Effects of gamma irradiation on mechanical properties of defatted trabecular bone allografts assessed by speed-of-sound measurement.

New sterilization methods for human bone allografts may lead to alterations in bone mechanical properties, which strongly influence short- and medium-term outcomes. In many sterilization procedures, bone allografts are subjected to gamma irradiation, usually with 25 KGy, after treatment and packaging. We used speed-of-sound (SOS) measurements to evaluate the effects of gamma irradiation on bone. All bone specimens were subjected to the same microbial inactivation procedure. They were then separated into three groups, of which one was treated and not irradiated and two were exposed to 10 and 25 KGy of gamma radiation, respectively. SOS was measured using high- and low-frequency ultrasound beams in each orthogonal direction. SOS and Young modulus were altered significantly in the three groups, compared to native untreated bone. Exposure to 10 or 25 KGy had no noticeable effect on the study variables. The impact of irradiation was small compared to the effects of physical or chemical defatting. Reducing the radiation dose used in everyday practice failed to improve graft mechanical properties in this study.

Acoustics↗

Apparent Young's modulus of human radius using inverse finite-element method.

The ability to assess the elastic and failure properties of cortical bone at the radial diaphysis has a clinical importance. A new generation of quantitative ultrasound (QUS) devices and peripheral quantitative computed tomography (p-QCT) has been developed to assess non-invasively bone material and structural properties at the distal radius. This anatomical site is characterized by a thin cortical thickness that complicates traditional mechanical testing methods on specimens. Until now, mechanical properties of cortical bone at distal radius (e.g., elastic modulus, yield stress and strain) remain rarely studied probably due to experimental difficulties. The present study introduces an inverse finite-element method strategy to measure the elastic modulus and yield properties of human cortical specimens of the radial diaphysis. Twenty millimeter-thick portions of diaphysis were cut from 40 human radii (ages 45-90) for biomechanical test. Subsequently the same portion was modeled in order to obtain a specimen-specific three dimensional finite-element model (3D-FEM). Longitudinal elastic constants at the apparent level and stress characterizations were performed by coupling mechanical parameters with isotropic linear-elastic simulations. The results indicated that the mean apparent Young's modulus for radial cortical bone was 16 GPa (SD 1.8) and the yield stress was 153 MPa (SD 33). Breaking load was 12,946 N (SD 3644), cortical thickness 2.9 mm (SD 0.6), structural effective strain at the yield (epsilon(y)=0.0097) and failure (epsilon(u)=0.0154) load were also calculated. The 3D-FEM strategy described here may help to investigate bone mechanical properties when some difficulties arise from machining mechanical sample.

Aged↗

A method for the estimation of femoral bone mineral density from variables of ultrasound transmission through the human femur.

Quantitative ultrasound (QUS) measurements at peripheral sites can be used to estimate osteoporotic fracture risk. However, measurements at these sites are less suitable to predict bone mineral density (BMD) or fracture risk at the central skeleton. We investigated whether direct QUS measurements at the femur would allow to estimate dual X-ray absorptiometry (DXA) BMD of the total proximal femur with errors comparable to established DXA accuracy errors. Two independent sets of femora were measured in Kiel (6 f, 4 m, age: 55-90) and Paris (19 f, 20 m age: 45-95) using different benchtop systems in the two laboratories. The femora were scanned in transverse transmission mode using focused US transducers of 500 kHz center frequency. The QUS values were averaged over a region similar to the total hip region of dual X-ray absorptiometry (DXA) measurements. BMD was measured using DXA. SOS and BMD correlated significantly (p<0.0001) in both data sets (R2=0.81-0.93). Correlations between BUA and BMD were also significant at p<0.001, but correlation coefficients were lower (R2=0.61-0.75). Residual errors for the estimation of BMD were 8%-10% for SOS as predictor, and 14%-16% for BUA as predictor. The residual error of 8 to 10% for the estimation of BMD from SOS is comparable to variabilities among different DXA femur subregions and accuracy errors of femoral DXA measurements caused by the impact of soft tissue. It is substantially smaller than the errors of 13% for the estimation of total femur BMD from spine BMD, 14% for the estimation of total femur BMD from calcaneus SOS or 16% for the estimation of ash weight from DXA. The results of the study show that SOS is able to predict total BMD with adequate accuracy. If femoral BMD could be obtained in vivo with comparable accuracy, femoral QUS would be suited for the assessment of bone status at one of the main osteoporotic fracture sites.

