Effects of collagen fiber orientation on the response of biologically derived soft tissue biomaterials to cyclic loading.

In the present study, the effects of initial collagen fiber orientation on the medium-term (up to 50 x 10(6) cycles) fatigue response of heart valve soft tissue biomaterials was investigated. Glutaraldehyde treated bovine pericardium (GLBP), preselected for uniform structure and collagen fiber orientation, was used as the representative heart valve biomaterial. Using specialized instrumentation, GLBP specimens were subjected to cyclic tensile loading to maximum stress levels of 500 +/- 50 kPa at a frequency of 22 Hz. Two sample groups were examined, one with the preferred collagen fiber direction parallel (PD) and perpendicular (XD) to the direction of applied strain. The primary findings indicated that GLBP fatigue response was highly sensitive to the direction of loading with respect to fiber orientation. Specifically, when loading perpendicular to the preferred collagen fiber orientation, fiber reorientation is the dominant mechanism. In contrast, when loaded parallel to the preferred fiber direction a reduction in both collagen fiber crimp and fiber reorientation occurred. Moreover, alterations in the degree and direction of mechanical anisotropy can be inducted by cyclic loading when specimens are loaded perpendicular to the preferred fiber direction. Fourier Transform Infrared Spectroscopy (FT-IR) results indicate that molecular-level damage to collagen occurs in both groups after only 20 x 10(6) cycles. Taken as a whole, the results of this study suggest that initial collagen orientation plays a critical role in bioprosthetic heart valve biomaterial fatigue response.

Animals↗

The relation between collagen fibril kinematics and mechanical properties in the mitral valve anterior leaflet.

We have recently demonstrated that the mitral valve anterior leaflet (MVAL) exhibited minimal hysteresis, no strain rate sensitivity, stress relaxation but not creep (Grashow et al., 2006, Ann Biomed Eng., 34(2), pp. 315-325; Grashow et al., 2006, Ann Biomed. Eng., 34(10), pp. 1509-1518). However, the underlying structural basis for this unique quasi-elastic mechanical behavior is presently unknown. As collagen is the major structural component of the MVAL, we investigated the relation between collagen fibril kinematics (rotation and stretch) and tissue-level mechanical properties in the MVAL under biaxial loading using small angle X-ray scattering. A novel device was developed and utilized to perform simultaneous measurements of tissue level forces and strain under a planar biaxial loading state. Collagen fibril D-period strain (epsilonD) and the fibrillar angular distribution were measured under equibiaxial tension, creep, and stress relaxation to a peak tension of 90 N/m. Results indicated that, under equibiaxial tension, collagen fibril straining did not initiate until the end of the nonlinear region of the tissue-level stress-strain curve. At higher tissue tension levels, epsilonD increased linearly with increasing tension. Changes in the angular distribution of the collagen fibrils mainly occurred in the tissue toe region. Using epsilonD, the tangent modulus of collagen fibrils was estimated to be 95.5+/-25.5 MPa, which was approximately 27 times higher than the tissue tensile tangent modulus of 3.58+/-1.83 MPa. In creep tests performed at 90 N/m equibiaxial tension for 60 min, both tissue strain and epsilonD remained constant with no observable changes over the test length. In contrast, in stress relaxation tests performed for 90 min epsilonD was found to rapidly decrease in the first 10 min followed by a slower decay rate for the remainder of the test. Using a single exponential model, the time constant for the reduction in collagen fibril strain was 8.3 min, which was smaller than the tissue-level stress relaxation time constants of 22.0 and 16.9 min in the circumferential and radial directions, respectively. Moreover, there was no change in the fibril angular distribution under both creep and stress relaxation over the test period. Our results suggest that (1) the MVAL collagen fibrils do not exhibit intrinsic viscoelastic behavior, (2) tissue relaxation results from the removal of stress from the fibrils, possibly by a slipping mechanism modulated by noncollagenous components (e.g. proteoglycans), and (3) the lack of creep but the occurrence of stress relaxation suggests a "load-locking" behavior under maintained loading conditions. These unique mechanical characteristics are likely necessary for normal valvular function.

Animals↗

An experimentally derived stress resultant shell model for heart valve dynamic simulations.

