Search PubMed⌕ Search

Biomedical subjects

Mirian Skaf

Publications and source records attributed to Mirian Skaf.

4 recordsLinked to original sources

Retinal assessment using optical coherence tomography.

Over the 15 years since the original description, optical coherence tomography (OCT) has become one of the key diagnostic technologies in the ophthalmic subspecialty areas of retinal diseases and glaucoma. The reason for the widespread adoption of this technology originates from at least two properties of the OCT results: on the one hand, the results are accessible to the non-specialist where microscopic retinal abnormalities are grossly and easily noticeable; on the other hand, results are reproducible and exceedingly quantitative in the hands of the specialist. However, as in any other imaging technique in ophthalmology, some artifacts are expected to occur. Understanding of the basic principles of image acquisition and data processing as well as recognition of OCT limitations are crucial issues to using this equipment with cleverness. Herein, we took a brief look in the past of OCT and have explained the key basic physical principles of this imaging technology. In addition, each of the several steps encompassing a third generation OCT evaluation of retinal tissues has been addressed in details. A comprehensive explanation about next generation OCT systems has also been provided and, to conclude, we have commented on the future directions of this exceptional technique.

Anatomy, Cross-Sectional↗

Comparison of intravitreal versus posterior sub-Tenon's capsule injection of triamcinolone acetonide for diffuse diabetic macular edema.

PURPOSE: To compare the safety and efficacy of intravitreal versus posterior Sub-Tenon's capsule injection of triamcinolone acetonide for diffuse diabetic macular edema. DESIGN: Prospective, double-masked, randomized controlled trial. PARTICIPANTS: Twelve patients (24 eyes) with bilateral diffuse diabetic macular edema. INTERVENTION: One eye of each patient was randomly assigned to receive a single 4-mg triamcinolone acetonide intravitreal injection and the fellow eye to receive a 40-mg triamcinolone acetonide posterior Sub-Tenon's capsule injection. MAIN OUTCOME MEASURES: Changes in visual acuity and central macular thickness obtained using optical coherence tomography were measured during a 6-month follow-up. Potential treatment complications were monitored, including increases in intraocular pressure (IOP) and cataract progression. RESULTS: Both intravitreal and Sub-Tenon's capsule injections of triamcinolone acetonide resulted in significant but transient improvements in central macular thickness. The mean (+/-standard deviation [SD]) central macular thickness in eyes with intravitreal injection was significantly thinner than in the Sub-Tenon's capsule-injected eyes at 1 month (226.8+/-41.7 microm and 431.5+/-165.8 microm, respectively; P = 0.002) and 3 months (242.3 +/- 93.9 microm and 364.7+/-78.2 microm, respectively; P = 0.005) after triamcinolone acetonide injection. The mean visual acuity (logarithm of the minimum angle of resolution) in the intravitreally injected eyes was significantly better than in the Sub-Tenon's capsule-injected eyes at 3 months post injection (0.832+/-0.293 and 1.107+/-0.339, respectively; P = 0.004). Intraocular pressure did not show any significant difference between the 2 forms of triamcinolone acetonide delivery at any follow-up visit, and no eyes had IOPs >25 mmHg. CONCLUSIONS: The findings from our study neither advocate nor support the use of corticosteroids for the treatment of diabetic macular edema, but do imply that both intravitreal and Sub-Tenon's capsule injections of triamcinolone acetonide may be equally tolerated, with short-term performance clearly favoring the intravitreal (4 mg) more than the SBT capsule (40 mg) route for the anatomic and functional aspects of improvement tested in this investigation.

Adult↗

A single intraoperative sub-Tenon's capsule triamcinolone acetonide injection for the treatment of post-cataract surgery inflammation.

PURPOSE: To compare a single intraoperative sub-Tenon's capsule triamcinolone acetonide injection with steroid drops in the treatment of ocular inflammation after cataract surgery. DESIGN: Randomized, double-masked controlled trial. PARTICIPANTS: A total of 100 patients were randomized prospectively into 2 groups: 50 patients treated with 1% prednisolone eyedrops (control group A) and 50 patients treated with sub-Tenon's capsule triamcinolone (treatment group B). METHODS: All patients underwent phacoemulsification and intraocular posterior lens implantation. After surgery, patients were randomized to receive either (group B) an intraoperative 40 mg triamcinolone acetonide sub-Tenon's capsule injection or (group A) 1% prednisolone acetate eyedrops, according to the following schedule: 1 drop 4 times daily (week 1), 3 times daily (week 2), 2 times daily (week 3), once daily (week 4). To mask the study, group B received vehicle drops administered on a similar schedule, and group A received an intraoperative sub-Tenon's capsule injection of a 1 ml balanced salt solution. MAIN OUTCOME MEASURES: The main outcome measures included inflammation (cell, flare, ciliary flush), intraocular pressure, and lack of response. RESULTS: Triamcinolone was shown to have anti-inflammatory efficacy clinically equivalent to conventional 1% prednisolone eyedrops in reducing intraocular inflammation, as measured by clinical methods. Triamcinolone was found to be as safe as the prednisolone in terms of adverse effects, changes in visual acuity, intraocular pressure, and biomicroscopic and ophthalmoscopic variables. On the third, seventh, fourteenth, and twenty-eighth postoperative days, a significantly lower intraocular pressure (P<0.01) was noted in the triamcinolone group than in the prednisolone group. CONCLUSIONS: A single intraoperative 40-mg triamcinolone acetonide sub-Tenon's capsule injection demonstrated a clinically equivalent therapeutic response and ocular tolerance compared with 1% prednisolone drops in controlling postoperative inflammation after uncomplicated cataract surgery and merits further investigation.

Aged↗

Optical coherence tomography 3: Automatic delineation of the outer neural retinal boundary and its influence on retinal thickness measurements.

PURPOSE: To investigate the automatic delineation of the outer limits of the macular neural retina, by using the optical coherence tomography (OCT)-3 built-in software, and to determine its influence in assessing retinal thickness in the normal macula. METHODS: Retrospective analysis of the OCT3 data at a tertiary-care referral center was performed to study the automatic delineation of the outer neural retina boundary generated by the OCT built-in software. In parallel, a cross-sectional study was designed to compare retinal thickness measurements obtained at specific macular regions of nine normal eyes by the automatic measurement tool with those obtained using a manual-caliper-assisted technique. RESULTS: OCT data from 121 eyes were evaluated. Two parallel, linear highly reflective layers (HRL) were visible at the level of the outer retinal boundary in normal macular regions. Disappearance of the inner and maintenance of the outer HRL was noted in the presence of eye conditions affecting the external retinal layers. The automated software delineation for the outer retinal border was primarily guided by the presence of the inner HRL, whereas the correlation of the OCT findings with the expected clinical and angiographic features on eyes presenting specific macular conditions pointed toward a deeper retinal pigment epithelium-retina interface occurring at the level of the outer HRL. There was a statistically significant difference between the retinal thickness in specific normal macular regions obtained by the automatic measurement tool and the caliper-assisted technique in which the outer retinal border delineation was based on the outer HRL (P = 0.008, Wilcoxon signed rank test). CONCLUSIONS: Incorrect delineation of the outer neural retina boundary is occurring with the automated retinal thickness measurement tool of the OCT3 software. At specific regions of the normal macula, retinal thicknesses were significantly underestimated due to such misalignment.

Adolescent↗