Water absorption kinetics in different wettability conditions studied at pore and sample scales in porous media by NMR with portable single-sided and laboratory imaging devices.

NMR relaxation time distributions of water (1)H obtained by a portable single-sided surface device have been compared with MRI internal images obtained with a laboratory imaging apparatus on the same biocalcarenite (Lecce Stone) samples during capillary water uptake. The aim of this work was to check the ability of NMR methods to quantitatively follow the absorption phenomenon under different wettability conditions of the internal pore surfaces. Stone wettability changes were obtained by capillary absorption of a chloroform solution of Paraloid PB72, a hydrophobic acrylic resin frequently used to protect monuments and buildings, through one face of each sample. Both relaxation and imaging data have been found in good quantitative agreement each other and with masses of water determined by weighing the samples. In particular the Washburn model of water capillary rise applied to the imaging data allowed us to quantify the sorptivity in both treated and untreated samples. Combining relaxation and imaging data, a synergetic improvement of our understanding of the water absorption kinetics at both pore and sample scales is obtained. Since relaxation data have been taken over the course of time without interrupting the absorption process, simply by keeping the portable device on the surface opposite to the absorption, the results show that the single-sided NMR technique is a powerful tool for in situ evaluation of water-repellent treatments frequently used for consolidation and/or protection of stone artifacts.

Journal Article↗

Analysis of 1H-NMR relaxation time distributions in L1 to L6 rat lumbar vertebrae.

A better knowledge of the NMR relaxation behavior of bone tissue can improve the definition of imaging protocols to detect bone diseases like osteoporosis. The six rat lumbar vertebrae, from L1 to L6, were analyzed by means of both transverse (T(2)) and longitudinal (T(1)) relaxation of (1)H nuclei at 20 MHz and 30 degrees C. Distributions of relaxation times, computed using the multiexponential inversion software uniform penalty inversion, extend over decades for both T(2) and T(1) relaxation. In all samples, the free induction decay (FID) from an inversion-recovery (IR) T(1) measurement shows an approximately Gaussian (solid-like) component, exp[-1/2(t/T(GC))2], with T(GC) approximately 12 micros (GC for Gaussian component) and a liquid-like component (LLC) with initially simple-exponential decay. Averaging and smoothing procedures are adopted to obtain the ratio alpha between GC and LLC signals and to get separate T(1) distributions for GC and LLC. Distributions of T(1) for LLC show peaks centered at 300-500 ms and shoulders going down to 10 ms, whereas distributions of T(1) for GC are single broad peaks centered at roughly 100 ms. The T(2) distributions by Carr-Purcell-Meiboom-Gill at 600 micros echo spacing are very broad and extend from 1 ms to hundreds of ms. This long echo spacing does not allow one to see a peak in the region of hundreds of micros, which is better seen by single spin-echo T(2) measurements. Results of the relaxation analysis were then compared with densitometric data. From the study, a clear picture of the intratrabecular and intertrabecular (1)H signals emerges. In particular, the GC is presumed to be due to (1)H in collagen, LLC due to all the fluids in the bone including water and fat, and the very short T(2) peak due to the intratrabecular water. Overall, indications of some trends in composition and in pore-space distributions going from L1 to L6 appeared. Published results on rat vertebrae obtained by fitting the curves by discrete two-component models for both T(2) and T(1) are consistent with our results and can be better interpreted in light of the shown distributions of relaxation times.

Animals↗

Continuous distribution analysis of marrow 1H magnetic resonance relaxation in bone.

Longitudinal and transverse NMR relaxation of 1H nuclei were studied in vitro on fresh animal femur samples. A large number of data points were taken, starting at 100 micros for T(1) by inversion-recovery, at 200 micros for T(2) by single-echo sequences, and at 600 micros for T(2) by CPMG echo-trains. Quasi-continuous distributions of relaxation times were computed, giving wide distributions for all samples. Bulk marrow removed from the medullary cavity showed T(2) distributions from about 20 ms to 600 ms and T(1) distributions from about 40 ms to 2 s. The 1H nuclei in trabecular bone samples, where marrow is confined, may show long tails for T(2) at relaxation times down to 250 micros, the origin of which is still not known. These tails are absent in bulk marrow from the medullary cavity. The differences observed in T(1) distributions among trabecular bone samples are in accordance with the different marrow compositions. Discrete exponential fits were computed also, and in most cases four discrete exponential components were required to fit the experimental data adequately. However, the discrete components do not seem to correspond to any physically distinguishable separate compartments.

