Search PubMed⌕ Search

Biomedical subjects

Natalia A Trayanova

Publications and source records attributed to Natalia A Trayanova.

7 recordsLinked to original sources

Asymmetry in membrane responses to electric shocks: insights from bidomain simulations.

Models of myocardial membrane dynamics have not been able to reproduce the experimentally observed negative bias in the asymmetry of transmembrane potential changes (DeltaVm) induced by strong electric shocks delivered during the action potential plateau. The goal of this study is to determine what membrane model modifications can bridge this gap between simulation and experiment. We conducted simulations of shocks in bidomain fibers and sheets with membrane dynamics represented by the LRd'2000 model. We found that in the fiber, the negative bias in DeltaVm asymmetry could not be reproduced by addition of electroporation only, but by further addition of hypothetical outward current, Ia, activated upon strong shock-induced depolarization. Furthermore, the experimentally observed rectangularly shaped positive DeltaVm, negative-to-positive DeltaVm ratio (asymmetry ratio) = approximately 2, electroporation occurring at the anode only, and the increase in positive DeltaVm caused by L-type Ca2+-channel blockade were reproduced in the strand only if Ia was assumed to be a part of K+ flow through the L-type Ca2+-channel. In the sheet, Ia not only contributed to the negative bias in DeltaVm asymmetry at sites polarized by physical and virtual electrodes, but also restricted positive DeltaVm. Inclusion of Ia and electroporation is thus the bridge between experiment and simulation.

Action Potentials↗

Mechanistic inquiry into decrease in probability of defibrillation success with increase in complexity of preshock reentrant activity.

Energy requirements for successful antiarrhythmia shocks are arrhythmia specific. However, it remains unclear why the probability of shock success decreases with increasing arrhythmia complexity. The goal of this research was to determine whether a diminished probability of shock success results from an increased number of functional reentrant circuits in the myocardium, and if so, to identify the responsible mechanisms. To achieve this goal, we assessed shock efficacy in a bidomain defibrillation model of a 4-mm-thick slice of canine ventricles. Shocks were applied between a right ventricular cathode and a distant anode to terminate either a single scroll wave (SSW) or multiple scroll waves (MSWs). From the 160 simulations conducted, dose-response curves were constructed for shocks given to SSWs and MSWs. The shock strength that yielded a 50% probability of success (ED(50)) for SSWs was found to be 13% less than that for MSWs, which indicates that a larger number of functional reentries results in an increased defibrillation threshold. The results also demonstrate that an isoelectric window exists after both failed and successful shocks; however, shocks of strength near the ED(50) value that were given to SSWs resulted in 16.3% longer isoelectric window durations than the same shocks delivered to MSWs. Mechanistic inquiry into these findings reveals that the two main factors underlying the observed relationships are 1) smaller virtual electrode polarizations in the tissue depth, and 2) differences in preshock tissue state. As a result of these factors, intramural excitable pathways leading to delayed breakthrough on the surface were formed earlier after shocks given to MSWs compared with SSWs and thus resulted in a lower defibrillation threshold for shocks given to SSWs.

Animals↗

Postshock arrhythmogenesis in a slice of the canine heart.

INTRODUCTION: Recent evidence has demonstrated that defibrillation shocks terminate or reset reentrant activity in the myocardium through the generation of virtual electrode polarization (VEP). Previous research has revealed that the shock establishes phase singularities (PSs) in the tissue via the VEP mechanism. The aim of this study was to examine, as a function of shock strength and electrode configuration, the relationship between end-shock PSs and the reentrant circuits established after failed defibrillation attempts. METHODS AND RESULTS: The study uses a complex three-dimensional finite-element bidomain model of a slice of the canine heart characterized by realistic geometry and fiber architecture and undergoing a single scroll wave. Defibrillation shocks of increasing strength are delivered through three different electrode configurations. The results demonstrated that >98% of all PSs have a lifetime of half a reentrant cycle or less. Stronger shocks result in a faster rate of annihilation of postshock PSs. For failed shocks, the surviving PSs underlie the activity of one or more scroll waves, which remain stationary in the slice. For all electrode configurations tested, the increase in shock strength leads to a rapid initial increase in the number of postshock reentries followed by a slower decrease; similar behavior is observed with regard to end-shock PSs. CONCLUSION: These results present new evidence regarding the mechanisms underlying failure of defibrillation shocks.

Animals↗

Termination of reentry by a long-lasting AC shock in a slice of canine heart: a computational study.

INTRODUCTION: A heart in fibrillation can be entrained by long-lasting alternating current (AC) stimuli, leading to defibrillation. To investigate the role entrainment plays in defibrillation, computer simulations of AC cardioversion in a three-dimensional slice of the canine heart were performed. METHODS AND RESULTS: A bidomain finite element model of a 1-mm thick slice across the ventricles of a canine heart was used to simulate termination of transmural reentry with AC shocks. Cardioversion defibrillation thresholds (DFTs) were determined for 200-msec (L) AC shocks at varying frequencies. At the DFT, the entire tissue is entrained by the AC shock. DFT decreases as the frequency of the long-lasting AC shock increases. We hypothesize that this decrease is due to the short period of the high-frequency AC waveform, leaving strong virtual electrode polarization (VEP) after the shock ends. To test this hypothesis, the end-shock VEP were compared for different frequencies, demonstrating stronger polarization as frequency increased. To examine whether entrainment by the long-lasting AC shock contributes to the VEP at the end of the shock, additional simulations were conducted using single-period (Z) AC waveforms. Z waveform DFTs were higher than L waveform DFTs; the Z waveform VEP was weaker than the L waveform VEP at the same frequency. This indicates that entrainment contributes to the development of stronger VEP and, thus, to lower DFT at high frequencies. CONCLUSION: This study offers for the first time a mechanistic insight into cardioversion with long-lasting AC shocks.

Animals↗

Computational techniques for solving the bidomain equations in three dimensions.

The bidomain equations are the most complete description of cardiac electrical activity. Their numerical solution is, however, computationally demanding, especially in three dimensions, because of the fine temporal and spatial sampling required. This paper methodically examines computational performance when solving the bidomain equations. Several techniques to speed up this computation are examined in this paper. The first step was to recast the equations into a parabolic part and an elliptic part. The parabolic part was solved by either the finite-element method (FEM) or the interconnected cable model model (ICCM). The elliptic equation was solved by FEM on a coarser grid than the parabolic problem and at a reduced frequency. The performance of iterative and direct linear equation system solvers was analyzed as well as the scalability and parallelizability of each method. Results indicate that the ICCM was twice as fast as the FEM for solving the parabolic problem, but when the total problem was considered, this resulted in only a 20% decrease in computation time. The elliptic problem could be solved on a coarser grid at one-quarter of the frequency at which the parabolic problem was solved and still maintain reasonable accuracy. Direct methods were faster than iterative methods by at least 50% when a good estimate of the extracellular potential was required. Parallelization over four processors was efficient only when the model comprised at least 500,000 nodes. Thus, it was possible to speed up solution of the bidomain equations by an order of magnitude with a slight decrease in accuracy.

Algorithms↗