Absorptiometry, Photon↗

Influence of the precision of spectral backscatter measurements on the estimation of scatterers size in cancellous bone.

The goal of this study is to propose a model for the ultrasonic frequency-dependent backscatter coefficient in femoral cancellous bone. This model has been developed with success to predict backscatter in human calcaneal bone [Jenson, Ultr. Med. Biol. 2003]. A weak scattering model is used and the backscatter coefficient is expressed in terms of a Gaussian autocorrelation function of the medium. The backscatter coefficient is computed and comparison is made with experimental data for 37 specimens and for frequency ranging from 0.4 to 1.2 MHz. An excellent agreement between experimental data and predictions is found for both the magnitude and the frequency-dependence of the backscatter coefficient. Then, a nonlinear regression is performed for each specimen, and the mean trabecular thickness is estimated. Experimental data and theoretical predictions are averaged over the 37 specimens. We also find a close agreement between theoretical predictions obtained using the Gaussian autocorrelation function (scatterer size=134+/-15 microm) and the mean trabecular thickness (Tb.Th=132+/-12 microm) derived from the analysis of bone 3-D micro-architecture using high-resolution micro-tomography. However, the correlation between individual experimental and estimated Tb.Th values is moderate (R(2)=0.44). The performance of the estimator are limited mainly by two factors: interference noise due to random positioning of the scatterers and attenuation. We show that the fundamental limitation of our estimator due to the speckle noise is around 5 microm for trabecular thickness estimation. This limitation is lower than the observed biological variability which is around 30 microm and should not be a limiting factor for individual prediction. A second limitation is the tremendous attenuation encountered in highly scattering media such as cancellous bone, which results in highly damped backscatter signals. The compensation for attenuation is difficult to perform, and it may be a critical point that limits the precision of the estimator.

Algorithms↗

Numerical simulation of the dependence of quantitative ultrasonic parameters on trabecular bone microarchitecture and elastic constants.

Finite-difference numerical simulation of ultrasound propagation in complex media such as cancellous bone represents a fertile alternative to analytical approaches because it can manage the complex 3D bone structure by coupling the numerical computation with 3D numerical models of bone microarchitecture obtained from high-resolution imaging modalities. The objective of this work was to assess in silico the sensitivity of ultrasound parameters to controlled changes of microarchitecture and variation of elastic constants. The simulation software uses a finite-difference approach based on the Virieux numerical scheme. An incident plane wave was propagated through a volume of bone of approximately 5 x 5 x 8 mm(3). The volumes were reconstructed from high-resolution micro-computed tomography data. An iterative numerical scenario of "virtual osteoporosis" was implemented using a dedicated image processing algorithm in order to modify the initial 3D microstructures. Numerical computations of wave propagation were performed at each step of the process. The sensitivity to bone material properties was also tested by changing the elastic constants of bone tissue. Our results suggest that ultrasonic variables (slope of the frequency-dependent attenuation coefficient and speed of sound) are mostly influenced by bone volume fraction. However, material properties and structure also appear to play a role. The impact of modifications of the stiffness coefficients remained lower than the variability caused by structural variations. This study emphasizes the potential of numerical computations tools coupled to realistic 3D structures to elucidate the physical mechanisms of interaction between ultrasound and bone structure and to assess the sensitivity of ultrasound variables to different bone properties.

Algorithms↗

Numerical simulation of wave propagation in cancellous bone.

