Search PubMed⌕ Search

Biomedical subjects

M Rooze

Publications and source records attributed to M Rooze.

At least 37 records · Page 2Linked to original sources

The prevalence of mycotoxins in Kashin-Beck disease.

Mycotoxins are naturally occurring toxic chemical compounds produced by fungi infesting agricultural crops both during their growth and storage. Such secondary metabolites, when ingested, can produce toxic syndromes in humans. As it has been suggested that mycotoxins might be involved in the development of Kashin-Beck disease (KBD), we undertook a survey of barley grains of KBD-affected families and non-affected families in that country. We found, by thin layer chromatography, a hitherto unknown metabolite of Alternaria sp. This was especially common on the barley grains of KBD-affected families.

Alternaria↗

Three-dimensional kinematics of the lumbar spine during treadmill walking at different speeds.

The lumbar spine is of primary importance in gait and its development is influenced by the upright posture adopted in human locomotion. However, little is known about the kinematic behavior of the lumbar spine during walking. The aim of this study was to examine (1) lumbar spine kinematics during walking, (2) the effect of walking velocity on lumbar motion patterns and (3) the coupling characteristics of rotation and bending. In 22 volunteers aged 15-57 years, the three-dimensional displacements of T12 to the sacrum were sampled during elementary movements of the trunk and during walking on a treadmill at four walking velocities. A three-dimensional electrogoniometer (CA 6000 Spine Motion Analyzer) sampling at 100 Hz was used. We analyzed maximal primary and coupled motion ranges (ROM) and velocities in each plane. Lumbar ROM during walking did not exceed 40% of maximal active ROM. Transverse plane ROM and frontal and transverse velocities increased with walking velocity. Coupling of rotation and bending during walking was individually variable and dependent on walking velocity. Moreover, the smoothness of the bending-rotation path varied with walking velocity. A simplified envelope of lumbar coupling characteristics during walking is presented, and the existence of an individually variable walking speed that is characterized by a more harmonic lumbar contribution is hypothesized.

Adult↗

[Thenar branch of the median nerve and innervation of the trapeziometacarpal joint].

INTRODUCTION: Denervation has been proposed successfully for chronic wrist pain. This procedure is not commonly performed for degenerative osteoarthritis of the trapeziometacarpal joint. According to the classic anatomical descriptions of the wrist innervation, it seems that the thenar branch of the median nerve (TBMN) is the only nerve of the wrist for which no articular branches are clearly defined. The aim of this study is to complete the few anatomical descriptions of the trapeziometacarpal joint innervation with microdissections of the TBMN. MATERIALS AND METHODS: Ten wrist and hand specimens from fresh cadavers were dissected by the same operator under magnification (3.5-12x). The TBMN was identified at its origin from the median nerve and followed in the thenar muscles. All the divisions of the TBMN were identified and followed to their terminal branches. RESULTS: The TBMN divided in at least two main branches, one each to the opponens and to the abductor pollicis brevis. In all but one specimen, the branch to the opponens pollicis muscle passed over or into its medial aspect to spread on the palmar side of the trapezium. Each dissected articular branches were histologically confirmed. DISCUSSION: Our results show a clear participation of the TBMN in the innervation of the trapeziometacarpal joint. The lack of knowledge of this anatomical feature may explain the inconstant results obtained with selective denervation of the trapeziometacarpal joint.

Cadaver↗

Analysis of helical axes, pivot and envelope in active wrist circumduction.

OBJECTIVE: To study active wrist circumduction and planar moves, in terms of anatomical angles and envelope and of finite helical axes and mean pivot point. DESIGN: We measured the position of the "mean pivot point" and its mean distance to the axes as anatomical angles in an in vivo full range movement. BACKGROUND: The mean pivot point has been used in in vitro and roentgen stereophotogrammetric studies of wrist kinematics. However, the distribution of "3D centers of rotation" has never been presented in a non-invasive in vivo study. METHODS: A light 6 degrees of freedom electrogoniometer was built and employed in vivo to measure circumduction, flexion-extension and radioulnar deviation on both wrists of twenty one volunteers. RESULTS: Results were in general agreement with previously published ranges of wrist planar motion. The circumduction envelope proved to be a relevant representation of active wrist motion. The "mean pivot point" displayed a relative dispersion in localization of this point. CONCLUSION: The pivot results suggest that the wrist acts as a universal joint but with a non fixed location in the capitate head. The major axis of wrist envelope was not skew. RELEVANCE: The envelope and the precise knowledge of the helical axis pivot and its mean distance to the axes could give precious information on wrist functionality and stability after surgical or conservative treatment.

