Hemidiaphragm paralysis: CT diagnosis.

We describe the use of computed tomography (CT) in diagnosing and documenting diaphragmatic paralysis in a patient with right lung cancer that invaded the mediastinum. The patient was unable to breath hold during CT scanning, and the images were degraded by motion artifact. Motion artifact, however, was noted only in the left lung. In patients with suspected phrenic nerve dysfunction who are having chest CT for any reason, we suggest obtaining several dynamic images at the lung bases during forced exhalation. The lack of motion artifact in the lung parenchyma may be useful for diagnosing phrenic nerve injury and hemidiaphragm paralysis.

Artifacts↗

Panlobular pulmonary emphysema caused by i.v. injection of methylphenidate (Ritalin): findings on chest radiographs and CT scans.

OBJECTIVE: Recent reports have described severe precocious pulmonary emphysema in persons who inject methylphenidate (crushed Ritalin tablets) i.v. We retrospectively evaluated the plain radiographic and CT features in 21 such patients. MATERIALS AND METHODS: The chest radiographs, available CT scans, and clinical and pathologic data were reviewed in 21 cases of i.v. Ritalin use. The patients were from 35 to 54 years old. Twelve patients were men, and nine were women. Emphysema was graded on the basis of findings on chest radiographs, by consensus, on a four-point scale as absent, mild, moderate, or severe. CT scans were available for three patients, including one imaged after a single lung transplantation. Autopsy results were available for four patients. Fixed inflated lung specimens and corresponding high-resolution CT scans were available in three cases. RESULTS: Radiographs showed pulmonary emphysema in all cases. The distribution of disease was basilar and symmetric. Small apical bullae were suggested in only one case. Basilar emphysema was rated as mild in four patients, moderate in three patients, and severe in 14 patients. In 11 patients who had serial chest radiographs, the basilar emphysema was noted to progress over a 2- to 7-year period. No evidence of progressive massive fibrosis was seen in any patient. CT scans confirmed emphysema, most severe at the lung bases. CONCLUSION: The plain radiographic and CT findings in patients who inject Ritalin are similar to those found in patients with alpha 1-antitrypsin deficiency and different from the findings seen in other types of i.v. drug use. The finding of basilar pulmonary emphysema should alert the radiologist to the possibility of i.v. injection of Ritalin.

Adult↗

Integrating a personal-computer local-area network with a radiology information system: value as a tool for clinical research.

We investigated a method for increasing the utility of a radiology information system by connecting it to a personal-computer network and transferring radiologic data to a more user-friendly, familiar computing environment. We have developed a personal-computer local-area network that is linked to our radiology information system. Our software periodically transfers data from the radiology information system to a file server on our network that supports cross-platform access for Macintosh and IBM PC--compatible computers. Data are stored in formats compatible with inexpensive personal-computer software. These capabilities facilitate any research that requires a tailored, retrospective analysis of radiologic data. The need for ancillary personnel to perform paper-based searches or redundant data entry is decreased. Radiologists and administrators also have user-friendly access to information that might facilitate other projects dealing with education or analysis of clinical efficacy. The ever-growing power of personal computers, combined with inexpensive yet sophisticated software for these machines, frequently provides a more useful method for retrospective analysis of radiologic data than does a proprietary radiology information system running on a minicomputer.

Local Area Networks↗

CT of the lung in patients with pulmonary emphysema: diagnosis, quantification, and correlation with pathologic and physiologic findings.

Pulmonary emphysema is a pathologic diagnosis. However, the diagnosis can be made with relative certainty on the basis of clinical and radiologic criteria. The clinical diagnosis of emphysema can be difficult because correlations between results of lung function tests and the extent of emphysema are poor. Additionally, features of other obstructive lung diseases may overlap. From the clinician's standpoint, the main value of differentiating between emphysema and other obstructive diseases of the airways (e.g., asthma and chronic bronchitis) is to (1) establish a prognosis and (2) guide the use of corticosteroid therapy by defining the degree of reversibility that can be expected in patients with limitation in air flow.

Female↗

Small-airway diseases of the lungs: findings at expiratory CT.

CT performed in patients during suspended full expiration has recently been used to reveal a major physiologic consequence of airway diseases, particularly diseases of those smaller airways beyond the segmental branches: air trapping. Lung regions that retain air during exhalation (air trapping) remain more lucent than normal lung regions do. Detection of air trapping can provide clues to an otherwise unsuspected or underappreciated small-airway disease.

Adult↗

Computerized tracking of mammography patients: value of a radiology information system integrated with a personal-computer data base.

