Search PubMed⌕ Search

Biomedical subjects

Michael A Navakatikyan

Publications and source records attributed to Michael A Navakatikyan.

3 recordsLinked to original sources

Seizure detection algorithm for neonates based on wave-sequence analysis.

OBJECTIVE: The description and evaluation of the performance of a new real-time seizure detection algorithm in the newborn infant. METHODS: The algorithm includes parallel fragmentation of EEG signal into waves; wave-feature extraction and averaging; elementary, preliminary and final detection. The algorithm detects EEG waves with heightened regularity, using wave intervals, amplitudes and shapes. The performance of the algorithm was assessed with the use of event-based and liberal and conservative time-based approaches and compared with the performance of Gotman's and Liu's algorithms. RESULTS: The algorithm was assessed on multi-channel EEG records of 55 neonates including 17 with seizures. The algorithm showed sensitivities ranging 83-95% with positive predictive values (PPV) 48-77%. There were 2.0 false positive detections per hour. In comparison, Gotman's algorithm (with 30s gap-closing procedure) displayed sensitivities of 45-88% and PPV 29-56%; with 7.4 false positives per hour and Liu's algorithm displayed sensitivities of 96-99%, and PPV 10-25%; with 15.7 false positives per hour. CONCLUSIONS: The wave-sequence analysis based algorithm displayed higher sensitivity, higher PPV and a substantially lower level of false positives than two previously published algorithms. SIGNIFICANCE: The proposed algorithm provides a basis for major improvements in neonatal seizure detection and monitoring.

Algorithms↗

A real-time algorithm for the quantification of blood pressure waveforms.

A real-time algorithm for quantification of biological oscillatory signals, such as arterial blood pressure (BP) is proposed which does not require user intervention and works on waveforms complicated by rapid changes in the mean level, frequency, or by the presence of arrhythmia. The algorithm is based on the continous independent assessment of the refractory period (RP). In the first stage, a sample of the signal is band-pass filtered. During the next stage: 1) the local maxima in the filtered signal are identified and their pulse amplitudes (PA) measured on the side opposite to the possible notch position and 2) those maxima whose PA exceeds some threshold are selected and an array of RP values is formed as a fraction of the moving estimate of the interval between successive selected peaks. Finally, the original signal is analyzed by means of two moving averages (MAs) with short and long averaging time intervals. The true peaks are determined as the maxima between intersections of MAs if the peak-to-peak or the intersection-to-intersection intervals since the previous peak and the previous intersection exceed the RP. The algorithm proved to be superior against three commercially available heartbeat detectors yielding an error rate of 0.09%.

Algorithms↗

Dynamic baroreflex control of blood pressure: influence of the heart vs. peripheral resistance.

The aim in the present experiments was to assess the dynamic baroreflex control of blood pressure, to develop an accurate mathematical model that represented this relationship, and to assess the role of dynamic changes in heart rate and stroke volume in giving rise to components of this response. Patterned electrical stimulation [pseudo-random binary sequence (PRBS)] was applied to the aortic depressor nerve (ADN) to produce changes in blood pressure under open-loop conditions in anesthetized rabbits. The stimulus provided constant power over the frequency range 0-0.5 Hz and revealed that the composite systems represented by the central nervous system, sympathetic activity, and vascular resistance responded as a second-order low-pass filter (corner frequency approximately 0.047 Hz) with a time delay (1.01 s). The gain between ADN and mean arterial pressure was reasonably constant before the corner frequency and then decreased with increasing frequency of stimulus. Although the heart rate was altered in response to the PRBS stimuli, we found that removal of the heart's ability to contribute to blood pressure variability by vagotomy and beta(1)-receptor blockade did not significantly alter the frequency response. We conclude that the contribution of the heart to the dynamic regulation of blood pressure is negligible in the rabbit. The consequences of this finding are examined with respect to low-frequency oscillations in blood pressure.

Animals↗