Algorithms↗

Uniform-penalty inversion of multiexponential decay data. II. Data spacing, T(2) data, systemic data errors, and diagnostics.

The basic method of UPEN (uniform penalty inversion of multiexponential decay data) is given in an earlier publication (Borgia et al., J. Magn. Reson. 132, 65-77 (1998)), which also discusses the effects of noise, constraints, and smoothing on the resolution or apparent resolution of features of a computed distribution of relaxation times. UPEN applies negative feedback to a regularization penalty, allowing stronger smoothing for a broad feature than for a sharp line. This avoids unnecessarily broadening the sharp line and/or breaking the wide peak or tail into several peaks that the relaxation data do not demand to be separate. The experimental and artificial data presented earlier were T(1) data, and all had fixed data spacings, uniform in log-time. However, for T(2) data, usually spaced uniformly in linear time, or for data spaced in any manner, we have found that the data spacing does not enter explicitly into the computation. The present work shows the extension of UPEN to T(2) data, including the averaging of data in windows and the use of the corresponding weighting factors in the computation. Measures are implemented to control portions of computed distributions extending beyond the data range. The input smoothing parameters in UPEN are normally fixed, rather than data dependent. A major problem arises, especially at high signal-to-noise ratios, when UPEN is applied to data sets with systematic errors due to instrumental nonidealities or adjustment problems. For instance, a relaxation curve for a wide line can be narrowed by an artificial downward bending of the relaxation curve. Diagnostic parameters are generated to help identify data problems, and the diagnostics are applied in several examples, with particular attention to the meaningful resolution of two closely spaced peaks in a distribution of relaxation times. Where feasible, processing with UPEN in nearly real time should help identify data problems while further instrument adjustments can still be made. The need for the nonnegative constraint is greatly reduced in UPEN, and preliminary processing without this constraint helps identify data sets for which application of the nonnegative constraint is too expensive in terms of error of fit for the data set to represent sums of decaying positive exponentials plus random noise.

Geologic Sediments↗

Uniform-penalty inversion of multiexponential decay data.

NMR relaxation data and those from many other physical measurements are sums of exponentially decaying components, combined with some unavoidable measurement noise. When decay data are inverted in order to give quasi-continuous distributions of relaxation times, some smoothing of the distributions is normally implemented to avoid excess variation. When the same distribution has a sharp peak and a much broader peak or a "tail," as for many porous media saturated with liquids, an inversion program using a fixed smoothing coefficient may broaden the sharp peak and/or break the wide peak or tail into several separate peaks, even if the coefficient is adaptively chosen in accord with the noise level of the data. We deal with this problem by using variable smoothing, determined by iterative feedback in such a way that the smoothing penalty is roughly constant. This uniform-penalty (UP) smoothing can give sharp lines, not broadened more than is consistent with the noise, and in the same distribution it can show a tail decades long without breaking it up into several peaks. The noise level must be known approximately, but it can be determined more than adequately by a preliminary inversion. The same iterative procedure is used to implement constraints such as non-negative (NN) or monotonic-from-peak (MT). The significance of an additional resolved peak may be tested by finding the cost of using MT to force a unimodal solution. A bimodal constraint can be applied. Decay data representing sharp lines in contact with broad features can require substantial computing time and some controls to stabilize the iterative sequence. However, UP can be made to function smoothly for a very wide variety of decay curves, which can be processed without adjustment of parameters, including the dimensionless smoothing parameters. Extensive testing has been done with artificial data. Examples are shown for artificial data, biological tissues, ceramic technology, and sandstones. Expressions are given relating noise level to line width and for significance of increase or decrease in error of fit.

Algorithms↗

The effect of diffusion and susceptibility differences on T2 measurements for fluids in porous media and biological tissues.

