Stability and function of glycosaminoglycans in porcine bioprosthetic heart valves.

Glycosaminoglycans (GAGs) are important structural and functional components in native aortic heart valves and in glutaraldehyde (Glut)-fixed bioprosthetic heart valves (BHVs). However, very little is known about the fate of GAGs within the extracellular matrix of BHVs and their contribution to BHV longevity. BHVs used in heart valve replacement surgery have limited durability due to mechanical failure and pathologic calcification. In the present study we bring evidence for the dramatic loss of GAGs from within the BHV cusp structure during storage in saline and both short- and long-term Glut fixation. In order to gain insight into role of GAGs, we compared properties of fresh and Glut-fixed porcine heart valve cusps before and after complete GAG removal. GAG removal resulted in significant morphological and functional tissue alterations, including decreases in cuspal thickness, reduction of water content and diminution of rehydration capacity. By virtue of this diminished hydration, loss of GAGs also greatly increased the "with-curvature" flexural rigidity of cuspal tissue. However, removal of GAGs did not alter calcification potential of BHV cups when implanted in the rat subdermal model. Controlling the extent of pre-implantation GAG degradation in BHVs and development of improved GAG crosslinking techniques are expected to improve the mechanical durability of future cardiovascular bioprostheses.

Animals↗

Correlation between heart valve interstitial cell stiffness and transvalvular pressure: implications for collagen biosynthesis.

It has been speculated that heart valve interstitial cells (VICs) maintain valvular tissue homeostasis through regulated extracellular matrix (primarily collagen) biosynthesis. VICs appear to be phenotypically plastic, inasmuch as they transdifferentiate into myofibroblasts during valve development, disease, and remodeling. Under normal physiological conditions, transvalvular pressures (TVPs) on the right and left side of the heart are vastly different. Hence, we hypothesize that higher left-side TVPs impose larger local tissue stress on VICs, which increases their stiffness through cytoskeletal composition, and that this relation affects collagen biosynthesis. To evaluate this hypothesis, isolated ovine VICs from the four heart valves were subjected to micropipette aspiration to assess cellular stiffness, and cytoskeletal composition and collagen biosynthesis were quantified by using the surrogates smooth muscle alpha-actin (SMA) and heat shock protein 47 (HSP47), respectively. VICs from the aortic and mitral valves were significantly stiffer (P < 0.001) than those from the pulmonary and tricuspid valves. Left-side isolated VICs contained significantly more (P < 0.001) SMA and HSP47 than right-side VICs. Mean VIC stiffness correlated well (r = 0.973) with TVP; SMA and HSP47 also correlated well (r = 0.996) with one another. Assays were repeated for VICs in situ, and, as with in vitro results, left-side VIC protein levels were significantly greater (P < 0.05). These findings suggest that VICs respond to local tissue stress by altering cellular stiffness (through SMA content) and collagen biosynthesis. This functional VIC stress-dependent biosynthetic relation may be crucial in maintaining valvular tissue homeostasis and also prove useful in understanding valvular pathologies.

Animals↗

Finite element implementation of a generalized Fung-elastic constitutive model for planar soft tissues.

Numerical simulations of the anisotropic mechanical properties of soft tissues and tissue-derived biomaterials using accurate constitutive models remain an important and challenging research area in biomechanics. While most constitutive modeling efforts have focused on the characterization of experimental data, only limited studies are available on the feasibility of utilizing those models in complex computational applications. An example is the widely utilized exponential constitutive model proposed by Fung. Although present in the biomechanics literature for several decades, implementation of this model into finite element (FE) simulations has been limited. A major reason for limited numerical implementations are problems associated with inherent numerical instability and convergence. To address this issue, we developed and applied two restrictions for a generalized Fung-elastic constitutive model necessary to achieve numerical stability. These are (1) convexity of the strain energy function, and (2) the condition number of material stiffness matrix set lower than a prescribed value. These constraints were implemented in the nonlinear regression used for constitutive model parameter estimation to the experimental biaxial mechanical data. We then implemented the generalized Fung-elastic model into a commercial FE code (ABAQUS, Pawtucket, RI, USA). Single element and multi-element planar biaxial test simulations were conducted to verify the accuracy and robustness of the implementation. Results indicated that numerical convergence and accurate FE implementation were consistently obtained. The present study thus presents an integrated framework for accurate and robust implementation of pseudo-elastic constitutive models for planar soft tissues. Moreover, since our approach is formulated within a general FE code, it can be straightforwardly adopted across multiple software platforms.

