Search PubMed⌕ Search

Biomedical subjects

Marie-Claire Hennion

Publications and source records attributed to Marie-Claire Hennion.

18 recordsLinked to original sources

Molecularly imprinted polymers for the clean-up of a basic drug from environmental and biological samples.

A molecularly imprinted polymer (MIP) was synthesized and evaluated to selectively extract an alpha-blocker, i.e. alfuzosin, from human plasma. The synthesis of the MIP was performed in dichloromethane with methacrylic acid as monomer and the target drug as template. A first series of experiments was carried out in dichloromethane to estimate the potential of the MIP in its specific recognition medium, i.e. dichloromethane, by developing a selective procedure and by measuring the capacity of the sorbent. An optimized procedure was developed for the selective extraction of alfuzosin with a recovery close to 100% in this medium and a specific capacity of 1.3 micromol g(-1) of MIP was measured. A study in aqueous media was also carried out by a comprehensive approach of the retention mechanism in order to build a selective procedure of extraction. The effects of the amount and of the charge of cations were studied and an optimal pH value was defined to limit matrix effects. Then, the alfuzosin MIP was then directly used to selectively extract the target drug from human plasma with an extraction recovery of 60%. Lastly, a soil was extracted by a pressurized solvent and the resulting extract was cleaned up on the MIP, showing the possibility to use this selective sorbent for the sample treatment of various complex matrices.

Adrenergic alpha-Antagonists↗

Evaluation of reversed phase columns designed for polar compounds and porous graphitic carbon in "trapping" and separating neurotransmitters.

Quantification of neurotransmitters as biologically active analytes in neurological samples is of high interest for studying their effect on multiple targets. This work is part of a strategy involving two-dimensional liquid chromatography (2D LC) system with mass spectrometry (MS) detection. The concept of the on-line LC system is the coupling of reversed phase liquid chromatography (RPLC, the second separation dimension) to ion-exchange chromatography (IEC, the first dimension). Our objective in this study is to find the appropriate second dimension column, ensuring that samples of neurotransmitters are refocused and separated on it. Silica-based columns designed specifically to retain polar compounds were tested in LC conditions and compared with results obtained with a porous graphitic carbon (PGC, Hypercarb) column. These polar embedded, polar endcapped, and high-density alkyl chain columns successfully separated analytes in question using mobile phase systems with high percentage of water, or even pure water. Only Hypercarb column provided efficient retention of the most polar neurotransmitters and could be used for trapping and preconcentrating the compounds without rapid breakthrough.

Chromatography, Ion Exchange↗

Feasibility study of a reference material for water chemistry: long term stability of triazine and phenylurea residues stored in vials or on polymeric sorbents.

Matrix Reference Materials (MRM) are essential tools for the validation of analytical protocols. Nowadays, there are no such materials for the determination of herbicides in water. So, a feasibility study of a MRM for the analysis of triazines and phenylureas in water was carried out. Different kinds of candidates MRM were prepared: solutions of pesticides diluted in acetonitrile and stored in sealed vials or stored at the dry state after the evaporation of the solvent to dryness, pesticides stored on two different types of polymeric solid-phase extraction (SPE) sorbents after the percolation of drinking or river waters spiked with pesticides. The stability of these candidates MRM stored at various temperatures (room temperature, 0.5 degrees C or -18 degrees C) was studied over a period of approximately 1 year. Two different levels of concentration were studied for each kind of material. During the storage, some samples of each different MRM candidate were monthly analyzed by liquid chromatography. Results showed that, among the candidate materials, some of them presented satisfactory enough stability to consider a further certification. They were either pesticides in solution in sealed vials or pesticides stored on cartridges after the percolation of spiked water samples. However, it was shown that these different MRM candidates had to be stored at a temperature lower than 0.5 degrees C.

Chromatography, High Pressure Liquid↗

In situ synthesis of monolithic stationary phases for electrochromatographic separations: study of polymerization conditions.