In order to achieve a more realistic and accurate computational simulation of native and bioprosthetic heart valve dynamics, a finite shell element model was developed. Experimentally derived and uncoupled in-plane and bending behaviors were implemented into a fully nonlinear stress resultant shell element. Validation studies compared the planar biaxial extension and three-point bending simulations to the experimental data and demonstrated excellent fidelity. Dynamic simulations of a pericardial bioprosthetic heart valve with the developed shell element model showed significant differences in the deformation characteristics compared to the simulation with an assumed isotropic bending model. The new finite shell element model developed in the present study can also incorporate various types of constitutive models and is expected to help us to understand the complex dynamics of native and bioprosthetic heart valve function in physiological and pathological conditions.

Animals↗

Planar biaxial creep and stress relaxation of the mitral valve anterior leaflet.

A fundamental assumption in mitral valve (MV) therapies is that a repaired or replaced valve should mimic the functionality of the native valve as closely as possible. Thus, improvements in valvular treatments are dependent on the establishment of a complete understanding of the function and mechanical properties of the native normal MV. In a recent study [Grashow et al. ABME 34(2), 2006] we demonstrated that the planar biaxial stress-strain relationship of the MV anterior leaflet (MVAL) exhibited minimal hysteresis and a stress-strain response independent of strain rate, suggesting that MVAL could be modeled as a "quasi-elastic" material. The objective of our current study was to expand these results to provide a more complete picture of the time-dependent mechanical properties of the MVAL. To accomplish this, biaxial stress-relaxation and creep studies were performed on porcine MVAL specimens. Our primary finding was that while the MVAL leaflet exhibited significant stress relaxation, it exhibited negligible creep over the 3-h test. These results furthered our assertion that the MVAL functionally behaves not as a linear or non-linear viscoelastic material, but as an anisotropic quasi-elastic material. These results appear to be unique in the soft tissue literature; suggesting that valvular tissues are unequalled in their ability to withstand significant loading without time-dependent material effects. Moreover, insight into these specialized characteristics can help guide and inform efforts directed toward surgical repair and engineered valvular tissue replacements.

Animals↗

Cyclic flexure and laminar flow synergistically accelerate mesenchymal stem cell-mediated engineered tissue formation: Implications for engineered heart valve tissues.

Bone marrow-derived mesenchymal stem cells (BMSCs) are relatively accessible and exhibit a pluripotency suitable for cardiovascular applications such as tissue-engineered heart valves (TEHVs). Recently, Sutherland et al. [From stem cells to viable autologous semilunar heart valve. Circulation 2005; 111(21): 2783-91] demonstrated that BMSC-seeded TEHV can successfully function as pulmonary valve substitutes in juvenile sheep for at least 8 months. Toward determining appropriate mechanical stimuli for use in BMSC-seeded TEHV cultivation, we investigated the independent and coupled effects of two mechanical stimuli physiologically relevant to heart valves-cyclic flexure and laminar flow (i.e. fluid shear stress)-on BMSC-mediated tissue formation. BMSC isolated from juvenile sheep were expanded and seeded onto rectangular strips of nonwoven 50:50 blend poly(glycolic acid) (PGA) and poly(l-lactic acid) (PLLA) scaffolds. Following 4 days static culture, BMSC-seeded scaffolds were loaded into a novel flex-stretch-flow (FSF) bioreactor and incubated under static (n=12), cyclic flexure (n=12), laminar flow (avg. wall shear stress=1.1505 dyne/cm(2); n=12) and combined flex-flow (n=12) conditions for 1 (n=6) and 3 (n=6) weeks. By 3 weeks, the flex-flow group exhibited dramatically accelerated tissue formation compared with all other groups, including a 75% higher collagen content of 844+/-278 microg/g wet weight (p<0.05), and an effective stiffness (E) value of 948+/-233 kPa. Importantly, collagen and E values were not significantly different from values measured for vascular smooth muscle cell (SMC) -seeded scaffolds incubated under conditions of flexure alone [Engelmayr et al. The independent role of cyclic flexure in the early in vitro development of an engineered heart valve tissue. Biomaterials 2005; 26(2): 175-87], suggesting that BMSC-seeded TEHV can be optimized to yield results comparable to SMC-seeded TEHV. We thus demonstrated that cyclic flexure and laminar flow can synergistically accelerate BMSC-mediated tissue formation, providing a basis for the rational design of in vitro conditioning regimens for BMSC-seeded TEHV.

Animals↗

A planar biaxial constitutive relation for the luminal layer of intra-luminal thrombus in abdominal aortic aneurysms.