Numerical simulation of wave propagation is performed through 31 3D volumes of trabecular bone. These volumes were reconstructed from high synchrotron microtomography experiments and are used as the input geometry in a simulation software developed in our laboratory. The simulation algorithm accounts for propagation into both the saturating fluid and bone but absorption is not taken into account. We show that 3D simulation predicts phenomena observed experimentally in trabecular bones : linear frequency dependence of attenuation, increase of attenuation and speed of sound with the bone volume fraction, negative phase velocity dispersion in most of the specimens, propagation of fast and slow wave depending on the orientation of the trabecular network compared to the direction of propagation of the ultrasound. Moreover, the predicted attenuation is in very close agreement with the experimental one measured on the same specimens. Coupling numerical simulation with real bone architecture therefore provides a powerful tool to investigate the physics of ultrasound propagation in trabecular structures.

Algorithms↗

Bone micro-damage assessment using non-linear resonant ultrasound spectroscopy (NRUS) techniques: a feasibility study.

Non-linear resonant ultrasound spectroscopy (NRUS) is a technique exploiting the significant non-linear behavior of damaged materials, related to the presence of damage. This study shows for the first time the feasibility of this technique for damage assessment in bone. Two samples of bovine cortical bone were subjected to a progressive damage experiment. Damage accumulation was progressively induced in the samples by mechanical testing. For independent assessment of damage, X-ray CT imaging was performed at each damage step, but only helped in the detection of the prominent cracks. Synchrotron micro-CT imaging and histology using epifluorescence microscopy were performed in one of the two samples at the last damage step and allowed detection of micro-cracks for this step. As the quantity of damage accumulation increased, NRUS revealed a corresponding increase in the non-linear response. The measured change in non-linear response is much more sensitive than the change in elastic modulus. The results suggest that NRUS could be a potential tool for micro-damage assessment in bone. Further work has to be carried out for a better understanding of the physical nature of damaged bone, and for the ultimate goal of in vivo implementation of the technique where bone access will be a challenging problem.

Algorithms↗

Site-matched assessment of structural and tissue properties of cortical bone using scanning acoustic microscopy and synchrotron radiation muCT.

200 MHz scanning acoustic microscopy (SAM) and synchrotron radiation muCT (SR-muCT) were used to assess microstructural parameters and tissue properties in site-matched regions of interest in cortical bone. Anterior and postero-lateral regions of ten cross sections from human cortical radius were explored. Structural parameters, including diameter and number of Haversian canals per cortical area (Ca.Dm, N.Ca/Ar) and porosity Po were assessed with both methods using a custom-developed image fusion and analysis software. Acoustic impedance Z and degree of mineralization of bone DMB were extracted separately for osteonal and interstitial tissues from the fused images. Structural parameter estimations obtained from radiographic and acoustic images were almost identical. DMB and impedance values were in the range between 0.77 and 1.28 g cm(-3) and 5.13 and 12.1 Mrayl, respectively. Interindividual and regional variations were observed, whereas the strongest difference was found between osteonal and interstitial tissues (Z: 7.2 +/- 1.1 Mrayl versus 9.3 +/- 1.0 Mrayl, DMB: 1.06 +/- 0.07 g cm(-3) versus 1.16 +/- 0.05 g cm(-3), paired t-test, p < 0.05). Weak, but significant correlations between DMB and Z were obtained for the osteonal (R(2) = 0.174, p < 10(-4)) and for the pooled (osteonal and interstitial) data. The regression of the pooled osteonal and interstitial tissue data follows a second-order polynomial (R(2) = 0.39, p < 10(-4)). Both modalities fulfil the requirement for a simultaneous evaluation of cortical bone microstructure and material properties at the tissue level. While SAM inspection is limited to the evaluation of carefully prepared sample surfaces, SR-muCT provides volumetric information on the tissue without substantial preparation requirements. However, SAM provides a quantitative estimate of elastic properties at the tissue level that cannot be captured by SR-muCT.