Adult↗

Geometrical analysis of the femoral neck torsion.

By the geometrical analysis of three cross sections the surface along the femoral neck, the second moments of area and the major axes of symmetry are obtained. The surface passing through these axes determined in each section, from the lateral to the medial third of the neck, is one of the two anatomical surfaces of symmetry of the neck. The geometric structure defined by this surface is a helicoid. No plane, in the ordinary sense of the word, has to be defined in the femoral neck. At the trochanteric junction, the major axis is inclined about 17 degrees on the anteversion plane, twists anteriorly and becomes more horizontal to finish with a mean inclination of 60 degrees at the cephalic junction. Surprisingly, this twist and then the neck torsion are in opposite directions to that suggested by the bony markers, often taken as a reference and reported in the anatomical descriptions.

Biomechanical Phenomena↗

The capsular ligaments of the wrist: morphology, morphometry and clinical applications.

Variable wrist ligament descriptions and nomenclatures have been presented, but the dimensions of these ligaments have not yet been extensively investigated. To verify the numerous concepts advanced and to provide a better understanding of individual variations in carpal biomechanics, and the numerous pathomechanical concepts reported in the literature, this study aimed to determine capsular carpal ligament anatomy, their dimensions and variations. The origin, insertion, and number of fascicles of the capsular wrist ligaments were observed in precise dissection of 66 anatomic preparations. The dimensions of several capsular wrist ligaments were measured using a calliper: the parameters analysed being length and width at three levels each, from which mean length and width and approximate mean surface (product of mean length by mean width) were determined. The anatomy of the capsular ligaments of the wrist showed, besides relatively constant structures, considerable individual variations, particularly of the ulnocarpal and dorsal ligaments. The standard deviations of ligament lengths and widths were mostly less than 20% of the average value. Some measurements, however, showed larger variations, such as those associated with the dorsal scaphotriquetral and ulnocarpal ligaments. Ligament widths generally showed larger variations and less interdependency than did ligament lengths. The capsular wrist ligaments display morphologic and morphometric variations, which could explain the biomechanical variations reported in the literature, and the diversity of classifications and treatment methods proposed for carpal instability. Further studies, however, are needed to confirm this hypothesis.

Anthropometry↗

Postero-anterior radiography of the wrist: scapholunate ratios and joint projection shape analysis.

A normal database of qualitative and quantitative data, obtained from standard posteroanterior wrist radiographs has been established which might be useful in clinical practice. Variations in the parameters obtained could provide an explanation for the variable carpal kinematics and multiple concepts of carpal instability described in the literature. Selected landmarks were digitized on 80 posteroanterior wrist radiographs of asymptomatic volunteers. Besides classical parameters, measurement of carpal dimensions and angular relationships were also taken. Two new parameters, the scapholunate ratios, are described which evaluate the relative lengths of the frontal projections of the scaphoid and lunate: these ratios might prove useful in the diagnosis of carpal instability. The shapes of the frontal projections of the radiocarpal, midcarpal and STT joint spaces were also analysed. Average values for parameters already reported in the literature agreed with previous findings. Some parameters, however, displayed important individual variations, the standard deviations ranging from 1 to 3 mm for dimensions and from 3 to 13 degrees for angular measurements. The posteroanterior and anteroposterior scapholunate ratios averaged 1.41 +/- 0.21 and 0.66 +/- 0.13 respectively. The potential clinical benefit of these ratios is discussed. Different types of joint space projection shapes could be determined. With respect to the difficulty of obtaining reliable lateral wrist radiographs, compared to posteroanterior radiographs, it is suggested that the clinical significance of the proposed parameters must be evaluated.

