Search PubMed⌕ Search

Biomedical subjects

Maximilian F Reiser

Publications and source records attributed to Maximilian F Reiser.

At least 19 recordsLinked to original sources

Thioguanin-induced nodular regenerative hyperplasia of the liver-ROC analysis of different MR techniques.

The aim of this study was to evaluate the diagnostic value of different magnetic resonance (MR) techniques for the diagnosis of nodular regenerative hyperplasia (NRH). Thirty-one patients with inflammatory bowel disease, who received 6-thioguanin, underwent liver biopsy and liver MRI on a 1.5-T MR system, with gadolinium and superparamagnetic iron oxide particles (SPIO). MR imaging (MRI) was evaluated independently as well as in consensus by two blinded readers, who received the following image sets: pre-contrast; pre-contrast and gadolinium-enhanced; pre-contrast and SPIO-enhanced and all images. The results were correlated with histopathology and diagnostic efficacy parameters were calculated. NRH was found in 13/31 patients. The set "all images" showed the highest sensitivity (84.6%), accuracy (77.4%) and negative predictive value (86.7%). However, results for gadolinium were only slightly inferior. The highest specificity (76.5%) was found for SPIO. The A(z) values of both readers were highest for gadolinium (mean A(z) = 0.824). It can be concluded that gadolinium-enhanced and SPIO-enhanced MRI enable an accurate diagnosis of NRH. Since gadolinium-enhanced MRI is very sensitive, it should be used for screening high-risk patients. SPIO-enhanced MRI is less sensitive, but more specific. The combination of both guarantees a high sensitivity and specificity and, therefore, is the diagnostic procedure of choice.

Adult↗

ECG-gated 64-MDCT angiography in the differential diagnosis of acute chest pain.

OBJECTIVE: The most important differential diagnoses of acute chest pain include myocardial infarction, aortic dissection, and pulmonary embolism. The purpose of this study was to evaluate the diagnostic value of an ECG-gated 64-MDCT angiography protocol for simultaneous assessment of the pulmonary arteries, coronary arteries, and aorta within a single breath-hold. SUBJECTS AND METHODS: In 55 patients with acute chest pain, ECG-gated CT angiography was performed with a CT system in which 64 slices per gantry rotation were acquired. Density measurement and visual assessment of motion artifacts were performed to evaluate image quality. CT findings were correlated with results of laboratory tests and clinical follow-up. For 20 patients, two independent blinded reviewers compared findings on CT angiography with those on X-ray coronary angiography. RESULTS: Adequate contrast enhancement of the pulmonary vessels, coronary arteries, and aorta was achieved in all cases. Regarding image quality of the coronary arteries, there was minor blurring in seven patients, and in one examination the images did not provide enough information for diagnosis. The average image quality rating was 1.2 on a scale in which 1 indicated no artifacts; 2, minor motion artifacts; and 3, image insufficient for diagnosis. The cause of chest pain was correctly identified with MDCT in 37 patients. The diagnoses included pulmonary embolism (n = 10), coronary stenosis (n = 9), and aortic dissection (n = 1). In four patients, additional diagnoses were found with other examinations. CONCLUSION: With current techniques, ECG-gated CT angiography of the entire chest has very good image quality. The protocol proved helpful in the differential diagnosis of acute chest pain.

Acute Disease↗

Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography.

The aim of this study was to assess the performance of a software tool for quantitative coronary artery analysis of computed tomography coronary angiography (CT-QCA) in comparison with invasive coronary angiography with quantitative analysis (CAG-QCA) as standard of reference. Two radiologists reviewed the CT angiography data sets (Siemens Sensation 64) of 25 patients, grading coronary artery stenoses visually and with a software tool (Circulation, Siemens). Twenty-three data sets with sufficient image quality were included in the final analysis. CAG revealed a total of 30 wall irregularities and 28 stenoses, of which 17 were graded as moderate and nine as hemodynamically significant. CT-QCA showed a better agreement to CAG-QCA, with a systematic overestimation of the degree of stenosis of 6.1% and limits of agreement of +36.1% and -23.9; the correlation coefficient was 0.82 (p < 0.0001). Using CT-QCA, sensitivity, specificity, and positive and negative predictive value were 89%, 100%, 89%, and 100%, respectively, for significant area stenoses greater than 75%. The positive predictive value for the visual assessment amounted to 53%. Interobserver variability between CT-QCA and visual assessment showed a kappa value of 0.72. In conclusion, software-supported CT-QCA makes it possible to quantify significant coronary artery stenoses automatically, with good agreement to CAG-QCA.

