Search PubMed⌕ Search

Biomedical subjects

Maximilian F Reiser

Publications and source records attributed to Maximilian F Reiser.

At least 37 records · Page 2Linked to original sources

Catheter-based intraluminal optical coherence tomography (OCT) of the ureter: ex-vivo correlation with histology in porcine specimens.

Intraluminal optical coherence tomography (OCT) applies coherent light to provide cross-sectional images with a spatial resolution of 10-25 microm. We compared OCT and matching whole-mount histology microscopy sections of porcine upper ureters ex vivo for visualization and delineation of different tissue layers of the ureteral wall. Porcine ureters (six specimens, 24 quadrants) were flushed with normal saline solution prior to insertion of the OCT catheter (diameter, 0.014 inch, OCT wavelength, 1,300+/-20 nm). Cross-sectional OCT images were obtained in marked locations before specimens were fixed in 4% formalin, cut at marked locations, whole-mounted, and stained with hematoxilin and eosin. Visualization and delineation of different tissue layers of the ureteral wall by OCT was compared with matching histology by two independent observers (O1,O2). OCT distinguished tissue layers of the ureteral wall in all quadrants. In OCT images, O1/O2 delineated urothelium and lamina propria in 23/24 quadrants, lamina propria and muscle layer in 19/16 quadrants, inner and outer muscle layer in 13/0 quadrants, and urothelial cell layers in 13/2 quadrants, respectively. Intraluminal OCT provides histology-like images of the ureter in porcine specimens ex vivo and reliably distinguishes between urothelium and deeper tissue layers of the ureteral wall.

Animals↗

Whole-body MRI and PET-CT in the management of cancer patients.

Mortality rate, prognosis, and treatment outcome of cancer patients depend strongly on the detection of malignancy at an early stage and efficient monitoring of the disease. Multimodality diagnostic approaches are now widely applied for tumor detection, staging, and follow-up. However, the introduction of whole-body imaging modalities into clinical practice has substantially expanded diagnostic options. PET-CT has increased diagnostic accuracy by providing "anatometabolic" information by fusing tumor glucose-uptake measures from the PET examination and accurate delineation of anatomical structures given by spiral CT. Since PET-CT is associated with high doses of ionizing radiation, it is used in mainly tumor staging and screening within the scope of tertiary prevention. Here promising results have been reported for various tumor entities. MRI provides excellent tissue contrast, detailed morphological information and lack of ionizing radiation. MRI has been employed for the assessment of focal pathologies in specific anatomical regions. Whole-body MRI scanners using multiple receiver channels with parallel acquisition techniques now allow tumor screening from head to toe within substantially shorter examination times and without compromises in image resolution. We report our experience with these two novel techniques and discuss their benefits and drawbacks in terms of systemic tumor screening.

Early Diagnosis↗

High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography--initial experience.

The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265+/-25HU and 254+/-16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367+/-36HU versus 402+/-28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68+/-0.08 mm versus 2.81+/-0.07 mm and 3.29+/-0.06 mm versus 3.18+/-0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen.

Animals↗

Cardiac CINE MR imaging with a 32-channel cardiac coil and parallel imaging: impact of acceleration factors on image quality and volumetric accuracy.

PURPOSE: To assess the impact of parallel imaging algorithms on image quality and volumetric accuracy of CINE magnetic resonance imaging (MRI) with high temporal and spatial resolution using a new 32-channel dedicated cardiac phased array coil. MATERIALS AND METHODS: Fourteen individuals underwent steady-state free precession (SSFP) CINE MRI using a 32-element phased-array coil and parallel imaging acceleration using spatiotemporal sensitivity encoding (TSENSE). Acquisition acceleration ranged from R = 2 to 7. In conjunction with data extracted from phantom measurements, contrast-to-noise ratio (CNR) performance was evaluated for each acceleration factor and subjective image quality was evaluated by two independent readers. In addition, volumetric assessment was performed for each acceleration factor based on a single breath-hold multi-slice data acquisition. Results were compared to nonTSENSE measurements. RESULTS: CNR for non-accelerated CINE (R = 1) was 45.7 +/- 12.8 and showed a constant decrease with increase in acceleration of 51% at R = 4 and 86% at R = 7. CNR losses accompanied reductions in subjective image quality. Volumetric evaluation was accurate for R <or= 4, with significant underestimation of ejection fraction (EF) at higher accelerations. CONCLUSION: This study shows that one-dimensional acceleration factors up to R = 4 allow accurate SSFP CINE MRI even though CNR is significantly reduced. This allows for a marked reduction in scan time and allows for multi-slice CINE imaging with high spatial and temporal resolution.