Anthropometry↗

Cranio-facial dysmorphism: experimental study in the mouse, clinical applications.

To obtain a better understanding of mandibulo-facial dysostosis and hemicraniofacial microsomia in man, the authors carried out a histologic and scanning electron microscope study of the facial malformations produced in mouse embryos by retinoic acid and methyl-triazene. The administration of 400 mg/kg 13 cis-retinoic acid (RA) to pregnant C57BL mice on day 9 of gestation produced anomalies of the cephalic extremity in the embryos resembling human mandibulo-facial dysostosis. The 64 embryos collected presented hypoplasia of the branchial arches or the snout in 79% of cases, auricular anomalies in 47% and ophthalmic anomalies in 12.5%. Fourteen NMRI mice on day 10.5 of gestation were treated with 1.5 mg (0.5 mg/kg) methyl-triazene (Methyl). The 126 embryos collected had developed a very high percentage of micromandibles and anomalies of both embryonic ears (94.6% to 100%). Finally, although the facial anomalies produced by retinoic acid resemble the human mandibulo-facial dysostosis syndrome, no correlation was found between hemicraniofacial microsomia and the administration of methyl-triazene.

Abnormalities, Drug-Induced↗

The use of disharmonic motion curves in problems of the cervical spine.

Cervical spine motion was investigated by three-dimensional electrogoniometry in 257 asymptomatic volunteers and in 32 patients with cervical disc hernia or whiplash syndrome. Maximal ranges of main and coupled motions were considered. Motion curves were analysed qualitatively and using fitting of sixth degree polynomials. Motion ranges obtained were in agreement with previous observations. Significant differences between patients and volunteers concerned several primary and coupled components but not all. Qualitatively, patients displayed less harmonic curves, with irregularities and plateau-like appearances. Root mean square differences between data and fit were significantly modified in patients. Although cervical spine motion ranges may remain within normal limits in patients, motion patterns were altered qualitatively and quantitatively. Motion pattern analysis might prove a useful discrimination parameter in patients in whom anatomical lesions are not clearly identifiable.

Adolescent↗

Three-dimensional motion patterns of the carpal bones: an in vivo study using three-dimensional computed tomography and clinical applications.

A three-dimensional (3D) CT technique was developed to analyze in vivo segmental carpal kinematics. Transverse CT data of the distal forearm, carpals and proximal metacarpals was acquired and 3D reconstructed in various wrist positions. Carpal kinematics were analyzed in two groups of 20 asymptomatic volunteers, one group in neutral position, flexion and extension (45 degrees), and the other group in neutral position, radial (15 degrees) and ulnar deviation (30 degrees). Qualitative analysis included the 3D study of carpal anatomy, and comparison of carpal bone position between the different sets of data obtained. Carpal bone motion was quantified using rigid body and finite helical axis concepts. The results, although agreeing in principle with previous findings, showed important individual variations in carpal bone motion. Clinical applications were conducted in a series of 25 patients with various wrist disorders. There was no significant difference between the injured wrist and the heterolateral, asymptomatic wrist, but there was a significant difference between asymptomatic volunteers and both the injured wrist and heterolateral wrist of patients. In particular, scaphoid motion was altered bilaterally in our patient group, suggesting the existence of anatomic and/or kinematic factors predisposing to certain carpal pathologies. This hypothesis needs to be confirmed and refined.

Adolescent↗

Normal global motion of the cervical spine: an electrogoniometric study.