A number of features of T2 measurements for fluids in porous media have shown behavior contrary to that suggested by intuition developed in other areas. For porous media with relatively uniform pore spaces the following have been observed, in each case for certain ranges only of Xv (susceptibility difference times frequency), D (diffusion coefficient), a (a pore dimension), porespace shape and distribution, echo-time t for single echoes and half-echo-spacing tau for CPMG): (1) In S(t) for FID (free induction decay, S for signal) with constant slope after an initial period of increasing slope; (2) In Ss(t) for single (subscript s) echoes linear (instead of cubic) in t after an initial period; (3) for CPMG R(tau) = 1/T2(tau) - 1/T2(tau-->0) linear in tau over a substantial range; (4) slope of R(tau) independent of D and alpha for this range; (5) slope R(s) of In Ss(t) independent of D and a, and (6) R(s)(t) and R(tau) at long times linear (instead of quadratic) in Xv. These features appear to be compatible with the assumption of a truncated Cauchy-Lorentz distribution of the local magnetic fields due to susceptibility differences. The statistics of repeated sampling of local fields in different parts of the porespace during diffusion lead to a suppression, after a short time, of the effects of diffusion on the FID decay rate and the single-echo decay rate over significant ranges of the parameters. Data are presented to extend the range of parameters studied previously.

Dental Porcelain↗

Developments in core analysis by NMR measurements.

For a large suite of consolidated sandstone samples low in shale content we have measured the permeability k, irreducible water saturation Swi, porosity phi, electrical-resistivity formation factor F, porosity by NMR, geometric-mean relaxation times T1g, and stretched-exponential relaxation times T1s. We find that T1g (or T1s) is the decisive parameter for the estimation of k or Swi of porous sandstones by other than direct measurements of these quantities. The additional use of phi or F brings appreciable, but not decisive, improvement. We show isovalue maps of the error factor delta, which show substantial regions of near-minimum values of delta and show basic compatibility of our estimators for permeability with different published estimators. The exponents of T1g (or T1s) in our power-law estimators and those of various published estimators for k are not very far from 2.0 if either or both of phi and F are also used in the estimators.

Magnetic Resonance Spectroscopy↗

A robust method for calculating geometric mean times from multiexponential relaxation data, using only a few data points and only a few elementary operations.

A method is presented to compute values of geometric mean time Tg that uses only a few data points equispaced in the logarithm of time (or equispaced in time and weighted by 1/t) and a few elementary operations for the computation. The method has been tested on a large number of synthetic relaxation data and on actual NMR relaxation measurements in porous samples, using as few as four points (including the two points needed to normalize the relaxation for decay from 1.0 to 0) on each relaxation curve. This computation of the geometric-mean rate very adequately matches the synthetic data and the results of multiexponential inversion of many (or only a few) data points from NMR measurements. When many computations are needed in short times, as for voxel-by-voxel computations in magnetic resonance imaging (MRI) or for depth-by-depth computation in nuclear magnetism logging (NML) of oilwells, a very quickly computed estimate of Tg should be useful.

Algorithms↗

Ceramic microstructure detected by NMR relaxation and imaging of fluids in the pores.

NMR Relaxation and Imaging have been applied to study preparation processes of ceramic porous samples. Relaxation analysis gives a clear characterization of the materials, with high sensitivity. Differences in the method of preparation and steps as low as 25 degrees C in the firing temperatures are well detectable. Furthermore, the images permit distinguishing the different samples. The effects of the contrast in relaxation times dominate those due to the different porosities of the samples. Scanning Electron Microscopy confirms the interpretation that the changes in relaxation times are due to different pore space structures associated with the different firing temperatures. The higher the firing temperature, the larger are the pores and the higher is the amount of compact, sintered matrix, leading to higher relaxation times.

Ceramics↗

Quantitative determination of porosity: a local assessment by NMR imaging techniques.

The local determination of porosity is an extremely valuable target because of different applications in petrophysics. In fact, obtaining a reliable profile of porosity or saturations could considerably improve the evaluation of transport properties of porous media, especially if applied to multiphase flow test (i.e., for relative permeability characterisation). However, the best procedure to adopt for these kind of studies is currently under debate, involving different experimental choices both for acquisition and hardware solutions. The choice of a reliable procedure could be particularly important especially if heterogeneous samples (i.e., vugular or fractured carbonates) are approached. We have investigated selected carbonate cores, characterised by fractures and large vugs, using different instrumental solutions in order to assess usefulness of application of NMR imaging methods as a porosity measurement tool for heterogeneous samples. Local porosity data have been obtained and discussed relative to conventional measurements and petrographical aspects of rock samples.

Carbonates↗

Taking, processing, and interpreting spin-echo data in porous media and tissues.

