Simulated pulmonary nodules implanted in a dedicated porcine chest phantom: sensitivity of MR imaging for detection.

PURPOSE: To evaluate the diagnostic accuracy of common magnetic resonance (MR) imaging sequences for detection of small pulmonary nodules by using a chest phantom and porcine lungs containing simulated lesions. MATERIALS AND METHODS: Fourteen porcine lungs containing 366 porcine myocardial tissue implants were inflated inside a phantom. Two-dimensional (2D) and three-dimensional (3D) gradient-echo (GRE), T2-weighted turbo spin-echo (SE), and T2-weighted single-shot SE train MR sequences were performed. Spiral computed tomography (CT) was performed for comparison. Blinded observers read the images and recorded the sizes and locations of visible nodules by consensus. The sensitivity of each imaging method for depicting single nodules of given sizes was calculated. Specificities, positive predictive values (PPVs), and negative predictive values (NPVs) for detection of one or more nodules of various sizes were calculated. RESULTS: Sensitivities of 3D GRE, 2D GRE, T2-weighted turbo SE, and T2-weighted single-shot SE train MR imaging and of CT were 0.50, 0.40, 0.12, 0.00, and 0.55, respectively, for detection of 1.4-mm nodules and 0.88, 0.84, 0.69, 0.06, and 0.96, respectively, for detection of 4.2-mm nodules. The 95% CIs for CT and GRE MR imaging overlapped, but those for turbo SE and single-shot SE train MR imaging differed significantly (P <.05). For detection of nodules larger than 5 mm, all examinations except single-shot SE train MR imaging yielded a specificity, PPV, and NPV of 1.00 each. For detection of nodules smaller than 5 mm, diagnostic accuracy of 3D GRE MR imaging was high: Specificity, PPV, and NPV all were approximately 0.90. Two-dimensional GRE MR imaging results were influenced by false-positive findings: Specificity was 0.64; PPV, 0.74; and NPV, 1.00. CONCLUSION: Common MR imaging sequences such as 3D GRE have high diagnostic accuracy in depicting small pulmonary nodules when artifacts from cardiac and respiratory motion are absent.

Animals↗

Differentiation of cerebral tumors using multi-section echo planar MR perfusion imaging.

OBJECTIVE: We have investigated the performance of magnetic resonance (MR) perfusion imaging to differentiate between astrocytomas grade II, grade III and glioblastomas in a prospective study. MATERIALS AND METHODS: In 33 patients with suspected supratentorial primary cerebral tumors we performed multi-section Echo Planar MR perfusion imaging. Regional cerebral blood volume (rCBV) maps were calculated and the maximum rCBV was determined from the entire lesion. This value was divided by the mean rCBV value from the contralateral side, which provided the rCBV index used in this study. The rCBV index was correlated with the histological tumor classification after stereotactic biopsy (n=7) or open resection (n=26). RESULTS: The maximum rCBV index was 1.2+/-0.8 for grade II astrocytomas (n=3), 4.0+/-1.2 for grade III astrocytomas (n=13), and 10.3+/-3.3 for glioblastomas (n=17). The difference between grade III astrocytomas and glioblastomas was highly significant (P<0.001). DISCUSSION AND CONCLUSION: The rCBV index measured with multi-section Echo Planar MR perfusion is capable of differentiating grade III astrocytomas from glioblastomas. It serves as an additional parameter to establish a diagnosis in cases where it is not possible to clearly differentiate between these types of tumors on the basis of conventional MR imaging. MR perfusion imaging also provides information about spatial heterogeneities within a tumor which might improve diagnostic performance. This technology may also be of interest for follow-up examinations after histological diagnosis and further treatment.

Adult↗

The immunoglobulin-superfamily molecule basigin is a binding protein for oligomannosidic carbohydrates: an anti-idiotypic approach.

