[Automatic perimetry in neuro-ophthalmology].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to P Brusini.
Explore the source record for details and available documents.
PURPOSE: To describe a case of scleroretinal necrosis after a subconjunctival injection of gentamicin in a patient who had an episcleral retinal detachment that was surgically repaired. METHODS: Case presentation. RESULTS: Thinning of the sclera due to cryosurgery and the induced localized inflammatory response resulting from the surgical procedure, in addition to the effect of the sponge buckle itself, could have played an important role in accumulation and storage of gentamicin under and adjacent to the buckle after injection. The increasingly higher concentration of the drug under the buckle could have induced a greater penetration of gentamicin through the sclera, which could have been the cause of the scleral-chorio-retinal necrosis observed in this patient. CONCLUSIONS: Attention must be given to avoid side effects from subconjunctival injection of gentamicin.
PURPOSE: To correlate functional damage over time detected by standard automated perimetry (SAP) and frequency doubling technology (FDT) with central corneal thickness (CCT) in patients with ocular hypertension (OHT). METHODS: Seventy-eight OHT patients underwent CCT measurements, SAP, and FDT (the latter two also after 12 and 18 months). Patients were divided into three equally sized groups of 26 patients each: thin (< 540 microm), normal (540-580 microm), and thick cornea (> 580 microm). The frequency of abnormal FDT and SAP results was analyzed over time (Pearson chi2 test). RESULTS: Six of 26 patients with thin corneas (23.1%) presented an abnormal FDT test at baseline, compared to 1 of 26 (3.8%) in the normal thickness cornea group and 1 of 26 (3.8%) in the thick cornea group. After 12 months, the abnormal FDT tests were as follows, respectively: 9 of 26 (34.6%), 2 of 26 (7.7%), and 2 of 26 (7.7%). For SAP the abnormal results were as follows, respectively: 8 (30.1%), 5 (19.2%), and 2 (7.7%). After 18 months, the abnormal FDT tests were as follows, respectively: 16 (61.5%), 5 (19.2%), and 5 (19.2%). For SAP, the abnormal results were as follows, respectively: 10 (38.5%), 5 (19.2%), and 2 (7.7%). CONCLUSIONS: OHT patients with thinner corneas have a greater risk of developing functional damage over time.
PURPOSE: To evaluate the ability of scanning laser polarimetry (SLP) with a fixed corneal polarization compensator (GDx-FCC Nerve Fiber Analyzer) compared to one with a variable one (GDx-VCC) in the discrimination between healthy and early glaucomatous eyes. METHODS: Forty patients with early glaucomatous visual field defects, having a mean deviation of 3.1-/+1.6 dB and a pattern standard deviation of 3.1-/+0.9 dB, and 40 controls underwent both GDx-FCC and GDx-VCC. One eye per patient was considered. The cut-off point, taken as the value dividing healthy from glaucomatous eyes with highest probability, was determined for each GDx parameter. Linear discriminant functions (LDFs) were separately developed for GDx-FCC and GDx-VCC parameters. Sensitivity, specificity, and area under the receiver operating characteristic curve (AROC) for discriminating between healthy and glaucomatous eyes were calculated for each GDx parameter, both according to the GDx normative database and after the selection of new cut-off points, and for the LDFs. RESULTS: All software-provided parameters showed low sensitivity and high specificity. The selection of new cut-off points improved the performance of all GDx parameters: VCC parameters performed better than FCC parameters; the largest AROCs were associated with the superior/nasal ratio for the GDx-FCC (0.86) and with the Number for the GDx-VCC (0.87). The LDFs provided an AROC of 0.89 with both the GDx-FCC and the GDx-VCC parameters. CONCLUSIONS: The GDx-VCC showed a higher ability in the early diagnosis of glaucoma when compared with the GDx-FCC. The individuation of the right cut-off point of selected parameters with both GDx settings performed better than the software-provided parameters, and comparably to the GDx parameters-based LDFs.
PURPOSE: To study the importance of the central corneal thickness (CCT) in patients with ocular hypertension in a 2-year follow-up. METHODS: A total of 110 subjects with ocular hypertension (intraocular pressure [IOP] >21 mmHg and normal automated visual field test) were admitted to the study. All patients periodically underwent the following tests: 1) circadian IOP curve; 2) standard automated perimetry (SAP, Humphrey 30-2 SITA test); 3) short wavelength automated perimetry (SWAP); 4) frequency doubling technology perimetry (FDT, N-30 threshold test); 5) nerve fiber layer analysis with GDx; 6) ibopamine test; 7) ultrasonic pachymetry. Patients were divided into three groups, based on corneal thickness. The frequency of abnormal tests within these groups was evaluated with the Pearson's chi2 test. Baseline IOP was corrected using the Doughty and Zaman formula. CCT was also considered as a continuous variable. A control group of 48 normal subjects was also considered. RESULTS: The mean CCT was 562.8 microm +/- 37.7. The difference with respect to normal subjects was statistically significant (p < 0.01). Using the correction formula, 43 eyes (39.1%) had an IOP <21 mmHg. Abnormal test results were more frequently found with FDT. The percentage of abnormal results was found to be inversely proportional to CCT. The other tests gave inconsistent or conflicting results. Using the values of CCT as a continuous variable, no significant association was found with the GDx number and the visual field indices. CONCLUSIONS: The results of our 2-year study confirm the importance of CCT measurement in the evaluation of the risk of developing glaucomatous damage.
This new method, based on the use of MD and CPSD (or CLV) visual field indices, can instantly classify not only the stage of glaucomatous visual field damage, but also the type of defect (localized, generalized or mixed). This system was used to study glaucomatous visual field defects in 500 automated tests, performed with either Humphrey 30-2 or Octopus G1 threshold tests. The most common defects found were mixed, and purely local defects were very unusual, especially in advanced glaucoma.
Explore the source record for details and available documents.