Acrylate-based monolithic capillary columns were prepared from fused-silica capillaries using UV photopolymerization. The effect of the pretreatment of the capillary wall surface before polymerization was investigated and several procedures were compared. The columns were characterization by van Deemter curves and SEM imaging. The results indicated that a pre-silanization of the capillary wall in order to introduce methacrylate groups at the wall surface gave similar efficiencies but more homogeneous structures than when the silanization agent was introduced in the polymerization mixture. The conditioning of the capillary before silanization, especially the conditions of basic rinsing was also an important factor. The effect of the dose of UV light that was applied for the polymerization had also been investigated. The results demonstrated that the irradiation energy is a critical parameter. The minimum energy threshold required to obtain a suitable monolith was 3 J/cm(2) and the maximum was around 12 J/cm(2). A higher energy destroys the monolith. Within the convenient range of energy, the columns had the same efficiency and a good structure as seen by SEM imaging. Using the optimized procedure for the pretreatment and an adequate energy, the column-to-column repeatability was found good (n = 12). The repeatability was obtained for the plate height at two velocity values, the retention factor and the electroosmotic mobility with RSD values below 10.

Acrylates↗

Selective immunoclean-up followed by liquid chromatography for the monitoring of a biomarker of exposure to polycyclic aromatic hydrocarbons in urine at the ng l-1 level.

A selective clean-up procedure using an immunosorbent (IS) was developed for the trace-level determination, in water and urine samples, of 3-benzo(a)pyrene-glucuronide (3-BP-G), a biomarker of exposure to carcinogenic polycyclic aromatic hydrocarbons (PAHs). First, three sorbents used for the immobilization of antibodies were evaluated for their ability to limit the risk of non-specific interactions and to provide a high bonding density. The best sorbent, i.e. sepharose, was used for the immobilization of two different monoclonal antibodies. The most specific antibody for 3-BP-G was applied to the selective extraction from urine providing a clean extract, an easy and reliable quantification by comparison with a classical SPE process. The sensitivity of the fluorescence associated with the selectivity of the IS provides a limit of detection up to 1.2 ng l(-1) in urine for 3-BP-G.

Animals↗

Loading capacity of carrier ampholytes--based buffers in capillary electrophoresis.

Narrow pH cuts of carrier ampholytes (CAs), originally designed for IEF, have been used as BGEs in CE. Their physicochemical properties, rather high buffering capacity and low conductivity, allow very efficient protein separations under high electric field strength. Due to their isoelectric properties, CA BGEs are expected to present a low ionic concentration and consequently a low loading capacity. In this study, we developed a simple method that allows the estimation of the loading capacity of a UV-absorbing BGE by CE. We first characterized in terms of loading capacity, classical ammediol-chromate UV-absorbing BGEs and a 10 mM histidine solution, a classical isoelectric buffer. Then, the loading capacity of four different CA-based BGEs has been assessed. Experimental results have shown that the CA-based buffers were presenting a rather high loading capacity, comparable to classical buffer ones and far higher than the one of the 10 mM histidine solution.

Buffers↗

Protein tryptic digests analyzed by carrier ampholyte-based capillary electrophoresis coupled to ESI-MS.

In this study, narrow pH cuts of carrier ampholytes have been used as buffers in CE for the analysis of protein tryptic digests. Their low conductivity allows very efficient separations under high electric field strength without inducing any significant Joule heating. In this study, the capabilities of narrow pH cuts of carrier ampholytes for the separation of protein tryptic digests have been assessed. Three proteins of different molecular masses have been studied: cytochrome C (horse heart), beta-lactoglobulin B (bovine) and human transferrin. Efficient, rapid and repeatable separations of the peptides resulting from the tryptic digestion have been achieved in this buffer. Moreover, the feasibility of the coupling of carrier ampholyte-based capillary electrophoresis with ESI-MS has been demonstrated through the study of the cytochrome C tryptic digest.

Ampholyte Mixtures↗

Transient isotachophoresis in carrier ampholyte-based capillary electrophoresis for protein analysis.

Transient ITP (t-ITP) has been used in carrier ampholyte-based CE (CABCE) to enhance the sensitivity of protein analysis. The characteristics of carrier ampholytes (CAs) narrow pH cuts-based buffers, when used as BGEs in CE are compatible with t-ITP requirements. Indeed, being the sole buffering species of such solutions, CAs impose a pH close to their pI. Thus, in these solutions, the CAs possess low electrophoretic mobility. As a consequence, by adding an ionic component with high electrophoretic mobility either in the studied sample or in the BGE, a t-ITP step can be generated. This has first been demonstrated for protein test mixtures. Then, the combination of t-ITP with CABCE has been applied to study a real sample, the bovine milk.