The rupture risk of abdominal aortic aneurysms (AAAs) is thought to be associated with increased levels of wall stress. Finite element analysis (FEA) allows the prediction of wall stresses in a patient-specific, non-invasive manner. We have recently shown that it is important to include the intra-luminal thrombus (ILT), present in approximately 70% of AAA, into FEA simulations of AAA. All FEA simulations to date assume an isotropic, homogeneous material behavior for this material. The purpose of this work was to investigate the multi-axial biomechanical behavior of ILT and to derive an appropriate constitutive relation. We performed planar biaxial testing on the luminal layer of nine ILT specimens obtained fresh in the operating room (9 patients, mean age 71+/-4.5 years, mean diameter 5.9+/-0.4 cm), and a constitutive relation was derived from this data. Peak stretch and maximum tangential modulus (MTM) values were recorded for the equibiaxial protocol in both the circumferential (theta) and longitudinal (L) directions. Stress contour plots were used to investigate the presence of mechanical anisotropy, after which an appropriate strain energy function was fit to each of the specimen datasets. The peak stretch values for the luminal layer of the ILT were (mean+/-SEM) 1.18+/-0.02 and 1.13+/-0.02 in the theta and L directions, respectively (p=0.14). The MTM values were 20+/-2 and 23+/-3N/cm(2) in the theta and L directions, respectively (p=0.37). From these results and our observation of the symmetry of the stress contour plots for each specimen, we concluded that the use of an isotropic strain energy function for ILT is appropriate. Each specimen data set was then fit to a second-order polynomial strain energy function of the first invariant of the left Cauchy-Green strain tensor, resulting in an accurate fit (average R(2)=0.92+/-0.02; range 0.80-0.99). Comparison of our previously reported, uniaxially derived constitutive relation with the biaxially derived relation derived here shows large differences in the predicted mechanical response, underscoring the importance of the appropriate experimental methods used to derive constitutive relations. Further work is merited in an effort to produce more accurate predictions of wall stresses in patient-specific AAA, and viscoelastic behaviors of the ILT.

Aged↗

Transforming growth factor-beta1 modulates extracellular matrix production, proliferation, and apoptosis of endothelial progenitor cells in tissue-engineering scaffolds.

BACKGROUND: Valvular endothelial cells and circulating endothelial progenitor cells (EPCs) can undergo apparent phenotypic change from endothelial to mesenchymal cell type. Here we investigated whether EPCs can promote extracellular matrix formation in tissue engineering scaffolds in response to transforming growth factor (TGF)-beta1. Method and Results- Characterized ovine peripheral blood EPCs were seeded onto poly (glycolic acid)/poly (4-hydroxybutyrate) scaffolds for 5 days. After seeding at 2 x 10(6) cells/cm2, scaffolds were incubated for 5 days in a roller bottle, with or without the addition of TGF-beta1. After seeding at 15 x 10(6) cells/cm2, scaffolds were incubated for 10 days in a roller bottle with or without the addition of TGF-beta1 for the first 5 days. Using immunofluorescence and Western blotting, we demonstrated that EPCs initially exhibit an endothelial phenotype (ie, CD31+, von Willebrand factor+, and alpha-smooth muscle actin (SMA)-) and can undergo a phenotypic change toward mesenchymal transformation (ie, CD31+ and alpha-SMA+) in response to TGF-beta1. Scanning electron microscopy and histology revealed enhanced tissue formation in EPC-TGF-beta1 scaffolds. In both the 10- and 15-day experiments, EPC-TGF-beta1 scaffolds exhibited a trend of increased DNA content compared with unstimulated EPC scaffolds. TGF-beta1-mediated endothelial to mesenchymal transformation correlated with enhanced expression of laminin and fibronectin within scaffolds evidenced by Western blotting. Strong expression of tropoelastin was observed in response to TGF-beta1 equal to that in the unstimulated EPC. In the 15-day experiments, TGF-beta1-stimulated scaffolds revealed dramatically enhanced collagen production (types I and III) and incorporated more 5-bromodeoxyuridine and TUNEL staining compared with unstimulated controls. CONCLUSIONS: Stimulation of EPC-seeded tissue engineering scaffolds with TGF-beta1 in vitro resulted in a more organized cellular architecture with glycoprotein, collagen, and elastin synthesis, and thus noninvasively isolated EPCs coupled with the pleiotropic actions of TGF-beta1 could offer new strategies to guide tissue formation in engineered cardiac valves.