Adult↗

High-resolution renal MRA: comparison of image quality and vessel depiction with different parallel imaging acceleration factors.

PURPOSE: To investigate the image quality and vessel depiction of renal MRA with integrated parallel imaging techniques (iPAT) using acceleration factors of 2 and 3. MATERIALS AND METHODS: In this prospective study renal MRA was performed on 14 and 12 patients with acceleration factors of 3 and 2, respectively. For the MRA a 3D-GRE sequence with an acquired spatial resolution of 0.9 x 0.8 x 1.0 mm(3) was applied (TR/TE = 3.79 msec/1.39 msec, FOV = 400 mm x 320 mm, acquired matrix = 512 x 384, flip angle = 25 degrees) on a 32-channel 1.5T MR scanner. The acquisition time was 26 seconds with iPAT 2, and 19 seconds with iPAT3. All parameters other than acquisition time and acceleration factor were kept constant. To assess the signal-to-noise ratio (SNR) we performed repetitive phantom measurements using iPAT 2 and 3. The images were rated by two radiologists in terms of noise, artifacts, and the quality of vessel depiction for the proximal, segmental, and subsegmental renal artery. A Mann-Whitney U-test and kappa-test were used for statistical analysis. RESULTS: SNR decreased significantly with iPAT 3 in the phantom measurements. The two readers found no difference in noise, but significantly fewer artifacts with iPAT 3. The depiction of segmental vessels was significantly better for both readers with iPAT 3, and the subsegmental vessels were rated significantly better by one reader. iPAT 3 also resulted in a better interreader agreement. CONCLUSION: The use of iPAT 3 for renal MRA enables a better depiction of the distal parts of the renal artery. The decrease in SNR is not diagnostically impairing.

Adult↗

Methods and applications of diffusion imaging of vertebral bone marrow.

Diffusion-weighted imaging (DWI) is an MRI technique that is sensitive to random water movements at spatial scales far below typical MRI voxel dimensions. DWI is a valuable tool for the diagnoses of diseases that involve alterations in water mobility. In the spine, DWI has proven to be a highly useful method for the differential diagnosis of benign and malignant compression fractures. In these pathologies, the microscopic structure of bone marrow is altered in a very different ways, leading to different water mobility, which can be depicted by DWI. Most of the pulse sequences developed for MRI can be adapted for DWI. However, these DWI-adapted sequences are frequently affected by artifacts, mostly caused by physiological motion. Therefore, the introduction of additional correction techniques, or even the development of new sequences is necessary. The first part of this article describes the principles of DWI and the sequences used for DWI of the spine: spin echo (SE), turbo spin echo (TSE), single-shot echo planar imaging (EPI), and steady-state free precession (SSFP) sequences. In the second part, clinical applications of DWI of the spinal bone marrow are extensively discussed.

Bone Diseases↗

Renal perfusion: comparison of saturation-recovery TurboFLASH measurements at 1.5T with saturation-recovery TurboFLASH and time-resolved echo-shared angiographic technique (TREAT) at 3.0T.

PURPOSE: To investigate the dependence of semiquantitative renal perfusion parameters on the acquisition technique and field strength used. MATERIALS AND METHODS: After intravenous injection of 7-mL Gd-chelates, high-temporal-resolution turbo fast low-angle shot (TurboFLASH) renal perfusion measurements were performed on eight healthy volunteers at 1.5T and another eight healthy volunteers at 3.0T. Another eight healthy volunteers were examined at 3.0T using time-resolved echo-shared angiographic technique (TREAT) after bolus administration of 7-mL Gd-chelates with a temporal resolution of 1.4 seconds. Analysis of the first-pass perfusion data yielded the following semiquantitative renal perfusion indices: mean transit time (MTT), time to peak (TTP), maximal upslope (MUS), and maximal signal intensity (MSI). RESULTS: MTT and TTP did not show significant differences between the different techniques. MSI and MUS were significantly (P < or = 0.002) higher with TREAT (591.1 a.u./second and 103.5 a.u./second) than with TurboFLASH at both field strengths (1.5T: 400.5 a.u./second and 65.4 a.u./second; 3.0T: 362.2 a.u./second and 68.7 a.u./second). CONCLUSION: Semiquantitative renal perfusion measurements are feasible with time-resolved echo-shared sequences and TurboFLASH techniques. While MTT and TTP appear to be independent of the technique and field strength applied, MUS and MSI are higher with TREAT.

