In vitro comparison of four cerebral protection filters for preventing human plaque embolization during carotid interventions.

PURPOSE: To evaluate in an in vitro bench-top model the efficacy of 4 filtration devices designed for cerebral protection during carotid angioplasty. METHODS: Embolization during carotid angioplasty was simulated with human plaque material (8 to 12 particles weighing 6.02 +/- 0.10 mg) in an open flow model with the aortic arch and carotid bifurcation made from elastic silicone tubes and saline used as the fluid medium. The 500 to 1500-microm particles were injected into the internal carotid artery (ICA) in front of the test protection device, which was deployed 5 cm distal to the bifurcation. Particles getting past the protection device or flowing into the external carotid artery (ECA) were caught in 100-microm filters and weighed. Ten trials were made on each of 4 devices: Angioguard, FilterWire EX, TRAP, and NeuroShield. All were deployed according to the manufacturers' directions except the FilterWire, which was manually repositioned in all tests to eliminate a gap between the filter and the tube wall. RESULTS: The lowest weight of missed particles in the effluent was obtained with the NeuroShield (0.05 +/- 0.04 mg, 0.8% of injected particle weight) and FilterWire (0.08 +/- 0.05 mg, 1.3%; p=0.254 compared to NeuroShield, p=0.006 versus TRAP). The weight of particles missed by the TRAP device (0.16 +/- 0.06 mg, 2.6%; p<0.001 versus NeuroShield and Angioguard, p<0.05 compared to FilterWire) was higher, and the largest amount of missed particles was observed with the Angioguard filter (0.27 +/- 0.06 mg, 4.4%; p<0.001 compared to all). NeuroShield and FilterWire were significantly different (p<0.001) compared to Angioguard and TRAP in a pairwise analysis. No embolization into the ECA occurred. CONCLUSIONS: In vitro, none of the tested devices had the ability to completely prevent embolization into the ICA. Comparing current designs, the NeuroShield filter and the FilterWire EX captured the highest percentage of human particles in this in vitro model, probably due to their larger filter volume.

Balloon Occlusion↗

Expression of the Neural Recognition Molecule L1 by Cultured Neural Cells is influenced by K+ and the Glutamate Receptor Agonist NMDA.

To investigate the influence of neuronal activity on the expression of neural recognition molecules, cultures of neural cell lines and dissociated cells of early postnatal mouse cerebellum were maintained in the presence of elevated concentrations of K+ and the glutamate agonist N-methyl-d-aspartate (NMDA). Levels of expression of the neural adhesion molecules L1 and N-CAM at the cell surface were measured by an enzyme-linked immunosorbent assay. Expression of L1 was up-regulated in neuroblastoma N2A cells after 1 day of maintenance in 40 and 60 mM K+, but not in phaeochromocytoma PC12 cells. Expression levels of N-CAM and antigens recognized by the monoclonal antibody A2B5 or by polyclonal antibodies to crude membrane fractions of liver were not significantly altered by elevated K+ concentrations in these two cell lines. In monolayer cultures of early postnatal mouse cerebellum, an increase of 60% in expression of L1, but not N-CAM or A2B5, was seen at 20 and 40 mM K+. This increase in L1 expression was specifically inhibitable by the Ca2+ channel blocker nicardipine. NMDA at a concentration of 100 microM increased levels of L1, but not of N-CAM. This increase was inhibitable by the NMDA antagonists 2-amino-5-phosphonovalerate and MK-801, but not significantly by the kainate/quisqualate antagonist 6-cyano-7-nitroquinoxaline-2,3-dione. The increase in L1 expression at higher K+ concentrations was not inhibitable by the NMDA antagonists, indicating that the K+-mediated increase in L1 expression is not due to release of glutamate by cerebellar neurons. These observations indicate that compounds influencing neuronal membrane properties, and thus neuronal excitability, are capable of regulating the expression of L1. In a more general context, these findings suggest that previously observed changes in synaptic connectivity in situ, resulting from activity-dependent fine tuning of neuronal morphology, may be mediated by alterations in the expression of recognition molecules.

Journal Article↗

Micro-CT of carotid arteries: a tool for experimental studies.

Micro-computed tomography (micro-CT) is a high-resolution, non-destructive tool for two- and three-dimensional imaging and quantification. The ability of this technique to assess atherosclerosis of the carotid artery was evaluated in three human cadaver samples based on the original axial acquisitions, multiplanar reconstructions and volume rendering techniques. Quantitative analysis included the calculation of: (1) the original lumen perimeter, original lumen area, plaque area, residual lumen area, calcified area and gross sectional area reduction of the vascular lumen from two-dimensional slices; (2) the total tissue volume, soft tissue volume and calcified tissue volume from the three-dimensional data set. This preliminary study demonstrates the potential of micro-CT as a supplementary method for the two- and three-dimensional ex vivo evaluation of carotid atherosclerosis.