Anisotropy↗

Guidance of engineered tissue collagen orientation by large-scale scaffold microstructures.

The tensile strength and stiffness of load-bearing soft tissues are dominated by their collagen fiber orientation. While microgrooved substrates have demonstrated a capacity to orient cells and collagen in monolayer tissue culture, tissue engineering (TE) scaffolds are structurally distinct in that they consist of a three-dimensional (3-D) open pore network. It is thus unclear how the geometry of these open pores might influence cell and collagen orientation. In the current study we developed an in vitro model system for quantifying the capacity of large scale ( approximately 200 microm), geometrically well-defined open pores to guide cell and collagen orientation in engineered tissues. Non-degradable scaffolds exhibiting a grid of 200 microm wide rectangular pores (1:1, 2:1, 5:1, and 10:1 aspect ratios) were fabricated from a transparent epoxy resin via high-resolution stereolithography. The scaffolds (n=6 per aspect ratio) were surface modified to support cell adhesion by covalently grafting GRGDS peptides, sterilized, and seeded with neonatal rat skin fibroblasts. Following 4 weeks of static incubation, the resultant collagen orientation was assessed quantitatively by small angle light scattering (SALS), and cell orientation was evaluated by laser confocal and scanning electron microscopy. Cells adhered to the struts of the pores and proceeded to span the pores in a generally circumferential pattern. While the cell and collagen orientations within 1:1 aspect ratio pores were effectively random, higher aspect ratio rectangular pores exhibited a significant capacity to guide global cell and collagen orientation. Preferential alignment parallel to the long strut axis and decreased spatial variability were observed to occur with increasing pore aspect ratio. Intra-pore variability depended in part on the spatial uniformity of cell attachment around the perimeter of each pore achieved during seeding. Evaluation of diamond-shaped pores [Sacks, M.S. et al., 1997. J. Biomech. Eng. 119(1), 124-127] suggests that they are less sensitive to initial conditions of cell attachment than rectangular pores, and thus more effective in guiding engineered tissue cell and collagen orientation.

Animals↗

From stem cells to viable autologous semilunar heart valve.

BACKGROUND: An estimated 275,000 patients undergo heart valve replacement each year. However, existing solutions for valve replacement are complicated by the morbidity associated with lifelong anticoagulation of mechanical valves and the limited durability of bioprostheses. Recent advances in tissue engineering and our understanding of stem cell biology may provide a lifelong solution to these problems. METHODS AND RESULTS: Mesenchymal stem cells were isolated from ovine bone marrow and characterized by their morphology and antigen expression through immunocytochemistry, flow cytometry, and capacity to differentiate into multiple cell lineages. A biodegradable scaffold was developed and characterized by its tensile strength and stiffness as a function of time in cell-conditioned medium. Autologous semilunar heart valves were then created in vitro using mesenchymal stem cells and the biodegradable scaffold and were implanted into the pulmonary position of sheep on cardiopulmonary bypass. The valves were evaluated by echocardiography at implantation and after 4 months in vivo. Valves were explanted at 4 and 8 months and examined by histology and immunohistochemistry. Valves displayed a maximum instantaneous gradient of 17.2+/-1.33 mm Hg, a mean gradient of 9.7+/-1.3 mm Hg, an effective orifice area of 1.35+/-0.17 cm2, and trivial or mild regurgitation at implantation. Gradients changed little over 4 months of follow-up. Histology showed disposition of extracellular matrix and distribution of cell phenotypes in the engineered valves reminiscent of that in native pulmonary valves. CONCLUSIONS: Stem-cell tissue-engineered heart valves can be created from mesenchymal stem cells in combination with a biodegradable scaffold and function satisfactorily in vivo for periods of >4 months. Furthermore, such valves undergo extensive remodeling in vivo to resemble native heart valves.

Animals↗

The effects of cellular contraction on aortic valve leaflet flexural stiffness.