Adult↗

Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography.

RATIONALE AND OBJECTIVES: Restenosis remains a major limitation of coronary catheter-based stent placement. Therefore, a reliable noninvasive diagnostic method for the evaluation of stented coronary arteries would be highly desirable. Our aim was to evaluate the diagnostic accuracy of high-resolution 64-slice computed tomography (64SCT) in a pilot study for the assessment of the lumen of coronary artery stents. MATERIALS AND METHODS: Twenty-five patients underwent 64SCT of the coronary arteries and quantitative x-ray coronary angiography (QCA) after coronary artery stent placement. 64SCT coronary angiography was performed with the following parameters: spatial resolution = 0.4 x 0.4 x 0.4 mm; temporal resolution = 83-165 milliseconds; contrast agent = 80 mL at a flow rate of 5 mL/second; retrospective electrocardiogram gating. The 64SCT scans were evaluated for image quality and for the presence of significant in-stent and peri-stent (proximal and distal) stenoses. Determinations were made of the sensitivity, specificity, diagnostic accuracy, and positive and negative predictive values (PPV and NPV) of 64SCT for the detection or exclusion of stenoses. RESULTS: A total of 46 stents were evaluated, of which 45 (98%) were of diagnostic image quality. Significant in-stent restenosis or occlusion was detected on QCA in 8/45 cases (>/=50% stenosis = 6; occlusion = 2). The sensitivity, specificity, accuracy, PPV, and NPV of 64SCT for the detection of significant in-stent disease was 75%, 92%, 89%, 67%, and 94%, respectively. Both occluded coronary artery stents were correctly identified. The sensitivity, specificity, and accuracy values of 64SCT for the detection of significant proximal peri-stent stenoses were 75%, 95%, and 93%, respectively, whereas the values for detection of significant distal peri-stent stenoses were 67%, 85%, and 84%, respectively. CONCLUSION: The high spatial and temporal resolution of 64SCT may permit improved assessment of stent occlusion and peri-stent disease, although detection of in-stent stenosis remains difficult.

Adult↗

Diagnostic accuracy of optical coherence tomography and intravascular ultrasound for the detection and characterization of atherosclerotic plaque composition in ex-vivo coronary specimens: a comparison with histology.

BACKGROUND: Both intravascular ultrasound and optical coherence tomography have been purported to accurately detect and characterize coronary atherosclerotic plaque composition. The aim of our study was to directly compare the reproducibility and diagnostic accuracy of optical coherence tomography and intravascular ultrasound for the detection and characterization of coronary plaque composition ex vivo as compared with histology. METHODS AND RESULTS: Intravascular ultrasound (20 MHz) and optical coherence tomography imaging was performed in eight heart specimens using motorized pullback. Standard histology using hematoxylin-eosin and van Gieson staining was performed on 4 mum thick slices. Each slice was divided into quadrants and accurately matched cross-sections were analyzed for the presence of fibrous, lipid-rich, and calcified coronary plaque using standard definitions for both intravascular ultrasound and optical coherence tomography and correlated with histology. After exclusion of 145/468 quadrants, we analyzed the remaining 323 quadrants with excellent image quality in each procedure. Optical coherence tomography demonstrated a sensitivity and specificity of 91/88% for normal wall, 64/88% for fibrous plaque, 77/94% for lipid-rich plaque, and 67/97% for calcified plaque as compared with histology. Intravascular ultrasound demonstrated a sensitivity and specificity of 55/79% for normal wall, 63/59% for fibrous plaque, 10/96% for lipid-rich plaque, and 76/98% for calcified plaque. Both intravascular ultrasound and optical coherence tomography demonstrated excellent intraobserver and interobserver agreement (optical coherence tomography: kappa=0.90, kappa=0.82; intravascular ultrasound: kappa=0.87, kappa=0.86). CONCLUSION: Optical coherence tomography is superior to intravascular ultrasound for the detection and characterization of coronary atherosclerotic plaque composition, specifically for the differentiation of noncalcified, lipid-rich, or fibrous plaque.

