[CT scanner and the reliable limit of detection on intraocular foreign bodies (author's transl)].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Takao.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Two rare cases of strabismus resulting from contracture of the extraocular rectus muscles after retrobulbar anesthesia for cataract surgery are described. Clinical signs in both cases suggested that the development of the impaired function of the lateral and superior rectus muscles followed the same pattern: initial stimulation followed by paretic and restrictive stages. Abnormal enlargement of the muscles was identified by computed tomography (CT) and magnetic resonance imaging (MRI). The data indicate that the strabismus was the result of direct injection of anesthetics into the rectus muscle.
Explore the source record for details and available documents.
A case of twisted ovarian tumor with intravascular gas is presented, and the mechanism of the gas formation is discussed. On the basis of the probable mechanism of gas formation observed in dead fetuses, the gas seen in the present case is considered to have been oxygen released from trapped oxyhemoglobin within the tumor vessels. "Intravascular gas" within an ovarian tumor, although extremely rare, is diagnostic of ovarian torsion.
PURPOSE: The purpose of this study was to evaluate the utility of triphasic spiral CT with water-filling method in the preoperative T staging of gastric cancer. METHOD: We performed triphasic spiral CT in 108 patients with gastric cancer (53 with early and 55 with advanced gastric cancer). The CT findings were prospectively analyzed and correlated with the histopathologic findings. Spiral CT scans were assessed for the layered pattern of the normal gastric wall, the detectability of tumor, the enhancing pattern of the tumor, and the depth of tumor invasion. RESULTS: The layered pattern of the normal gastric wall was clearly demonstrated in the arterial-dominant or parenchymal phase. All 12 early cancers detected with spiral CT were most clearly depicted in the arterial-dominant or parenchymal phase. On the other hand, 15 (28%) of 54 advanced cancers were most clearly depicted in the equilibrium phase due to the gradual enhancement from the inner mucosal side of the tumor. Most of these tumors were scirrhous type tumor containing abundant fibrous tissue stroma. The accuracy of spiral CT for tumor detection and T staging was 98 and 82%, respectively, in advanced gastric cancer and 23 and 15%, respectively, in early gastric cancer. CONCLUSION: Spiral CT with triphasic scan technique improved the accuracy of estimating the depth of tumor invasion in advanced gastric cancer.
We assessed the histologic changes in donor and recipient bronchi from 15 dogs that had received a lung transplant and related these changes to the severity of acute rejection seen in the parenchyma of these same lungs. Minimal rejection was associated with no abnormal change in either the donor or the recipient bronchi. In mild lung rejection, mononuclear cell cuffings were seen around bronchial arteries in donor bronchial adventitia, although few mononuclear cell infiltrates were seen in the submucosa. Moderate lung rejection was associated with more prominent mononuclear cell cuffings in the donor bronchial adventitia and mucosal infiltrates of mononuclear cells in the membranous portion. In cases of severe lung rejection, the mononuclear cell infiltrates were also apparent in the cartilaginous portion of the donor bronchial mucosa. Moreover, submucosal edema and detachment of bronchial epithelium were seen. These histologic changes were not observed in the recipient bronchi during acute rejection, nor were they seen in the donor and the recipient bronchi during lung infection without rejection. They might, therefore, reflect acute rejection in the donor bronchus. These results might provide the histologic support for our previous observation of decreased bronchial mucosal blood flow measured by the laser Doppler flowmeter in relation with the extent of acute lung rejection.
Bronchial mucosal blood flow (BMBF) was measured with a laser-Doppler flowmeter in a canine model (n = 20), and the measurement was evaluated to see if it was a useful method for diagnosing allografted lung rejection. The ratio of the value of BMBF at the level of the donor second carina against that at the level of carina (the L/C ratio, an index of BMBF of donor bronchus) decreased in accordance with the extent of lung rejection, and it increased and entered the normal range with the reversal of lung rejection. Compared with the L/C ratio and the rejection grade by histologic changes in open-lung biopsy, the L/C ratio at grade 0 (latent phase) was 0.91 +/- 0.07; at grade Ia (early vascular phase), 0.86 +/- 0.05; at grade Ib (late vascular phase), 0.68 +/- 0.10; at grade II (early alveolar phase), 0.60 +/- 0.14; and at grade III (late alveolar phase), 0.50 +/- 0.15. A significant difference was noted between grades Ia and Ib (p less than 0.01) and between grades Ib and III (p less than 0.01). The sensitivity and the specificity in the detection of early rejection before grade Ib were 96% and 92%, with only one false-negative and two false-positives resulting from 51 measurements of BMBF. In three cases of serious lung infections, the L/C ratio did not fall, and the rejection could be distinguished from infection. These results suggest that measurement of the BMBF is useful for detecting the early rejection of transplanted lungs.
