Simplified high-performance liquid chromatographic method for determination of mizoribine in human serum.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to N Taenaka.
Explore the source record for details and available documents.
Pneumatic ventricular assist device (VAD) was utilized for cardiogenic shock after intracardiac operation in two children with complex cardiac anomalies based with single ventricle. In the first case (a 10-year-old), after a modified Fontan operation, VAD was placed between the functional left atrium and ascending aorta, serving as a "artificial single ventricle" with neither pumping chamber nor artificial support in the right side of the heart. The systemic circulation was maintained by keeping relatively high central venous pressure. In another child (a 3-year-old) who underwent repair of incompetent atrioventricular valve leaving intracardiac lesions, VAD was placed between the common atrium and ascending aorta, serving as a pump for both pulmonary and systemic circulation with regulation of pulmonary blood flow through an aortopulmonary Gore-Tex shunt. The circulatory assist with VAD was utilized for 5 and 6 days, respectively. Although weaning from the device was not feasible in both patients because of the pulmonary dysfunction, these experience showed the possible use of VAD for cardiogenic shock after surgery in patients with complex cardiac anomalies.
A high-performance liquid chromatographic method for the determination of amphotericin B concentrations in human serum without bilirubin interference was developed and compared with a microbiological assay. The high-performance liquid chromatographic assay utilized a reversed-phase trimethyl silica column, simple sample preparation, and visible detection. Reproducibility studies yielded coefficient-of-variation ranges from 1.02 to 2.11% for within-day precision and 2.88 to 4.32% for between-day precision. The correlation coefficient with the microbiological assay was 0.984 for amphotericin B.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A 47-yr-old woman with low cardiac output and dyspnea due to pulmonary hypertension associated with rheumatoid arthritis was treated with two vasodilators. Although nicardipine, a Ca-channel blocking agent, reduced the pulmonary artery pressure (PAP), it reduced simultaneously the arterial BP, resulting in fluid retention with a low urine output and persistent high CVP. In contrast, prostaglandin E1 (PGE1) reduced successfully both the PAP and CVP. Although the BP decreased, a satisfactory urine output was maintained. The cardiac output increased from 3 to 4.5 L/min. PGE1 may help reduce reversible pulmonary hypertension of collagen disease.
A forty-eight year-old man complained of upper abdominal pain and diarrhea with mucinous bloody stool. He had not been abroad. Except high fever, anemia, leukocytosis and elevated rate of erythrocyte sedimentation, laboratory findings were not abnormal. Gastrofiberscopy showed the protrusion of gastric mucosa with a hollow on its surface in the angle. Abdominal CT scan and echogram revealed an abscess in the right hepatic lobe and an abscess in the left lobe. Ulceration and small protrusion of the rectal mucosa were found by romanoscopy. Stool examinations could not reveal amebas, but serological test for amebiasis by the Ouchterlony method showed positive. Under the diagnosis of the perforation into the stomach of amebic liver abscess, he was treated with Metronidazole and tetracycline. But, as a diffuse shadow appeared in the right thoracic cavity on the chest x-ray films with bloody sputa, perforation of amebic liver abscess to the right thoracic cavity was suspected. Laparotomy showed the communication of the abscess to gastric lumen. The post operative course was uneventful. We reported a case with the rare complication of amebic liver abscess.
A fully automated high-performance liquid chromatographic column-switching system is presented for the determination of cyclosporin A in whole blood. After blood proteins were precipitated with acetonitrile, the supernatant was automatically loaded on to a cyanopropyl column for initial separation, and then the fraction containing cyclosporin A was loaded on to a trimethylsilica column for final separation and quantitation. Cyclosporin A was detected by ultraviolet absorption at 205 nm. The minimum detectable concentration of cyclosporin A was 5 ng/ml in 100 microliter of blood. The coefficient of variation of the method was 1.755, 1.748 and 0.655% in whole blood when spiked at the 170, 425 and 850 ng/ml levels, respectively. One assay was completed in 15 min.
The portal blood flow of a 70-yr-old man with suspected massive mesenteric infarction was measured using duplex scanning. The main portal flow was 109 ml/min, while cardiac output was 4.2 L/min. Laparotomy revealed a massive mesenteric infarction from proximal jejunum to rectum. Duplex scanning may be a useful method for studying the course of mesenteric infarction.
The efficacy of gabexate mesilate (FOY), a synthetic serine proteinase inhibitor, was compared with that of heparin in preventing the acceleration of bleeding after hemodialysis. Transfused blood volume (TBV) was measured 24 h before and after 24 dialyses in 14 bleeding patients with impaired hemostatic function. The predialysis TBV did not differ significantly between heparin and FOY groups; however, TBV was significantly (p less than .05) larger after heparin dialysis than after FOY dialysis. After dialysis, TBV was increased in eight of nine heparin patients, compared to only three of 15 FOY subjects (p less than .01). FOY is an effective agent and may decrease postdialysis bleeding complications in certain high-risk patients.
Explore the source record for details and available documents.
The effects of driving pressure (DP) and respiratory rate (RR) on mean airway pressure (Paw), PaCO2, and other respiratory variables were studied during high-frequency jet ventilation (HFJV) in anesthetized rabbits. The animals were tracheotomized and paralyzed, and various combinations of RR (4, 8, 12, and 16 Hz) and DP (0.5, 1.0, and 2.0 kg/cm2) were applied randomly with an inspiratory/expiratory ratio of 1.0. HFJV was delivered via a 2.5-Fr catheter through a T-attachment, using 100% oxygen, and a hot-wire flowmeter was connected to the outlet of the T-attachment for measurement of the minute volume (MV). Heart rate, arterial BP and CVP, respiratory variables, and arterial blood gases were monitored during the study. There were no direct correlations between PaCO2 and DP, MV, or RR. However, there was an inverse correlation between PaCO2 and tidal volume, and linear correlations were found between Paw and DP, and between DP and MV. It is concluded that HFJV over an RR range of 4 to 16 Hz depends mainly upon tidal volume. When the desired PaCO2 and Paw are determined, DP and RR can be calculated following the equations established in this study.
Explore the source record for details and available documents.
The authors evaluated the accuracy of a system to measure respiratory gas exchange on an on-line basis by comparing it with a gas collection method. The system incorporates a hot-wire flowmeter, a mass spectrometer, and a microcomputer. It performs on-line compensation for both transport delay and dynamic response of the mass spectrometer. Compensation of flow measurement for changing gas fractions also is performed. Excellent linear correlations were obtained between the two methods: 1) in animals during mechanical ventilation with room air (VO2:r = 0.995; VCO2:r = 0.993), and nitrous oxide in oxygen (VO2:r = 0.975; VCO2:r = 0.976); and 2) in men spontaneously breathing room air at different workloads (VO2:r = 0.999; VCO2:r = 0.998), and higher inspired oxygen fractions (FIO2 0.38 to 0.75) (VO2:r = 0.910; VCO2:r = 0.988). The authors consider that the system is suited for accurate and continuous measurement of respiratory gas exchange during mechanical ventilation, anesthesia, and exercise testing.
High-frequency jet ventilation using a jet injector located at the right mainstem bronchus was superimposed on standard mechanical ventilation to ventilate the injured lung of a patient with unilateral massive atelectasis secondary to pulmonary hemorrhage. This technique of differential ventilation markedly improved arterial oxygenation in this patient and may prove to be a simpler modality of respiratory support in patients who have respiratory failure from unilateral lung disease.