Aged↗

Analysis of cardiac function--comparison between 1.5 Tesla and 3.0 Tesla cardiac cine magnetic resonance imaging: preliminary experience.

PURPOSE: We sought to assess the feasibility of magnetic resonance imaging to evaluate cardiac function at 3.0 T compared with 1.5 T. MATERIAL AND METHODS: In a prospective intraindividual comparative study, 12 volunteers (range, 18-54 years), and 2 patients (range, 43-53 years) underwent cardiac cine magnetic resonance at both 3.0 T and 1.5 T. Data were acquired both with a steady-state free precession sequence (SSFP) and a spoiled gradient echo (SGE) sequence. If necessary, a frequency scout was used to correct for off-resonance artifacts. For both SSFP and SGE imaging, 6-mm thick retrospectively EKG-gated short axis views were acquired with equal matrix size (192 x 163) and comparable repetition time (TR). Cardiac function parameters were determined manually by a single investigator. Cardiac function parameters, signal to noise ratio (SNR), contrast to noise ratio (CNR), and the presence of artifacts were compared between the 2 magnetic field strengths. For statistical analysis, a Pearson's correlation coefficient was calculated, and a paired Student t test was used to test statistical significance. RESULTS: Very good correlations between cardiac function parameters at 1.5 T and 3.0 T (r > 0.84, P < 0.0011) were obtained. Compared with SGE, SSFP more frequently was prone to artifacts. With SSFP/SGE at 3.0 T, a SNR gain of 9.4/16% was achieved compared with 1.5 T. CONCLUSION: Functional cardiac cine magnetic resonance imaging can be regarded as equally accurate at 3.0 T compared with 1.5 T. Compared with SSFP imaging, the SGE sequence benefits more from higher field strengths and is less affected by artifacts.

Adolescent↗

Cardiac steady-state free precession CINE magnetic resonance imaging at 3.0 tesla: impact of parallel imaging acceleration on volumetric accuracy and signal parameters.

OBJECTIVES: We sought to evaluate the impact of 3.0 T on accelerated CINE steady-state free precession (SSFP) regarding signal parameters and its volumetric accuracy. MATERIAL AND METHODS: Ten individuals underwent cardiac CINE imaging at 1.5 T and 3.0 T using standard single-slice CINE and multislice TSENSE-accelerated CINE (5 slices/breath-hold) with 4-fold acceleration. Data were evaluated for left ventricular volumetric parameters (EDV, ESV, and EF) as well as for SNR and CNR. Phantom based data allowed for g-factor evaluation for estimation of noise levels for accelerated data sets. Volumetric results and signal parameters were compared with results of single-slice CINE SSFP at 1.5 T as standard of reference (SOR). RESULTS: Single-slice CINE at 3.0 T showed a approximately 90% increase in CNR compared with the SOR (P < 0.001). At 3.0 T, TSENSE CINE showed a less pronounced estimated loss in CNR (-58 +/- 6%) compared with single-slice CINE than at 1.5 T (-71 +/- 2%). 3.0 T TSENSE CINE showed a 21 +/- 18% lower CNR than the nonaccelerated 1.5 T CINE (P < 0.05). EF results for all data sets did not show any significant error while for EDV some errors have been encountered. CONCLUSION: 3.0 T permits compensation for the high CNR loss, which accompanies the 4-fold TSENSE acceleration at 1.5 T and shows volumetric accuracy. The use of parallel imaging may help to alleviate SAR limitations at higher field strength.

Adult↗

Quantitative assessment of patellar cartilage volume and thickness at 3.0 tesla comparing a 3D-fast low angle shot versus a 3D-true fast imaging with steady-state precession sequence for reproducibility.