The aortic valve (AV) leaflet contains a heterogeneous interstitial cell population composed predominantly of myofibroblasts, which contain both fibroblast and smooth muscle cell characteristics. The focus of the present study was to examine aortic valve interstitial cell (AVIC) contractile behavior within the intact leaflet tissue. Circumferential strips of porcine AV leaflets were mechanically tested under flexure, with the AVIC maintained in the normal, contracted, and contraction-inhibited states. Leaflets were flexed both with (WC) and against (AC) the natural leaflet curvature, both before and after the addition of 90 mM KCl to elicit cellular contraction. In addition, a natural basal tonus was also demonstrated by treating the leaflets with 10 microM thapsigargin to completely inhibit AVIC contraction. Results revealed a 48% increase in leaflet stiffness with AVIC contraction (from 703 to 1040 kPa, respectively) when bent in the AC direction (p=0.004), while the WC direction resulted only in 5% increase (from 491 to 516.5 kPa, respectively--not significant) in leaflet stiffness in the active state. Also, the loss of basal tonus of the AVIC population with thapsigargin treatment resulted in 76% (AC, p=0.001) and 54% (WC, p=0.036) decreases in leaflet stiffness at 5 mM KCl levels, while preventing contraction with the addition of 90 mM KCl as expected. We speculate that the observed layer dependent effects of AVIC contraction are primarily due to varying ECM mechanical properties in the ventricularis and fibrosa layers. Moreover, while we have demonstrated that AVIC contractile ability is a significant contributor to AV leaflet bending stiffness, it most likely serves a role in maintaining AV leaflet tissue homeostasis that has yet to be elucidated.

Animals↗

Quantification of bladder smooth muscle orientation in normal and spinal cord injured rats.

Spinal cord injuries (SCI) often lead to severe bladder dysfunctions. Our previous studies have demonstrated that following SCI, rat bladder wall tissue became hypertrophied, significantly more compliant, and changed its mechanical behavior from orthotropic to isotropic. In order to elucidate the link between the tissue microstructure and mechanical properties of the wall, we have developed a novel semi-automated image analysis method to quantify smooth muscle bundle orientation and mass fraction in the bladder wall tissues from normal and 10 day-post-SCI rats. Results of the present study revealed that there were significant (p < 0.05) increases in smooth muscle area fractions as well as significantly (p < 0.001) fewer cell nuclei per muscle area in the SCI groups compared to the normal groups. Furthermore, while the normal rat bladders exhibited predominant smooth muscle orientation only in the longitudinal direction, the SCI rat bladders exhibited smooth muscles oriented in both the circumferential and longitudinal directions. These results provide first evidence that bladder smooth muscle cells exhibit hypertrophy rather than hyperplasia and developed a second, orthogonal orientation of smooth muscle bundles following SCI. The results of the present study corroborate our previous mechanical anisotropy data and provide the basis for development of structure-based constitutive models for urinary bladder wall tissue.

Animals↗

Molecular orientation of collagen in intact planar connective tissues under biaxial stretch.

Understanding of the mechanical behavior of collagenous tissues at different size scales is necessary to understand their physiological function as well as to guide their use as heterograft biomaterials. We conducted a first investigation of the kinematics of collagen at the molecular and fiber levels under biaxial stretch in an intact planar collagenous tissue. A synchrotron small angle X-ray scattering (SAXS) technique combined with a custom biaxial stretching apparatus was used. Collagen fiber behavior under biaxial stretch was then studied with the same specimens using small angle light scattering (SALS) under identical biaxial stretch states. Both native and glutaraldehyde modified bovine pericardium were investigated to explore the effects of chemical modification to collagen. Results indicated that collagen fiber and molecular orientation did not change under equibiaxial strain, but were observed to profoundly change under uniaxial stretch. Interestingly, collagen molecular strain initiated only after approximately 15% global tissue strain, potentially due to fiber-level reorganization occurring prior to collagen molecule loading. Glutaraldehyde treatment also did not affect collagen molecular strain behavior, indicating that chemical fixation does not alter intrinsic collagen molecular stiffness. No detectable changes in the angular distribution and D-period strain were found after 80 min of stress relaxation. It can be speculated that other mechanisms may be responsible for the reduction in stress with time under biaxial stretch. The results of this first study suggest that collagen fiber/molecular kinematics under biaxial stretch are more complex than under uniaxial deformation, and warrant future studies.