Aged↗

In vitro ultrasonic characterization of human cancellous femoral bone using transmission and backscatter measurements: relationships to bone mineral density.

Thirty-eight slices of pure trabecular bone 1-cm thickness were extracted from human proximal femurs. A pair of 1-MHz central frequency transducers was used to measure quantitative ultrasound (QUS) parameters in transmission [normalized broadband ultrasound attenuation (nBUA), speed of sound (SOS)] and in backscatter [broadband ultrasound backscatter (BUB)]. Bone mineral density (BMD) was measured using clinical x-ray quantitative computed tomography. Site-matched identical region of interest (ROIs) of 7 x 7 mm2 were positioned on QUS and QCT images. This procedure resulted in 605 ROIs for all the specimens data pooled together. The short-term precision of the technique expressed in terms of CV was found to be 2.3% for nBUA, 0.3% for SOS and 4.5% for BUB. Significant linear correlation between QUS and BMD were found for all the 605 ROIs pooled, with r2 values of 0.73, 0.77, and 0.58 for nBUA, SOS, and BUB, respectively (all p < 0.05). For the BUB, the best regression was obtained with a polynomial fit of second order (r2 = 0.63). An analysis of measurements errors was developed. It showed that the residual variability of SOS is almost completely predicted by measurements errors, which is not the case for BUA and BUB, suggesting a role for micro-architecture in the determination of BUA and BUB.

Aged↗

Optimal prediction of bone mineral density with ultrasonic measurements in excised human femur.

Bone mineral density (BMD) measured with dual energy X-ray absorptiometry (DXA) techniques is the current gold standard for osteoporotic fracture risk prediction. Quantitative ultrasound (QUS) techniques in transmission measurements are, however, increasingly recognized as an alternative approach. It is feasible to select different QUS methods, one type being optimized to assess microarchitectural properties of bone structure and another to assess BMD. Broadband ultrasonic attenuation (BUA) and ultrasonic velocity (UV) measured on the proximal human femur have been shown to be both significantly correlated with BMD. However, a great diversity of algorithms has been reported to measure the time-of-flight used to derive UV values. The purpose of this study was to determine which procedure results in the optimal BMD prediction at the proximal femur from ultrasound measurements. Thirty-eight excised human femurs were measured in transmission with a pair of focused 0.5-MHz central frequency transducers. Two-dimensional scans were performed and radiofrequency (RF) signals were recorded digitally at each scan position. BUA was estimated and eight different signal processing techniques were performed to estimate UV. For each signal-processing technique UV was compared to BMD. We show that the best prediction of BMD was obtained with signal-processing techniques taking into account only the first part of the transmitted signal (r2BMD-SOS = 0.86). Moreover, we show that a linear multiple regression using both BUA and speed of sound (SOS) and applied to site-matched regions of interest improved the accuracy of BMD predictions (r2BMD-SOS/BUA = 0.95). Our results demonstrate that selecting specific signal-processing methods for QUS variables allows optimal assessment of BMD. Correlation is sufficiently high that this specific QUS method can be considered as a good surrogate of BMD.

Absorptiometry, Photon↗

High-resolution ultrasonography of subretinal structure and assessment of retina degeneration in rat.