Contrast Media↗

Multivariate network analysis of fiber tract integrity in Alzheimer's disease.

Axonal and dendritic integrity is affected early in Alzheimer's disease (AD). Studies using region of interest or voxel-based analysis of diffusion tensor imaging data found significant decline of fractional anisotropy, a marker of fiber tract integrity, in selected white matter areas. We applied a multivariate network analysis based on principal component analysis to fractional anisotropy maps derived from diffusion-weighted scans from 15 AD patients, and 14 elderly healthy controls. Fractional anisotropy maps were obtained from an EPI diffusion sequence using parallel imaging to reduce distortion artifacts. We used high-dimensional image warping to control for partial volume effects due to white matter atrophy in AD. We found a significant regional pattern of fiber changes (p < 0.01) indicating that the integrity of intracortical projecting fiber tracts (including corpus callosum, cingulum and fornix, and frontal, temporal and occipital lobe white matter areas) was reduced, whereas extracortical projecting fiber tracts, including the pyramidal and extrapyramidal systems and somatosensory projections, were relatively preserved in AD. Effects of a univariate analysis were almost entirely contained within the multivariate effect. Our findings illustrate the use of a multivariate approach to fractional anisotropy data that takes advantage of the highly organized structure of anisotropy maps, and is independent of multiple comparison correction and partial volume effects. In agreement with post-mortem evidence, our study demonstrates dissociation between intracortical and extracortical projecting fiber systems in AD in the living human brain.

Aged↗

Fiber connections between the cerebral cortex and the corpus callosum in Alzheimer's disease: a diffusion tensor imaging and voxel-based morphometry study.

Regional cortical atrophy in Alzheimer's disease (AD) most likely reflects the loss of cortical neurons. Several diffusion tensor imaging studies reported reduced fractional anisotropy (FA) in the corpus callosum in AD. The aim of this study was to investigate the association between reduced FA in the corpus callosum and gray matter atrophy in AD. Thirteen patients with AD with a mean (+/-standard deviation) age of 68.3 years (+/-11.5) and mean Mini Mental State Examination (MMSE) score of 21.8 (+/-4.8) were recruited. There were 13 control subjects with a mean age of 66.7 years (+/-6.4) and MMSE of 29.1 (+/-0.7). We used voxel-based morphometry of gray matter maps and region of interest-based analysis of FA in the corpus callosum. FA values of the anterior corpus callosum in AD patients were significantly correlated with gray matter volume in the prefrontal cortex and left parietal lobes. FA values of the posterior corpus callosum were significantly correlated with gray matter volume in the bilateral frontal, temporal, right parietal, and occipital lobes. In control subjects, no correlations were detected. Our findings suggest that decline of FA in the corpus callosum may be related to neuronal degeneration in corresponding cortical areas.

Aged↗

Multislice computed tomography for determination of coronary artery disease in a symptomatic patient population.

