↗

A new powder-free glove with a textured surface to improve handling of surgical instruments.

A latex surgical glove has been designed to have a textured surface that stimulates the surface of intact skin. This textured surface enhances security of grasp of surgical instruments under wet and dry conditions without altering tactile discrimination. The unique hydrogel polymer of this glove allows the glove to be donned with either wet or dry hands without the use of cornstarch lubricants.

Evaluation Studies as Topic↗

Anaphylaxis after laboratory rat bite: an occupational hazard.

Workers exposed to laboratory animals are at risk of developing asthma, rhinitis, angioedema, conjunctivitis, and urticaria. Approximately one in five scientists and technicians handling small animals will develop laboratory animal allergy symptoms within three years of employment, many of whom will have severe symptoms requiring a change of occupation. Individuals suffering from allergy to environmental allergens, such as pollen and ragweed, are more likely to develop allergic reactions to animals, and are more likely to develop asthma. We report a case of life-threatening anaphylaxis secondary to a rat bite in a laboratory research director with known allergies to rat urinary protein. While rodent bites are common in research settings, such severe reactions are extremely rare.

Accidents, Occupational↗

Another cause of surgical needle holder damage to surgical sutures.

The sharp edges of the box lock of the needle holder can inadvertently damage the suture during instrument ties. Compression of a monofilament nylon suture between the sharp edges of the box lock of a surgical needle holder damages the suture, reducing its breaking strength. This adverse effect has been eliminated by one manufacturer whose needle holder box lock has rounded edges and sufficient space to permit passage of the suture.

Equipment Design↗

Enhancing needle durability by silicone coating of surgical needles.

The purpose of this study was to assess the effect of coating surgical needles with silicone on their durability. Needle durability is a measure of needle sharpness after repeated passage through tissue. Needle sharpness was determined by quantitating the energy required to pass a designated needle repeatedly (20 times) through porcine skin, linea alba, colon, and aorta. The results demonstrate that the durability and sharpness of silicone-coated needles were significantly greater than those of comparable uncoated needles in linea alba, colon, and aorta, but not in skin.

Animals↗

Grease burns of the hand: preventable injuries.

Grease burns to the hand represent a serious and preventable hazard. These injuries account for over 10% of all major burns seen in the emergency department. These burns occur when the cook attempts to move a pan with burning cooking oil and inadvertently spills the oil on the hand holding the pan. These burns are usually full thickness because of either the high temperatures of the flaming oils or the subsequent ignition of clothing. This article describes a patient who received severe partial and full thickness burns to the dominant hand following a grease burn in the domestic setting. Prevention through improved consumer education and warning labels for cooking oils should reduce the incidence of these serious injuries.

Accidents, Home↗

Steam press hand burns: a serious burn injury.

Steam presses cause full-thickness burns when the operator's extremity is caught between the buck and the head of the steam press. Patients with serious steam press burns should be referred to a regional burn center for excision of the full-thickness burn and coverage by either a split-thickness skin graft or a flap. The safety features in steam presses that could prevent this serious injury include: (1) emergency safety releases, (2) peripheral safety bars, and (3) two-hand operator control.

Accidents, Occupational↗

Chondritis of the ear: a late sequela of deep partial thickness burns of the face.

Chondritis of the ear is a late sequela of deep partial thickness burns of the face. It is the purpose of this article to describe two patients who came to the emergency department 21 days and 35 days after sustaining deep partial thickness burns of the face from explosions. The patients were hospitalized for incision and drainage of the infected wound that included excision of the infected cartilage complemented by systemic antibiotic therapy.

Adolescent↗

Status of Voicetype Dictation for Windows for the emergency physician.

The purpose of this study is to assess the accuracy of the IBM VoiceType Dictation emergency medicine vocabulary domain under several conditions. The vocabulary domain, microphone position, and background noise markedly reduce dictation accuracy. Consequently, this voice recognition system is impractical in an emergency department setting.

Cost-Benefit Analysis↗