The purpose of this work was to evaluate the ability of 80 MHz ultrasonography to differentiate intra-retinal layers and quantitatively assess photoreceptor dystrophy in small animal models. Four groups of 10 RCS rats each (five dystrophic and five controls) were explored at 25, 35, 45 and 55 days post-natal (PN). A series of retina cross-sections were obtained ex vivo from outside intact eyes using an 80 MHz three-dimensional ultrasound backscatter microscope (20-microm-axial resolution). Ultrasound features of normal retina were correlated to those of corresponding histology and thickness measurements of photoreceptor segment and nuclear layers were performed on all groups. To show the ability of 80 MHz ultrasonography to distinguish the retinal degeneration in vivo, one RCS rat was explored at 25 and 55 days post-natal. Ultrasound image of normal retina displayed four distinct layers marked by reflections at neurites/nuclei interfaces and permitted to differentiate the photoreceptor segment and nuclear layers. The backscatter level from the retina was shown to be related to the size, density and organization of the intra-layer structure. Ultrasound thickness measurements highly correlated with histologic measurements. A thinning (p<0.05) of outer nuclear layer (ONL) was detected over time for controls and was thought to be assigned to retina maturation. Retinal degeneration started at PN35 and resulted in a more pronounced ONL thinning (p<0.05) over time. ONL degeneration was accompanied by segment layer thickening (p<0.05) at PN35 and thinning thereafter. These changes may indicate accumulation of outer segment debris at PN35 then progressive destruction. In vivo images of rat intra-retinal structure showed the ability of the method to distinguish the photoreceptor layer changes. Our results indicate that 80 MHz ultrasonography reveals intra-retinal layers and is sensitive to age and degenerative changes of photoreceptors. This technique has great potential to follow-up retinal dystrophy and therapeutic effects in vivo.

Animals↗

In vitro chronic hepatic disease characterization with a multiparametric ultrasonic approach.

Although, high resolution, real-time ultrasonic (US) imaging is routinely available, image interpretation is based on grey-level and texture and quantitative evaluation is limited. Other potentially useful diagnostic information from US echoes may include modifications in tissue acoustic parameters (speed, attenuation and backscattering) resulting from disease development. Changes in acoustical parameters can be detected using time-of-flight and spectral analysis techniques. The objective of this study is to explore the potential of three parameters together (attenuation coefficient, US speed and integrated backscatter coefficient-IBC) to discriminate healthy and fibrosis subgroups in liver tissue. Echoes from 21 fresh in vitro samples of human liver and from a plane reflector were obtained using a 20-MHz central frequency transducer (6-30 MHz bandpass). The scan plane was parallel to the reflector placed beneath the liver. A 30 x 20 matrix of A-scans was obtained, with a 200-microm step. The samples were classified according to the Metavir scale in five different degrees of fibrosis. US speed, attenuation and IBC were estimated from standard methods described in the literature. Statistical tests were applied to the results of each parameter individually and indicated that it was not possible to identify all the fibrosis groups. Then a discriminant analysis was performed for the three parameters together resulting in a reasonable separation of fibrotic groups. Although the number of tissue samples is limited, this study opens the possibility of enhancing the discriminant capability of ultrasonic parameters of liver tissue disease when they are combined together.

Acoustics↗

Comparison of three ultrasonic axial transmission methods for bone assessment.

This study compared three approaches to bone assessment using ultrasonic axial transmission. In 41 fresh human radii, velocity of the first arriving signal was measured with a commercial device (Sunlight Omnisense) operating at 1.25 MHz, a prototype based on 1-MHz bidirectional axial transmission and a low-frequency (200 kHz) prototype, also measuring the velocity of a slower wave. Cortical and trabecular bone mineral density, cortical thickness and cross-sectional area were determined by peripheral quantitative computed tomography. Significant but modest correlation between velocities reflects differences in the nature of the propagating waves and methodological differences. Of the higher frequency devices, bidirectional measurements provided stronger correlations with bone properties than did conventional measurements. High-frequency devices were less sensitive to cortical thickness than was the low-frequency device, because higher frequency waves interrogate thinner cortical layers. The results suggest that different axial transmission approaches reflect different bone properties. Therefore, a multifrequency technique might be useful in probing different bone properties.

Aged↗

In vitro speed of sound measurement at intact human femur specimens.