Ampholyte Mixtures↗

Multidimensional gas chromatography for the detailed PIONA analysis of heavy naphtha: hyphenation of an olefin trap to comprehensive two-dimensional gas chromatography.

A multidimensional method providing the composition of a heavy naphtha in paraffins, isoparaffins, olefins, naphthenes, and aromatics (PIONA) in the C8-C14 range is presented. The analytical set-up consists in a silver modified silica olefin trap on-line coupled to comprehensive two-dimensional gas chromatography (GC x GC). In this configuration, hydrocarbons are separated, in gaseous state, in two fractions, saturate and unsaturate, each fraction being subsequently analysed by GC or by GC x GC. The resolution between saturates and olefins was found to be improved compared to a single GC x GC run. The characterisation of the olefin trap highlights the benefits and the limits related to the use of that stationary phase as a double bond selective fractionation medium.

Alkanes↗

Carrier ampholytes-based capillary electrophoresis as an alternative to capillary zone electrophoresis in classical background electrolytes.

Carrier ampholytes (CAs), originally designed for isoelectric focusing (IEF), have been used as background electrolytes (BGE) in capillary zone electrophoresis (CZE). Their main electrophoretic properties, relatively high buffering capacity and low electric conductivity allowed fast (less than 2 min) and high efficient (500,000 theoretical plates/m) separation of a test mixture of proteins under very high electric field strength (more than 1000 V/cm). The results obtained in such buffers have been compared to those obtained in more classical sodium--phosphate and sodium--N-(2-hydroxyethyl)piperazine-N'-(2-ethanesulfonate) background electrolytes. High ionic strength classical buffers were necessary to achieve the separation of the proteins contained in the test mixture. This induced a significant Joule heating and temperature increase inside the capillary whereas a negligible Joule heat was produced in carrier ampholyte buffers even at the above electric field strength (higher than 1000 V/cm).

Buffers↗

Characterisation of middle-distillates by comprehensive two-dimensional gas chromatography (GC x GC): A powerful alternative for performing various standard analysis of middle-distillates.

The detailed characterisation of middle distillates is essential for a better understanding of reactions involved in refining process. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GC x GC) is a powerful tool for improving characterisation of petroleum samples. The aim of this paper is to compare GC x GC and various ASTM methods -- gas chromatography (GC), liquid chromatography (LC) and mass spectrometry (MS) -- for group type separation and detailed hydrocarbon analysis. Best features of GC x GC are demonstrated and compared to these techniques in terms of cost, time consumption and accuracy. In particular, a new approach of simulated distillation (SimDis-GC x GC) is proposed: compared to the standard method ASTM D2887 it gives unequal information for better understanding of conversion process.

Chromatography, Gas↗

Carrier ampholytes as potential buffers in electrophoresis: physico-chemical study.

Joule heating is a limiting factor when separating proteins in capillary zone electrophoresis (CZE). Low conductivity buffers, are required for high-speed separations. We investigated the use of carrier ampholytes (CA) as background electrolytes (BGE) in CZE. We prepared 25 "narrow pH cuts" of wide pH range (3-10) CA mixture in order to know if these fractions were suitable to be used as BGE in CZE. Each fraction was characterised by CZE analysis, giving an idea of its heterogeneity (number and relative abundance of molecular ampholytes). Conductivities and buffering capacities of each fraction have been also measured. Our conclusion is that "narrow pH cuts" of CA might be well suited buffers for electrophoretic separations.

Ampholyte Mixtures↗

Evaluation of a retention model in comprehensive two-dimensional gas chromatography.

Modeling the retention in comprehensive two-dimensional gas chromatography (GC x GC) was achieved using retention indices obtained in conventional GC. Predicted results were compared with experimental data obtained in the two-dimensional separation of a synthetic hydrocarbon mixture. This proved to be helpful in optimizing the operating conditions of GC x GC separation of a complex petroleum sample and in identifying chemical families.

Chromatography, Gas↗

Comparison of conventional gas chromatography and comprehensive two-dimensional gas chromatography for the detailed analysis of petrochemical samples.

Comprehensive two-dimensional gas chromatography (GC x GC) has been investigated for the characterization of high valuable petrochemical samples from dehydrogenation of n-paraffins, Fischer-Tropsch and oligomerization processes. GC x GC separations, performed using a dual-jets CO2 modulator, were optimized using a test mixture representative of the hydrocarbons found in petrochemicals. For complex samples, a comparison of GC x GC qualitative and quantitative results with conventional gas chromatography (1D-GC) has demonstrated an improved resolution power of major importance for the processes: the group type separation has permitted the detection of aromatic compounds in the products from dehydrogenation of n-paraffins and from oligomerization, and the separation of alcohols from other hydrocarbons in Fischer-Tropsch products.