Recognition molecules that carry carbohydrate structures regulate cell interactions during development and play important roles in synaptic plasticity and regeneration in the adult. Glycans appear to be involved in these interactions. We have searched for binding proteins for oligomannosidic structures using the L3 antibody directed against high mannose-type glycans in an anti-idiotypic approach. A selected monoclonal anti-idiotype antibody was used for affinity chromatography and identified basigin as a binding protein from mouse brain detergent lysates. Basigin was found to bind to high mannose-carrying cell recognition molecules, such as myelin-associated glycoprotein, L1, the beta2-subunit of Na+/K+-ATPase and an oligomannosidic neoglycolipid. Furthermore, basigin was involved in outgrowth of astrocytic processes in vitro. A striking homology between the first immunoglobulin (Ig)-like domain of basigin and the fourth Ig-like domain of NCAM, previously shown to bind to oligomannosidic glycans, and the lectin domain of the mannose receptor confirms that basigin is an oligomannose binding lectin. To our knowledge this is the first report that anti-idiotypic antibodies can be used to identify binding partners for carbohydrates.

Amino Acid Sequence↗

The age-related decline in resting energy expenditure in humans is due to the loss of fat-free mass and to alterations in its metabolically active components.

There is conflicting evidence as to whether the age-related decline in resting energy expenditure (REE) can be attributed to i) absolute changes in fat-free mass (FFM), ii) alterations in the composition of FFM or iii) decreasing organ metabolic rates. This study directly addressed the first and second hypotheses by quantification of metabolically active components of FFM assuming constant tissue respiration rates to calculate REE (REEc). REE was measured (REEm) in 26 young (13 females, 13 males, age 22-31 y) and 26 elderly subjects (15 females, 11 males, age 60-82 y) by indirect calorimetry and detailed body composition analysis was obtained using bioelectrical impedance analysis (BIA), dual energy X-ray absorptiometry (DXA), and MRI. Specific organ metabolic rates were taken from the literature. REEm adjusted for differences in FFM was lower in older subjects than in younger control subjects (5.43 +/- 0.61 MJ/d compared with 6.37 +/- 0.48 MJ/d; P < 0.001). Skeletal muscle mass plus liver mass accounted for 86% and 48% of the variance in REE in young and elderly subjects, respectively. The difference between REEm and REEc was 0.03 +/- 0.40 MJ/d and -0.36 +/- 0.70 MJ/d in young and elderly subjects, respectively. In the elderly 58% of the difference in variance was attributed to heart mass. REEm - REEc was -1.40 +/- 0.44 MJ/d in subjects with hypertensive cardiac hypertrophy, i.e., heart mass > 500 g, suggesting a decrease in heart metabolic rate with increasing heart mass. Excluding five elderly subjects with cardiac hypertrophy resulted in agreement between REEm and REEc in the elderly (-0.10 +/- 0.48 MJ/d). We concluded that the age-related decline in REE is attributed to a reduction in FFM as well as in proportional changes in its metabolically active components. There is no evidence for a decreasing organ metabolic rate in healthy aging.

Adult↗

Hemobahn stent-grafts for treatment of femoropopliteal arterial obstructions: midterm results of a prospective trial.