Quantitative ultrasound has been recognized as a useful tool for fracture risk prediction. Current measurement techniques are limited to peripheral skeletal sites. Our objective was to demonstrate the in vitro feasibility of ultrasonic velocity measurements on human proximal femur and to investigate the relationship between velocity and bone mineral density (BMD). Sound velocity images were computed from 2-D scans performed on 38 excised human femurs in transmission at 0.5 MHz. Different regions-of-interest were investigated. Dual x-ray absorptiometry scans have been achieved for BMD measurements in site-matched regions. Our study demonstrates the feasibility of ultrasonic velocity measurements at the hip with reasonable precision (coefficient of variation of 0.3%). The best prediction of BMD was reached in the intertrochanter region (r(2) = 0.91, p < 10(-4)), with a residual error of 0.06 g/cm(2) (10%). Because BMD measured at the femur is the best predictor of hip fracture risk, the highly significant correlation and small residual error found in this study suggest that speed of sound measurement at the femur might be a good candidate for hip fracture risk prediction.

Absorptiometry, Photon↗

Appropriateness of internal digital phantoms for monitoring the stability of the UBIS 5000 quantitative ultrasound device in clinical trials.

In bone status assessment, proper quality assurance/quality control is crucial since changes due to disease or therapeutic treatment are very small, in the order of 2-5%. Unlike for dual X-ray absorptiometry, quality control procedures have not been extensively developed and validated for quantitative ultrasound technology, limiting its use in longitudinal monitoring. While the challenge of developing an ideal anthropometric phantom is still open, some manufacturers use the concept of the internal digital phantom mimicking human characteristics to check the stability of their device. The objective of the study was to develop a sensitive model of quality control suitable for the correction of QUS patient data. In order to achieve this goal, we simulated a longitudinal device lifetime with both correct and malfunctioning behaviors. Then, we verified the efficiency of digital phantoms in detecting those changes and subsequently established the in vitro/in vivo relationship. This is the first time that an attempt to validate an internal digital phantom has made, and that this type of validation approach is used. The digital phantom (DP) was designed to mimic normal bone (BUAP2) and osteoporotic bone (BUAP1) properties. The DP was studied using the UBIS 5000 ultrasound device (DMS, France). Diverse malfunctions of the UBIS-5000 were simulated. Several series of measurements were performed on both BUAP1 and 2 and on 12 volunteers at each grade of malfunction. The effect of each simulated malfunction on in vivo and in vitro results was presented graphically by plotting the average BUA values against the percentage change from baseline. The change from baseline in BUA was modeled using linear regression, and the in vivo/in vitro ratio was obtained from the model. All experimentations influenced the measure of BUAP1 and 2 as well as the measure of our 12 volunteers. However, the degree of significance varied as a function of the severity of the malfunction, and the results also differed substantially in magnitude between in vivo and in vitro. Indeed, the DP was about 10 times more sensitive to variations of the transfer function than was the in vivo measurement, which is very reassuring. The sensitivity of the digital phantoms was reliable in the determination of simulated malfunctions of the UBIS-5000. The digital phantoms provided an accurate evaluation of the acoustic performance of the scanner, including the fidelity of transducers. In light of these results, the QC approach of the UBIS-5000 will be extremely simple to implement compared with other devices. Indeed, since the digital phantom was automatically measured during every patient measurement, the QC approach could be built on an individual level basis rather than on an average basis.

Adult↗

High resolution ultrasound elastomicroscopy imaging of soft tissues: system development and feasibility.

Research in elasticity imaging typically relies on 1-10 MHz ultrasound. Elasticity imaging at these frequencies can provide strain maps with a resolution in the order of millimetres, but this is not sufficient for applications to skin, articular cartilage or other fine structures. We developed a prototype high resolution elastomicroscopy system consisting of a 50 MHz ultrasound backscatter microscope system and a calibrated compression device using a load cell to measure the pressure applied to the specimen, which was installed between a rigidly fixed face-plate and a specimen platform. Radiofrequency data were acquired in a B-scan format (10 mm wide x 3 mm deep) in specimens of mouse skin and bovine patellar cartilage. The scanning resolution along the B-scan plane direction was 50 microm, and the ultrasound signals were digitized at 500 MHz to achieve a sensitivity better than 1 microm for the axial displacement measurement. Because of elevated attenuation of ultrasound at high frequencies, special consideration was necessary to design a face-plate permitting efficient ultrasound transmission into the specimen and relative uniformity of the compression. Best results were obtained using a thin plastic film to cover a specially shaped slit in the face-plate. Local tissue strain maps were constructed by applying a cross-correlation tracking method to signals obtained at the same site at different compression levels. The speed of sound in the tissue specimen (1589.8+/-7.8 m s(-1) for cartilage and 1532.4+/-4.4 m s(-1) for skin) was simultaneously measured during the compression test. Preliminary results demonstrated that this ultrasound elastomicroscopy technique was able to map deformations of the skin and articular cartilage specimens to high resolution, in the order of 50 microm. This system can also be potentially used for the assessment of other biological tissues, bioengineered tissues or biomaterials with fine structures.