Animals↗

The independent role of cyclic flexure in the early in vitro development of an engineered heart valve tissue.

Tissue engineered heart valves (TEHV) are being investigated as an alternative to current non-viable prosthetic valves and valved conduits. Studies suggest that pulse duplicator bioreactors can stimulate TEHV development. In the current study, a model system was used to determine if cyclic flexure, a major mode of heart valve deformation, has independent effects on TEHV cell and extracellular matrix (ECM) development. Ovine vascular smooth muscle cells (SMC) were seeded for 30 h onto strips of non-woven 50:50 polyglycolic acid (PGA) and poly-L-lactic acid (PLLA) scaffold. After 4 days of incubation, SMC-seeded and unseeded scaffolds were either maintained under static conditions (static group), or subjected to unidirectional cyclic three-point flexure at a physiological frequency and amplitude in a bioreactor (flex group) for 3 weeks. After seeding or incubation, the effective stiffness (E) was measured, with SMC-seeded scaffolds further characterized by DNA, collagen, sulfated glycosaminoglycan (S-GAG), and elastin content, as well as by histology. The seeding period was over 90% efficient, with a significant accumulation of S-GAG, no significant change in E, and no collagen detected. Following 3 weeks of incubation, unseeded scaffolds exhibited no significant change in E in the flex or static groups. In contrast, E of SMC-seeded scaffolds increased 429% in the flex group (p<0.01) and 351% in the static group (p<0.01), with a trend of increased E, a 63% increase in collagen (p<0.05), increased vimentin expression, and a more homogenous transmural cell distribution in the flex versus static group. Moreover, a positive linear relationship (r2=0.996) was found between the mean E and mean collagen concentration. These results show that cyclic flexure can have independent effects on TEHV cell and ECM development, and may be useful in predicting the mechanical properties of TEHV constructed using novel scaffold materials.

Animals↗

The effects of collagen fiber orientation on the flexural properties of pericardial heterograft biomaterials.

Improving cardiac valve bioprostheses (BHV) utilizing heterograft biomaterials requires a better understanding of their mechanical behavior. Flexure is a major mode of deformation for BHV leaflets during valve operation, inducing more complex deformation patterns within the tissue compared to tensile loads. In this study, we investigated the relation between collagen fiber preferred direction and the resulting flexural properties of native and glutaraldehyde-treated bovine pericardium. 20 mm x 4 mm strips were cut from the presorted sheets of bovine pericardium and divided into four groups: two directions of collagen fiber orientation in two groups of native and chemically treated specimens. Specimens were flexed in two different directions using a three-point bending technique (ASAIO J. 45(1999)59) and their flexural mechanical response compared. Results indicated that: (1) the relationship between the applied flexing moment and change of curvature of specimens was non-linear in both native and chemically fixed groups, (2) there were no directional differences in flexural properties when the bovine pericardium is flexed towards either the epi-pericardial or visceral surfaces in both native and chemically fixed specimens, (3) native and chemically fixed bovine pericardium were stiffer when flexed perpendicular to local preferred collagen fiber direction, and (4) chemical fixation increased the flexural rigidity of bovine pericardium. Results of this study indicate that the flexural properties of bovine pericardium are dominated by inter-fiber cross-links as opposed to the stiffness of the collagen fibers themselves. These findings can be used to guide the development of novel chemical treatment methods that seek to optimize biomechanical properties of heterograft biomaterials.

Animals↗

Biaxial mechanical properties of muscle-derived cell seeded small intestinal submucosa for bladder wall reconstitution.

