Search PubMed⌕ Search

Biomedical subjects

Manabu Ito

Publications and source records attributed to Manabu Ito.

30 records · Page 2Linked to original sources

Nonuniform concerted evolution and chloroplast capture: heterogeneity of observed introgression patterns in three molecular data partition phylogenies of Asian Mitella (saxifragaceae).

Interspecific hybridization is one of the major factors leading to phylogenetic incongruence among loci, but the knowledge is still limited about the potential of each locus to introgress between species. By directly sequencing three DNA regions: chloroplast DNAs (matK gene and trnL-F noncoding region), the nuclear ribosomal external transcribed spacer (ETS) region, and internal transcribed spacer (ITS) regions, we construct three phylogenetic trees of Asian species of Mitella (Saxifragaceae), a genus of perennials in which natural hybrids are commonly observed. Within this genus, there is a significant topological conflict between chloroplast and nuclear phylogenies and also between the ETS and the ITS, which can be attributed to frequent hybridization within the lineage. Chloroplast DNAs show the most extensive introgression pattern, ITS regions show a moderate pattern, and the ETS region shows no evidence of introgression. Nonuniform concerted evolution best explains the difference in the introgression patterns between the ETS region and ITS regions, as the sequence heterogeneity of the ITS region within an individual genome is estimated to be twice that of an ETS in this lineage. Significant gene conversion patterns between two hybridizing taxa were observed in contiguous arrays of cloned ETS-ITS sequences, further confirming that only ITS regions have introgressed bidirectionally. The relatively slow concerted evolution in the ITS regions probably allows the coexistence of multiple alleles within a genome, whereas the strong concerted evolution in the ETS region rapidly eliminates heterogeneous alleles derived from other species, resulting in species delimitations highly concordant with those based on morphology. This finding indicates that the use of multiple molecular tools has the potential to reveal detailed organismal evolution processes involving interspecific hybridization, as an individual locus varies greatly in its potential to introgress between species.

Asia↗

Iliac crest reconstruction with a bioactive ceramic spacer.

This study aimed to investigate the long-term clinical results of the apatite wollastonite-containing glass ceramic (AWGC) iliac spacer and to discuss its efficacy in reconstruction of the bone graft donor site at the iliac crest. Thirty-one patients were studied for more than 10 years. All patients underwent anterior spinal fusion using autogenous tricortical iliac bone graft. After harvest of tricortical iliac bone graft, an AWGC iliac spacer ranging from 15 mm to 70 mm in length was press-fitted into the gap. Long-term clinical results were obtained from radiological and blood examinations. Thirty patients (97%) were satisfied with the spacer. There was new bone formation around the spacer on the radiograph. There was no abnormal silicon concentration in blood examinations. AWGC iliac spacer appears to be useful in the reconstruction of harvested iliac crest. New bone formation occurs, reducing the defect size.

Adolescent↗

A biomechanical analysis of metastatic vertebral collapse of the thoracic spine: a sheep model study.

STUDY DESIGN: This is a biomechanical study using sheep thoracic spine to investigate the probability of mechanical failure of the thoracic spine with various sizes or locations of tumor metastasis. OBJECTIVE: The objectives of this study were to investigate biomechanical effects of not only tumor sizes within the thoracic vertebral body but also its involvement of other spinal components on the probability of mechanical failures of the thoracic spine. SUMMARY OF BACKGROUND DATA: There have been no experimental studies concerning mechanical influences of destruction of costovertebral joint or posterior elements as well as vertebral body on the load-bearing capacity of the thoracic spine. METHODS: Ninety-nine fresh sheep thoracic spine specimens with ribs were used (T7-T9, T10-T12). Within vertebral bodies of 39 specimens, only trabecular defects were created in different sizes. In other 48 specimens, not only vertebral body defects that were 40% to the cross-sectional area of the vertebral body but also additional destruction of costovertebral joint, pedicle, and facet joint were created. All specimens were subjected to destructive biomechanical testing. RESULTS: The failure load decreased as the defect size in the vertebral body increased. A negative linear correlation was observed between the failure load and the size of vertebral body defect (r = 0.782). With 40% cross-sectional defect in the vertebral body, additional costovertebral joint destruction brought 25% reduction of the failure load, which was statistically significant. CONCLUSION: The load-bearing capacity of metastasized vertebrae in the thoracic spine was proportionally decreased when the defect size in the vertebral body increased. Destruction of costovertebral joint significantly increased the probability of vertebral collapse.

Animals↗

A retrospective radiographic analysis of subaxial sagittal alignment after posterior C1-C2 fusion.