PURPOSE: To report a prospective study to evaluate safety, effectiveness, and midterm patency of self-expanding stent-grafts in patients with femoropopliteal occlusive disease. MATERIALS AND METHODS: Sixty-three Hemobahn stent-grafts were used in 52 patients for treatment of medium- or long-segment (>3 cm) occlusions (82.7%) and stenoses (17.3%) of the femoropopliteal artery. The mean length of vessel segments covered was 10.9 cm +/- 5.13. Follow-up with documentation of clinical symptoms, assessment of Rutherford clinical stage of peripheral vascular disease, and color-coded duplex sonography was performed at discharge, at 1, 3, 6, 12, 18, and 24 months after implantation, and yearly thereafter. Mean follow-up duration was 23.8 months +/- 6.9 (range, 8-36 mo). Follow-up data at 12 and 24 months after treatment were available for 47 of 52 (90.4%) and 31 of 52 patients (59.6%), respectively. RESULTS: Device implantation was technically successful in all 52 patients, yielding an overall technical success rate of 100%. Procedure-related complications were observed in 12 of 52 patients (23.1%) and consisted of distal embolization (n = 4, 7.7%), minor groin hematoma (n = 7, 13.5%), and arteriovenous fistula (n = 1, 1.9%), but prolonged hospitalization and further medical, interventional, or surgical measures were not required. Stent-graft placement induced an initial improvement of the mean resting ankle-brachial index from 0.54 +/- 0.12 to 0.89 +/- 0.14 (P <.01). Primary patency rates at 12 and 24 months were 78.4% +/- 5.8 and 74.1% +/- 6.2, respectively. Primary assisted patency rates were 82.4% +/- 5.3 at 12 months and 80.3% +/- 5.6 at 24 months. Secondary patency rates at 12 and 24 months were 88.3% +/- 4.5 and 83.2% +/- 5.5, respectively. There was no significant difference (log-rank test, P >.3) between primary patency rates in patients grouped according to lengths of implanted grafts (ie, length of the treated lesions). CONCLUSION: Endovascular placement of Hemobahn stent-grafts for percutaneous treatment of medium- to long-segment high-grade stenoses and occlusions of the femoropopliteal artery is a safe procedure with excellent initial success rates and promising midterm results.

Aged↗

Comparison of various cerebral protection devices used for carotid artery stent placement: an in vitro experiment.

PURPOSE: To compare the effectiveness of five basic cerebral protection devices designed for carotid angioplasty in an in-vitro bench-top model. MATERIALS AND METHODS: Simulation of embolization from carotid angioplasty (n = 180) was performed with polyvinyl alcohol (PVA) particles (Contour; 150-1,000- micro m) in an open flow model simulating the aortic arch with a carotid bifurcation made from elastic silicone tubes. Particles (150-250 micro m [small], 355-500 micro m [medium], 710-1,000 micro m [large]; 5 mg each) were injected separately into the internal carotid artery (ICA) proximal to the placed protection device. Five devices were tested: the Angioguard (AG), Filter Wire EX (EX(A), EX(B)), Trap, Neuroshield (NS), and GuardWire Plus (GW). Particles getting past the protection device or flowing into the external carotid artery (ECA) were caught in a filter at the end of both arteries and their weight was determined. RESULTS: For small, medium, and large particles, the lowest weight of emboli in the effluent of the ICA was obtained with the NS (0.28 mg, 0.18 mg, and 0.07 mg, respectively; P <.001 compared to all other devices except the GW for small particles only). The GW had the highest embolization rate into the ECA for all particle sizes. When combining the particle weights for the different protection devices, the NS showed the lowest weight of emboli into the ICA filter (0.53 mg/3.5%; P <.001 compared to all [>1.1 mg/7.0%]). The GW revealed the highest weight of emboli into the ECA (1.2 mg/7.6%; P <.001 compared to all [<0.59 mg/0.09%]). Effectiveness of the EX(B) device was enhanced when circumferentially deployed under direct view (EX(B), 0.39 mg/2.58%; EX(A), 1.18 mg/7.81%; P <.001). CONCLUSIONS: In vitro, none of the tested devices or modifications has the ability to prevent embolization completely. An occlusion balloon leads to increased embolization into the ECA. The effectiveness of the EX might be enhanced with design improvements. During this evaluation, the NS was most effective for preventing PVA particle embolization of the three different particle groups within this in-vitro model.

Angioplasty, Balloon↗

Artificial thorax for MR imaging studies in porcine heart-lung preparations.

A double-walled magnetic resonance (MR) imaging-compatible container with a flexible diaphragm was designed to hold freshly excised porcine heart-lung preparations. The saline contents simulate MR signal of an actual chest wall. Continuous evacuation keeps the lung inflated. A variety of experiments with different imaging modalities, including angiography, under close to in vivo conditions are feasible. Access to bronchial system and lung vessels allows for various studies.

Animals↗

Lung morphology: fast MR imaging assessment with a volumetric interpolated breath-hold technique: initial experience with patients.