Bladder wall replacement remains a challenging problem for urological surgery due to leakage, infection, stone formation, and extensive time needed for tissue regeneration. To explore the feasibility of producing a more functional biomaterial for bladder reconstitution, we incorporated muscle-derived cells (MDC) into small intestinal submucosa (SIS) scaffolds. MDC were harvested from mice hindleg muscle, transfected with a plasmid encoding for beta-galactosidase, and placed into single-layer SIS cell culture inserts. Twenty-five MDC and/or SIS specimens were incubated at 37 degrees C for either 10 or 20 days. After harvesting, mechanical properties were characterized using biaxial testing, and the areal strain under 1 MPa peak stress used to quantify tissue compliance. Histological results indicated that MDC migrated throughout the SIS after 20 days. The mean (+/-SE) areal strain of the 0 day control group was 0.182 +/- 0.027 (n=5). After 10 days incubation, the mean (+/-SE) areal strain in MDC/SIS was 0.247 +/- 0.014 (n=5) compared to 10 day control SIS 0.200 +/- 0.024 (n=6). After 20 days incubation, the mean areal strain of MDC/SIS was 0.255 +/- 0.019 (n=5) compared to control SIS 0.170 +/- 0.025 (n=5). Both 10 and 20 days seeded groups were significantly different (p=0.027) than that of incubated SIS alone, but were not different from each other. These results suggest that MDC growth was supported by SIS and that initial remodeling of the SIS ECM had occurred within the first 10 days of incubation, but may have slowed once the MDC had grown to confluence within the SIS.

Animals↗

Cyclic loading response of bioprosthetic heart valves: effects of fixation stress state on the collagen fiber architecture.

Biologically derived, chemically modified collagenous tissues are being increasingly used to fabricate cardiac valve prostheses and as biomaterials in cardiovascular repair. A stress-free state during chemical modification has been shown to preserve the collagen fiber architecture of the native tissue, potentially preserving native mechanical properties and improving prostheses durability. However, it is not known if the native collagen fiber architecture is stable during long-term in vivo operation. To address this question, we obtained porcine aortic valves chemically treated at (i) 0 mmHg transvalvular pressure (with 40 mmHg aortic pressure) and (ii) 4 mmHg transvalvular pressure, then subjected the valves to 0, 1 x 10(6), 50 x 10(6), and 200 x 10(6) in vitro accelerated wear testing (AWT) cycles. The resulting changes in collagen fiber architecture were quantified using small angle light scattering analysis (SALS). SALS measurements indicated that collagen fibers in the 0 mmHg pressure-fixed leaflets became more aligned between 1 x 10(6) and 50 x 10(6) AWT cycles. In contrast, only minor changes (not statistically significant) in collagen fiber orientation occurred in the 4 mmHg pressure-fixed valvular tissue with cycling. It was also noted that although the 0 mmHg group was fixed without transvalvular pressure, distention of the root induced significant changes in collagen structure of the leaflets. Overall, our observations suggest that the native collagen fiber crimp of the 0 mmHg pressure-fixed leaflets were rapidly lost after only 50 x 10(6) AWT cycles (equivalent to approximately 1.6 patient years) and thus may not be maintained over a sufficient period of time to be clinically beneficial. Further, the collagen structure of the native aortic valve is exquisitely sensitive to dimensional change in the aortic root-independent of the presence of transvalvular pressure. Our findings also suggest that without in vivo remodeling, any collagenous tissue used to fabricate BHV may undergo similar degenerative, irreversible changes in vivo.

Aortic Valve↗

Preparation and characterization of highly porous, biodegradable polyurethane scaffolds for soft tissue applications.

In the engineering of soft tissues, scaffolds with high elastance and strength coupled with controllable biodegradable properties are necessary. To fulfill such design criteria we have previously synthesized two kinds of biodegradable polyurethaneureas, namely poly(ester urethane)urea (PEUU) and poly(ether ester urethane)urea (PEEUU) from polycaprolactone, polycaprolactone-b-polyethylene glycol-b-polycaprolactone, 1,4-diisocyanatobutane and putrescine. PEUU and PEEUU were further fabricated into scaffolds by thermally induced phase separation using dimethyl sulfoxide (DMSO) as a solvent. The effect of polymer solution concentration, quenching temperature and polymer type on pore morphology and porosity was investigated. Scaffolds were obtained with open and interconnected pores having sizes ranging from several mum to more than 150 microm and porosities of 80-97%. By changing the polymer solution concentration or quenching temperature, scaffolds with random or oriented tubular pores could be obtained. The PEUU scaffolds were flexible with breaking strains of 214% and higher, and tensile strengths of approximately 1.0 MPa, whereas the PEEUU scaffolds generally had lower strengths and breaking strains. Scaffold degradation in aqueous buffer was related to the porosity and polymer hydrophilicity. Smooth muscle cells were filtration seeded in the scaffolds and it was shown that both scaffolds supported cell adhesion and growth, with smooth muscle cells growing more extensively in the PEEUU scaffold. These biodegradable and flexible scaffolds demonstrate potential for future application as cell scaffolds in cardiovascular tissue engineering or other soft tissue applications.