Measurements of T2 by the Carr-Purcell-Meiboom-Gill (CPMG) method without externally applied field gradients for fluids in porous media are affected by locally inhomogeneous fields from susceptibility differences. Diffusion leads to a substantial range of correlation times tau c for change of local field. Wide distributions often lead to the dependence of 1/T2 on tau (half pulse spacing) of the form 1/T2 approximately R1 + R2 tan-1 (R3 tau), while narrow distributions require the extra term (R2R3/R4)exp(-R4 tau). To determine tau-dependence, the effects of different ranges of data coverage can be minimized by using only data within the time range common to all measurements and by adding a virtual n = 0 point to each data set, where n is echo number and this point is determined by extrapolating echo amplitudes for the small tau values.

Animals↗

Water-air saturation changes in restricted geometries studied by proton relaxation.

The results are reported of a systemic T1 and T2 investigation of natural (sandstones) and artificial (microporous porcelain) porous media, after each step of a water desaturation process by centrifugation in air. The analysis of the relaxation curves permitted distinguishing well the different behaviour of the natural samples as compared to the artificial ones, which can be explained by the different pore structures. In both kinds of samples the evolution of the relaxation time distributions yielded a clear picture of the changes of the water distribution in the pore framework following the displacement process, until irreducible water saturation was attained. The results are compatible with the assumption of a fixed amount of surface area contributing to the relaxation of decreasing amounts of fluid as SW is reduced.

Air↗

A comparison among different inversion methods for multi-exponential NMR relaxation data.

The inversion of data to be represented by sums or continuous distributions of exponentials is done by different algorithms and compared. The published CONTIN program presents a chosen solution with an appropriate amount of detail. An in-house program EXDISTR allows operative choice of various constraints in order to show the consequences in quality of fit of allowing various features such as extra maxima or minima. Another in-house program based on the system theory approach, IDENT, treats the data as the output samples of a linear, time-invariant, autonomous dynamic system.

Algorithms↗

A dedicated MRI apparatus for medical and industrial applications.

So far, one of the major obstacles to the development of special purpose MRI imaging apparatus has been the lack of a magnetic technology that could cater to the need for a light, compact and efficient magnet, capable of providing the required field uniformity at a reasonable cost. Today, recent advances in magnet design permit attaining, with the use solely of ferrite, low-cost, small-scale scanners, which can open up new areas of application of MRI, in both medical and industrial fields. A novel apparatus (ARTOSCAN) is described and some examples of applications in different fields are shown. The apparatus has been designed specifically for the imaging of extremities, but possible applications on the industrial side are numerous and not yet all identified. Such a device could be used, for example, in the agricultural, food, and oil industries, where some of the needs for nondestructive quality-control devices could be fulfilled. Some tests have been performed that demonstrate the potential of the apparatus in the study of rock properties, of the drying process of pasta and wood, and to display flaws that could be present in ceramic materials before firing.

Equipment Design↗

Water 1H spin-lattice relaxation as a fingerprint of porous media.

The 1H spin-lattice relaxation curves of water in samples of natural porous media can be thought of as "fingerprints" of the porous samples. Also the whole of traditional petrophysical properties (permeability, irreducible water saturation, etc.) can be thought of as "fingerprints" of the porous samples. The characteristics of the pore space determine on one hand the relaxation curve shape, and on the other the petrophysical properties. The understanding of this correspondence can contribute to a better definition of the concept of the architecture of a porous medium. At this purpose we have obtained 1H spin-lattice relaxation curves from a collection of standard sandstone cores of known petrophysical properties and characterized by the same surface properties. The results corroborate the idea that the structure of relaxation curves contains information on the distance scale and on the architecture of the pore space, even if it is difficult to extract it without ambiguities. Different methods of curve fitting were performed and compared with the aim of getting the maximum information from the relaxation curves. Several aspects of this kind of investigation indicate the analogies between 1H response of water confined in porous media and in biological tissues.

Magnetic Resonance Spectroscopy↗

The water proton spin-lattice relaxation time measurements in liver samples from hepatectomized and sham-operated rats.

We report the proton spin-lattice relaxation times (T1) of rat liver samples taken at different times after partial hepatectomy. The T1 values obtained are compared with those of liver samples from sham-operated rats and of liver samples from rats that had not undergone any surgical treatment. The results show that surgical stress significantly influences the T1 values of sham-operated rats both in their absolute value and in their dependence on the time after the operation, while it induces only a modest early increase of the water content. Possible effects of liver regeneration on 1H-T1 are almost completely concealed by the changes due to the surgical operation. These results emphasize the importance of the choice of a suitable control for T1 measurements in biological systems.

Animals↗