Search PubMed⌕ Search

Biomedical subjects

Mark J Schnitzer

Publications and source records attributed to Mark J Schnitzer.

12 recordsLinked to original sources

Next-generation optical technologies for illuminating genetically targeted brain circuits.

Emerging technologies from optics, genetics, and bioengineering are being combined for studies of intact neural circuits. The rapid progression of such interdisciplinary "optogenetic" approaches has expanded capabilities for optical imaging and genetic targeting of specific cell types. Here we explore key recent advances that unite optical and genetic approaches, focusing on promising techniques that either allow novel studies of neural dynamics and behavior or provide fresh perspectives on classic model systems.

Animals↗

Fast-scanning two-photon fluorescence imaging based on a microelectromechanical systems two- dimensional scanning mirror.

Towards overcoming the size limitations of conventional two-photon fluorescence microscopy, we introduce two-photon imaging based on microelectromechanical systems (MEMS) scanners. Single crystalline silicon scanning mirrors that are 0.75 mm x 0.75 mm in size and driven in two dimensions by microfabricated vertical comb electrostatic actuators can provide optical deflection angles through a range of approximately16 degrees . Using such scanners we demonstrated two-photon microscopy and microendoscopy with fast-axis acquisition rates up to 3.52 kHz.

Computer Systems↗

In vivo imaging of mammalian cochlear blood flow using fluorescence microendoscopy.

AIMS: We sought to develop techniques for visualizing cochlear blood flow in live mammalian subjects using fluorescence microendoscopy. BACKGROUND: Inner ear microcirculation appears to be intimately involved in cochlear function. Blood velocity measurements suggest that intense sounds can alter cochlear blood flow. Disruption of cochlear blood flow may be a significant cause of hearing impairment, including sudden sensorineural hearing loss. However, inability to image cochlear blood flow in a nondestructive manner has limited investigation of the role of inner ear microcirculation in hearing function. Present techniques for imaging cochlear microcirculation using intravital light microscopy involve extensive perturbations to cochlear structure, precluding application in human patients. The few previous endoscopy studies of the cochlea have suffered from optical resolution insufficient for visualizing cochlear microvasculature. Fluorescence microendoscopy is an emerging minimally invasive imaging modality that provides micron-scale resolution in tissues inaccessible to light microscopy. In this article, we describe the use of fluorescence microendoscopy in live guinea pigs to image capillary blood flow and movements of individual red blood cells within the basal turn of the cochlea. METHODS: We anesthetized eight adult guinea pigs and accessed the inner ear through the mastoid bulla. After intravenous injection of fluorescein dye, we made a limited cochleostomy and introduced a compound doublet gradient refractive index endoscope probe 1 mm in diameter into the inner ear. We then imaged cochlear blood flow within individual vessels in an epifluorescence configuration using one-photon fluorescence microendoscopy. RESULTS: We observed single red blood cells passing through individual capillaries in several cochlear structures, including the round window membrane, spiral ligament, osseous spiral lamina, and basilar membrane. Blood flow velocities within inner ear capillaries varied widely, with observed speeds reaching up to approximately 500 microm/s. CONCLUSION: Fluorescence microendoscopy permits visualization of cochlear microcirculation with micron-scale optical resolution and determination of blood flow velocities through analysis of video sequences.

Animals↗

In vivo brain imaging using a portable 3.9 gram two-photon fluorescence microendoscope.

We introduce a compact two-photon fluorescence microendoscope based on a compound gradient refractive index endoscope probe, a DC micromotor for remote adjustment of the image plane, and a flexible photonic bandgap fiber for near distortion-free delivery of ultrashort excitation pulses. The imaging head has a mass of only 3.9 g and provides micrometer-scale resolution. We used portable two-photon microendoscopy to visualize hippocampal blood vessels in the brains of live mice.

Animals↗

Statistical kinetics of macromolecular dynamics.

Fluctuations in biochemical processes can provide insights into the underlying kinetics beyond what can be gleaned from studies of average rates alone. Historically, analysis of fluctuating transmembrane currents supplied information about ion channel conductance states and lifetimes before single-channel recording techniques emerged. More recently, fluctuation analysis has helped to define mechanochemical pathways and coupling ratios for the motor protein kinesin as well as to probe the contributions of static and dynamic disorder to the kinetics of single enzymes. As growing numbers of assays are developed for enzymatic or folding behaviors of single macromolecules, the range of applications for fluctuation analysis increases. To evaluate specific biochemical models against experimental data, one needs to predict analytically the distribution of times required for completion of each reaction pathway. Unfortunately, using traditional methods, such calculations can be challenging for pathways of even modest complexity. Here, we derive an exact expression for the distribution of completion times for an arbitrary pathway with a finite number of states, using a recursive method to solve algebraically for the appropriate moment-generating function. To facilitate comparisons with experiments on processive motor proteins, we develop a theoretical formalism for the randomness parameter, a dimensionless measure of the variance in motor output. We derive the randomness for motors that take steps of variable sizes or that move on heterogeneous substrates, and then discuss possible applications to enzymes such as RNA polymerase, which transcribes varying DNA sequences, and to myosin V and cytoplasmic dynein, which may advance by variable increments.

