Search PubMed⌕ Search

Biomedical subjects

Manabu Ito

Publications and source records attributed to Manabu Ito.

At least 19 recordsLinked to original sources

Clinical outcome of posterolateral endoscopic surgery for pyogenic spondylodiscitis: results of 15 patients with serious comorbid conditions.

STUDY DESIGN: Clinical results of posterolateral endoscopic debridement and irrigation followed by percutaneous drainage for pyogenic spondylodiscitis were analyzed. OBJECTIVES: To report clinical results of transforaminal endoscopic surgery for pyogenic spondylodiscitis and to evaluate the effectiveness of this procedure in treatment of pyogenic spinal infections. SUMMARY OF BACKGROUND DATA: Pyogenic spinal infections have been increasing due to the development of medical treatment for patients with comorbid medical problems. Common treatments for spinal infections are administration of antibiotics or surgical debridement with bone grafts. There have been no reports, however, regarding the clinical outcome of posterolateral endoscopic treatment for pyogenic spinal infections. METHODS: Fifteen consecutive patients with pyogenic spondylodiscitis in the thoracic or lumbar spine were enrolled. Preoperative antibiotic treatment had failed in all the patients. The procedures consisted of posterolateral endoscopic debridement and irrigation followed by percutaneous drainage through single portal under the combination of local and intravenous anesthesia. Pain response using visual analog scale (VAS, 0-100 mm), inflammation parameters, and duration of antibiotic therapy were investigated. Radiologic evaluation focused on bony fusion, local kyphosis, disc height reduction, and abscess formation. RESULTS: All patients showed immediate pain reduction after surgery. Averaged VAS for pain was 86 before surgery and 25 at postoperative 1 week. Average of CRP was 4.00 mg/dL before surgery and 1.88 mg/dL at postoperative 1 week. Averaged duration of antibiotics therapy was 3.7 weeks. Spinal fusion was obtained in 13 patients. Two patients with neurologic deficits due to epidural abscess returned to normal. Preoperative psoas abscess in 6 patients disappeared after surgery on MRI. CONCLUSIONS: Posterolateral spinal endoscopic debridement and irrigation brought immediate pain reduction and good clinical results to patients who had comorbid medical problems and had pyogenic spondylodiscitis.

Adolescent↗

Palliative spinal reconstruction using cervical pedicle screws for metastatic lesions of the spine: a retrospective analysis of 32 cases.

STUDY DESIGN: A retrospective study. OBJECTIVES: To evaluate clinical outcomes of palliative spinal reconstruction using cervical pedicle screws in metastatic spine tumors. SUMMARY OF BACKGROUND DATA: No study to date has investigated the effectiveness of cervical pedicle screw fixation in metastatic lesions of the spine. METHODS: A total of 32 patients with metastatic spine tumors who underwent reconstructive surgery using cervical pedicle screws were reviewed. Four patients presented upper cervical lesions and 28 patients had subaxial lesions. All patients had intractable pain, 29 presented myelopathy, and 18 patients were nonambulatory. Combined anterior column reconstruction was considered in cases of life expectancy more than 2 years and anterior spinal cord compression that could not be solved by posterior decompression and kyphosis correction. Posterior fixation alone was performed in 25 patients, and posterior fixation combined with anterior column reconstruction was performed in 7 patients. RESULTS: The average postoperative survival period was 12.2 months. Neck pain was improved in all cases. Twenty-four (83%) of the 29 patients with spinal cord lesions presented neurologic improvement. Of 18 patients who were not ambulatory, 16 patients (89%) became ambulatory. Pain relief, neurologic function, and spinal stability were maintained throughout the survival period in 30 of 32 patients (94%). CONCLUSION: Spinal reconstruction using cervical pedicle screws improved spinal stability, pain, and neurologic function. These improvements were maintained throughout the survival period in 94% of the patients. Anterior column reconstruction could be avoided in 78% of the patients in spite of damaged anterior column.