PURPOSE: To prospectively evaluate the clinical feasibility of magnetic resonance (MR) imaging of the lungs with fast volumetric interpolated three-dimensional (3D) gradient-recalled-echo (GRE) sequences and to compare this examination with standard computed tomography (CT) in patients with lung abnormalities. MATERIALS AND METHODS: Twenty-five patients with different lung abnormalities were examined with 3D GRE MR imaging. The small pulmonary nodules in seven, TNM stage of large intrapulmonary tumors in eight, and benign bronchial disease in five patients were evaluated. MR imaging-based diagnoses were compared with diagnoses made at CT and at discharge from the hospital. Contingency tables and the McNemar test were used to evaluate the significance of differences between MR imaging- and CT-based diagnoses. RESULTS: The MR imaging- and CT-based diagnoses were identical in 24 of 25 patients. In the remaining patient, clinical findings confirmed the accuracy of the MR imaging finding of pleural empyema. Ten of 15 solid pulmonary nodules smaller than 10 mm in diameter were detected at MR imaging (P >.1). Tumor stages at MR imaging and CT were identical, but lymph node stages at the two examinations differed in two of eight patients owing to overestimation of lymph node size at MR imaging (P >.2). In the five patients with bronchiectasis, MR imaging depicted 26 of 33 affected lung segments; differences between MR imaging and CT findings of bronchial dilatation (P >.05) and bronchial wall thickening (P >.2) were not significant. Peribronchial fibrosis was overestimated at MR imaging owing to image artifacts (P <.05). CONCLUSION: Study results confirmed the feasibility of fast breath-hold 3D GRE MR imaging of the lung.

Adolescent↗

Suspected pulmonary artery disruption after transvenous pulmonary embolectomy using a hydrodynamic thrombectomy device: clinical case and experimental study on porcine lung explants.

PURPOSE: To use porcine lung explants for reconstructing possible situations in which a vessel wall disruption might have occurred in a patient suffering fatal hemoptysis after pulmonary embolectomy with a hydrodynamic thrombectomy device. METHODS: A 76-year-old woman with massive pulmonary embolism underwent transvenous pulmonary embolectomy using a 6-F AngioJet Xpeedior catheter according to manufacturer's instructions. While activating the device in the middle lobe artery (approximately 8 mm diameter), massive and ultimately fatal arterial bleeding occurred through the tracheal tube. Because no autopsy was authorized, an experimental study was designed to examine possible causes for the vessel disruption. Five fresh porcine heart-lung preparations were examined inside a dedicated chest phantom. Access to the pulmonary vessels was provided through catheters inside the right and left ventricular outlets. A low-flow circulation was maintained with an external pump. The 6-F AngioJet thrombectomy device was activated at 42 sites inside vessels from 2 to 10 mm in diameter; in one lung, 8 activations were made after deliberately withdrawing the guidewire. RESULTS: Vessels >6 mm in diameter remained intact. Vessel wall disruption occurred in 4 of 7 vessels between 4 and 6 mm in diameter and in 13 of 14 segmental arteries <4 mm in diameter (regardless of whether or not a guidewire was used). The signs of vessel wall disruption included extravasation of contrast material, arteriovenous fistula, and laceration of distal airspaces with contrast inside the bronchus. CONCLUSIONS: The application of this system has to be considered potentially dangerous when activated inside vessels with diameters <6 mm. The use of this device appears to be safe only inside main branches of the lung vessels at this time. Additional experiments will be required to substantiate these initial results.

Aged↗

A rapid-exchange monorail stent system for salvage of failing femoropopliteal bypass grafts.