BACKGROUND: Multislice computed tomography (MSCT) has started to replace Electron beam CT for quantitation of coronary artery calcium. However no study has evaluated the diagnostic accuracy of MSCT for prediction of coronary artery disease (CAD) in a symptomatic patient population using the volume score. METHODS AND RESULTS: 1347 symptomatic subjects (male = 803, mean age = 62 years) with suspected CAD underwent MSCT studies 1 +/- 2 days before the coronary angiogram. The Agatston (ACS) and Volumetric calcium score (VCS) were calculated using a proprietary workstation. Statistical analyses included the Pearson's correlation coefficient and the nonparametric Mann-Whitney U-test to compare the calcium score in different age groups and between men and women. Sensitivity, specificity and predictive accuracy were calculated for different calcium thresholds for prediction of CAD. ROC curve analyses were used to establish relations between the coronary calcium score and presence or absence of CAD. In 720 (53%) subjects (male = 419) angiography revealed a minimal lumen diameter stenosis greater than 50%. Patients with significant CAD had significantly higher total calcium score values than patients without CAD (P = 0.001). ACS and VCS demonstrate a close correlation for the whole study group, r = 0.99. The overall sensitivity of any calcium to predict stenosis was 99%, specificity = 32%. Exclusion of calcium was highly accurate for exclusion of CAD in subjects older than 50 years (predictive accuracy = 98%). An absolute cutoff >100 and an age and sex specific threshold (score over 75th percentile) were identified as the cutoff levels with the highest sensitivities (86-89%) and lowest false positive rates (20-22%). ROC analyses revealed MSCT calcium scanning as a good clinical test which can be performed with similar accuracy in all age groups with an area under the curve of 0.84. CONCLUSION: Determination of coronary calcium with MSCT is an accurate imaging modality for prediction of significant CAD in a patient population with intermediate likelihood of CAD. Exclusion of any calcium provided strong evidence that patients older than 50 years did not have obstructive CAD. ACS and VCS show an equivalent diagnostic accuracy.

Area Under Curve↗

Functional renal MR imaging: an overview.

Due to its complementary information to standard morphological imaging, functional renal magnetic resonance imaging is a rapid growing field of radiology. This pictorial essay provides a comprehensive overview of state-of-the-art functional renal imaging techniques including renal magnetic resonance angiography, first pass renal perfusion, assessment of renal function, blood-oxygen level dependent imaging of the kidneys and diffusion-weighted imaging of the kidneys including diffusion-tensor imaging of the kidneys. Basic technical concepts for all sequences are laid out. As renal perfusion imaging becomes a clinical routine examination, particular attention is given to renal perfusion measurements and the potential postprocessing approaches. Advantages and drawbacks of the published methods are illustrated. Future applications of functional renal imaging are presented.

Contrast Media↗

Material differentiation by dual energy CT: initial experience.

The aim of this study was to assess the feasibility of a differentiation of iodine from other materials and of different body tissues using dual energy CT. Ten patients were scanned on a SOMATOM Definition Dual Source CT (DSCT; Siemens, Forchheim, Germany) system in dual energy mode at tube voltages of 140 and 80 kVp and a ratio of 1:3 between tube currents. Weighted CT Dose Index ranged between 7 and 8 mGy, remaining markedly below reference dose values for the respective body regions. Image post-processing with three-material decomposition was applied to differentiate iodine or collagen from other tissue. The results showed that a differentiation and depiction of contrast material distribution is possible in the brain, the lung, the liver and the kidneys with or without the underlying tissue of the organ. In angiographies, bone structures can be removed from the dataset to ease the evaluation of the vessels. The differentiation of collagen makes it possible to depict tendons and ligaments. Dual energy CT offers a more specific tissue characterization in CT and can improve the assessment of vascular disease. Further studies are required to draw conclusions on the diagnostic value of the individual applications.

Algorithms↗

Mid-term results in otherwise treatment refractory primary or secondary liver confined tumours treated with selective internal radiation therapy (SIRT) using (90)Yttrium resin-microspheres.

The purpose was to determine the response and survival and to analyse the feasibility of single-session, whole-liver SIRT in patients with non-resectable, otherwise non-responding liver cancer. Thirty-nine patients qualified for SIRT. Eighteen patients suffered from colorectal-cancer metastases (CRC), breast-cancer metastases (MBC, 7), HCC (5) and other tumours (9). Response was assessed by tumour-markers and CT-imaging. At 2-4, 5-7 and 8-9 months follow-up in 3/17, 5/15 and 5/10 of CRC-patients CEA-levels were higher than before. In the MBC group 1-3 and 4-6 months after SIRT tumour-marker-levels were higher in 2/6 and 3/3 patients, respectively. In all HCC-patients AFP-levels dropped 1-3 months after SIRT. Using RECIST, in the CRC-group progressive liver disease (PD) was found in 4/17, 2/12, 2/10 and 2/5 patients at 2-4, 5-8, 9-10 and 12-14 months follow-up. Concerning MBC, after 3 months 7/7 patients presented with stable-disease (SD) or partial-response (PR). At 5-6 months, 1/5 patients showed PD. All HCC-patients showed SD/PR at 2-3 months with no PD at 5-8 months. In the mixed-group 5/6 patients presented with SD/PR at 3-4 months and with SD in 2/3 patients at 5-6 months. The median time-to-PD was 6.5, 8.5 and 8 months for the CRC-, MBC- and mixed-group, respectively. SIRT is a promising, liver-targeted approach for patients with otherwise treatment-refractory liver tumours.