Adult↗

Tumor-derived TGFbeta-1 induces dendritic cell apoptosis in the sentinel lymph node.

Lymphatic flux from a primary tumor initially flows into a tumor-draining lymph node (LN), the so-called sentinel LN (SLN). Carried by the lymph fluid are a variety of mediators produced by the tumor that can influence immune responses within the SLN, making it a good model with which to investigate tumor-related immunology. For instance, dendritic cell (DC) numbers are reduced in SLNs from melanoma and breast cancer patients. In the present study, we investigated the mechanism by which DC numbers were reduced within SLNs from patients with non-small cell lung cancer. We found that the incidence of apoptosis among DCs was higher in SLNs than in non-SLNs, as were levels of TGFbeta-1. In contrast, levels of TGFbeta-1 mRNA did not differ between SLNs and non-SLNs, but were 30 times higher in tumors than in either LN type. In vitro, incubation for 2 days with TGFbeta-1 induced apoptosis among both cultured DCs and DCs acutely isolated from normal thoracic LNs, effects that were blocked by the TGFbeta-1 inhibitor DAN/Fc chimera. Taken together, these results suggest that tumor-derived TGFbeta-1 induces immunosuppression within SLNs before the movement of tumor cells into the SLNs, thereby facilitating metastasis within those nodes.

Apoptosis↗

Multidirectional flexibility analysis of anterior and posterior lumbar artificial disc reconstruction: in vitro human cadaveric spine model.

The in vitro multidirectional flexibility analysis was conducted to investigate the initial biomechanical effect of biomimetic artificial intervertebral disc replacement from either anterior or posterior approach in a cadaveric lumbosacral spine model. Two designs of anterior total and posterior subtotal artificial discs were developed using bioactive three-dimensional fabric and bioresorbable hydroxyapatite/poly-l-lactide material (3DF disc). Both models were designed to obtain the stable interface bonding to vertebral endplates with maximum surface area occupation. Using seven cadaveric lumbosacral spines, the following three anterior reconstruction methods were sequentially performed at L4-5 level: anterior 3DF disc replacement; anterior BAK cages (BAK); and posterior pedicle screw fixation and anterior BAK cages combined (BAK + PS). The L2-3 level received two methods of posterior reconstructions: subtotal 3DF disc replacement (two implants), and posterior interbody cages and pedicle screw fixation (PLIF). Six unconstrained pure moments were applied and three-dimensional segmental motions were measured with an optoelectronic motion measurement system. The center of rotation (COR) calculation was conducted radiographically using flexion-extension films. Both anterior and posterior 3DF replacements statistically demonstrated equivalent range of motions (ROMs) in all loading modes compared to intact segment. Anterior BAK, BAK + PS, and PLIF demonstrated significantly lower ROMs when compared to intact and 3DF groups (P<0.05). The 3DF reconstruction tended to realign the COR to the posterior third or surrounding position at the operative disc level. The stand-alone lumbar 3DF disc replacement demonstrated biomechanical characteristics nearly equivalent to the intact spinal segments even through anterior or posterior approach in vitro, suggesting an excellent clinical potential.

Absorbable Implants↗

Giant cell tumor of the sternum.

A primary giant cell tumor (GCT) originating from the sternum is extremely rare. We report a case of a GCT originating from the sternum in a 45-year-old man who was referred to us for a mass in the anterior chest wall that had been growing slowly. Computed tomography revealed a soft tissue mass involving a large osteolytic and destructive lesion of the sternum body. Subtotal sternectomy and reconstruction with methylmethacrylate were performed. The tumor was 8.5 x 4.5 x 2.5cm, and the histopathological examination confirmed GCT. Radical wide resection of primary sternum tumors and reconstruction with an appropriately rigid prosthetic material are necessary to minimize local recurrence.

Bone Neoplasms↗

Intraoperative sentinel lymph node mapping using a new sterilizable magnetometer in patients with nonsmall cell lung cancer.