Actins↗

Design and analysis of tissue engineering scaffolds that mimic soft tissue mechanical anisotropy.

Tissue engineered constructs must exhibit tissue-like functional properties, including mechanical behavior comparable to the native tissues they are intended to replace. Moreover, the ability to reversibly undergo large strains can help to promote and guide tissue growth. Electrospun poly (ester urethane) ureas (ES-PEUU) are elastomeric and allow for the control of fiber diameter, porosity, and degradation rate. ES-PEUU scaffolds can be fabricated to have a well-aligned fiber network, which is important for applications involving mechanically anisotropic soft tissues. We have developed ES-PEUU scaffolds under variable speed conditions and modeled the effects of fiber orientation on the macro-mechanical properties of the scaffold. To illustrate the ability to simulate native tissue mechanical behavior, we demonstrated that the high velocity spun scaffolds exhibited highly anisotropic mechanical properties closely resembling the native pulmonary heart valve leaflet. Moreover, use of the present fiber-level structural constitutive model allows for the determination of electrospinning conditions to tailor ES-PEUU scaffolds for specific soft tissue applications. The results of this study will help to provide the basis for rationally designed mechanically anisotropic soft tissue engineered implants.

Anisotropy↗

Biaixal stress-stretch behavior of the mitral valve anterior leaflet at physiologic strain rates.

Characterization of the mechanical properties of the native mitral valve leaflets at physiological strain rates is a critical step in improving our understanding of MV function and providing experimental data for dynamic constitutive models. We explored, for the first time, the effects of strain rate (from quasi-static to physiologic) on the biaxial mechanical properties of the native mitral valve anterior leaflet (MVAL). A novel high-speed biaxial testing device was developed, capable of achieving in vitro strain rates reported for the MVAL (Sacks et al., Ann. Biomed. Eng. 30(10):1280-1290, 2002). Porcine MVAL specimens were loaded to physiological load levels with cycle periods of 15, 1, 0.5, 0.1, and 0.05 s. The resulting loading stress-strain responses were found to be remarkably independent of strain rate. The hysteresis, defined as the fraction of the membrane strain energy between the loading and unloading curves tension-areal stretch curves, was low (approximately 12%) and did not vary with strain rate. The results of the present work indicated that MVAL tissues exhibit complete strain rate insensitivity at and below physiological strain rates under physiological loading conditions. These novel results suggest that experimental tests utilizing quasi-static strain rates are appropriate for constitutive model development for mitral valve tissues. The mechanisms underlying this quasi-elastic behavior are as yet unknown, but are likely an important functional aspect of native mitral valve tissues and clearly warrant further study.

Animals↗

In-vivo dynamic deformation of the mitral valve anterior leaflet.

BACKGROUND: Surgical techniques have been developed for mitral valve repair for a wide range of pathologies. However, excessive tissue stress and damage have been identified as etiologic factors limiting long-term durability. Before computational models to optimize valve repair can be realistically developed, in-vivo dynamic mitral valve leaflet strain data are required. However, these data do not presently exist. In the present study, a sheep model and sonomicrometry were used to compute the in-surface Eulerian strain tensor of the anterior leaflet over the cardiac cycle at varying afterloads. METHODS: The anterior leaflet of nine Dorsett sheep (35 kg to 45 kg) was instrumented with nine 1-mm hemispherical piezoelectric transducers in a 15-mm square array. Three-dimensional crystal spatial positions were recorded at 250 Hz over several cardiac cycles, with peak left ventricular pressures varying from 90 mm Hg to 200 mm Hg. The in-surface Eulerian strain tensor was computed from the crystal displacements. RESULTS: The mitral valve anterior leaflet experiences large anisotropic strains and peak strain rates of 400%/s, followed by an absolute cessation of any deformation during systole. Increasing left ventricular pressure also increased the effective leaflet stiffness but not the peak strains. CONCLUSIONS: We report the first data on the dynamic in-vivo strain tensor of a functioning mitral valve anterior leaflet, which indicated large anisotropic strains and very high strain rates. Our observations also suggest that changes in left ventricular pressure and annular geometry result in altered effective leaflet stiffness, and may be an important factor in reducing leaflet stress and as such potentially affect mitral valve repair longevity.