Brachytherapy↗

Effects of injection rate and dose on image quality in time-resolved magnetic resonance angiography (MRA) by using 1.0M contrast agents.

In time-resolved MRA (TR MRA), injection parameters and contrast agent (CA) dose are important factors influencing image quality. In this study, three different injection schemes with different CA volumes were evaluated in 12 healthy volunteers. Injection rates between 0.2 and 0.8 ml/s were evaluated with CA volumes of 10 and 20 ml. To measure circulatory parameters, cine cardiac MRI was performed before each exam. Spatial resolution could be reduced to 2 x 1.4 x 2 mm3, temporal resolution was 2.25 s/frame. To exclude signal saturation at high CA concentrations, a phantom with fixed CA concentrations was placed in the field of view. SNR was measured, and the area under the curve of the arterial signal of the different injection schemes was calculated. Results showed the largest diagnostic window at a relatively slow injection rate of 0.4 ml/s and a CA volume of 10 ml. Circulatory parameters have an important impact on CA arrival, so delay times have to be set depending on these parameters.

Adult↗

Assessment of colonic transit time using MRI: a feasibility study.

The aim of this pilot study was to evaluate a new, non-invasive examination method using MRI for the quantification of the colonic transit time after oral administration of gadolinium-saline solution filled capsules. Healthy volunteers without previous or acute symptoms of gastrointestinal disorders were enrolled. After a 3-day diet for the standardization of gastrocolonic content the volunteers swallowed five Gd-DTPA/saline 0.9%-filled capsules. Seven different concentrations of Gd-DTPA/saline 0.9% solution between 1:0 and 0:1 were tested in a dilution series. Following ingestion of capsules, coronal Flash T1 and True Fisp sequences using a 1.5 Tesla system were obtained at 0 h, 3 h, 6 h, 12 h, 24 h, 36 h and 60 h. Sequences were analyzed by two independent experts for locating the capsules. Overall colonic transit time was separately analyzed for both genders. Fifteen healthy volunteers (7 females, 8 males; mean age 34+/-13 years) were enrolled. The phantom study provided the best contrast in both the T1-and T2-weighted sequences defining a ratio of 1:10 for Gd-DTPA/saline 0.9% solution. The mean transit time accounted for 41+/-9 h in women and for 31+/-10 h in men. MRI is an adequate method for the assessment of colonic transit time offering the advantages of no exposure to radiation, short examination time, possible dynamic evaluation of the transit and the practicability in terms of a future adoption to clinical routine.

Administration, Oral↗

Pulmonary abnormalities in immunocompromised patients: comparative detection with parallel acquisition MR imaging and thin-section helical CT.

PURPOSE: To compare parallel acquisition magnetic resonance (MR) imaging with thin-section helical computed tomography (CT) for depiction of pulmonary abnormalities suggestive of pneumonia in immunocompromised patients. MATERIALS AND METHODS: The institutional review board approved this study; prior consent was obtained. Thirty consecutive neutropenic patients (10 women, 20 men; mean age, 51 years +/- 15 [standard deviation]; range, 25-75 years) with fever of unknown origin or clinical signs and symptoms of lung infection were examined with breath-hold single-shot half-Fourier turbo spin-echo MR imaging. To reduce image blurring and increase MR signal in the lungs, the echo time was shortened with generalized autocalibrating partially parallel acquisition (GRAPPA). Patients underwent thoracic CT (four detector rows and 1-mm section thickness [4 x 1 mm]; pitch, 6) as reference standard. Pulmonary abnormalities (ill-defined nodules, ground-glass opacity areas, and consolidation), their location and distribution, and lesion characteristics were analyzed at MR imaging by three readers, blinded to results of CT, in consensus. Frequencies were calculated for each feature; paired Wilcoxon rank sum test was used to examine whether differences between CT and MR imaging features were statistically significant (alpha < .05). Bonferroni adjustments were performed. Overall sensitivity, specificity, and positive and negative predictive values were determined. RESULTS: Twenty-two patients had pulmonary abnormalities at CT. In 21 (95%) patients, pneumonia was correctly diagnosed with MR imaging. One false-negative finding occurred in a patient with ill-defined nodules smaller than 1 cm at CT. One false-positive finding with MR imaging was the result of blurring and respiratory artifacts (sensitivity, 95%; specificity, 88%; positive predictive value, 95%; negative predictive value, 88%). There was no significant difference in lesion location and distribution. CONCLUSION: With parallel imaging (GRAPPA technique) and fast MR imaging, detection of pulmonary abnormalities is almost as good as with CT. MR imaging has a slight disadvantage in its lower capability to assist in characterization of specific internal features, such as cavitations.

