In vivo performance of a matrix-based quantitative ultrasound imaging device dedicated to calcaneus investigation.

We developed a prototype of an ultrasound (US) bone matrix densitometer, the BEAM scanner, in the context of a European Space Agency research program. This device, which is a contact imaging device, was designed to overcome the limitations of immersion devices in space. Broadband US attenuation (BUA) and speed of sound (SOS) parameters were calculated from the radiofrequency (RF) signal. The principle aim of this study was to evaluate in vivo performance in direct comparison with a currently available device (UBIS 3000, DMS, France). The short-term precision of the BEAM scanner for BUA was estimated at 2.8%, whereas it was 2.3% with UBIS 3000. The short-term precision for SOS was 0.3%, and this was the same as the coefficient of variation (CV) of the UBIS 3000. CVs of 3.4% and 0.6% for midterm precision were found for BUA and SOS, respectively, and UBIS 3000 scores were 3% and 0.4%, respectively. This preliminary study demonstrates the high performance of the BEAM scanner and its new concept offers a wide range of improvements and new applications.

Adult↗

Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: relationships to density and microstructure.

The present study was designed to evaluate the relationships between ultrasonic backscatter, density, and microarchitecture of cancellous bone. The slopes of the frequency-dependent attenuation coefficient (nBUA), ultrasound bone velocity (UBV), the frequency-averaged backscatter coefficient (BUB) were measured in 25 cylindrical cancellous bone cores. Bone mineral density (BMD) was determined using X-ray quantitative computed tomography. Microarchitecture was investigated with synchrotron radiation microtomography with an isotropic spatial resolution of 10 microm. Several microstructural parameters reflecting morphology, connectivity, and anisotropy of the specimens were derived from the reconstructed three-dimensional (3D) microarchitecture. The association of the ultrasonic variables with density and microarchitecture was assessed using simple and multivariate linear regression techniques. For all ultrasonic variables, a strong association was found with density (r = 0.84-0.90). We also found that, with the exception of connectivity, all microstructural parameters correlated significantly with density, with r values of 0.54-0.92. For most microstructural parameters there was a highly significant correlation with ultrasonic parameters (r = 0.33-0.91). However, the additional variance explained by microstructural parameters compared with the variance explained by BMD alone was small (Delta r(2) = 6% at best). In particular, no significant independent association was found between microstructure and backscatter coefficient (a microstructure-related ultrasonic parameter) after adjustment for density. The source for the unaccounted variance of quantitative ultrasound (QUS) parameters remains unknown.

Aged↗

Effect of articular cartilage proteoglycan depletion on high frequency ultrasound backscatter.

OBJECTIVE: To study the effect of variations of articular cartilage proteoglycans (PG) on high-frequency ultrasound backscatter. DESIGN: The study was performed on patellar cartilages of immature and mature rats (N=36). The variation of PG content was induced by enzyme digestion. Control and treated cartilages were explored in vitro using a 55MHz scanning acoustic microscopy, then assessed by histology for the fibrillar collagen organization analysis. The variations of proteoglycan and collagen content were evaluated. Thickness measurements performed on both B-scan images and histologic sections were compared. Ultrasonic radio-frequency signals reflected by the cartilage surface and backscattered from its internal matrix were processed to estimate the integrated reflection coefficient (IRC) and apparent integrated backscatter (AIB). RESULTS: Although hyaluronidase treatment of immature and mature cartilages removed approximately 50% of the proteoglycans, the echogenicity level of ultrasound images of degraded cartilages was similar to that of controls. IRC and AIB parameters did not significantly vary. Histologic sections of degraded cartilage displayed no change in collagen fiber organization. The thickness mean values measured by ultrasound in PG-depleted groups were significantly higher than in controls, whereas no significant difference in thickness was detected by histological measurement. The increase in cartilage thickness may potentially be explained by a decrease of speed of sound in PG-depleted cartilages that is more likely subsequent to an increase of water content. CONCLUSION: Current results indicate that PG depletion has no significant effect on high frequency ultrasound backscattered from rat patellar cartilage. Ultrasound may provide information about variations of PG content via speed of sound measurement.