Animals↗

The material properties of the native porcine mitral valve chordae tendineae: an in vitro investigation.

The material properties of the mitral valve chordae tendineae are important for the understanding of leaflet coaptation configuration and chordal pathology. There is limited information about the mechanical properties of the chordae during physiologic loading. Dual camera stereo photogrammetry was used to measure strains of the chordae in vitro under physiologic loading conditions. Two high-speed, high-resolution cameras captured the movement of graphite markers attached to the central section of the chordae. A uniaxial test simulating the same loading conditions was conducted on the same chordae using the same markers. The maximum strain experienced during the cardiac cycle was 4.29% +/- 3.43%. The loading rate was higher at 75.3% +/- 48.6% strain per second than the unloading rate at -54.8% +/- -56.6% strain per second. The anterior lateral strut chordae had a higher maximum strain (5.7% +/- 3.8%) and loading rate (80.5% +/- 51.9% strain per second) than the posterior medial strut chordae (5.5% +/- 2.3% strain and 68.1% +/- 48.3% strain per second). The posterior medial strut chordae had a higher unloading rate (-68.5% +/- -59.1% strain per second) than the anterior lateral strut chordae (-44.9% +/- -57.2% strain per second). Although the anterior lateral and posterior medial strut chordae have a significantly different diameter and length, they experience a similar strain, strain rate, and tension. In conclusion, a non-destructive technique was developed to measure in vitro chordal strain in the mitral valve. This technique allows the investigation of the behavior of biological tissues under physiologic loading conditions.

Animals↗

The effects of aneurysm on the biaxial mechanical behavior of human abdominal aorta.

The biomechanical response of normal and pathologic human abdominal aortic tissue to uniaxial loading conditions is insufficient for the characterization of its three-dimensional (3D) mechanical behavior. Planar biaxial mechanical evaluation allows for 3D constitutive modeling of nearly incompressible tissues, as well as the investigation of the nature of mechanical anisotropy. In the current study, 26 abdominal aortic aneurysm (AAA) tissue samples and 8 age-matched (> 60 years of age) nonaneurysmal abdominal aortic (AA) tissue samples were obtained and tested using a tension-controlled biaxial testing protocol. Graphical response functions (Sun et al., 2003. J. Biomech. Eng. 125, 372-380) were used as a guide to describe the pseudo-elastic response of AA and AAA. Based on the observed pseudo-elastic response, a four-parameter exponential strain energy function developed by Vito (1990. J. Biomech. Eng. 112, 153-159) was used from which both an individual specimen and group material parameter sets were determined for both AA and AAA. Peak Green strain values in the circumferential (Ethetatheta,max) and longitudinal (ELL,max) directions under an equibiaxial tension of 120 N/m were also compared. The strain energy function fit all of the individual specimens well with an average R2 of 0.95 +/- 0.02 and 0.90 +/- 0.02 (mean +/- SEM) for the AA and AAA groups, respectively. The average Ethetatheta,max at 200 N/m equibiaxial tension was found to be significantly smaller for AAAs as compared to AAs (0.07 +/- 0.01 versus 0.13 +/- 0.03, respectively; p < 0.01). There was also a pronounced increase in the circumferential stiffness for AAA tissue as compared to AA tissue, indicating a larger degree of anisotropy for this tissue as compared to age-matched AA tissue. We also observed that the four-parameter Fung-elastic model was not able to fit the AAA tissue mechanical response using physically realistic material parameter values. It was concluded that aneurysmal degeneration of the abdominal aorta is associated with an increase in mechanical anisotropy, with preferential stiffening in the circumferential direction.

Anisotropy↗

A structural model for the flexural mechanics of nonwoven tissue engineering scaffolds.