PURPOSE: We recently developed a novel method for sentinel lymph node mapping using magnetic force. However, problems with the sterility and sensitivity of the magnetometer made intraoperative sentinel lymph node mapping impossible. The purpose of this study was to test the utility of a new, more sensitive, sterilizable magnetometer developed in our institute for in vivo sentinel lymph node mapping in patients with nonsmall cell lung cancer. DESCRIPTION: Ferumoxides (magnetite) served as the tracer. Twenty patients with nonsmall cell lung cancer participated in the study. Each received 5 mL of ferumoxides, which were injected around their tumor. Magnetic force was then measured intraoperatively using the new sterilizable magnetometer. EVALUATION: The in vivo sentinel lymph node detection rate was 80.0% (16 of 20). The accuracy, sensitivity, and false-negative rates were 100% (16 of 16), 100% (4 of 4) and 0% (0 of 12), respectively. Our preliminary study indicates that our new magnetometer enables in vivo sentinel lymph node mapping in patients with nonsmall cell lung cancer. CONCLUSIONS: This device safely and accurately detected sentinel lymph nodes in nonsmall cell lung cancer patients.

Aged↗

Radiological risk factors of pseudoarthrosis and/or instrument breakage after PLF with the pedicle screw system in isthmic spondylolisthesis.

OBJECTIVE: Several studies have reported favorable results of posterolateral fusion (PLF) with pedicle screw systems (PSs) for isthmic spondylolisthesis. However, the best indication and limitations of this method still remain unclear. The present study aimed to analyze the radiological risk factors of pseudoarthrosis and/or instrumentation failure after PLF with PSs in isthmic spondylolisthesis, and to determine the limitations of this method. METHODS: The study group comprised of 101 patients with isthmic spondylolisthesis who underwent PLF with PSs. Follow-up was performed for more than 5 years. Statistical analyses with multivariate logistic regression models were used to identify risk factors of pseudoarthrosis and/or instrument failures associated with PLF with PSs. RESULTS: Average follow-up was 8 years. Fusion rate was 95%. There were instrument breakage in 6 patients, and pseudoarthrosis in 5. Statistical analysis with a logistic regression model revealed that preoperative % disc height (odds ratio: 3.60 per 10%, P<0.01) and slip angle (odds ratio: 4.48 per 10 degrees kyphosis, P<0.05) were the most crucial risk factors of pseudoarthrosis and/or instrument breakage when performing PLF for isthmic spondylolisthesis. CONCLUSIONS: In conclusion, PLF with PSs provided satisfactory results with high fusion rate. However, there were complications including pseudoarthrosis or instrument breakage in specific conditions. Preserved disc height and presence of segmental kyphosis were risk factors of these complications. Statistically, % disc height within 20% without segmental kyphosis was the best indication for PLF with PSs.

Adult↗

Biomechanical study on the effect of five different lumbar reconstruction techniques on adjacent-level intradiscal pressure and lamina strain.

OBJECT: The objectives of this study were to compare the biomechanical effects of five lumbar reconstruction models on the adjacent segment and to analyze the effects of three factors: construct stiffness, sagittal alignment, and the number of fused segments. METHODS: Nondestructive flexion-extension tests were performed by applying pure moments to 10 calf spinal (L3-S1) specimens. One-segment (L5-6) or two-segment (L5-S1) posterior fusion methods were simulated: 1) one-segment posterolateral fusion (PLF); 2) one-segment PLF with interbody fusion cages (one-segment PLIF/PLF); 3) two-segment PLF; 4) two-segment PLIF/PLF; and 5) two-segment PLF in kyphosis (two-segment kyphotic PLF). The range of motion (ROM) of the reconstructed segments, intradiscal pressure (IDP), and lamina strain in the upper (L4-5) adjacent segment were analyzed. The ROM was significantly decreased in the PLIF/PLF models compared with that in the PLF alone models after both the one- and two-segment fusions. If the number of fused segments was increased, the pressure and strains were also increased in specimens subjected to the PLIF/PLF procedure, more so than the PLF-alone procedure. In the one-segment PLIF/PLF model the authors observed a reduced IDP and lamina strain compared with those in the kyphotic two-segment PLF model despite the latter's higher levels of initial stiffness. CONCLUSIONS: If the number of fused levels can be reduced by using PLIF to correct local kyphosis, then this procedure may be valuable for reducing adjacent-segment degenerative changes.