Acoustics↗

Contrast and velocity ultrasonic tomography of long bones.

Our objective is to derive quantitative sound speed images of cortical bone using ultrasonic transmission tomography. Cortical bone is a highly refracting medium, i.e., the sound velocity changes abruptly across the interface between soft tissue and bone. It results in a loss of data compared to classical tomography in soft tissues. In order to correct for degradation by refraction effects, the classical acquisition procedure of projection data is modified: the transducers are oriented according to Snell's law of refraction with the aim of optimizing the sound propagation as parallel longitudinal rays inside the bone. This strategy allows the subsequent application of straight-ray reconstruction by the backprojection technique, which is a classical procedure in x-ray tomography. The method is validated with Plexiglas solid cylinders and tubes immersed in water. Improved sound velocity images are then derived using conventional Radon transform of the experimental time-of-flight data. The method is then extended to in vitro human femur immersed in water. The geometry of the bone cross-section is reconstructed from measurements using ultrasonic reflection tomography. The result is then introduced in the calculation of the position and orientation of the transducers, which are associated with the parallel acoustical paths in bone in the transmission measurements. The procedure leads to significant restoration enhancement over the non corrected image. The mean value of the velocity of 3,200 ms(-1) in the cortical shell is consistent with the values known from literature. These preliminary quantitative images using combined reflected and transmission ultrasound show promise for bone imaging.

Elasticity↗

Reproducibility of skin characterization with backscattered spectra (12--25 MHz) in healthy subjects.

Ultrasonic techniques were developed for quantitative in vivo analysis of skin composition based on measurements of apparent integrated backscatter (IBS) and its frequency dependence (n) between 12.5 and 25 MHz. Parameters were measured at five depths in healthy dermis of the midforearm of 29 volunteers (13 women, 16 men, 20 to 76 years old) on three different days. Reproducibility of measurements was evaluated (standardized coefficients of variation: 7% to 11% for IBS and 9% to 20% for n). Parameter values were significantly influenced by pressure of the ultrasonic probe on the skin, and both room and skin-surface temperatures were correlated to IBS measured in a single subject on 28 days. More precise control of these factors could further improve measurement reproducibility and sensitivity to skin composition. Significant (p < 0.05) differences of parameter values with respect to region of interest depth, age and gender of subjects were discussed in comparison with dermal composition and offer promise that these parameters could be used to characterize skin modifications.

Adult↗

Assessment of rat articular cartilage maturation using 50-MHz quantitative ultrasonography.

OBJECTIVE: The objective was to assess the relationship between maturation-related structural changes of articular cartilage and variations of acoustic parameters estimated using high frequency ultrasonography. DESIGN: Patellae taken from 48 immature Wistar male rats and divided into six age groups (from five to 11 weeks old) were explored in vitro using 50-MHz scanning acoustic microscopy, then assessed by histology for the analysis of the cartilage cell distribution and fibrillar collagen organization. The variation of cartilage proteoglycan and collagen content with age was evaluated. Thickness measurements performed on both B-scan images and histologic sections were compared. Ultrasonic radiofrequency signals reflected by the cartilage surface and backscattered from its internal matrix were processed to estimate the integrated reflection coefficient (IRC) and apparent integrated backscatter (AIB). RESULTS: One-way ANOVA indicated that acoustic parameters and thickness change significantly (P < 0.05) as the animal matures because of age-related changes in cartilage composition and morphology. A moderate correlation was found between IRC and the animal age. The parameter decreased slightly but significantly over time. However, a good correlation was observed between the rat age and the AIB, which decreased significantly over time. The parameter variation was mostly related to the changes in collagen fiber orientation, and/or to a change in cell size, density and organization. CONCLUSIONS: Current results indicate that acoustic properties of cartilage are affected by maturation-related cartilage changes. This suggests that high frequency ultrasonography may serve as a useful means for the investigation of cartilage matrix structural changes occurring under various clinical circumstances, like those observed during osteoarthritis, and for the evaluation of the efficacy of specific therapeutics.