STUDY DESIGN: Subaxial sagittal alignment following atlantoaxial (A-A) posterior fusion was investigated retrospectively in patients with A-A subluxation. OBJECTIVES: To evaluate the association between A-A fusion angle and postoperative subaxial sagittal alignment and to determine the optimal fusion angle for preservation of physiologic subaxial alignment. SUMMARY OF BACKGROUND DATA: A-A posterior fusion has been used for patients with A-A instability and provided satisfactory clinical results. However, there are patients showing unexpected development of subaxial kyphosis after surgery. The reasons for subaxial kyphosis after A-A fusion remain unclear. METHODS: Seventy-six patients with A-A subluxation who underwent several types of posterior A-A fusion were involved. There were 46 women and 30 men. The causes of A-A subluxation were rheumatoid arthritis in 47, trauma in 16, os odontoideum in 8, and unknown in 5. The methods of posterior fusion consisted of Magerl procedure with posterior wiring in 51, Brooks wiring in 18, and Halifax clamp in 7. Angles at C1-C2, C2-C7, and C1-C7 in the neural position were measured before surgery and at the final follow-up to find out any association between postoperative C2-C7 angle and the other radiologic parameters. The association between O-C1 range of motion and C2-C7 angle was also investigated. RESULTS: The mean angles of C1-C2, C2-C7, and C1-C7 before surgery were 18.4 degrees, 14.5 degrees, and 32.9 degrees, respectively. Those at the final follow-up were 26.0 degrees, 5.5 degrees, and 31.5 degrees, respectively. These results indicated that C1-C2 fixation in a hyperlordotic position led to a subaxial kyphosis after surgery. Statistics showed that there was a linear association between the C1-C2 lordotic fixation angle and the C2-C7 kyphotic angle. CONCLUSIONS: Surgical fixation of A-A joint in a hyperlordotic position will lead the lower cervical spine to a kyphotic sagittal alignment after surgery. To maintain the physiologic sagittal alignment of the subaxial cervical spine, C1-C2 should not be fixed in a hyperlordotic position.

Atlanto-Axial Joint↗

Local kyphosis reduces surgical outcomes of expansive open-door laminoplasty for cervical spondylotic myelopathy.

STUDY DESIGN: This retrospective study analyzed the effects of cervical alignment on surgical results of expansive laminoplasty (ELAP) for cervical spondylotic myelopathy (CSM). OBJECTIVE: To determine the limitation of posterior decompression by ELAP for CSM in the presence of local kyphosis. SUMMARY OF BACKGROUND DATA: Several studies have reported that cervical malalignment affected surgical outcomes of ELAP. However, there has been no report to demonstrate crucial determinants of surgical outcomes of ELAP for CSM in relation to cervical sagittal alignment. METHODS: The study group comprised 114 patients who underwent ELAP for CSM. All were followed up for more than 2 years. The Japanese Orthopedic Association (JOA) scoring system for cervical myelopathy (full score, 17 points) was used to evaluate surgical outcomes for each patient 2 years after surgery. Statistical analysis with multivariate logistic regression models was used to ascertain the risk factors affecting postoperative surgical outcomes. RESULTS: The average JOA scores were 9.9 points before surgery and 14 points 2 years after surgery. The recovery rate was 60.2%. Statistical analysis showed that signal intensity change on MRI and local kyphosis were the most crucial risk factors for poor surgical outcomes. Calculated with the logistic regression model, the highest risk of poor recovery was local kyphosis exceeding 13 degrees. CONCLUSIONS: The influence of cervical malalignment on neurologic recovery after ELAP for CSM was shown. When patients have local kyphosis exceeding 13 degrees, anterior decompression or posterior correction of kyphosis as well as ELAP should be considered. Expansive laminoplasty for CSM is best indicated for patients with local kyphosis less than 13 degrees.

Adult↗

Ingestion of difructose anhydride III and voluntary running exercise independently increase femoral and tibial bone mineral density and bone strength with increasing calcium absorption in rats.

Difructose anhydride III (DFAIII), a nondigestible disaccharide, promotes intestinal calcium absorption. Exercise-induced mechanical stimuli are essential for bone growth. In the present study, we examined the effects of consuming DFAIII and voluntary running exercise on calcium absorption and bone characteristics using male Sprague-Dawley rats (4 wk old). The study was designed in a 2 x 2 factorial arrangement with two conditions (sedentary or exercised) and two diets [AIN-93G diet with or without DFAIII (30 g/kg diet)]. Both consuming DFAIII and running exercise increased net calcium absorption, and the effects of DFAIII and exercise were additive. Both consuming DFAIII and exercise also increased femoral variables such as calcium content and total bone mineral density (BMD); however, only consuming DFAIII increased bone strength in the femur. Conversely, running exercise augmented tibial calcium content, total BMD and bone strength, but consuming DFAIII did not. We conclude that consuming DFAIII and running exercise additively enhance calcium absorption and differentially stimulate femoral and tibial BMD and mechanical properties in rats.