OBJECTIVE. We investigated the advantages of using a radiology information system as the primary data source for a mammographic patient-tracking system that is based on a personal-computer local-area network and that requires almost no data entry. HARDWARE AND SOFTWARE. Our mammographic data base is maintained on a file server that provides cross-platform access to both Macintosh and IBM-compatible personal computers. Locally developed software automatically transfers mammographic data from our radiology information system to the file server's mammographic data base. The data transferred include patients' demographics (e.g., hospital identification number, address, referring physician) and the complete mammographic report. With the use of specific terminology, the need for follow-up can be automatically gleaned from the mammographic report and coded within the data base. Graphically oriented, commercially available software provides easy access to this information from any personal computer on our department's network. The software provides considerable flexibility for searching and manipulating the data without the need for customized data-base programming. Redundant data entry and associated errors are drastically reduced, as are personnel requirements for maintaining the system. Relative to most commercial radiology information systems, a personal computer facilitates the steps involved in tracking patients and obtaining highly customized analyses of the mammographic data base. The data in the mammographic data base exactly match those in the hospital's registration data and are easily transferred to other personal-computer programs for ancillary processing. CONCLUSION. This technique is ideal for departments that use a general-purpose radiology information system for mammographic reporting, yet need a more powerful but user-friendly and low-cost method for tracking their mammography patients.

Female↗

A new method for computed tomography image compression using adjacent slice data.

RATIONALE AND OBJECTIVES: The authors developed and subjectively evaluated an interslice compression algorithm that explores the redundancy among adjacent slices of an x-ray computed tomography (CT) scan. This algorithm has been compared to an intraslice compression algorithm based on the two-dimensional discrete cosine transform. METHODS: Nine x-ray CT head images from three patients were compressed with this interslice method at compression ratios of 5:1, 10:1, and 15:1. The same images were also compressed with the intraslice method at the same ratios. Six radiologists judged quality of randomly selected compressed and decompressed images compared to that of the originals. The evaluation data were analyzed statistically with the analysis of variance and Tukey's multiple comparison. Kappa-like statistics (Williams index and O'Connell and Dobson indexes) were also calculated to measure the agreement among readers beyond the amount expected by chance. RESULTS: The interslice coding algorithm showed significantly better quality than the intraslice method at significance level 0.05, even though there was no difference in the objective distortion measure (signal-to-noise ratio). Also, the quality of 10:1 compressed images with the interslice coding algorithm was not significantly different from that of the originals at level 0.05. While large variations in agreement occurred among readers, the overall agreement was statistically significant. CONCLUSIONS: By using adjacent slice information in compressing x-ray CT images, significantly better quality in compressed and decompressed images was achieved. While 10:1 compressed images with the interslice algorithm were not significantly different from the originals in quality at level 0.05, effect on diagnostic accuracy remains to be investigated.

Algorithms↗

High-resolution computer display of portable, digital, chest radiographs of adults: suitability for primary interpretation.

OBJECTIVE: The suitability of using a high-resolution computer-display system for primary interpretation of adult chest radiographs obtained with portable apparatus and storage phosphor technology was evaluated with receiver operating characteristic analysis and subjective methods. MATERIALS AND METHODS: Sixty portable digital chest radiographs showing abnormalities that approached the resolution limits of our computed radiography system were selected. The original digital data making up the 2140 x 1760 x 10 bit images were transferred to a cathode ray tube (CRT) display system composed of two Megascan monitors. Postprocessing rendered two images, one for each monitor, to emulate the two-on-one hard-copy format produced by the computed radiography system. Each image set was interpreted independently by three radiologists experienced with hard-copy format. Limited level and window adjustments were allowed during CRT interpretation. For both CRT and hard-copy display, images were graded on the basis of the interpreter's confidence in the presence of pneumothorax and parenchymal abnormalities. Three types of foreign devices were subjectively analyzed: endotracheal tubes, nasogastric tubes, and temporary epicardial pacer wires. RESULTS: No significant differences were found in detecting pneumothorax or focal infiltrates. One radiologist found the hard copy better for detecting diffuse infiltrates (p = .02); two radiologists favored CRT for visualizing nasogastric tubes (p < .005, p < .02); and one radiologist favored CRT for visualizing temporary epicardial pacer wires (p = .05). CONCLUSION: We conclude that an optimized high-resolution CRT system is quite promising for primary interpretation of digital portable chest radiographs, but further investigation and greater statistical power are necessary to confirm our results.

Adult↗

Computerized mammography data base systems.

A computerized mammography data base system is a specialized radiology information system that is usually maintained on personal computers and is designed to facilitate the data processing tasks associated with mammography. This article is intended to assist readers in developing an organized approach to evaluating or designing a computerized mammography data base system, and to help in determining if such a system is feasible. Some initial decisions are necessary. Consideration should be given to how mammograms are currently processed in the department to be computerized. It may be helpful to draw a detailed flow chart of the procedures that are followed as a mammogram is acquired and paperwork is assembled, and then chart the flow of information from the mammographer outward (e.g., to a transcriptionist, to referring physicians, to patients). These steps are essential to define how current procedures can be enhanced by computerization and will also indicate current methods that can be modified vs those that personnel are unwilling to change. Such analysis provides a template by which commercially available systems can be evaluated, and it is a necessary first step for those who decide to design a system.