Chromatography, Gas↗

Immuno-based sample preparation for trace analysis.

Immuno-based sample preparation techniques are based upon molecular recognition. Thanks to the high affinity and high selectivity of the antigen-antibody interaction, they have been shown to be a unique tool in the sampling area. Immuno-based sample preparation methods include the widely encountered immunoaffinity extraction sorbents, so-called immunosorbents, as well as membrane-baed or ultrafiltration techniques. This review describes the new developments and applications that have occurred in recent years with emphasis on (i) the antigen-antibody interactions, (ii) and their importance for the properties and use of immunosorbents, (iii) multiresidue extractions, (iv) the on-line coupling to chromatographic or electrophoretic separations, and (v) the high potential for improving MS detection. The recent use of artificial antibodies for sample pretreatment, so-called molecularly imprinted polymers, is also described.

Antigen-Antibody Reactions↗

Experimental comparison of three monoclonal antibodies for the class-selective immunoextraction of triazines. Correlation with molecular modeling and principal component analysis studies.

The specificity of three immunosorbents (ISs) based on different monoclonal anti-triazine antibodies has been characterized by extraction recoveries studies and with step elution experiments. Both indicated that the anti-dichloroatrazine IS is specific of terbutylazine and cyanazine. The anti-atrazine IS is specific of the chlorotriazines, whereas the anti-ametryn IS can trap all the triazines. This confirms the great influence of the hapten design on the specificity of the resulting antibodies, even if the target molecules are small. Moreover, the anti-ametryn IS is suitable for class-selective extraction of triazines contained in complex matrices. An approach designed to learn more about the specificity for a group of structurally related compounds of antibodies produced with a given compound is proposed and evaluated. Molecular modeling followed by principal component analysis has been used to obtain distribution maps with the relative position of each immunoconjugate and all the triazines. In all three cases, conclusions on specificity made with the analysis of the maps fit well with the experimental results. Consequently, molecular modeling coupled with principal component analysis seems to be a unique, inexpensive, and rapid tool to select the appropriate hapten providing highly specific or class-specific antibodies according to the given problem.

Antibodies, Monoclonal↗

Simultaneous determination of "earthy-musty" odorous haloanisoles and their corresponding halophenols in water samples using solid-phase microextraction coupled to gas chromatography with electron-capture detection.

Certain haloanisoles present at trace levels cause a large part of earthy-musty off-flavor problems in drinking water. These potent odorous chemicals come mainly through biomethylation of their corresponding halopenols. To enable the investigation of both families of compounds, a method involving solid-phase microextraction (SPME) was developed and the main parameters governing SPME were optimized. This method allows the simultaneous quantification of haloanisoles and halophenols at levels ranging from 1 to 100 or 250 ng/l, with detection limits of about 0.5 ng/l and could be applied to potable as well as raw surface waters.

Anisoles↗

Preparation of antibodies and development of an enzyme-linked immunosorbent assay for determination of dealkylated hydroxytriazines.

The development of an indirect competitive enzyme-linked immunosorbent assay (ELISA) for dealkylated hydroxytriazines is reported here for the first time. The assay uses polyclonal antibodies raised against N-(4-amine-6-hydroxy-[1,3,5]triazin-2-yl)-4-aminobutanoic acid (hapten 2g) conjugated to keyhole limpet hemocyanin by the active ester method. The immunizing hapten was synthesized by first introducing the amino group to the triazine ring in a protected form in order to increase its solubility in organic media. Subsequent steps consisted of reacting this compound with an appropriate spacer arm, followed by removal of the protecting group in acidic media. The resulting assay uses a homologous competitor hapten coupled to conalbumin by the mixed anhydride method. Coating antigens prepared using a homologous covalent coupling procedure failed to produce competitive immunoassays. The assay tolerates media with high ionic strength (up to 70 mS cm(-)(1)) and basic pH values (7.5-9.5 units). Under the optimized conditions, this ELISA is specific for dealkylated hydroxytriazines, reaching suitable limits of detection.

Animals↗