Search PubMed⌕ Search

Biomedical subjects

Matthew J Budoff

Publications and source records attributed to Matthew J Budoff.

At least 37 records · Page 2Linked to original sources

Assessment of coronary plaque morphology by contrast-enhanced computed tomographic angiography: comparison with intravascular ultrasound.

BACKGROUND: Computed tomographic (CT) angiography provides accurate noninvasive assessment for coronary artery stenosis. The ability of CT angiography to determine plaque morphology remains unclear. METHODS: Twelve patients undergoing intravascular ultrasound for clinical indications underwent CT angiography for the evaluation of plaque morphology. Plaque morphology was classified as (1) soft, (2) fibrous, (3) fibrocalcific or (4) calcific. CT angiography data sets were evaluated for the presence and morphology of plaque in the coronary artery segments. The results were blindly compared with intravascular ultrasound results on a segment by segment basis using angiographic landmarks. RESULTS: Fifty-nine coronary segments were analyzed; 10 segments were normal and 49 contained plaque. Plaque morphology by intravascular ultrasound was soft in 12 segments, fibrous in four, fibrocalcific in 29 and calcific in four. To determine coronary segments with any plaque, CT angiography had a sensitivity of 100% (49 of 49) and specificity of 90% (9 of 10). To determine plaque morphology as calcified (fibrocalcific and calcific) versus noncalcified (soft and fibrous), CT angiography had a sensitivity of 100% (33 of 33) and a specificity of 94% (15 of 16). Overall accuracy for CT angiography to determine plaque morphology was 92% (54 of 59). CT angiography density values (Hounsfield units, mean+/-standard deviation) were significantly different for each plaque morphology: soft 23+/-71, fibrous 108+/-79, fibrocalcific 299+/-112 and calcific 404+/-264 (P<0.0001). CONCLUSIONS: CT angiography accurately characterized plaque morphology and may be a useful tool in noninvasive evaluation of plaque morphology during drug therapy trials.

Contrast Media↗

Comparison of three generations of electron beam tomography on image noise and reproducibility, a phantom study.

UNLABELLED: The detection of coronary artery calcification (CAC) using the electron beam tomography (EBT) scanner provides a noninvasive indicator for coronary artery disease (CAD). Physicians interested in preventative medicine also are using this modality to track atherosclerosis over time. Two new iterations of the EBT scanner have been introduced. We sought to evaluate the image quality of each machine to examine whether patients scanned on a previous model would have similar image quality and results to those scanned on the newest scanner. METHODS: This study used the C-150 XP, C300, and the e-Speed EBT scanners in high-resolution volume mode. A cork chest phantom was constructed for use as a human chest. A mixture of calcium phosphate, cornstarch and glue was placed inside the wells to simulate coronary calcium. The foci masses were 3, 5, 7, 10, 15, 20, 40, 60, 80, 100, and 200 mg (calcium mass), which provided the 55 foci of different masses and densities to simulate coronary calcium in the chest phantom. Each phantom was scanned multiple times, using both 1.5- and 3-mm slice thickness and table collimation settings with each scanner. RESULTS: There were no statistical differences found between the 1.5-mm and 3.0-mm slice thickness calcium foci scores (Agatston & volumetric) for all 3 EBT scanners. The C-150 XP scanner had a variability of 6.01% between 1.5-mm and 3.0-mm slice thickness. Analysis by t test revealed that the mean noise value of C-150 XP was significantly higher than the C300, e-Speed (50 milliseconds), and e-Speed (100 milliseconds) with P values of 0.001, 0.025, and 0.001, respectively. Comparison of 1.5-mm versus 3.0-mm slice thickness noise value showed a significant difference only for the C-150 XP scanner (P < 0.05). CONCLUSIONS: The use of the 3 EBT scanners in longitudinal studies of patients coronary calcium score is feasible to obtain similar calcium score values. The C-150 XP has the greatest noise effect in comparison to the C300 and e-Speed scanners. Improved image noise should improve reproducibility of the calcium measurement with these newer devices.

Calcinosis↗

Coronary calcium scanning.