Animals↗

In vitro ultrasound measurement at the human femur.

Measurements of broadband ultrasonic attenuation (BUA) represent an established means of skeletal status assessment in osteoporosis. Today, the skeletal site that is the most widely used clinically is the calcaneus (heel bone). However, we hypothesized that fracture risk predictions could be improved if ultrasound measurements were performed directly at the main site of fracture, e.g., the proximal femur. The goal of this paper is to demonstrate in vitro the feasibility of quantitative ultra sound (QUS) imaging at the upper part of fee femur, and to investigate the relationships of BUA to bone mineral density (BMD). Forty-four excise human femurs were measured in transmission with a pair of focused 0.5-MHz central frequency transducers. Two-dimensional scans were performed, and the radio frequency (rf) signals were recorded at each measurement point. A data acceptance criterion for region of interest (ROI) selection was established based on the linearity of the frequency-dependent attenuation. Five measurements with repositioning were performed on each sample to determine the reproducibility. Dual energy x-ray absorptiometry (DXA) scans have been performed on the samples for BMD measurements: Three ROIs were selected in the specimens: greater, trochanter intertrochanteric, and femoral neck regions. Coefficient of variations were in the range 1.6% to 2.5%. The determination coefficients (r(2)) between BUA and BMD in site-matched ROIs were 0.81, 0.78, and 0.73, respectively, for the greater trochanteric, intertrochanteric, and femoral neck regions. Our results are consistent with data previously shown at the calcaneus and demonstrate the feasibility of QUS measurements at the femur in vitro, with reasonable reproducibility.

Absorptiometry, Photon↗

2D arrays device for calcaneus bone transmission: an alternative technological solution using crossed beam forming.

In the context of manned space flight with the European Space Agency, a quantitative ultrasound device for transmission imaging through the calcaneus bone has been developed. It includes two matrix transducers of 576 elements each in order to electronically perform the scanning and the focusing of the 500 kHz ultrasonic beam. This device called the BEAM scanner, provides two parametric images of attenuation (BUA, broadband ultrasonic attenuation) and velocity (SOS, speed of sound) of the investigated skeletal site. The cost and complexity of such a device has motivated the study of an alternative solution, less demanding in terms of technology, based on a crossed beam former [H. Ermert et al., A new concept for a real-time ultrasound transmission camera, in: IEEE Ultrasonics Symposium Proceedings, 2000, pp. 1611-1614]. It consists in forming two perpendicular cylindrically focused planes, one in emission, one in reception, instead of two spherically focused apertures. The crossing line of the two planes replaces the focused beam. The 2D beam forming technological challenge is moved to a 1D simpler and cheaper architecture. In this work the two solutions have been compared for in vivo measurements. Data sets have been acquired using all spatial combinations of emission and reception single elements of the matrix. Then signals have been processed using either the cylindrical or the spherical focussing mode. For cylindrical focussing, the increased level of the side lobes caused severe artefacts. Several apodization techniques have been implemented to reduce these artefacts, resulting in encouraging results. After a brief description of this new ultrasonic method for bone quantitative assessment, several reconstructed images using both processing schemes are presented. Corresponding statistical results obtained in 29 subjects are also provided.

Algorithms↗