Animals↗

Long-term follow up of surgical outcomes in patients with cervical disorders undergoing hemodialysis.

OBJECT: As increasing numbers of patients receive long-term hemodialysis, the number of reports regarding hemodialysis-related cervical spine disorders has also increased. However, there have been few reports summarizing the surgical results in patients with these disorders. The objective of this study was to evaluate the long-term follow up and clinical results after surgical treatment of cervical disorders in patients undergoing hemodialysis. METHODS: Seventeen patients in whom surgery was performed for cervical spine disorders while they received long-term hemodialysis therapy were enrolled in this study. Of these, 15 underwent follow-up review for more than 3 years after surgery, and these represent the study population. The remaining two patients died of postoperative sepsis. The average follow-up period was 120 months. Five patients without spinal instability underwent spinal cord decompression in which bilateral open-door laminoplasty was performed. Ten patients with destructive spondyloarthropathy (DSA) underwent reconstructive surgery involving pedicle screw (PS) fixation. In eight patients in whom posterior instrumentation was placed, anterior strut bone grafting was performed with autologous iliac bone to treat anterior-column destruction. Marked neurological recovery was obtained in all patients after the initial surgery. In the mobile segments adjacent to the site of previous spinal fusion, the authors observed progressive destructive changes with significant instability in four patients (40%) who underwent circumferential spinal fusion. No patients required a second surgery after laminoplasty for spinal canal stenosis without DSA changes. CONCLUSIONS: Cervical PS-assisted reconstruction provided an excellent fusion rate and good spinal alignment. During the long-term follow-up period, however, some cases required extension of the spinal fusion due to the destructive changes in the adjacent vertebral levels. Guidelines or recommendations to overcome these problems should be produced to further increase the survival rates of patients undergoing hemodialysis.

Adult↗

[Surgical treatment for osteoporotic spinal fractures in the thoraco-lumbar spine].

Most of osteoporotic spinal fractures can be successfully treated with conservative treatment. In some patients, however, conservative treatment is not effective and progressive vertebral collapse with neurological problems at thoraco-lumbar spine may occur. In this chapter, surgical indication and timing in patients with osteoporotic vertebral collapse are described. Surgical options including vertebroplasty, kyphoplasty, anterior reconstruction, posterior reconstruction, and combined anterior and posterior surgery are also described. The readers can understand both advantages and disadvantages of each surgical procedure. In senile patients, preoperative general conditions including comorbid medical problems should be taken into account to determine surgical treatments. Rigid and long spinal fusion using metal implants may lead to spinal fractures at adjacent vertebral bodies to the fused segments.

Aged↗

Increased expression of myosin light chain kinase mRNA is related to metastasis in non-small cell lung cancer.