While there is no doubt that high-risk patients (those with more than a 20% 10-year risk of a future cardiovascular event) need more aggressive preventive therapy, a majority of cardiovascular events occur in individuals at intermediate risk (10%-20% 10-year risk). Data suggest that it will be most cost-effective to concentrate screening efforts on this group of patients. Coronary artery calcium has been shown to be highly specific for atherosclerosis, occurring only in the intima of the coronary arteries. There is evidence to show that elevated coronary calcium scores are predictive of cardiovascular events, both independently of and incrementally to conventional cardiovascular risk factors. Based on current available data, patients with increased plaque burdens (increased coronary calcium scores) are approximately 10 times more likely to suffer a cardiac event over the next 3-5 years. Coronary calcium scores have outperformed conventional risk factors, high sensitivity C-reactive protein, and carotid intima-media thickness as a predictor of cardiovascular events. Both electron beam tomography and multidetector computed tomography can accurately detect and quantify the coronary calcium scores. In summary, coronary calcium detection significantly improves the accuracy of global cardiovascular risk prevention, the noninvasive tracking of the atherosclerotic burden, and the prediction of cardiovascular events.

C-Reactive Protein↗

Ethnic differences of the presence and severity of coronary atherosclerosis.

BACKGROUND: Although cardiovascular risk factor levels are substantially different in Caucasians, African-American, Hispanics, and Asians, the relative rates of coronary heart disease in these groups are not consistent with these differences. The objective of the study is to assess the differences in the prevalence and severity of coronary artery calcification, as a measure of atherosclerosis, in these different ethnic groups. METHODS: Electron-beam tomography was performed in 16,560 asymptomatic men and women (Asians=1336, African-Americans=610, Hispanics=1256) aged >or=35 years referred by their physician for cardiovascular risk evaluation. The study population encompassed 70% males, aged 52+/-8 years. RESULTS: Caucasians were more likely to present with dyslipidemia (p<0.0001), while African-Americans and Hispanics had a higher prevalence of smoking, diabetes, and hypertension (all p<0.001). After adjustment for age, gender, risk factors, and treatment for hypercholesterolemia, compared with Caucasians, the relative risks for men having coronary calcification were 0.64 (95% CI: 0.48-0.86) in African-Americans, 0.88 (95% CI: 0.67-1.15) in Hispanics, and 0.66 (95% CI: 0.55-0.80) in Asians. After similar adjustments, the relative risks for women having coronary calcification, were 1.58 (95% CI: 1.13-2.19) for African-Americans, 0.84 (95% CI: 0.66-1.06) in Hispanics, and 0.71 (95% CI: 0.56-0.89) in Asian women. After adjusting for age and risk factors using multivariable analysis, African-American men were least likely to have any coronary calcium while African-American women had significantly higher OR of any calcification. Asian men and women had significantly lower OR of any calcification. There was no significant difference in prevalence or severity of atherosclerosis between Hispanics and Caucasians, in men or women. CONCLUSIONS: Our study results demonstrate significant difference in the presence as well as severity of calcification according to ethnicity, independent of atherosclerotic risk factors. Results from this study (physician referred) closely parallel the results from MESA (population based, measured risk factors). Ethnic specific data on the predictive value of differing coronary calcium scores are needed.

Black or African American↗

Difference in atherosclerosis burden in different nations and continents assessed by coronary artery calcium.

We utilized coronary artery calcium scores (CACS) to assess differences in atherosclerosis burden between asymptomatic White populations living in continents with different cardiovascular disease rates. The similarities in the genetic pool between Brazilian and Portuguese Caucasian subjects offered an opportunity to assess the influence of environmental factors on the development of atherosclerosis. We reviewed CACS data from 17,563 individuals (12,378 men and 5169 women) collected in the USA (74% of the subjects), Brazil (15% of the subjects) and Portugal (11% of the subjects). CACS was absent in 80 and 88% of Portuguese men and women, compared with 46 and 62% and 33 and 59% of Brazilian and US counterparts (p<0.0001). Although the US subjects showed the lowest prevalence of risk factors they had a higher median (interquartile range) CACS than the Brazilian and the Portuguese cohorts: 4 (0;87), 1 (0;68) and 0 (0;0), respectively (p<0.0001). After adjusting for differences in age and cardiovascular risk factors, US men showed higher relative risk ratios of having any CACS than either Brazilian or Portuguese men. Brazilian and US women did not differ as far as risk of CACS although they demonstrated a greater risk than Portuguese women. In this study, significant differences in CACS were detected among three nations in different continents. The CACS differences paralleled the respective cardiovascular mortality rates.

Adult↗

Visualizing coronary calcium is associated with improvements in adherence to statin therapy.