Absorbable Implants↗

In vitro dynamic strain behavior of the mitral valve posterior leaflet.

Knowledge of mitral valve (MV) mechanics is essential for the understanding of normal MV function, and the design and evaluation of new surgical repair procedures. In the present study, we extended our investigation of MV dynamic strain behavior to quantify the dynamic strain on the central region of the posterior leaflet. Native porcine MVs were mounted in an in-vitro physiologic flow loop. The papillary muscle (PM) positions were set to the normal, taut, and slack states to simulate physiological and pathological PM positions. Leaflet deformation was measured by tracking the displacements of 16 small markers placed in the central region of the posterior leaflet. Local leaflet tissue strain and strain rates were calculated from the measured displacements under dynamic loading conditions. A total of 18 mitral valves were studied. Our findings indicated the following: (1) There was a rapid rise in posterior leaflet strain during valve closure followed by a plateau where no additional strain (i.e., no creep) occurred. (2) The strain field was highly anisotropic with larger stretches and stretch rates in the radial direction. There were negligible stretches, or even compression (stretch < 1) in the circumferential direction at the beginning of valve closure. (3) The areal strain curves were similar to the stretches in the trends. The posterior leaflet showed no significant differences in either peak stretches or stretch rates during valve closure between the normal, taut, and slack PM positions. (4) As compared with the anterior leaflet, the posterior leaflet demonstrated overall lower stretch rates in the normal PM position. However, the slack and taut PM positions did not demonstrate the significant difference in the stretch rates and areal strain rates between the posterior leaflet and the anterior leaflet. The MV posterior leaflet exhibited pronounced mechanically anisotropic behavior Loading rates of the MV posterior leaflet were very high. The PM positions influenced neither peak stretch nor stretch rates in the central area of the posterior leaflet. The stretch rates and areal strain rates were significantly lower in the posterior leaflet than those measured in the anterior leaflet in the normal PM position. However, the slack and taut PM positions did not demonstrate the significant differences between the posterior leaflet and the anterior leaflet. We conclude that PM positions may influence the posterior strain in a different way as compared to the anterior leaflet.

Animals↗

Effects of boundary conditions on the estimation of the planar biaxial mechanical properties of soft tissues.

Evaluation and simulation of the multiaxial mechanical behavior of native and engineered soft tissues is becoming more prevalent. In spite of this growing use, testing methods have not been standardized and methodologies vary widely. The strong influence of boundary conditions were recently underscored by Waldman et al. [2002, J. Materials Science: Materials in Medicine 13, pp. 933-938] wherein substantially different experimental results were obtained using different sample gripping methods on the same specimens. As it is not possible to experimentally evaluate the effects of different biaxial test boundary conditions on specimen internal stress distributions, we conducted numerical simulations to explore these effects. A nonlinear Fung-elastic constitutive model (Sun et al., 2003, JBME 125, pp. 372-380, which fully incorporated the effects of in-plane shear, was used to simulate soft tissue mechanical behavior. Effects of boundary conditions, including varying the number of suture attachments, different gripping methods, specimen shapes, and material axes orientations were examined. Results demonstrated strong boundary effects with the clamped methods, while suture attachment methods demonstrated minimal boundary effects. Suture-based methods appeared to be best suited for biaxial mechanical tests of biological materials. Moreover, the simulations demonstrated that Saint-Venant's effects depended significantly on the material axes orientation. While not exhaustive, these comprehensive simulations provide experimentalists with additional insight into the stress-strain fields associated with different biaxial testing boundary conditions, and may be used as a rational basis for the design of biaxial testing experiments.

Animals↗

Simulated bioprosthetic heart valve deformation under quasi-static loading.