BACKGROUND: The invasiveness of tumor cells depends in large part on their motility, which in turn depends on cytoskeletal function. A major cytoskeletal component involved in cell motility is myosin II, the classical form of myosin first identified in muscle but also expressed in nonmuscle cells. Myosin II is activated by myosin light chain kinase (MLCK), which phosphorylates it on its regulatory light chain. In this context, the contribution made by MLCK to tumor cell motility and invasiveness has been investigated extensively in vitro, but clinical evidence of such a contribution has been lacking. In the present study, therefore, we examined the role of MLCK in the metastasis of non-small cell lung cancer (NSCLC) in a clinical setting. METHODS: We measured MLCK mRNA expression in tumor samples from 39 NSCLC patients using real-time semiquantitative reverse transcription polymerase chain reaction carried out in a LightCycler. We then correlated MLCK mRNA expression with known clinicopathological factors. RESULTS: We found that levels of MLCK mRNA expression were higher in patients who showed disease recurrence and distant metastasis than in those who did not. Moreover, the 3-year disease-free survival rate among patients showing lower levels of MLCK mRNA expression [log10(MLCK/GAPDH) <1.4] was significantly greater than among those showing higher MLCK mRNA expression [log10(MLCK/GAPDH) > or =1.4] (87.5 vs. 50.0%; log-rank test, p = 0.021). CONCLUSION: These findings are the first clinical evidence that expression of MLCK is correlated with disease recurrence and distant metastasis in NSCLC.

Adult↗

An investigational study on the healing process of anterior spinal arthrodesis using a bioactive ceramic spacer and the change in load-sharing of spinal instrumentation.

STUDY DESIGN: Ceramic anterior lumbar interbody arthrodesis was performed using an in vivo sheep model. Observations of fusion status and the load-sharing of spinal instrumentation were studied at sequential intervals for 1 year after surgery. OBJECTIVES: To elucidate the healing process of spinal arthrodesis performed with a bioactive ceramic spacer and the change in load-sharing of anterior spinal instrumentation. SUMMARY OF BACKGROUND DATA: With the improved development of spinal instrumentation, anterior spinal arthrodesis has become a standard spinal reconstruction technique; however, the mechanistic basis underlying the healing process is not well documented. Moreover, it remains unclear how load-distribution through the fusion mass and spinal instrumentation change throughout the healing process. METHODS: Using 24 sheep, a two-level anterior lumbar interbody fusion (L2-L3, L4-L5) was performed using a smooth surface and a porous surface-modified bioactive ceramic, with each segment instrumented using a one-rod anterior spinal instrumentation system. Four animals each were killed at 2, 4, 8, 12, 24, and 52 weeks after surgery. Postmortem analysis included quantification of anterior rod strain under multidirectional flexibility testing and radiographic and histologic analyses of the arthrodesed segments. RESULTS: From 0 to 8 weeks after surgery, the bending strain of the rod gradually decreased despite no obvious bone formation. From 8 to 24 weeks after surgery, the rod strain markedly decreased with the development of bridging trabeculated bone formation between vertebral bodies. After 24 weeks after surgery, minimal changes were observed in rod strain; however, the fusion mass volumetrically increased with corresponding facet joint atrophy. The porous surface-modification of ceramic did not influence the histologic healing process, despite the improvement of interface osseous union rate. CONCLUSIONS: In anterior spinal arthrodesis, spinal instrumentation is mainly exposed to bending stress, with decreased load-sharing with corresponding development of the spinal fusion. Continuous bone remodeling of the anterior fusion mass results in concurrent decreases in spinal instrumentation and posterior spinal element load-transmission. The principal healing mechanism of ceramic anterior interbody spinal fusion is not an osseous union between the ceramic and vertebral body, but bridging bone formation around the ceramic, which directly connects the vertebral bodies above and below the disc.

Animals↗

A biomechanical and histological evaluation of a bioresorbable lumbar interbody fusion cage.