Aging↗

Ultrasonic backscatter and transmission parameters at the os calcis in postmenopausal osteoporosis.

Ultrasound technology has emerged as a new tool in the assessment of osteoporosis. Ultrasound parameters usually are measured in transmission; there is a potential for the analysis of backscattered signals to provide information on bone microarchitecture. The aim of this study was to explore a new technological development of the method, adding backscatter coefficient to transmission parameters, and to examine the appropriate thresholds to identify postmenopausal osteoporotic women. We examined 210 postmenopausal women (including 60 with osteoporotic fractures) and 30 healthy premenopausal controls. They had lumbar spine and hip bone mineral density (BMD) measurement and quantitative ultrasound (QUS) evaluation at the os calcis, measured in transmission (broadband ultrasound attenuation [BUA], speed of sound [SOS], ratio of transit time [dt] to BUA [dt/BUA], and "strength" index [STI]) and reflexion (broadband ultrasound backscattering [BUB]). The standardized CVs (sCVs) were between 2.27 % and 3.40 % for QUS measured in transmission and 4.41% for BUB. The odds ratio (OR) for fracture discrimination adjusted for age was 2.77 for hip BMD and between 1.6 and 2.9 for QUS. After adjustment for hip BMD, ORs were still highly significant for SOS, STI, and dt/BUA. According to hip BMD T score, prevalence of osteoporosis in our population was 39%. To detect the same prevalence, T scores ranged between -0.95 and -1.42 for QUS. QUS parameters have adequate ability to discriminate osteoporotic patients from controls. The World Health Organization (WHO) threshold for diagnosis of osteoporosis does not apply to this technology. The clinical utility of BUB at the os calcis, in addition to usual ultrasound parameters, is not yet proven. However, BUB evaluation, which does not require two transducers and may be implemented in conventional reflection mode systems, warrants further studies.

Aging↗

Quantitative ultrasound imaging of the calcaneus: precision and variations during a 120-Day bed rest.

This study reports on the precision and variation of quantitative ultrasound (US) parameters [broadband ultrasonic attenuation (BUA) or slope of the frequency-dependent attenuation in dB/MHz and speed of sound (SOS m/second)] after 120 days of continuous bed rest in six normal male volunteers. Quantitative US was measured at the calcaneus using a new US bone imaging scanner. The measurements were carried out on both heels at approximately 2-week intervals. The short-term precision was 0.31% for SOS and 2.8% for BUA. The long-term precision was 0.58% for SOS, 4.7% for BUA. A significant decrease of SOS values of -26 m/second (P < 0.0001) for the right heel and -17 m/second (P < 0.05) for the left heel was found at the group level. In terms of percentage change this represents -1.7% for the right heel and -1.1% for the left heel. These percentage decrements were 3.5-5.5 times that of the short-term precision and 2-3 times that of the long-term precision of the technique. At the individual level, the decrease of SOS was statistically significant (P < 0.05) or marginally significant (P < 0.1) for four out of 6 subjects. For 2 other subjects, similar trends were observed, but without reaching statistical significance. BUA did not change significantly during follow-up. These results are consistent with previous findings on changes of ultrasonic properties from the calcaneus during aging, pregnancy, or therapy, showing that calcaneus SOS is a valuable index of bone loss. These preliminary data suggest that prolonged exposure to simulated weightlessness may lead to a lower SOS, which then could be used for the follow-up of bone demineralization occurring during long-term space flights.

Adult↗

Computerized ultrasound B-scan characterization of breast nodules.