Algorithms↗

Retinal coding of visual scenes -- repetitive and redundant too?

Visual information reaches the brain by way of a fine cable, the optic nerve. The million or so axons in the optic nerve represent an information bottleneck in the visual pathway-where the fewest number of neurons convey the visual scene. It has long been thought that to make the most of the optic nerve's limited capacity the retina may encode visual information in an optimally efficient manner. In this issue of Neuron, Puchalla et al. report a test of this hypothesis using multielectrode recordings from retinal ganglion cells stimulated with movies of natural scenes. The authors find substantial redundancy in the retinal code and estimate that there is an approximately 10-fold overrepresentation of visual information.

Animals↗

Fiber-optic fluorescence imaging.

Optical fibers guide light between separate locations and enable new types of fluorescence imaging. Fiber-optic fluorescence imaging systems include portable handheld microscopes, flexible endoscopes well suited for imaging within hollow tissue cavities and microendoscopes that allow minimally invasive high-resolution imaging deep within tissue. A challenge in the creation of such devices is the design and integration of miniaturized optical and mechanical components. Until recently, fiber-based fluorescence imaging was mainly limited to epifluorescence and scanning confocal modalities. Two new classes of photonic crystal fiber facilitate ultrashort pulse delivery for fiber-optic two-photon fluorescence imaging. An upcoming generation of fluorescence imaging devices will be based on microfabricated device components.

Animals↗

In vivo mammalian brain imaging using one- and two-photon fluorescence microendoscopy.

One of the major limitations in the current set of techniques available to neuroscientists is a dearth of methods for imaging individual cells deep within the brains of live animals. To overcome this limitation, we developed two forms of minimally invasive fluorescence microendoscopy and tested their abilities to image cells in vivo. Both one- and two-photon fluorescence microendoscopy are based on compound gradient refractive index (GRIN) lenses that are 350-1,000 microm in diameter and provide micron-scale resolution. One-photon microendoscopy allows full-frame images to be viewed by eye or with a camera, and is well suited to fast frame-rate imaging. Two-photon microendoscopy is a laser-scanning modality that provides optical sectioning deep within tissue. Using in vivo microendoscopy we acquired video-rate movies of thalamic and CA1 hippocampal red blood cell dynamics and still-frame images of CA1 neurons and dendrites in anesthetized rats and mice. Microendoscopy will help meet the growing demand for in vivo cellular imaging created by the rapid emergence of new synthetic and genetically encoded fluorophores that can be used to label specific brain areas or cell classes.

Animals↗

Fiber optic in vivo imaging in the mammalian nervous system.

The compact size, mechanical flexibility, and growing functionality of optical fiber and fiber optic devices are enabling several new modalities for imaging the mammalian nervous system in vivo. Fluorescence microendoscopy is a minimally invasive fiber modality that provides cellular resolution in deep brain areas. Diffuse optical tomography is a non-invasive modality that uses assemblies of fiber optic emitters and detectors on the cranium for volumetric imaging of brain activation. Optical coherence tomography is a sensitive interferometric imaging technique that can be implemented in a variety of fiber based formats and that might allow intrinsic optical detection of brain activity at a high resolution. Miniaturized fiber optic microscopy permits cellular level imaging in the brains of behaving animals. Together, these modalities will enable new uses of imaging in the intact nervous system for both research and clinical applications.

Animals↗

Multiphoton endoscopy.

Despite widespread use of multiphoton fluorescence microscopy, development of endoscopes for nonlinear optical imaging has been stymied by the degradation of ultrashort excitation pulses that occurs within optical fiber as a result of the combined effects of group-velocity dispersion and self-phase modulation. We introduce microendoscopes (350-1000 microm in diameter) based on gradient-index microlenses that effectively eliminate self-phase modulation within the endoscope. Laser-scanning multiphoton fluorescence endoscopy exhibits micrometer-scale resolution. We used multiphoton endoscopes to image fluorescently labeled neurons and dendrites.

Animals↗

Multineuronal firing patterns in the signal from eye to brain.

Population codes in the brain have generally been characterized by recording responses from one neuron at a time. This approach will miss codes that rely on concerted patterns of action potentials from many cells. Here we analyze visual signaling in populations of ganglion cells recorded from the isolated salamander retina. These neurons tend to fire synchronously far more frequently than expected by chance. We present an efficient algorithm to identify what groups of cells cooperate in this way. Such groups can include up to seven or more neurons and may account for more than 50% of all the spikes recorded from the retina. These firing patterns represent specific messages about the visual stimulus that differ significantly from what one would derive by single-cell analysis.

Action Potentials↗