BACKGROUND: Many patients lack motivation to control cardiovascular risk factors and clinicians have long sought ways to activate apathetic patients. Despite significant and consistent data on the benefits of lipid-lowering agents to reduce cardiovascular events, adherence and utilization of these agents remains low. We evaluated whether visualization of coronary calcium would positively affect patients' adherence rates. METHODS: We evaluated patients who underwent electron beam tomography (EBT) coronary calcium evaluation at least 1 year prior with a survey questioning them about health behaviors. Patients filled out baseline and follow-up questionnaires relating to lifestyle modifications, including statin utilization, diet, exercise, tobacco cessation and vitamin/antioxidant utilization. RESULTS: The study population consisted of 505 individuals on statin therapy on baseline who were followed for a mean of 3 +/- 2 years. Overall the statin compliance was lowest (44%) among those with CAC score in the first quartile (0-30), whereas 91% of individuals with baseline CAC score in the fourth quartile (>or= 526) adhered to statin therapy. In multivariable analysis, after adjusting for cardiovascular risk factors, age, and gender, higher baseline CAC scores were strongly associated with adherence to statin therapy. CONCLUSIONS: In addition to risk stratification for the asymptomatic person, patients visualizing coronary artery calcium may improve utilization and adherence to lipid-lowering therapy. Outcome studies and randomized trials need to be done to quantify the true value and cost-effectiveness of this approach.

Calcinosis↗

Detection of small vessels with electron beam computed tomographic angiography using 1.5 and 3 mm collimator protocols.

OBJECTIVES: To evaluate the effect of scanner collimation on the ability to detect small cardiac vessels using electron beam CT coronary angiography (EBA). MATERIALS AND METHODS: EBA scans from 40 patients who underwent study on two separate occasions with 3 mm (initial scan) and 1.5 mm (follow-up scan) collimation protocols were analyzed. Vessels of <2 mm in diameter were identified. RESULTS: The 1.5 mm collimation allowed 3-D visualization of 129 vessels<2 mm in diameter, while 3 mm collimation only allowed visualization of 89 vessels (p<0.001). The right coronary artery branches and distal LAD segments though were not displayed satisfactorily in almost half of the 3-D studies with either protocol. CONCLUSIONS: There was significant improvement in detection of small cardiac vessels with a 1.5 mm collimation EBA protocol compared to a 3 mm protocol. Both protocols though were insufficient for reliable visualization of the right coronary artery branches and distal LAD segments.

Coronary Angiography↗

Angiotensin-converting enzyme inhibitors and change in aortic valve calcium.

BACKGROUND: Calcium accumulation in the aortic valve is a hallmark of aortic sclerosis and aortic stenosis. Because lipoproteins, angiotensin-converting enzyme, and angiotensin II colocalize with calcium in aortic valve lesions, we hypothesized an association between angiotensin-converting enzyme inhibitor (ACEI) use and lowered aortic valve calcium (AVC) accumulation, as measured by electron beam computed tomography. METHODS: Rates of change in volumetric AVC scores were determined retrospectively for 123 patients who had undergone 2 serial electron beam computed tomographic scans. The mean (+/-SD) interscan interval was 2.5 (+/-1.7) years; 80 patients did not receive ACEIs and 43 received ACEIs. The relationship of ACEI use to median rates of AVC score change (both unadjusted and adjusted for baseline AVC scores and coronary heart disease risk factors) was determined. We also examined the relationship of ACEI use to the likelihood of and adjusted odds ratio for definite progression (AVC change >2 times the median interscan variability). RESULTS: Unadjusted and adjusted median rates of AVC score change were significantly higher in the no-ACEI group than in the ACEI group (adjusted median AVC changes [95% confidence interval]: relative, 28.7%/y [18.9%-38.5%/y] vs 11.0%/y [-1.9% to 24.0%/y], P = .04; absolute: 25.1/y [19.7-30.5/y] vs 12.2/y [4.5-19.9/y], P = .02). The adjusted odds ratio (95% confidence interval) for definite AVC progression was significantly lower for patients who received ACEIs (0.29 [0.11-0.75], P = .01). CONCLUSIONS: This retrospective study finds a significant association between ACEI use and a lower rate of AVC accumulation. The results support the need for prospective, randomized trials of ACEIs in calcific aortic valve disease.

Aged↗

Relation of family history of premature coronary heart disease and metabolic risk factors to risk of coronary arterial calcium in asymptomatic subjects.

We studied 6,141 consecutive, asymptomatic, nondiabetic patients who underwent electron beam tomography and explored the interaction between metabolic risk factors (RFs) and premature family history (FH) of coronary heart disease (CHD) in predicting the presence and severity of coronary arterial calcium (CAC). In the presence of >2 metabolic RFs, patients with a positive FH of premature CHD had a significantly higher prevalence of any CAC, CAC >/=100, and CAC >/=75th age-gender percentile than those without a FH of CHD. Our study demonstrated that a familial propensity to subclinical atherosclerosis interacts with the presence of >/=2 metabolic RFs, magnifying the risks for those exposed to both.