The ability of computerized parameters to discriminate benign from malignant breast nodules from digitized ultrasonic acquisitions has been assessed. The images of 75 lesions, including 19 lesions proved to be malignant at histology and 56 found to be benign, were digitized and characterized by morphometric and texture parameters. The texture parameters, derived from first-order statistics, run-length matrices and co-occurrence matrices, were computed in the entire lesion and in a ring-shape region surrounding the contour of the lesion. The strongest features were found to be issued from the second region. Further investigations confirmed that the discriminant information was contained in the external part of the lesion and, to a lesser extent, in the neighboring tissue. A linear discriminant analysis using three features yielded a sensitivity of 94.7% for a specificity of 80.4% and the "leave-one-out" technique confirmed the results. Comparison with the classifications given by radiologists let us assume that information revealed by texture features is able to help the physician in reducing the number of unnecessary biopsies.

Breast Diseases↗

In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz.

Our goal was to evaluate the frequency dependence of the ultrasonic attenuation coefficient in cancellous bone. Estimates were obtained in immersion, using a substitution method in the through-transmit mode, by scanning 14 human bone specimens (calcaneus). Measurements were performed with three pairs of focused transducers with a center frequency of 0.5, 1.0, and 2.25 MHz, respectively in order to cover an extended frequency bandwidth (0.2-1.7 MHz). When the experimental attenuation coefficient values were modeled with a nonlinear power fit alpha(f)=alpha0 +alpha(I)f(n), the attenuation coefficient was found to increase as f(1.09+/-0.3) over the measurement bandwidth. However, a substantial variation of the exponent n (0.4-2.2) within specimens and also between specimens was observed. The acoustical parameters were compared to bone mineral density. A highly significant relationship was noted between alpha1 and BMD (r2= 0.75, p< 10(-4)). No correlation was found between n and BMD. Several attenuation mechanisms are discussed as well as the potential impact these results may have in in vivo quantitative measurements.

Acoustics↗

Phase and group velocities of fast and slow compressional waves in trabecular bone.

This Letter is an extension to a multilayer model of porous bone first proposed by Hughes et al. [Ultrasound Med. Biol. 25, 811-821 (1999)]. Both slow and fast compressional waves propagate when the acoustic wave propagation is parallel to the trabecular alignment. However, a slow wave disappears at high refraction angles. To explain this phenomenon, the multilayer model is extended to compute group velocity surface and arrival times with an angle. Two major effects are highlighted as the refraction angle increases. First, the energy of the slow wave is refracted from the phase propagation direction. Second, the signals of fast and slow waves overlap. As a consequence, the slow wave may not be observed for a refraction angle greater than 40 degrees, which is in agreement with previous experimental data published by Hughes et al. and others.

Acoustics↗

Analysis of the axial transmission technique for the assessment of skeletal status.

Ultrasonic wave propagation in human cortical bone has been investigated in vitro using the so-called axial transmission technique. This technique, which relies on velocity measurement of the first arriving signal, has been used in earlier investigations to study bone status during fracture healing or osteoporosis. Two quasi-point-source elements, one transmitter and one receiver (central frequency 0.5 MHz), were used to generate a wide ultrasonic beam, part of which strikes the sample surface at the longitudinal critical angle, and to receive the signals reflected from the sample surface. The analysis of the field reflected from a fluid-solid interface for an incident spherical wave predicts the existence of a lateral wave propagating along the sample surface at a velocity close to the longitudinal velocity, in addition to the ordinary reflected wave and vibration modes. The transducer-sample and the transmitter-receiver distances were chosen such that the lateral wave is the first arriving signal. Validation of the measuring technique was performed on test materials and was followed by experiments on human cortical bones. Experimental results (arrival time and velocity) strongly suggest that the first detected signal corresponds to the lateral wave predicted by theory.

Bone Density↗

Frequency dependence of ultrasonic backscattering in cancellous bone: autocorrelation model and experimental results.