PURPOSE: To analyze the safety and effectiveness of a new monorail stent system for the treatment of failing femoropopliteal bypass grafts. TECHNIQUE: Acute distal occlusions or stenoses of femoropopliteal bypass grafts were treated with balloon-expandable stents (13 or 18-mm diameter) pre-mounted on a monorail balloon catheter system. The delivery system was assessed subjectively for (1). compatibility with the sheath, (2). lesion crossing potential, (3). radiopacity, (4). flexibility of the catheter, (5). adequacy of stent expansion, and (5). balloon refolding. In 8 failing bypass grafts with distal lesions, the delivery system successfully deployed the stent at the desired location. Sheath compatibility, catheter flexibility, lesion crossing, and stent expansion were rated "excellent" by all examiners for the 18-mm device. Radiopacity of the mounted stent was graded "good" before and during positioning, but only "sufficient" following expansion. For this type of lesion, the investigators rated the overall performance of the device superior to conventional "over-the-wire" systems. CONCLUSIONS: The monorail balloon-expandable stent delivery system provides rapid introduction of the device over the guidewire, and its low profile facilitates the use of small sheaths to minimize access-site complications.

Angiography, Digital Subtraction↗

Metabolically active components of fat free mass (FFM) and resting energy expenditure (REE) in humans.

Magnetic resonance imaging (MRI) can be used to assess metabolically active components of FFM. MRI-derived organ mass (OM) explains part of the interindividual variance in REE. It may also add to our understanding of malnutrition- and obesity-related variance in REE. There is need for (i) standardisation of MRI technology in body composition research, (ii) reference data on detailed body composition including also more recent autopsy data, (iii) reducing the number of assumptions in model-based predictions and (iv) a combination of imaging technologies with in vivo measurements of individual OM respiration (e.g. by positron emission tomography).

Absorptiometry, Photon↗

Hemolytic effect of deformed intra-arterial stents and stent grafts in vitro.

Our objective was to evaluate the hemolytic effect of stents and stent grafts in an in vitro flow model. The model consisted of silicone tubings. Pulsatile flow was delivered at 1170 ml/min. Diluted packed erythrocytes were used (hematocrit of 33%). The Palmaz, MegaLink stents or Passager, Hemobahn stent grafts were placed in the middle portion of the model; control experiments contained no implant ( n=10 each). Concentric stenosis of the implant was achieved by constricting the implant to 25, 50, or 70% (area, n=10 each). Samples were drawn at minute 1, 2, 4, 6, 8, 10, 15, and every 10 min up to 1 h. Hemolytic parameters were evaluated. All implants produced hemolysis, increasing in the course of time. Without deformation (0%) the Hemobahn stent causes less hemolysis compared with the other prostheses. At 25% no significant difference could be shown between all devices. At 50% constriction the Palmaz stent caused more hemolysis than the other grafts, and at 70% stenosis the Palmaz and Hemobahn caused more hemolysis than Passager or Megalink. A hemolytic effect was evaluable, probably due to mechanical stress and sheer forces, induced by turbulences in the proximity of the deformed stent. The stent grafts did not perform better than the stents. Differences in the design of a prosthesis and in the degree of stent deformation seem to have an influence on the hemolysis caused.

Blood Vessel Prosthesis↗

Active disease and residual damage in treated Wegener's granulomatosis: an observational study using pulmonary high-resolution computed tomography.

The purpose of this study was to determine to what extent high-resolution computed tomography (HRCT) of the lungs can distinguish active inflammatory disease from inactive cicatricial disease in patients treated for Wegener's granulomatosis (WG). Twenty-eight WG patients with active pulmonary disease underwent a first HRCT examination immediately before standard immunosuppressive treatment and a second examination after clinical remission had been achieved. Lesions remaining after treatment were categorized as residual damage and were compared with findings during active disease to see by what features active and cicatricial disease can be distinguished. During active disease 17 patients had nodules/masses, 12 had ground-glass opacities, 6 had septal lines and 6 had non-septal lines. After treatment, ground-glass opacities had resolved completely. Nodules/masses had resolved in 8 patients and had diminished in 7 patients. Residual nodules were distinguished from nodules/masses in active disease by lack of cavitation and a diameter of mostly <15 mm. In one-third of patients lines resolved, but in 8 instances new lines evolved during immunosuppression. During a follow-up period of a median 26.5 months (range 20.0-33.8), patients with residual nodules or lines had no more relapses than patients with completely cleared lungs. Treated pulmonary WG leaves substantial residual damage. High-resolution CT does assist in the distinction between active and inactive lesions. Ground-glass opacities, cavitating nodules/masses and masses measuring more than 3 cm represent active disease ordinarily. Non-cavitary small nodules and septal or non-septal lines can be either active or cicatricial lesions. The nature of these lesions needs to be clarified by longitudinal observation.