Novel spinal interbody fusion cages made of bioactive and bioresorbable composites by a unique forging process were developed. Previous in vitro study demonstrated that these cages marked excellent biomechanical values. The purpose of the present in vivo study was to evaluate the viability and advantage of this forged composite of uncalcined hydroxyapatite/poly L-Lactide (F-u-HA/PLLA) cage radiographically, biomechanically, and histologically, when compared to conventional autologous iliac bone (AIB) and carbon fiber cage (CFC). Twenty-five mature sheep underwent posterior lumbar interbody fusion at L2-3 level with pedicle screws system made of titanium. Three types of interbody fusion implants were grafted: AIB (n = 7), CFCs (n = 9), F-u-HA/PLLA cages (n = 9). Two types of cages were packed with autologous fragmented cancellous bone harvested locally. All animals were euthanized at 120 days after surgery. The fusion scoring using the coronal view CT scans was designed to three-dimensionally evaluate fusion quality within and around cages. The mean CT scores of three groups were 33.3 points, 35.0 points, and 33.6 points in AIB, CFC, and F-u-HA/PLLA cage groups, respectively (full-score: 56 points). Statistical differences were not detected among the three groups. The mean range of motion values among fused groups had no significant difference under all pure loadings. The range of motion showed strong and significant correlation with the CT fusion scores. Histologic results demonstrated that F-u-HA/PLLA cages contacted with the surrounding bone directly, and CFC was encircled with thick fibrous tissue layers without any sign of inflammation around cages. The fusion quality of fused spinal segment using F-u-HA/PLLA cages was equal to that of AIB or CFCs both radiographically and biomechanically. In the histological observation, biocompatibility of F-u-HA/PLLA cage was obviously superior to CFC. It has been confirmed that the novel bioactive and bioresorbable cages had valuable advantages over existing CFC for use in spinal reconstructive surgery.

Absorbable Implants↗

Intraoperative detection of lymph node micrometastasis with flow cytometry in non-small cell lung cancer.

OBJECTIVE: We sought to determine whether cytokeratin-positive cells can be detected as markers of lymph node metastasis by using flow cytometry within a time frame suitable for intraoperative decision making in non-small cell lung cancer. METHODS: Five lymph nodes from each of 20 patients with non-small cell lung cancer were randomly selected for study. Each node was divided longitudinally into 3 pieces: one piece for flow cytometry, one for immunohistochemical staining, and the last for conventional hematoxylin and eosin staining. In both flow cytometry and immunohistochemistry, cytokeratin-positive cells were detected with the fluorescein isothiocyanate-conjugated anti-cytokeratin antibody AE1/AE3. RESULTS: Cytokeratin-positive nodes were detected by means of flow cytometry within 40 minutes. Eight (8%) of the 100 lymph nodes from 4 (20%) of the 20 patients were deemed positive for metastasis on the basis of conventional histologic examination. By contrast, 33 (33%) lymph nodes from 13 (65%) patients were deemed positive on the basis of immunohistochemical cytokeratin staining, and 38 (38%) lymph nodes from 14 (70%) patients were deemed positive on the basis of flow cytometric cytokeratin-positive cell detection. All nodes deemed positive for metastasis on the basis of conventional and immunohistochemical methods were also positive on flow cytometry. CONCLUSIONS: Flow cytometry enables rapid intraoperative diagnosis of nodal metastasis in patients with non-small cell lung cancer. Flow cytometric detection of cytokeratin-positive cells within lymph nodes correlates with their immunohistochemical detection, and its level of sensitivity is greater than that of conventional histologic staining and about equal to that of immunohistochemical staining.

Biomarkers, Tumor↗

Multidirectional flexibility analysis of cervical artificial disc reconstruction: in vitro human cadaveric spine model.

OBJECT: This in vitro experimental study was conducted to investigate the initial biomechanical effect of artificial intervertebral disc replacement in the cervical spine. The multidirectional flexibility of replaced and adjacent spinal segments were analyzed using a cadaveric cervical spine model. METHODS: The following three cervical reconstructions were sequentially performed at the C5-6 level after anterior discectomy in seven human cadaveric occipitocervical spines: anterior artificial disc replacement with a bioactive three-dimensional (3D) fabric disc (FD); anterior iliac bone graft; and anterior plate fixation with iliac bone graft. Six unconstrained pure moments were applied with a 6-df spine simulator, and 3D segmental motions at the operative and adjacent segments were measured with an optoelectronic motion measurement system. The 3D FD group demonstrated statistically equivalent ranges of motion (ROMs) when compared with intact values in axial rotation and lateral bending. The 45% increase in flexion-extension ROM was demonstrated in 3D FD group; however, neutral zone analysis did not reach statistical significance between the intact spine and 3D FD. The anterior iliac bone graft and iliac bone graft reconstructions demonstrated statistically lower ROMs when compared with 3D FD in all loading modes (p < 0.05). The adjacent-level ROMs of the 3D FD group demonstrated nearly physiological characteristics at upper and lower adjacent levels. Excellent stability at the interface was maintained during the whole testing without any device displacement and dislodgment. CONCLUSIONS: The stand-alone cervical 3D FD demonstrated nearly physiological biomechanical characteristics at both operative and adjacent spinal segments in vitro, indicating an excellent clinical potential for cervical artificial disc replacement.