The goal of this study is to model the frequency dependence of the ultrasonic backscatter coefficient in cancellous bone. A twofold theoretical approach has been adopted: the analytical theoretical model of Faran for spherical and cylindrical elastic scatterers, and the scattering model for weakly scattering medium in which the backscatter coefficient is related to the autocorrelation function of the propagating medium. The ultrasonic backscatter coefficient was measured in 19 bone specimens (human calcaneae) in the frequency range of 0.4-1.2 MHz. The autocorrelation function was computed from the three-dimensional (3D) microarchitecture measured using synchrotron radiation microtomography. Good agreement was found between the frequency dependence of the experimental (f3.38+/-0.31) and autocorrelation modeled (f3.48+/-0.26) backscatter coefficients. The results based on Faran theory (cylindrical Faran model: f2.89+/-0.06 and spherical Faran model: f3.91+/-0.04) show qualitative agreement with experimental data. The good prediction obtained by modeling the backscatter coefficient using the autocorrelation function of the medium opens interesting prospects for the investigation of the influence of bone microarchitecture on ultrasonic scattering.

Aged↗

Evaluation of error bounds on calcaneal speed of sound caused by surrounding soft tissue.

For absorptiometry measurements, soft tissue may have an impact on quantitative ultrasound (QUS) measurements. In the present study, we focused primarily on the quantification of measurement error on speed of sound (SOS) caused by surrounding soft tissue. The relevant soft tissue parameters affecting the inherent SOS inaccuracies are thickness and sound velocity. To meet our goal, SOS measurements were taken at the right heel using a QUS imaging device in 21 healthy subjects. Site-matched measurements of soft tissue thickness (STT) and bone width were performed using magnetic resonance imaging of the heel. Several bone velocities were calculated either by accounting for bone width (SOSBW) only or by taking into account the exact path lengths of all major components traversed by ultrasound &lapr;V(b)). Given that soft tissue composition is difficult to determine in vivo, we chose to estimate lower and upper error bounds on bone velocity (V(b lower) and V(b upper)) by spanning the full range of available values in the literature. The mean BW was 30.7 +/- 2.7 mm and the mean medial and external STTs were 8.8 +/- 1.7 and 8.5 +/- 1.5 mm, respectively. Accounting for true BW only resulted in no significant difference between SOS (1533 +/- 37) and SOSBW (1531 +/- 33). By contrast, accounting for both true BW and surrounding soft tissue resulted in an increase in the calculated bone velocity and statistically significant differences between SOS and V(b upper) (1568 +/- 36) and V(b lower) (1542 +/- 34). Root mean square errors between SOS and the calculated velocities were 0.34, 2. 32, and 0.70% for SOSBW, V(b upper), and V(b lower), respectively. We report here measurement errors caused by soft tissue to be 3 to 20 times higher than the SOS short-term precision (SOS coefficient of variation of 0.1%). Our results suggest that inaccuracies in SOS measurement caused by overlying soft tissue cannot be neglected. Overlying soft tissues may influence outcomes of longitudinal studies, especially if variations in tissue thickness and composition occur during the longitudinal follow-up. A practical way of minimizing the measurement error could be to perform an adequate correction for the overlying soft tissue. However, ideally, this should require knowing both the thickness and sound velocity in soft tissue. One might preferably conduct experimental investigations that directly control soft tissue thickness and composition to resolve this problem.

Adult↗

Ultrasound measurement on the calcaneus: influence of immersion time and rotation of the foot.