The development of methods to predict the strength and stiffness of biomaterials used in tissue engineering is critical for load-bearing applications in which the essential functional requirements are primarily mechanical. We previously quantified changes in the effective stiffness (E) of needled nonwoven polyglycolic acid (PGA) and poly-L-lactic acid (PLLA) scaffolds due to tissue formation and scaffold degradation under three-point bending. Toward predicting these changes, we present a structural model for E of a needled nonwoven scaffold in flexure. The model accounted for the number and orientation of fibers within a representative volume element of the scaffold demarcated by the needling process. The spring-like effective stiffness of the curved fibers was calculated using the sinusoidal fiber shapes. Structural and mechanical properties of PGA and PLLA fibers and PGA, PLLA, and 50:50 PGA/PLLA scaffolds were measured and compared with model predictions. To verify the general predictive capability, the predicted dependence of E on fiber diameter was compared with experimental measurements. Needled nonwoven scaffolds were found to exhibit distinct preferred (PD) and cross-preferred (XD) fiber directions, with an E ratio (PD/XD) of approximately 3:1. The good agreement between the predicted and experimental dependence of E on fiber diameter (R2 = 0.987) suggests that the structural model can be used to design scaffolds with E values more similar to native soft tissues. A comparison with previous results for cell-seeded scaffolds (Engelmayr, G. C., Jr., et al., 2005, Biomaterials, 26(2), pp. 175-187) suggests, for the first time, that the primary mechanical effect of collagen deposition is an increase in the number of fiber-fiber bond points yielding effectively stiffer scaffold fibers. This finding indicated that the effects of tissue deposition on needled nonwoven scaffold mechanics do not follow a rule-of-mixtures behavior. These important results underscore the need for structural approaches in modeling the effects of engineered tissue formation on nonwoven scaffolds, and their potential utility in scaffold design.

Biocompatible Materials↗

Dynamic simulation pericardial bioprosthetic heart valve function.

While providing nearly trouble-free function for 10-12 years, current bioprosthetic heart valves (BHV) continue to suffer from limited long-term durability. This is usually a result of leaflet calcification and/or structural degeneration, which may be related to regions of stress concentration associated with complex leaflet deformations. In the current work, a dynamic three-dimensional finite element analysis of a pericardial BHV was performed with a recently developed FE implementation of the generalized nonlinear anisotropic Fung-type elastic constitutive model for pericardial BHV tissues (W. Sun and M.S. Sacks, 2005, [Biomech. Model. Mechanobiol., 4(2-3), pp. 190-199]). The pericardial BHV was subjected to time-varying physiological pressure loading to compute the deformation and stress distribution during the opening phase of the valve function. A dynamic sequence of the displacements revealed that the free edge of the leaflet reached the fully open position earlier and the belly region followed. Asymmetry was observed in the resulting displacement and stress distribution due to the fiber direction and the anisotropic characteristics of the Fung-type elastic constitutive material model. The computed stress distribution indicated relatively high magnitudes near the free edge of the leaflet with local bending deformation and subsequently at the leaflet attachment boundary. The maximum computed von Mises stress during the opening phase was 33.8 kPa. The dynamic analysis indicated that the free edge regions of the leaflets were subjected to significant flexural deformation that may potentially lead to structural degeneration after millions of cycles of valve function. The regions subjected to time varying flexural deformation and high stresses of the present study also correspond to regions of tissue valve calcification and structural failure reported from explanted valves. In addition, the present simulation also demonstrated the importance of including the bending component together with the in-plane material behavior of the leaflets towards physiologically realistic deformation of the leaflets. Dynamic simulations with experimentally determined leaflet material specification can be potentially used to modify the valve towards an optimal design to minimize regions of stress concentration and structural failure.

Animals↗

Fiber kinematics of small intestinal submucosa under biaxial and uniaxial stretch.

Improving our understanding of the design requirements of biologically derived collagenous scaffolds is necessary for their effective use in tissue reconstruction. In the present study, the collagen fiber kinematics of small intestinal submucosa (SIS) was quantified using small angle light scattering (SALS) while the specimen was subjected to prescribed uniaxial or biaxial strain paths. A modified biaxial stretching device based on Billiar and Sacks (J. Biomech., 30, pp. 753-7, 1997) was used, with a real-time analysis of the fiber kinematics made possible due to the natural translucency of SIS. Results indicated that the angular distribution of collagen fibers in specimens subjected to 10% equibiaxial strain was not significantly different from the initial unloaded condition, regardless of the loading path (p=0.31). Both 10% strip biaxial stretch and uniaxial stretches of greater than 5% in the preferred fiber direction led to an increase in the collagen fiber alignment along the same direction, while 10% strip biaxial stretch in the cross preferred fiber direction led to a broadening of the distribution. While an affine deformation model accurately predicted the experimental findings for a biaxial strain state, uniaxial stretch paths were not accurately predicted. Nonaffine structural models will be necessary to fully predict the fiber kinematics under large uniaxial strains in SIS.