Aged↗

Influence of thrombus age on the mechanical thrombectomy efficacy of the amplatz thrombectomy device in vitro.

PURPOSE: To determine the efficacy of thrombectomy for the Amplatz Thrombectomy Device (ATD) according to the age of the thrombus. METHODS: Thrombectomy was performed with the 7 Fr or 8 Fr ATD. Five-day-old or 8-day-old thrombi were made from porcine blood by clotting within silicone tubes to be used in a flow model. Emboli sizes, weight, remaining thrombus and activation time were evaluated. RESULTS: The age of the thrombus had no influence on the activation time necessary for complete thrombolysis. A significant difference was found in the overall amount of embolization only with the 7 Fr device although a similar trend was shown with the 8 Fr device. The amount of embolized thrombotic material was higher for both devices if older thrombi (i.e., 8 days old) were processed. The overall impression was that the 8 Fr device showed slightly better results (less remaining thrombus and embolization). CONCLUSION: A tendency toward higher amounts of embolization was observed if older thrombi were used in the model. Therefore the interventional radiologist should be aware of the potentially higher risk of peripheral embolization when performing mechanical thrombectomy (with the ATD) in older thrombotic occlusions, especially since the higher rate of embolization was mainly due to an increased proportion of larger embolic particles (1 mm), which are clinically more significant.

Animals↗

Mid-term results after endovascular stent-grafting of descending aortic aneurysms in high-risk patients.

PURPOSE: To analyze our experience with endovascular stent-grafting of descending aortic aneurysms in high-risk patients. METHODS: Nineteen patients underwent endovascular stent-graft repair of descending aortic aneurysms using the Talent Stent Graft System (Medtronic). All patients were considered high-risk for open surgical repair due to their age, requirement for emergency surgery, and comorbidities. Computed tomography and/or MR tomography were performed at 3, 6 and 12 months postoperatively and thereafter every 12 months. RESULTS: Secondary technical success was 100%. Thirty-day mortality was 5%. Incidence of postoperative stroke and paraplegia were 5% each. One patient required a second stent-graft due to a type I endoleak during the same hospital stay (primary technical success 95%). All patients have been followed for a median of 20 months. No migration, wire fractures or endoleak appeared during follow-up. CONCLUSION: Endovascular stent-grafting had a low 30-day mortality and morbidity in high-risk patients. One patient developed an aortoesophageal fistula 40 days after stent implantation. Stent-graft repair is a valuable supplement to surgical therapy in high-risk patients.

Adult↗

Stent-protected carotid angioplasty using a membrane stent: a comparative cadaver study.

PURPOSE: To evaluate the performance of a prototype membrane stent, MembraX, in the prevention of acute and late embolization and to quantify particle embolization during carotid stent placement in human carotid explants in a proof of concept study. METHODS: Thirty human carotid cadaveric explants (mild stenoses 0-29%, n = 23; moderate stenoses 30-69%, n = 3; severe stenoses 70-99%, n = 2) that included the common, internal and external carotid arteries were integrated into a pulsatile-flow model. Three groups were formed according to the age of the donors (mean 58.8 years; sample SD 15.99 years) and randomized to three test groups: (I) MembraX, n = 9; (II) Xpert bare stent, n = 10; (III) Xpert bare stent with Emboshield protection device, n = 9. Emboli liberated during stent deployment (step A), post-dilatation (step B), and late embolization (step C) were measured in 100 microm effluent filters. When the Emboshield was used, embolus penetration was measured during placement (step D) and retrieval (step E). Late embolization was simulated by compressing the area of the stented vessel five times. RESULTS: Absolute numbers of particles (median; >100 microm) caught in the effluent filter were: (I) MembraX: A = 7, B = 9, C = 3; (II) bare stent: A = 6.5, B = 6, C = 4.5; (III) bare stent and Emboshield: A = 7, B = 7, C.=.5, D = 8, E = 10. The data showed no statistical differences according to whether embolic load was analyzed by weight or mean particle size. When summing all procedural steps, the Emboshield caused the greatest load by weight (p = 0.011) and the largest number (p = 0.054) of particles. CONCLUSIONS: On the basis of these limited data neither a membrane stent nor a protection device showed significant advantages during ex vivo carotid angioplasty. However, the membrane stent seems to have the potential for reducing the emboli responsible for supposed late embolization, whereas more emboli were observed when using a protection device. Further studies are necessary and warranted.

Adult↗