Calcinosis↗

Role of noninvasive testing in the clinical evaluation of women with suspected coronary artery disease: Consensus statement from the Cardiac Imaging Committee, Council on Clinical Cardiology, and the Cardiovascular Imaging and Intervention Committee, Council on Cardiovascular Radiology and Intervention, American Heart Association.

Cardiovascular disease is the leading cause of mortality for women in the United States. Coronary heart disease, which includes coronary atherosclerotic disease, myocardial infarction, acute coronary syndromes, and angina, is the largest subset of this mortality, with >240,000 women dying annually from the disease. Atherosclerotic coronary artery disease (CAD) is the focus of this consensus statement. Research continues to report underrecognition and underdiagnosis of CAD as contributory to high mortality rates in women. Timely and accurate diagnosis can significantly reduce CAD mortality for women; indeed, once the diagnosis is made, it does appear that current treatments are equally effective at reducing risk in both women and men. As such, noninvasive diagnostic and prognostic testing offers the potential to identify women at increased CAD risk as the basis for instituting preventive and therapeutic interventions. Nevertheless, the recent evidence-based practice program report from the Agency for Healthcare Research and Quality noted the paucity of women enrolled in diagnostic research studies. Consequently, much of the evidence supporting contemporary recommendations for noninvasive diagnostic studies in women is extrapolated from studies conducted predominantly in cohorts of middle-aged men. The majority of diagnostic and prognostic evidence in cardiac imaging in women and men has been derived from observational registries and referral populations that are affected by selection and other biases. Thus, a better understanding of the potential impact of sex differences on noninvasive cardiac testing in women may greatly improve clinical decision making. This consensus statement provides a synopsis of available evidence on the role of the exercise ECG and cardiac imaging modalities, both those in common use as well as developing technologies that may add clinical value to the diagnosis and risk assessment of the symptomatic and asymptomatic woman with suspected CAD.

Coronary Artery Disease↗

Electron beam angiography for the evaluation of percutaneous atrial septal defect closure.

Electron beam angiography (EBA) provides excellent anatomic imaging in patients with congenital heart disease and may be useful in the assessment of atrial septal defects (ASDs). We present four patients with an ASD who were considered for percutaneous closure and underwent EBA for measurement of defect size and assessment of rim adequacy, adjacent cardiac structures, and associated congenital anomalies.

Adult↗

Comparison of coronary artery calcium screening image quality between C-150 and e-Speed electron beam scanners.

RATIONALE AND OBJECTIVE: The newest generation of electron beam tomographic scanner (e-Speed) has increased spatial and temporal resolution compared with the C-150 XP scanner. The aim of this study was to evaluate coronary artery calcium screening image quality between the e-Speed and C-150 scanners (GE Imatron, San Francisco, CA). MATERIALS AND METHODS: Studies from 41 patients (14 women and 27 men) who underwent serial coronary artery calcium screening with the C-150 (first study) and the e-Speed (second study) were analyzed. Individual computed tomography (CT) slices were assessed for coronary artery motion artifacts, and CT Hounsfield units (HU) and noise values (CT HU standard deviation) at 16 discrete cardiac sites were measured and averaged. RESULTS: With the e-Speed scanner, there were significant decreases in right coronary artery motion artifacts compared with the C-150 scanner (0.3% versus 1.8%, P < .001) as well as decreased noise values (24.3 versus 32.0 HU, P < .001). CONCLUSION: Image quality is significantly improved with use of the e-Speed scanner, due to its improved temporal and spatial resolution, compared with the C-150 scanner.

Artifacts↗

Association between progression of aortic valve calcification and coronary calcification: assessment by electron beam tomography.