OBJECTIVES: We sought to compare patellar cartilage volume and thickness measurement between 3D-FLASH and 3D-True fast imaging with steady-state precession (FISP) image data at 3.0 T. MATERIALS AND METHODS: One knee each of 6 healthy adults was examined by axial magnetic resonance imaging (MRI) performed with a 3D-fast flow angle shot (FLASH) water-excitation sequence and a 3D-TrueFISP water-excitation sequence (spatial resolution 0.31 x 0.31 x 1.5 mm3). Patellar cartilage volume and mean/maximum thickness were calculated. Intraindividual/average reproducibility and interindividual variability were determined from 3 consecutive data sets acquired for each volunteer and sequence. RESULTS: Patellar cartilage volume and thickness as well as reproducibility was slightly but not significantly lower for the 3D-TrueFISP data than for the 3D-FLASH data (volume: 3.4-6.3 mL (3D-FLASH)/3.1-6.0 mL (3D-TrueFISP), average reproducibility 1.8% (3D-FLASH)/4.4% (3D-TrueFISP); mean thickness: 2.1-2.8 mm (3D-FLASH)/1.9-2.6 mm (3D-TrueFISP), average reproducibility 2.8% (3D-FLASH)/3.8% (3D-TrueFISP); maximum thickness: 4.7-6.6 mm (3D-FLASH)/4.5-6.2 mm (3D-TrueFISP), average reproducibility 2.6% (3D-FLASH)/4.1% (3D-TrueFISP)). Interindividual variability was comparable for both sequence techniques. CONCLUSION: At 3.0 T, the 3D-FLASH sequence showed tendency to be slightly superior to the 3D-TrueFISP sequence considering robust and valid assessment of quantitative cartilage parameters in young healthy adults, although there was found no significant statistical difference between both imaging techniques. However, in patients suffering from osteoarthritis (OA), the 3D-TrueFISP sequence might prove advantageous for monitoring of disease progression and evaluation of therapy success, particularly because the substantially higher signal to noise ratio/contrast to noise ratio values might allow for higher spatial resolution and hence for improvement of the accuracy of segmentation process especially at the articular surface.

Adult↗

Phase-sensitive inversion recovery (PSIR) single-shot TrueFISP for assessment of myocardial infarction at 3 tesla.

PURPOSE: The aim of the current study was to show if contrast-to-noise ratio (CNR) could be improved without loss of diagnostic accuracy if a phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence is used at 3.0 T instead of 1.5 T. MATERIAL AND METHODS: Ten patients with myocardial infarction were examined on a 1.5 T magnetic resonance (MR) system (Avanto, Siemens Medical Systems) and at a 3.0 T MR system. Imaging delayed contrast enhancement was started 10 minutes after application of contrast material. A phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence was used at 1.5 and 3.0 T and compared with a segmented IR turboFLASH sequence at 1.5 T, which served as the reference method. Infarct volumes and CNR of infarction and normal myocardium were compared with the reference method. RESULTS: The PSIR Single-Shot TrueFISP technique allows for imaging nine slices during a single breathhold without adaptation of the inversion time. The mean value of CNR between infarction and normal myocardium was 5.9 at 1.5 T and 12.2 at 3.0 T (magnitude images). The CNR mean value of the reference method was 8.4. The CNR mean value at 3.0 T was significantly (P = 0.03) higher than the mean value of the reference method. The correlation coefficients of the infarct volumes, determined with the PSIR single-shot TrueFISP technique at 1.5 T and at 3.0 T and compared with the reference method, were r = 0.96 (P = 0.001) and r = 0.99 (P = 0.0001). CONCLUSION: The use of PSIR single-shot TrueFISP at 3.0 T allows for accurate detection and assessment of myocardial infarction. CNR is significantly higher at 3.0 T compared with 1.5 T. The PSIR single-shot technique at 3.0 T provides a higher CNR than the segmented reference technique at 1.5 T.

Adult↗

Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

OBJECTIVES: We sought to evaluate the impact of patients' heart rate (HR) on coronary CTA image quality (IQ) and motion artifacts using a 64-slice scanner with 0.33/360 degrees rotation. MATERIALS AND METHODS: Coronary CTA data sets of 32 patients (HR 65 bpm to 75 bpm, n = 7) examined on a 64-slice scanner (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) with 0.33s/360 degrees gantry rotation speed were analyzed. All patients had suspicion of coronary artery disease. Data acquisition was performed using 64 x 0.6-mm collimation, and contrast enhancement was provided by injection of 80 mL of iopromide (5 mL/s + NaCl). Images were reconstructed throughout the RR interval using half-scan and dual-segment reconstruction. IQ was rated by 2 observers using a 3-point scale from excellent (1) to nondiagnostic (3) for coronary segments. Quality was correlated to the HR, time point of optimal IQ analyzed, and the benefit of dual-segment reconstruction evaluated. RESULTS: Overall mean IQ was 1.31 +/- 0.32 for all HR, with IQ being 1.08 +/- 0.12 for HR 65 bpm 75 bpm (P = 0.0003). Dual-segment reconstruction did not significantly improve IQ in any HR group (P = NS). Mean IQ was significantly better for LAD than for RCA (P < 0.0001) and LCX (P < 0.01). A total of 3.5% (11/318) of coronary artery segments were rated nondiagnostic by at least one reader based on motion artifacts. Although in HR < 65 bpm, the best IQ was predominately in diastole (93%), in HR > 75 bpm, the best IQ shifted to systole in most cases (86%). CONCLUSIONS: Temporal resolution at 0.33-second rotation allows for diagnostic IQ within a wide range of HR using half-scan reconstruction. With increasing HR the time point of best IQ shifts from mid-diastole to systole.