Adult↗

High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: initial experience.

The purpose of this study was to prospectively evaluate the diagnostic accuracy of reader detection of 75% or greater stenosis at high-spatial-resolution multistation magnetic resonance (MR) angiography performed with matrix coils and a blood pool contrast agent. Ten healthy volunteers and 10 patients were examined. All participants provided informed consent to participate in this institutional review board-approved study. For contrast agent-enhanced multistation MR angiography, an albumin-binding gadolinium chelate, gadofosveset trisodium, was used. Imaging was performed during the first-pass and steady-state phases of the contrast agent. Vessel conspicuity on the first-pass MR angiograms obtained in both volunteers and patients was rated as excellent for 93% of vessels. At steady-state imaging, vessel conspicuity was rated as excellent or good for 89% of vessels. Gadofosveset trisodium-enhanced MR angiography yielded sensitivities of 100% and 97% and specificities of 96% and 97% for detection of significant disease in the carotid and lower extremity arteries, respectively.

Adult↗

Screening for bone metastases: whole-body MRI using a 32-channel system versus dual-modality PET-CT.

The diagnostic accuracy of screening for bone metastases was evaluated using whole-body magnetic resonance imaging (WB-MRI) compared with combined fluorodeoxyglucose (FDG) positron emission tomography (PET) and computed tomography (CT) (FDG-PET-CT). In a prospective, blinded study, 30 consecutive patients (18 female, 12 male; 24-76 years) with different oncological diseases and suspected skeletal metastases underwent FDG-PET-CT as well as WB-MRI with the use of parallel imaging (PAT). With a 32-channel scanner, coronal imaging of the entire body and sagittal imaging of the complete spine was performed using T1-weighted and short tau inversion recovery (STIR) sequences in combination. PET-CT was conducted using a low-dose CT for attenuation correction, a PET-emission scan and diagnostic contrast-enhanced CT scan covering the thorax, abdomen and pelvis. Two radiologists read the MRI scans, another radiologist in combination with a nuclear medicine physician read the PET-CT scans, each in consensus. The standard of reference was constituted by radiological follow-up within at least 6 months. In 28 patients, 102 malignant and 25 benign bone lesions were detected and confirmed. WB-MRI showed a sensitivity of 94% (96/102), PET-CT exams achieved 78% (79/102; P<0.001). Specificities were 76% (19/25) for WB-MRI and 80% (20/25) for PET-CT (P>0.05). Diagnostic accuracy was 91% (115/127) and 78% (99/127; P<0.001), respectively. Cut-off size for the detection of malignant bone lesions was 2 mm for WB-MRI and 5 mm for PET-CT. WB-MRI revealed ten additional bone metastases due to the larger field of view. In conclusion, WB-MRI and FDG-PET-CT are robust imaging modalities for a systemic screening for metastatic bone disease. PAT allows WB-MRI bone marrow screening at high spatial resolution and with a diagnostic accuracy superior to PET-CT.

Adult↗

MRA of abdominal vessels: technical advances.