We investigated the relationship between the rejection of lung allografts and the bronchial mucosal blood flow with a laser flowmeter. Nineteen mongrel dogs underwent left lung allotransplantation and were given daily oral immunosuppressive therapy with azathioprine and cyclosporine. The bronchial mucosal blood flow at the carina and the bifurcation of left upper and lower bronchi were measured on days 14, 21, and 28 after left lung transplantation. The bronchial mucosal blood flow of the transplanted lungs was expressed as the ratio of bronchial mucosal blood flow at the bifurcation of left upper and lower bronchi to the bronchial mucosal blood flow at the carina (L/C ratio) instead of the absolute value because bronchial mucosal blood flow was affected by the depth of anesthesia of the dogs. We classified the histologic appearance of the transplanted lung tissue into one of five grades: 0, 1a, 1b, 2, and 3. No rejection was in grade 0, and as the rejection process progressed the higher grades were used in order. The mean L/C ratios for grades 0, 1a, 1b, 2, and 3 were 0.95 +/- 0.03, 0.82 +/- 0.05, 0.68 +/- 0.04, 0.58 +/- 0.07, and 0.30 +/- 0.07, respectively. Thus the L/C ratio decreased as the rejection process progressed. The histologic changes of the donor main bronchus in each rejection grade were investigated. Mononuclear cell infiltration and edema around the small vessels was seen in early rejection. These same histologic changes appeared in muscular arteries as rejection progressed, and the damage to the small vessels and muscular arteries was more severe in late rejection.(ABSTRACT TRUNCATED AT 250 WORDS)
To establish the differential diagnosis of repair cells from malignant cells, 624 repair cells from 11 cases, 547 cells derived from 8 adenocarcinomas and 593 cells from 8 squamous-cell carcinomas were analyzed, with stress on the morphology of the nucleoli. Such planimetric data as mean cellular areas, mean nuclear areas, mean nucleolar areas, nuclear-cytoplasmic ratios and nucleolar-nuclear ratios were fairly similar among the three cell groups. However, the even distribution of nucleoli in the nuclei, the decrease in C-type nucleoli and nucleoli consistently linked with nucleolus-associated chromatin were noted to be reliable criteria for the diagnosis of repair cells along with such well-known morphologic characteristics as the sheetlike arrangement of repair cells, the lack of isolated forms, the finely granular chromatin pattern and the round, smooth nuclear configuration with a thin nuclear membrane.
In this article, the clinical experience with a cardiopulmonary bypass (CPB) using a newly developed hollow fiber oxygenator with an ultra-thin layer of silicone is reported. A comparative study of biocompatibility between the new oxygenator and a heparin coated oxygenator is also described. The CPB was performed with a silicone coated oxygenator, Mera Excelung Binding Prim HPO 15 H-C (Group I, n = 6) or Binding Prim HPO 25 H-C (Group II, n = 10) (Senko Medical Instrument Mfg., Tokyo, Japan). Air could be vented through the silicone coated hollow fibers, and it was easy to prime the circuits. The CPB duration was 101 +/- 37 min and 170 +/- 64 min for Groups I and II, respectively. There were no deaths and no complications from CPB. Partial arterial pressure of O2 levels 60 minutes after the start of CPB were 529 +/- 28 mm Hg and 529 +/- 28 mmHg for Group I and II, respectively. Partial arterial pressure of CO2 levels 60 min after the start of CPB were 36.4 +/- 4.6 mmHg and 39.4 +/- 4.4 mmHg, respectively. Plasma free hemoglobin at 60 min was 33.5 +/- 17.2 mg/ dL and 46.7 +/- 26.1 mg/dL for Groups I and II, respectively. As an evaluation of biocompatibility, the effects of the new oxygenator on platelet activation (GP Ib, IIb/IIIa), coagulation (TAT), fibrinolysis (PIC), and inflammatory response (C3a, granulocyte elastase) were investigated during CPB and comparing to those of the heparin coated oxygenator. There were no significant differences in GP Ib, GP IIb/IIa, TAT, PIC, and granulocyte elastase between the two oxygenators. However, 60 min after the start of CPB, the C3a was significantly lower for the new oxygenator group than for the heparin coated oxygenator group (p < 0.03). The new oxygenator showed good gas transfer, low hemolysis, and good biocompatibility. Because of its durability and good biocompatibility, the new oxygenator was determined to be suitable for prolonged extra corporeal circulation.