The aim of this study was to evaluate the influence of immersion time and rotation of the heel around the leg axis on the reproducibility of measurements using an ultrasound bone imaging scanner (UBIS) with a temperature-controlled water bath. Measurements were obtained in 10 men, 11 premenopausal women and 10 postmenopausal women. The right foot of all subjects was scanned 12 times with an interval of 3 min between each scan. The first 10 measurements, performed to study the effect of immersion time, were taken without intermediate repositioning. Measurements 11 and 12 were also taken without removing the foot, but the calcaneus position was varied by an angle of +/-2.5 degrees with respect to the reference position used during the first 10 measurements. Prolonged immersion of the heel led to a decrease in the variations of quantitative ultrasound (QUS) parameters between successive measurements. Following rapid variations with immersion time, the QUS parameters reached a plateau. The effect of immersion time on measurement error remained significant until the first two or three scans for broadband ultrasound attenuation (BUA) and until the sixth or seventh scans for speed of sound (SOS). The variation in BUA was more pronounced (p<0.05) for the group of postmenopausal women (20. 7% change in BUA between the first and tenth scans; p<0.005) than for the group of premenopausal women (6.8% change in BUA between the first and tenth scans; p<0.005). The variations in SOS were similar in the two groups (0.8% variation; p<0.005). The impact of immersion time was smaller for men than for women [2.5%, (p<0.01) and 0.4% (p<0.005) of the change between the first and tenth scans for BUA and SOS respectively]. On the whole, the measurement errors due to rotation of the heel were lower than those caused by immersion time. The variations were significant only in men and premenopausal women. Both immersion time and rotation of the heel may play a role in the precision of QUS and should be carefully standardized, particularly for longitudinal studies. In addition, following these results we have adopted a standardized protocol to derive the technique reproducibility in groups of premenopausal and postmenopausal women. The coefficients of variation were 1.1% for BUA and 0.1% for SOS in premenopausal women, and 1.4% for BUA and 0.13% for SOS in postmenopausal women.

Adult↗

[Evaluation of post-menopausal osteoporosis using ultrasound].

Quantitative ultrasound (QUS) has recently been proposed for evaluating bone mineral density. Several QUS units are now commercially available. They measure both the attenuation and velocity of the US beam, in a transmission mode, mainly at the calcaneum and phalanges. These parameters are mainly related to bone density, but may also, in theory, be affected by non-quantitative properties of bone such as elasticity and anisotropy. Values measured at QUS are lowered in osteoporotic patients compared to normal control subjects. The predictive value for hip fracture in an elderly population is similar for QUS measurements and conventional techniques of bone mineral density measurements. The reproducibility of measurements with QUS is good, but the variation to be measured is only minimal. Thus, QUS cannot yet be recommended for follow up of patients or evaluation of response to treatment. Technical advances are to be expected. Because this technique is non-invasive and simple, it represents a promising tool for the screening of patients at risk for osteoporosis.

Aged↗

[Evaluation of osteoporosis with ultrasound].

FUNDAMENTAL PRINCIPLE: Ultrasound exploration is a new noninvasive technique for evaluating bone strength. In theory, ultrasound parameters vary with bone density, elasticity and microstructure. In clinical practice, bone density is the essential parameter. THEORETICAL BASIS: Several devices are now available for measuring the density of subcutaneous bones. The beam attenuation and velocity from the calcaneum are routinely recorded. DIAGNOSTIC VALUE: Bone density of the calcaneum has good diagnostic value for osteoporosis. Mean values in subjects with fractures are lower than in age-matched controls. Several prospective studies have demonstrated the predictive value showing a significant rise in the risk of femoral neck fractures in subjects with decreased sonographic measurements of the calcaneum. FOR FOLLOW UP: Currently, reproductibility is insufficient for individual follow-up. Ongoing technical advances, with the possibility of ultrasound imaging of the bones, will be useful for follow-up management.

Bone Density↗

[Bone remodeling: evaluation methods].

Bone tissue undergoes continual renewal in order to keep the mechanical competence of the bone matrix. This is performed by two cells: osteoclasts which resorb the calcified matrix and osteoblast which synthetize a new bone matrix. Biochemical markers of bone remodelling allow the evaluation of the activity of each type of bone cells. An unbalance in this process induces modifications of the amount of calcified tissue and of the bone microarchitecture. Several technics based on X-ray and ultrasound allow a non invasive evaluation of these modifications.

Biomarkers↗