RATIONALE AND OBJECTIVES: It has been demonstrated that aortic valve calcification (AVC) shares many similarities with coronary atherosclerosis, including risk factors and pathologic characteristics. We sought to examine the relationship of AVC to coronary artery calcification (CC), to assess whether similar risk factors affect the process in a similar way. MATERIALS AND METHODS: The study included 620 asymptomatic persons (513 men and 107 women, mean age 59 years range [30-82]) who underwent two consecutive electron beam tomography (EBT) scans at least 1 year apart (mean 3.3 years). Calcification scores were obtained by summation of Agatston and volumetric scores. Stabilization of calcium was defined as no increase in score per year or positive percent change in score </=1%/year. Progression was defined as a positive percent change in score >1%/year. Of 106 with AVC, 105 (99%) had CC. Sixty-five patients had an AVC >10 on initial scan, and 50 (77%) demonstrated progression on the follow-up scan. Of 394 participants with CC >10 on initial scan, follow-up scans showed CC stabilization in 64 (16.2%) and CC progression in 330 (83.8%). Patients with AVC were significantly older than those with only CC (64.5 versus 56.5 years, P < .0001). The average age of the patient with AVC was 7 years older than the average age with CC. AVC (by volumetric score) progressed more rapidly in patients with diabetes (P = .036) and smoking (P = .042) than those without. RESULTS: We found no difference in the degree of change in the CC scores (by Agatston or volumetric methods) over time between men and women, or in any baseline cardiac risk factor (P > .05 for all measures). In 65 patients with both AVC and CC >10, there was a significant association between progression of AVC and CC (P = .047); the absolute rate of change of AVC was 24.5 +/- 43.2 %/year, and CC was 28.0 +/- 49.1 %/year. CONCLUSION: Virtually all patients with AVC had CC, potentially explaining the coronary risk associated with AVC. There is substantially parallel development between rates of progression of EBT-assessed AVC and CC.

Adult↗

Diabetes and progression of coronary calcium under the influence of statin therapy.

BACKGROUND: Coronary artery calcium (CAC) is a sensitive marker for the detection of coronary heart disease (CHD). Coronary artery calcification can be accurately quantified using electron beam tomography (EBT). We sought to evaluate the progression of atherosclerosis in asymptomatic persons with type 2 diabetes and measure the influence of statin therapy on CAC progression. METHODS: We evaluated 163 asymptomatic patients with type 2 diabetes (120 men, 43 women). Patients were physician referred and underwent 2 consecutive EBT scans at least 1 year apart. Demographic data, risk factors for CHD, and medication use were collected. Patients with symptoms or known CHD were excluded. RESULTS: The mean age was 65 +/- 10 years. The mean CAC score at baseline was 651 +/- 414. Only 9 (6%) of 163 of participants had scores of 0 at baseline. The time between scans averaged 27 +/- 15 months. Patients not treated with statins demonstrated a median annual increase in CAC progression of 20% (4%-44%), whereas statin-treated patients demonstrated increase of 10% (4%-25%) (P = .0001). Hemoglobin A 1c was weakly associated with CAC progression. CONCLUSIONS: Asymptomatic diabetic patients show a high prevalence of atherosclerosis based on high frequency of coronary calcification. Statin therapy induced a 50% reduction in the rate of CAC progression. As rapid CAC progression has been associated with coronary events, EBT may serve as a noninvasive method for following atherosclerosis and response to therapy.

Adult↗

Coronary venous imaging with electron beam computed tomographic angiography: three-dimensional mapping and relationship with coronary arteries.

BACKGROUND: The coronary venous system can provide vascular access for diagnostic and therapeutic procedures. Visualization of the coronary veins and their relationship to other cardiac structures may play an important role in facilitating these procedures. We sought to assess the ability of electron beam computed tomographic angiography (EBCTA) to characterize 3-dimensional (3-D) coronary venous anatomy. METHODS: Two hundred thirty-one consecutive EBCTA coronary studies were analyzed. The coronary venous system was mapped and analyzed using 2- and 3-D images with definition of diameter and angulations of branch vessels and distance from CS os. RESULTS: The coronary sinus (CS), great cardiac, middle cardiac, left ventricular (LV) anterior interventricular, LV marginal, LV posterior, left atrial, and right atrial veins were visualized in 100%, 100%, 100%, 100%, 78%, 81%, 6%, and 8% of the studies, respectively, with definition of diameter and angulations of branch vessels and distance from CS os. There was a significant linear correlation between CS diameter and right atrial end systolic volume (R = 0.244, n = 81, P < .05). No significant correlation existed between CS os diameter and other cardiac size or function parameters. The 3-D spatial arrangements between the coronary veins and the coronary arteries in relation to the epicardium were able to be defined, on the basis of the vessel closer to the epicardium in overlapping segments. CONCLUSIONS: EBCTA can provide 3-D visualization of most components of the coronary venous system and definition of the spatial relationships with coronary arteries. EBCTA may potentially serve as a useful noninvasive tool for coronary venous imaging for procedures involving coronary veins, such as resynchronization therapy.

Adult↗