Adult↗

Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter.

OBJECTIVES: The aims of our study were to compare contrast injection protocols with contrast media containing 300 and 400 mg iodine per milliliter for optimal contrast enhancement in cardiac multidector row computed tomography (CT) and to evaluate the correlation of test bolus curve parameters with the final contrast density of the main bolus. MATERIALS AND METHODS: Sixty patients with known or suspected coronary artery disease were included in a prospective double-blind study. Patients were randomized to 2 groups. Group 1 received 83 mL of a contrast medium (CM) containing 300 mg of iodine (Iomeron 300, Bracco Imaging SpA, Milan, Italy) at a flow rate of 3.3 mL/s, whereas group 2 received 63 mL of the same agent containing 400 mg of iodine (Iomeron 400) at a flow rate of 2.5 mL/s. The test bolus volumes were 20 mL and 15 mL, respectively. Imaging was performed using a 16-slice CT system (16DCT; Somatom Sensation 16, Siemens Medical Solutions, Forchheim, Germany). Contrast densities (Hounsfield Units [HU]) were determined in the cardiac chambers and in the main coronary arteries. The peak density and area under the curve of the test bolus were calculated for each patient. RESULTS: The mean contrast densities of the coronary arteries were 259.1 +/- 46.7 HU for group 1 and 251.6 +/- 51.0 HU, for group 2. No noteworthy differences between groups were noted for density measurements in the cardiac chambers or for the ratio of right-to-left ventricle density. Whereas a positive correlation was noted for both groups between the area under the curve of the test bolus and the mean density of the main bolus, a positive correlation between peak density of the test bolus and mean density of the main bolus was noted only for group 1. CONCLUSION: Equivalent homogenous enhancement of the ventricular cavities and coronary arteries to that obtained using a CM with standard iodine concentration (Iomeron 300) can be achieved with lower overall volumes of administered CM and reduced injection flow rates when a CM with high iodine concentration (Iomeron 400) is used.

Adult↗

Brain magnetic resonance imaging at 3 Tesla using BLADE compared with standard rectilinear data sampling.

OBJECTIVES: We sought to evaluate Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER; BLADE) data acquisition in comparison with standard k-space sampling techniques for axial and sagittal brain imaging at 3 T regarding imaging artifacts. MATERIAL AND METHODS: Forty patients who gave consent were included in a prospective comparison of standard and PROPELLER (BLADE) k-space sampling techniques. All examinations were performed at 3 T with comparison of standard T2-weighted fluid-attenuated inversion recovery (FLAIR) to PROPELLER T2-weighted FLAIR in the axial image orientation and standard T1-weighted gradient echo to PROPELLER T1-weighted FLAIR in the sagittal image orientation. Imaging protocols were matched for spatial resolution, with data evaluation performed by 2 experienced neuroradiologists. Image data were compared regarding various image artifacts and overall image quality. Reader agreement was assessed by Cohen's kappa statistics. RESULTS: PROPELLER T2-weighted axial data acquisition showed significantly less pulsation and Gibb's artifacts than the standard T2-weighted scan. Even without motion correction, the frequency of ghosting (motion) artifacts was substantially lower in the PROPELLER T2-weighted data and readers concordantly (kappa = 1) rated PROPELLER as better than or equal to the standard T2-weighted scan in the majority of cases (95%; P < 0.0001). In the comparison of sagittal T1-weighted data sets, readers showed only fair agreement (kappa = 0.24) and noted consistent wrap artifacts in PROPELLER T1-weighted FLAIR. CONCLUSION: PROPELLER (BLADE) brain magnetic resonance imaging is also applicable at 3 T. In addition to minimizing motion artifacts, the PROPELLER acquisition scheme reduces other magnetic resonance artifacts that would otherwise degrade scan quality.

Adult↗