Adult↗

Endovascular placement of self-expanding nitinol coil stents for the treatment of femoropopliteal obstructive disease.

PURPOSE: To report on a prospective two-center study to evaluate safety and effectiveness of a self-expanding nitinol coil stent in patients with femoropopliteal obstructive disease. MATERIALS AND METHODS: The IntraCoil nitinol stent was used in 37 patients (28 men and nine women; mean age, 62.4 y plus minus 10.7; range, 43-81 y) presenting with high-grade stenoses (n = 23) or short (<3 cm) occlusions (n = 17) of the superficial femoral artery (SFA; n = 33) or popliteal artery (n = 4). Indications for stent placement were significant residual stenosis (>30%) or dissection after angioplasty. Follow-up evaluations with measurement of the Doppler ankle-brachial index (ABI), assessment of Rutherford clinical stage, and color-coded duplex sonography were performed at discharge and 1, 3, 6, 12, and 18 months thereafter. Primary endpoints of the study were immediate technical and clinical success and 1-year patency. RESULTS: Initial technical success was achieved in all patients. In 10 patients (27%), more than one 40-mm-long device had to be implanted for total lesion coverage; in three patients (8.1%), stents were placed in two separate segments of the SFA simultaneously. The total number of stents deployed was 50. Stent placement induced an initial improvement of the ABI from 0.54 plus minus 0.2 to 0.92 plus minus 0.11 (P <.01). Follow-up data for 12 months after treatment are available for 29 of 37 patients (78.4%); mean follow-up is 15.6 months (range, 1-26 mo). Primary patency rates at 6 and 12 months were 97.1% (SE = 2.9) and 86.2% (SE = 6.5). The primary assisted patency rate was 100% at 12 months. CONCLUSION: Endovascular placement of the IntraCoil self-expanding nitinol coil stent for salvage of failed angioplasty in patients with femoropopliteal obstructive disease is an effective and safe procedure with promising mid-term results.

Adult↗

In vitro effectiveness of mechanical thrombectomy devices for large vessel diameter and low-pressure fluid dynamic applications.

PURPOSE: To determine in vitro the efficacy of clot removal of the AngioJet (AJ; new 6-F generation), Hydrolyser (HL; 6-F), and Oasis (OS; 6-F) hydrodynamic thrombectomy devices and the Amplatz Thrombectomy Device fragmentation catheter (ATD; 8-F and new-generation 7-F) in large-diameter vessels and low-pressure fluid dynamic applications (ie, pulmonary embolism). MATERIALS AND METHODS: Thrombectomy of clots (N = 60; n = 12 for each tested device) created from 5-day-old porcine blood (16 g) was performed with the AJ (with coaxial 0.035-inch guide wire), HL, OS, and ATD in a bench-top model simulating low-pressure fluid dynamics (pulsed flow, 1,250 L/min). Tubes made of silicone (20-mm inner diameter) containing thrombus simulated a large-diameter vessel. The effluent was passed through a three-step filter system (10-1,000 micro m; pressure drop, 15 mm Hg). RESULTS: Mean thrombectomy time ranged from 83 seconds (7-F ATD) to 185 seconds (OS; P <.0001 compared to all). Remaining thrombus ranged from 5.4 g/32.7% (AJ) to 11.1 g/68.1% (HL; P <.001 compared to all). The AJ's fluid balance was 0.92, whereas the mean ratio of applied saline solution to aspirated fluid for the other devices were significantly different than isovolumetric conditions (HL, 0.64; OS, 0.59; P <.0001 compared to AJ). The AJ (0.36%), HL (0.43%), and OS (0.38%) caused the least overall emboli larger than 10 micro m; the ATD (7-F, 0.82%; 8-F, 0.74%) caused the most (P <.001 for both). CONCLUSIONS: The tested mechanical thrombectomy devices showed performance differences in thrombectomy time, efficacy of thrombus removal, and peripheral embolization rates. Based on low embolization rates for all devices tested, the experimental data indicate that the 7-F ATD and the 0.035-inch guide-wire-compatible AJ showed feasibility advantages for thrombectomy in large vessel diameter and low-pressure fluid dynamic applications.