Magnetic resonance angiography (MRA) in general and MRA of the abdominal vessels in particular have undergone substantial improvements in the past 5 years triggered by the introduction and application of parallel imaging (PI), new sequence techniques such as centric k-space trajectories and undersampling, dedicated contrast agents and clinical high-field scanners. All of these techniques have the potential to improve image quality and resolution or decrease the image acquisition time. However, each of them has its own specific advantages and drawbacks. This review describes the main technical innovations and focuses on the impact these developments may have on abdominal MRA. Special consideration is given to the interaction of these various technical advances. The clinical value of advanced MRA techniques is discussed and illustrated by characteristic cases.

Abdomen↗

Dual-source CT cardiac imaging: initial experience.

The relation of heart rate and image quality in the depiction of coronary arteries, heart valves and myocardium was assessed on a dual-source computed tomography system (DSCT). Coronary CT angiography was performed on a DSCT (Somatom Definition, Siemens) with high concentration contrast media (Iopromide, Ultravist 370, Schering) in 24 patients with heart rates between 44 and 92 beats per minute. Images were reconstructed over the whole cardiac cycle in 10% steps. Two readers independently assessed the image quality with regard to the diagnostic evaluation of right and left coronary artery, heart valves and left ventricular myocardium for the assessment of vessel wall changes, coronary stenoses, valve morphology and function and ventricular function on a three point grading scale. The image quality ratings at the optimal reconstruction interval were 1.24+/-0.42 for the right and 1.09+/-0.27 for the left coronary artery. A reconstruction of diagnostic systolic and diastolic images is possible for a wide range of heart rates, allowing also a functional evaluation of valves and myocardium. Dual-source CT offers very robust diagnostic image quality in a wide range of heart rates. The high temporal resolution now also makes a functional evaluation of the heart valves and myocardium possible.

Algorithms↗

Dual breath-hold magnetic resonance cine evaluation of global and regional cardiac function.

The purpose of our study was to evaluate the accuracy of a multislice cine magnetic resonance imaging (MRI) technique with parallel imaging in regard to global and regional left ventricular function. Forty-two individuals underwent cine MRI on a 1.5-tesla scanner. Cine MRI used a steady-state free precession technique and was performed as a single-slice technique (nonTSENSE cine) and an accelerated multislice technique (TSENSE cine) with five slices per breath-hold. End diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) were evaluated for all data sets and in regard to regional wall motion and regional wall motion analysis, and quantitative regional wall thickness and systolic thickening were also assessed. EDV, ESV, and EF based on TSENSE cine showed excellent correlation to the nonTSENSE cine approach (all r(2)=0.99, P<0.001). While EDV evaluations showed a small underestimation for TSENSE cine, ESV and EF showed accurate results compared with nonTSENSE cine. Both readers showed good agreement (kappa=0.72) in regional wall motion assessment comparing both techniques. Data acquisition for the multislice approach was significantly shorter ( approximately 75%) that in single-slice cine. We conclude that accurate evaluation of regional wall motion and left ventricular EF is possible using accelerated multislice cine MR with high spatial and temporal resolution.

Adolescent↗

MDCT urography: retrospective determination of optimal delay time after intravenous contrast administration.

The optimal delay time after intravenous (i.v.) administration of contrast medium (CM) for opacification of the upper urinary tract (UUT) for multidetector computed tomography urography (MDCTU) was investigated. UUT opacification was retrospectively evaluated in 36 four-row MDCTU examinations. Single- (n=10) or dual-phase (n=26) MDCTU was performed with at least 5-min delay after i.v. CM. UUT was divided into four sections: intrarenal collecting system (IRCS), proximal, middle and distal ureter. Two independent readers rated UUT opacification: 1, none; 2, partial; 3, complete. Numbers and percentages of scores, and the 5%, 25%, 50%, 75% and 95% percentiles of delay time were calculated for each UUT section. After removing diseased segments, 344 segments were analysed. IRCS, proximal and middle ureter were completely opacified in 94% (81/86), 93% (80/86) and 77% (66/86) of cases, respectively. Median delay time was 15 min for complete opacification. The distal ureter was completely opacified in 37% (32/86) of cases and not opacified in 26% (22/86). Median delay time for complete opacification was 11 min with 25% and 75% percentiles of 10 and 16 min, respectively. At MDCTU, opacification of the IRCS, proximal and middle ureter was hardly sensitive to delay time. Delay times between 10 and 16 min were favourable in the distal ureter.

Adult↗