Absorption↗

In vitro biomechanical effects of reconstruction on adjacent motion segment: comparison of aligned/kyphotic posterolateral fusion with aligned posterior lumbar interbody fusion/posterolateral fusion.

OBJECT: Posterior lumbar interbody fusion (PLIF) was developed to overcome the limitations of posterolateral fusion in correcting spinal deformity and maintaining lumbar lordosis. In this study the authors compare the biomechanical effects of three different posterior reconstructions on the adjacent motion segment. METHODS: Ten calf spinal (L2-S1) specimens underwent nondestructive flexion-extension testing (+/- 6 Nm). The specimens were destabilized at the L5-S1 levels after intact testing. This was followed by pedicle screw fixation with and without interbody cages as follows: 1) with straight rods ("aligned" posterolateral fusion); 2) with kyphotically prebent rods ("kyphotic" posterolateral fusion); and 3) with interbody cages combined with straight rods ("aligned" PLIF/posterolateral fusion). The range of motion (ROM) of the operative segments, the intradiscal pressure (IDP), and longitudinal lamina strain in the superior adjacent segment (L4-5) were analyzed. The ROM associated with aligned PLIF/posterolateral fusion-treated specimens was significantly less than both the aligned and kyphotic posterolateral fusion-treated procedures in both flexion and extension loading (p < 0.05). The aligned PLIF/posterolateral fusion was associated with greater IDP and the lamina strain compared with the aligned and kyphotic posterolateral fusion groups in flexion loading. Under extension loading, greater IDP and lamina strain were present in the kyphotic posterolateral fusion group than in the aligned posterolateral fusion group. The highest IDP and lamina strain were shown in the aligned PLIF/posterolateral fusion group. CONCLUSIONS: Compared with kyphotic posterolateral fusion, PLIF may lead to even higher load at the superior adjacent level because of the increased stiffness of the fixed segments even if local kyphosis is corrected by PLIF.

Animals↗

Improved accuracy of computer-assisted cervical pedicle screw insertion.

OBJECT: The authors introduce a unique computer-assisted cervical pedicle screw (CPS) insertion technique used in conjunction with specially modified original pedicle screw insertion instruments. The accuracy of screw placement as well as surgery-related outcome and complication rates were compared between two groups of patients: those in whom a computer-assisted and those in whom a conventional manual insertion technique was used. METHODS: The screw insertion guiding system consisted of a modified awl, probe, tap and a screwdriver specially designed for a computer-assisted CPS insertion. Using this system, real-time instrument/screw tip information was three dimensionally identified in each step of screw insertion. Seventeen patients underwent CPS fixation in which a computer-assisted surgical navigation system was used. The cervical disorders consisted of spondylotic myelopathy with segmental instability or kyphosis, metastatic spinal tumor, rheumatoid spine, and postlaminectomy kyphosis. The rate of pedicle wall perforation was significantly lower in the computer-assisted group than that in the other group (1.2 and 6.7%, respectively; p < 0.05). The screw trajectory in the horizontal plane was significantly closer to the anatomical pedicle axis in the computer-assisted group compared with the manual insertion group (p < 0.05). This factor significantly reduced the incidence of screw perforation laterally. Complications such as neural damage or vascular injury were not demonstrated in the computer-assisted group (compared with 2% in the manual insertion treatment group). The overall surgery-related outcome was satisfactory. CONCLUSIONS: In contrast to the previously reported computer-assisted technique, our CPS insertion technique provides real-time three-dimensional instrument/screw tip information. This serves as a powerful tool for safe and accurate pedicle screw placement in the cervical spine.

Adolescent↗

Artificial intervertebral disc replacement using bioactive three-dimensional fabric: design, development, and preliminary animal study.