Mammography↗

How should radiologists reply when patients ask about their diagnoses? A survey of radiologists' and clinicians' preferences.

Radiologists must consider several factors when asked by a patient to disclose the results of a radiologic examination. This study represents a survey of radiologists' and clinicians' opinions regarding disclosure of information to patients by the radiologist. A clearer understanding of the preferences of radiologists and clinicians may serve to improve communication and enhance cooperation between the two groups, with the ultimate result being improved patient care.

Attitude of Health Personnel↗

Quality assessment in radiology: value of a portable bar-code scanner integrated with a computer workstation.

Radiographs are typically processed by several employees of a radiology department before being interpreted by a radiologist. A technologist acquires and labels the radiograph(s), and file room employees match the radiograph(s) with prior examinations and prepare them for interpretation by the radiologist. Every radiologist has encountered radiologic examinations in which the image quality, presentation, or associated clinical or technical information is suboptimal. In small departments, the process of immediately tracking the problem to its source and correcting it might be straightforward, albeit an annoying interruption to the radiologist's focus on clinical care. However, in larger departments, trends of human error or machine malfunction may be overlooked or untraceable because no effective method exists to track the quality of images and associated information. A feedback loop from radiologists to the department's ancillary personnel can result in a cycle of continuous quality improvement that enhances the quality of radiographic examinations and also decreases waste. To achieve this, we designed and implemented a computerized process that involves a portable bar-code scanner, a personal computer workstation, and our existing radiology information system.

Electronic Data Processing↗

Quality assurance: a system that integrates a digital dictation system with a computer data base.

One of the most challenging responsibilities for radiologists is assessment of the quality of care that they provide. Some parameters of quality, such as false-negative rate, are almost impossible to calculate with absolute precision. The issue is also complicated when one tries to determine exactly what constitutes a "discordant" interpretation. However, even when a radiologist discovers that a radiographic finding was missed, or that an inappropriate examination was done, the steps necessary to perform an analysis of the problem can be very disruptive to one's clinical focus at the moment. This suggests that a major obstacle to participation in quality assurance by radiologists is the lack of an adequate infrastructure. We have integrated our digital dictation system with a personal computer data base for tracking cases appropriate for quality assurance, thus allowing radiologists to log any examination from any dictation station in our department with minimal interruption to their clinical activities. Quality assurance and peer review are facilitated by using a personal computer for otherwise tedious aspects of information management. Radiology departments that have a convenient, department-wide method for entering cases--such as a digital dictation system--are ideal for this technique.

Humans↗

Authentication and management of radiologic reports: value of a computer workstation integrated with a radiology information system.

An increasing number of radiology departments are using computers to facilitate management of radiologic information. Transcription, storage, and printing of radiologic reports are among the primary functions of a radiology information system. Consequently, manual signature of radiologic reports is being replaced by on-line electronic authentication. However, the utilities provided on most radiology information systems to review, edit, and otherwise manipulate radiologic reports are relatively crude compared with commercial word-processing and data-base management software available for personal computers. We have developed a personal computer software system that is integrated with our existing radiology information system; expedites the radiologist's task of reviewing, editing, and authenticating (i.e., signing) radiologic reports; provides a teaching file data base on the workstation into which radiologic reports and patients' demographics can be instantly transferred; and provides a similar data base to facilitate follow-up on those examinations deemed appropriate for quality-assurance procedures. These features improve the radiologist's efficiency and increase his or her willingness to more fully exploit the intended purposes of a radiology information system.

Humans↗

Integration of a personal computer workstation and radiology information system for obstetric sonography.

A personal computer workstation has been developed for storage and analysis of obstetric sonographic examinations. The workstation also serves as an interactive data terminal for our radiology information system. A data-base management program locally stores quantitative and descriptive sonographic results. Algorithms are used to analyze growth parameters over serial examinations, plot growth curves, generate a radiologic report, and provide instantaneous diagnostic assistance and suggestions. A bibliographic data-base system containing more than 3000 references (with abstracts) in the obstetric sonographic literature is integrated with the software's analytical functions. A telecommunications software module performs dialogues, such as immediate automatic transcription of the sonographic report, with the radiology information system. An examination summary form, growth curves, and the radiologist's report can be printed or digitally faxed by the workstation after authorization by the radiologist. The workstation has improved the organization of sonographic data, facilitated serial quantitative analysis, supplemented educational resources for our staff radiologists and residents, reduced transcription errors and transcription delays, and shortened to minutes the time necessary to deliver precise examination results to clinicians. This model is suitable for use in many areas in a radiology department.

Female↗