For more than 40 years, the replacement of diseased natural heart valves with prosthetic devices has dramatically extended the quality and length of the lives of millions of patients worldwide. However, bioprosthetic heart valves (BHV) continue to fail due to structural failure resulting from poor tissue durability and faulty design. Clearly, an in-depth understanding of the biomechanical behavior of BHV at both the tissue and functional prosthesis levels is essential to improving BHV design and to reduce rates of failure. In this study, we simulated quasi-static BHV leaflet deformation under 40, 80, and 120 mm Hg quasi-static transvalvular pressures. A Fung-elastic material model was used that incorporated material parameters and axes derived from actual leaflet biaxial tests and measured leaflet collagen fiber structure. Rigorous experimental validation of predicted leaflet strain field was used to validate the model results. An overall maximum discrepancy of 2.36% strain between the finite element (FE) results and experiment measurements was obtained, indicating good agreement between computed and measured major principal strains. Parametric studies utilizing the material parameter set from one leaflet for all three leaflets resulted in substantial variations in leaflet stress and strain distributions. This result suggests that utilization of actual leaflet material properties is essential for accurate BHV FE simulations. The present study also underscores the need for rigorous experimentation and accurate constitutive models in simulating BHV function and design.

Animals↗

Biodegradable poly(ether ester urethane)urea elastomers based on poly(ether ester) triblock copolymers and putrescine: synthesis, characterization and cytocompatibility.

Polymers with elastomeric mechanical properties, tunable biodegradation properties and cytocompatibility would be desirable for numerous biomedical applications. Toward this end a series of biodegradable poly(ether ester urethane)urea elastomers (PEEUUs) based on poly(ether ester) triblock copolymers were synthesized and characterized. Poly(ether ester) triblock copolymers were synthesized by ring-opening polymerization of epsilon-caprolactone with polyethylene glycol (PEG). PEEUUs were synthesized from these triblock copolymers and butyl diisocyanate, with putrescine as a chain extender. PEEUUs exhibited low glass transition temperatures and possessed tensile strengths ranging from 8 to 20MPa and breaking strains from 325% to 560%. Increasing PEG length or decreasing poly(caprolactone) length in the triblock segment increased PEEUU water absorption and biodegradation rate. Human umbilical vein endothelial cells cultured in a medium supplemented with PEEUU biodegradation solution suggested a lack of degradation product cytotoxicity. Endothelial cell adhesion to PEEUUs was less than 60% of tissue culture polystyrene and was inversely related to PEEUU hydrophilicity. Surface modification of PEEUUs with ammonia gas radio-frequency glow discharge and subsequent immobilization of the cell adhesion peptide Arg-Gly-Asp-Ser increased endothelial adhesion to a level equivalent to tissue culture polystyrene. These biodegradable PEEUUs thus possessed properties that would be amenable to applications where high strength and flexibility would be desirable and exhibited the potential for tuning with appropriate triblock segment selection and surface modification.

Absorbable Implants↗

Design and hydrodynamic evaluation of a novel pulsatile bioreactor for biologically active heart valves.

Biologically active heart valves (tissue engineered and recellularized tissue-derived heart valves) have the potential to offer enhanced function when compared to current replacement value therapies since they can possibly remodel, and grow to meet the needs of the patient, and not require chronic medication. However, this technology is still in its infancy and many fundamental questions remain as to how these valves will function in vivo. It has been shown that exposing biologically active tissue constructs to pulsatile pressures and flows during in vitro culture produces enhanced extracellular matrix protein expression and cellularity, although the ideal hydrodynamic conditioning regime is as yet unknown. Moreover, in vitro organ-level studies of living heart valves aimed at studying the remodeling processes require environments that can accurately reproduce in vivo hemodynamics under sterile conditions. To this end, we have developed a system to study the effects of subjecting biologically active heart valves to highly controlled pulsatile pressure and flow waveforms under sterile conditions. The device fits inside a standard incubator and utilizes a computer-controlled closed loop feedback system to provide a high degree of control. The mean pressure, mean flow rate, driving frequency, and shape of the pulsatile pressure waveform can be changed automatically in order to simulate both physiologic and nonphysiologic hemodynamic conditions. Extensive testing and evaluation demonstrated the device's ability to subject a biologically active heart valve to highly controlled pulsatile waveforms that can be modulated during the course of sterile incubation.

Bioprosthesis↗