STUDY DESIGN: A new artificial intervertebral disc was developed, and its intrinsic biomechanical properties, bioactivity, and the effectiveness as a total disc replacement were evaluated in vitro and in vivo. OBJECTIVES: To introduce a new artificial intervertebral disc and to evaluate the in vitro mechanical properties, fusion capacity to bone, and segmental biomechanics in the total intervertebral disc replacement using a sheep lumbar spine. SUMMARY OF BACKGROUND DATA: The loss of biologic fusion at the bone-implant interface and prosthetic failures have been reported in previous artificial discs. There have been no clinically applicable discs with detailed experimental testing of in vivo mechanics and interface fusion capacity. METHODS: The artificial intervertebral disc consists of a triaxial three-dimensional fabric (3-DF) woven with an ultra-high molecular weight polyethylene fiber, and spray-coated bioactive ceramics on the disc surface. The arrangement of weave properties was designed to produce mechanical behavior nearly equivalent to the natural intervertebral disc. Total intervertebral disc replacement at L2-L3 and L4-L5 was performed using 3-DF disc with or without internal fixation in a sheep lumbar spine model. The segmental biomechanics and interface histology were evaluated after surgery at 4 and 6 months. RESULTS: The tensile-compressive and torsional properties of prototype 3-DF were nearly equivalent to those of human lumbar disc. The lumbar segments replaced with 3-DF disc alone showed a significant decrease of flexion-extension range of motion to 28% of control values as well as partial bony fusion at 6 months. However, the use of temporary fixation provided a nearly physiologic mobility of the spinal segment after implant removal as well as excellent bone-disc fusion at 6 months. CONCLUSION: An artificial intervertebral disc using a three-dimensional fabric demonstrated excellent in vitro and in vivo performance in both biomechanics and interface histology. There is a potential for future clinical application.

Animals↗

Complications related to hydroxyapatite vertebral spacer in anterior cervical spine surgery.

STUDY DESIGN: This is a report of complications related to the hydroxyapatite vertebral spacer used for anterior cervical reconstructive surgery. Compression of the spinal cord by broken fragments of hydroxyapatite spacer as well as its surrounding radiolucent clear zone were observed in seven patients. OBJECTIVES: To report complications related to the use of hydroxyapatite vertebral spacer for anterior cervical reconstructive surgery and to discuss how to prevent these complications. SUMMARY OF BACKGROUND DATA: Despite previous articles reporting the clinical applications of hydroxyapatite vertebral spacer for the cervical spine, clinical reports regarding the long-term results of hydroxyapatite spacer for anterior cervical surgery and its complications have been limited. METHODS: The authors reviewed patients who underwent anterior reconstructive surgery using the hydroxyapatite spacer at other hospitals and had postoperative complications related to hydroxyapatite spacer. RESULTS: Seven patients previously treated by anterior cervical spine surgery using the hydroxyapatite vertebral spacer were referred to the authors because of unsatisfactory surgical outcomes. All the patients had a radiolucent clear zone around the spacer and experienced severe neck pain. Four had fracture of the hydroxyapatite spacer, and two had compression of the spinal cord by retropulsed fragments of broken hydroxyapatite spacers. CONCLUSIONS: Although hydroxyapatite has been used in many medical fields because of its bioactive characteristics, its mechanical properties should be improved to lessen the risks of breakage and subsequent spinal cord compression. Gentle insertion maneuvers are also important to avoid the production of cracks inside the spacer.

Aged↗

Spinal cord compression by multistrand cables after solid posterior atlantoaxial fusion. Report of three cases.

The sublaminar wiring procedure has been commonly used for stabilizing the atlantoaxial complex. Multistrand braided cables were introduced in the early 1990s. In previous biomechanical studies these cables were demonstrated to be superior to monofilament wires in terms of their flexibility, mechanical strength, and fatigue-related characteristics. To the authors' knowledge, they are the first to describe clinically the occurrence of delayed spinal cord compression resulting from multistrand cables after the completion of rigid spinal arthrodesis in the upper cervical spine. Three patients underwent posterior atlantoaxial fusion in which two sublaminar multistrand cables were placed. Between 15 and 48 months postoperatively, they suffered from upper- and lower-extremity numbness as well as gait disturbance. Plain radiography and computerized tomography myelography revealed spinal cord compression caused by the sublaminar cables, although fusion was complete and physiological alignment was maintained at the fused segment. The radiographs obtained immediately after surgery demonstrated that the initial cable placement had been properly performed. The shape of the cable at the initial surgery was oval and then gradually became circular. The anterior arc of the circular shape of the cable in fact led to the spinal cord compression. Considering the mechanism of this late complication, a cable tends to spring open because of its high flexibility and becomes circular shaped even after the complete arthrodesis. When applying multistrand cables for intersegmental fixation at the atlantoaxial complex, delayed complications related to bowing of the cables is possible.

Adult↗