Bone Plates↗

Vertebral osteonecrosis associated with sarcoidosis. Case report.

Sarcoidosis is a systemic disease commonly affecting lung, skin, or eye. Sarcoidosis involved with osseous structures occurs in approximately 5% of patients, usually involving small bones. Spinal sarcoidosis is extremely rare. The authors report on a man in whom examination of a subclavicular lymph node biopsy specimen and its spinal involvement had established a diagnosis of sarcoidosis and who had undergone steroid therapy. Despite intensive conservative treatment, the authors observed progressive collapse of L-2 requiring spinal decompressive and reconstructive surgeries. Histological evaluation of the collapsed vertebra did not show the typical noncaseating granuloma; rather, the authors observed osteonecrosis of the entire L-2 structure without reactive cellular activities. Other potential diagnoses including infectious disease, metastatic spinal tumor, and osteoporotic vertebral collapse were excluded based on laboratory data, imaging studies, and pathological findings. Complete necrosis of the entire L-2 vertebra in this case can be considered as a rare clinical manifestation of spinal sarcoidosis. Because of osteopenia and systemic bone fragility, combined anterior-posterior spinal reconstructive surgery was performed to restabilize the severely damaged spine.

Diagnosis, Differential↗

Cervical spine injuries associated with lateral mass and facet joint fractures: new classification and surgical treatment with pedicle screw fixation.

To clarify the injury pattern, initial spinal instability, degree of discoligamentous injuries in cervical lateral mass and facet joint fractures, we retrospectively analyzed radiological parameters and introduced a new classification for these injuries. Surgical treatment was performed with cervical pedicle screw fixation (CPS), and overall neurological and radiological outcome was evaluated with a minimum follow-up period of 2 years. Lateral mass fractures were divided into the following four subtypes: separation, comminution, split, and traumatic spondylolysis. The sagittal and frontal alignments were evaluated at both mainly injured and adjacent spinal segments on radiographs. The initial discoligamentous injuries were investigated on magnetic resonance imaging in terms of their frequencies, subtype of injuries, and involved spinal levels. Anterior translation of fractured vertebra was demonstrated in 77% of lateral mass fractures, while 24% of anterior translation was observed, even in cephalad-adjacent vertebrae. On magnetic resonance imaging, signal changes in anterior longitudinal ligament (ALL) and intervertebral disc were demonstrated in 76% of caudal segments and 24% of cephalad segments adjacent to fractured vertebra of lateral mass fractures. The subtype analyses of lateral mass fractures demonstrated high rates of anterior translation in separation, split, and traumatic spondylolisthesis, as well as significant coronal malalignment in comminution and split types (p<0.05). Thirty-one patients underwent surgical treatments using a cervical pedicle screw fixation. The CPS provided the superior capability of deformity correction without pseudoarthrosis, as well as excellent neurological recovery. The average numbers of stabilized segments were minimized without serious complications. In separation, facet joint fracture, and fractures with mild lateral mass comminution, the single level posterior fixation can be considered. The significant unstable injuries of split and comminution type with coronal malalignment can be treated with exclusive two-level posterior stabilization with CPS. The initial evaluation of fracture subtypes helps to successfully minimize the stabilized spinal segment.

Adolescent↗