Animals↗

Characterization of the integrity of three-dimensional trabecular bone microstructure by connectivity and shape analysis using high-resolution magnetic resonance imaging in vivo.

Bone mineral density and bone structure are the main determinants of bone strength in osteoporosis. In this study we used high-resolution magnetic resonance imaging to visualize the bone microstructure in the finger phalanges in vivo and to assess the topological three-dimensional connectivity of the trabecular network and the shape of the trabeculae as measures of bone quality. We visualized the phalanges of young and elderly healthy volunteers in vivo with a spatial resolution of 152 microm x 152 microm x 280 microm. Image processing software to quantify three measures of connectedness was developed and tested: connectivity, global connectivity density, and local connectivity density. Global three-dimensional connectivity ranged from 904 to 1,607 connections. Global connectivity density ranged from 2.9 to 4.7 connections per mm with large intersubject differences. We found a decrease of local connectivity density with growing distance from the joint ranging from 5.1 to 0.2 connections per mm. These preliminary results represent a quantitative description of the well-known rarefication of the trabecular network when moving from epiphysis to the diaphysis. Three-dimensional visualization showed a dense network consisting mostly of rod-like trabeculae at the epiphysis changing to a less dense network of a few plate-like structures near the medullary canal. An algorithm for the quantitative classification of trabecular architecture with regard to plate or rod-like shape was tested for feasibility. We conclude that in vivo assessment of three-dimensional properties of the trabecular network is possible in human phalanges. Determination of connectivity and shape will allow quantification of structural aspects of osteoporotic changes and may improve assessment of fracture risk.

Adult↗

Experience on endothelial cell adhesion on vascular stents and stent-grafts: first in vitro results.

RATIONALE AND OBJECTIVES: To evaluate endothelial cell (EC) attachment on different stents and stent-grafts combined with different coating materials. MATERIALS AND METHODS: Three segments (approximately 1cm(2) each) of Cragg-, Memotherm-, Palmaz-, Strecker-, and Wall-stents, uncovered or covered with polytetrafluoroethylene (PTFE), polyurethane (PU) or polyester (Dacron) were precoated with fibronectin and seeded in vitro under steady conditions with 2 x 10(5) human venous EC/cm(2) for 2 days. EC attachment and morphology was assessed by scanning electron microscopy. RESULTS: Superior EC attachment on uncovered stents was seen on Memotherm-, Palmaz-, and Wall-stent. On uncovered Cragg- and Strecker-stent only a few single and rounded EC could be detected. PTFE-covering lead to an equal or decreased EC coverage in comparison with the uncovered prostheses. An increase in EC coverage on PU-covered stents was seen and on polyester covered stents as compared with uncovered stents. CONCLUSION: In vitro, EC attachment is clearly different on vascular stents and stent-grafts, probably depending on the material of the stents stent and unknown manufacturing related components. When EC adhesion is desired and stent covering is used, the choice of covering material may influence EC adhesion.

Cell Adhesion↗

Comparison and modification of two cerebral protection devices used for carotid angioplasty: in vitro experiment.

The effectiveness of two basic cerebral protection devices designed for carotid angioplasty with and without additional aspiration techniques was compared in an in vitro model. During carotid angioplasty, embolization was simulated by injecting polyvinyl alcohol particles of different sizes into the model system. None of the tested devices, all of which were positioned in the internal carotid artery, was able to completely prevent embolization. In the internal carotid artery, the rate of particle capture did not vary among protection devices. However, embolization into the external carotid artery was more frequent with use of the GuideWire, as compared with that with use of the Angioguard.

Angioplasty, Balloon↗