Search PubMed⌕ Search

Biomedical subjects

Matthew G Hillebrenner

Publications and source records attributed to Matthew G Hillebrenner.

2 recordsLinked to original sources

Mechanistic inquiry into decrease in probability of defibrillation success with increase in complexity of preshock reentrant activity.

Energy requirements for successful antiarrhythmia shocks are arrhythmia specific. However, it remains unclear why the probability of shock success decreases with increasing arrhythmia complexity. The goal of this research was to determine whether a diminished probability of shock success results from an increased number of functional reentrant circuits in the myocardium, and if so, to identify the responsible mechanisms. To achieve this goal, we assessed shock efficacy in a bidomain defibrillation model of a 4-mm-thick slice of canine ventricles. Shocks were applied between a right ventricular cathode and a distant anode to terminate either a single scroll wave (SSW) or multiple scroll waves (MSWs). From the 160 simulations conducted, dose-response curves were constructed for shocks given to SSWs and MSWs. The shock strength that yielded a 50% probability of success (ED(50)) for SSWs was found to be 13% less than that for MSWs, which indicates that a larger number of functional reentries results in an increased defibrillation threshold. The results also demonstrate that an isoelectric window exists after both failed and successful shocks; however, shocks of strength near the ED(50) value that were given to SSWs resulted in 16.3% longer isoelectric window durations than the same shocks delivered to MSWs. Mechanistic inquiry into these findings reveals that the two main factors underlying the observed relationships are 1) smaller virtual electrode polarizations in the tissue depth, and 2) differences in preshock tissue state. As a result of these factors, intramural excitable pathways leading to delayed breakthrough on the surface were formed earlier after shocks given to MSWs compared with SSWs and thus resulted in a lower defibrillation threshold for shocks given to SSWs.

Animals↗

Postshock arrhythmogenesis in a slice of the canine heart.

INTRODUCTION: Recent evidence has demonstrated that defibrillation shocks terminate or reset reentrant activity in the myocardium through the generation of virtual electrode polarization (VEP). Previous research has revealed that the shock establishes phase singularities (PSs) in the tissue via the VEP mechanism. The aim of this study was to examine, as a function of shock strength and electrode configuration, the relationship between end-shock PSs and the reentrant circuits established after failed defibrillation attempts. METHODS AND RESULTS: The study uses a complex three-dimensional finite-element bidomain model of a slice of the canine heart characterized by realistic geometry and fiber architecture and undergoing a single scroll wave. Defibrillation shocks of increasing strength are delivered through three different electrode configurations. The results demonstrated that >98% of all PSs have a lifetime of half a reentrant cycle or less. Stronger shocks result in a faster rate of annihilation of postshock PSs. For failed shocks, the surviving PSs underlie the activity of one or more scroll waves, which remain stationary in the slice. For all electrode configurations tested, the increase in shock strength leads to a rapid initial increase in the number of postshock reentries followed by a slower decrease; similar behavior is observed with regard to end-shock PSs. CONCLUSION: These results present new evidence regarding the mechanisms underlying failure of defibrillation shocks.

Animals↗