Animals↗

The flexural rigidity of the aortic valve leaflet in the commissural region.

Flexure is a major deformation mode of the aortic valve (AV) leaflet, particularly in the commissural region where the upper portion of the leaflet joins the aortic root. However, there are no existing data known on the mechanical properties of leaflet in the commissural region. To address this issue, we quantified the effective stiffness of the commissural region using a cantilever beam method. Ten specimens were prepared, with each specimen flexed in the direction of natural leaflet motion (forward) and against the natural motion (reverse). At a flexure angle (phi) of 30 degrees , the effective forward direction modulus E was 42.63+/-4.44 kPa and the reverse direction E was 75.01+/-14.53 kPa (p=0.049). Further, E-phi response was linear (r(2) approximately 0.9) in both flexural directions. Values for dE/dphi were -2.24+/-0.6 kPa/ degrees and -1.90+/-0.3 kPa/ degrees in the forward and reverse directions, respectively (not statistically different, p=0.424), indicating a consistent decrease in stiffness with increased flexure. In comparison, we have reported that the effective tissue stiffness of AV leaflet belly region was 150-200 kPa [Merryman, W.D., Huang, H.Y.S., Schoen, F.J., Sacks, M.S. (2006). The effects of cellular contraction on AV leaflet flexural stiffness. Journal of Biomechanics 39 (1), 88-96], which was also independent of direction and amount of flexure. Histological studies of the commissure region indicated that tissue buckling was a probable mechanism for decrease in E with increasing flexure. The observed change in E with flexural angle in the commissural region is a subtle aspect of valve function. From a valve design perspective, these findings can be used as design criteria in fabricating prosthetic devices AV resulting in better functional performance.

Animals↗

The role of MMP-I up-regulation in the increased compliance in muscle-derived stem cell-seeded small intestinal submucosa.

We have previously observed that muscle-derived stem cells (MDSC) seeded onto porcine small intestinal submucosa (SIS) increase the mechanical compliance of the engineered tissue construct [Lu SH, Sacks MS, Chung SY, Gloeckner DC, Pruchnic R, Huard J, et al. Biaxial mechanical properties of muscle-derived cell seeded small intestinal submucosa for bladder wall reconstitution. Biomaterials 2005;26(4):443-9]. To date, however, the initial remodeling events which occur when MDSC are seeded onto SIS have yet to be elucidated. One potential mechanism responsible for the observed increase in mechanical compliance is the release of matrix metalloproteinase-I (MMP-I). To investigate this finding, MDSC ( approximately 1x10(6)) were cultured on single-layer SIS cell culture inserts (4.7 cm2) for 1-10 days. MDSC MMP-I activity on SIS in the supernatant at 1, 3, 5, 7, and 10 days was determined using a collagenase assay kit. MMP-I activity of the MDSC/SIS was significantly higher (p<0.0025) after one day in culture compared to specimens collected from subsequent time points and the unseeded control. To further study the initial remodeling events, the impact of MMP-I on mechanical compliance was examined. SIS was incubated with 0.16 U/mL collagenase-I for 3, 4.5, 5, and 24h, then biaxial mechanical testing was performed. After 5h of digestion with collagenase-I, mechanical compliance under 1 MPa peak stress was increased by 7% in the circumferential direction, compared to control SIS. These findings suggest that the release of MMP-I in response to initial seeding on SIS and subsequent breakdown of collagen fibers is the mechanism responsible for an increase in mechanical compliance.

Animals↗

Early molecular-level changes in rat bladder wall tissue following spinal cord injury.

Previously, we demonstrated using a rat model of spinal cord injury (SCI) that bladder wall tissue compliance significantly increased within the first 2 weeks following injury. In order to explore the potential molecular-level mechanisms of this event, the present study quantified molecules pertinent to bladder tissue remodeling and changes in mechanical properties. An initial gene array analysis followed by real-time qPCR revealed that the message levels for tropoelastin and lysyl oxidase were as high as 8-fold in SCI rats compared to normal. Furthermore, both the message and protein levels of TGF-beta1 and IGF-1, known stimulators of elastin synthesis, in SCI rat bladders were significantly higher compared to those of normal rats. Taken together, it can be speculated that functional changes of the bladder associated with SCI induce release of select growth factors, which, in turn, stimulate elastogenesis that lead to alteration of biomechanical properties of the wall tissue.

Adaptation, Physiological↗