OBJECTIVE: Establishment of a normal database and clinical reference of active global cervical spine motion ranges and patterns using a commercial electrogoniometer. DESIGN: Three-dimensional cervical motion ranges and patterns were analyzed in 250 asymptomatic volunteers. BACKGROUND: In vivo out-of-plane motion patterns of the cervical spine have not yet been reported in large populations, but could be of clinical interest. METHODS: In 250 subjects (aged 14-70 yr), motion range and patterns between the first thoracic vertebra and the head were analyzed for flexion-extension, lateral bending, rotation in neutral sagittal plane position and in full flexion using the CA 6000 Spine Motion Analyzer. RESULTS AND CONCLUSIONS: Average motion range in the sagittal plane was 122 degrees (SD: 18 degrees ). Flexion was slightly more important than extension. Out-of-plane components were negligible. Global bending range averaged 88 degrees (SD: 16 degrees ), left and right bending being comparable. Homolateral rotation was associated to lateral bending. Its extent was approximately 40% of the bending range. Global rotation range in neutral sagittal plane position was 144 degrees (SD: 20 degrees ), without significant difference between right and left rotations. Associated motion components were small. During rotation in flexed head position, global range (134 degrees, SD: 24 degrees ) was comparable to the one in neutral flexion. But heterolateral bending, averaging 60% of the primary motion, was associated to flexed rotation. Significant reduction of all primary (but not conjunct) motions with age were obtained. Sex had no influence on cervical motion range. RELEVANCE: Our results agreed with previous observations, validating the methodology used. They thus constitute reference data of cervical out-of-plane motion for clinical applications.

Adolescent↗

[Virtual laparoscopic anatomy of the esophagogastric junction].

The anatomy of the GE junction is represented by computer synthetised pictures. This method allows to represent different organs from different angles, emphasis being put on the laparoscopic angle of vision. This should improve anatomical comprehension. The synthetic pictures have been constructed in a figurative representation. Fatty tissues have been omitted whereas the peritoneal layers covering organs and defining spaces are enhanced.

Anatomy↗

Effects of irradiation and methyl-triazene on craniofacial development in mouse embryos: a semiautomated morphometric analysis.

OBJECTIVE: The purpose of the present study was a 2D-semiautomated morphometric analysis of craniofacial growth in nuclear magnetic resonance imaged (NMRI) mouse embryos. METHODS: The NMRI mouse embryos were exposed in utero to either a single dose of 2 Gy X-irradiation on day 9 of gestation (113 embryos) or to 1.5 mg methyl-triazene administered orally to their pregnant mothers on gestational day 10.5 (124 embryos). An additional group of 108 embryos was used as controls. Digitized pictures of embryos from gestational days 14 to 17 were taken in lateral right view using a video system. Landmarks were located and digitized for computerized analysis of growth changes in relation to developmental stages of the face. RESULTS: The results revealed that the snout of control embryos lengthens during the developmental period considered. The snout of embryos previously submitted to methyl-triazene displayed micrognathia, and all treated fetuses exhibited macroscopic signs of microcephaly with a reduced mandible. The snouts of irradiated embryos appeared shortened at the 14-day stage and continued to shorten as development proceeded. A shortening of the midface was detected macroscopically in 83% of the cases. CONCLUSION: The results of this morphometric analysis enabled us to trace the developmental progression of the induced dysmorphosis and to assess the differences compared with normal development.

Abnormalities, Drug-Induced↗

[The role of apoptosis during craniofacial development: concepts and importance in pathology].

Apoptosis is an essential common final pathway in numerous pathological conditions such as malignant tumors, HIV-related CD4 lymphocytes degeneration, neurodegenerative disorders, and in programmed cell death events during normal embryogenesis. Some teratogenic substances for man and laboratory mammals induce an increase of the apoptotic phenomenon, responsible for the occurrence of some precise cranio-maxillo-facial malformations. The study of cell death during normal or teratogenic embryonic development allows to analyse the cellular mechanisms implied in the control of the apoptotic phenomenon, together with its dysregulation ending in pathological processes. We review the cell death phenomenon during cephalogenesis, both during normal embryogenesis, or in teratogenic conditions known to induce cranio-maxillo-facial malformations.

Abnormalities, Drug-Induced↗

Postero-anterior radiography of the wrist. Normal database of carpal measurements.

This study aims to establish a normal database of carpal postero-anterior radiographic measurements that might be a useful alternative to lateral film measurements in clinical practice. Selected landmarks were digitised on 80 postero-anterior wrist radiographs of asymptomatic volunteers. Carpal bone dimensions, ulnar variance, carpal height ratios, radial slope and various carpal angles were computed. Moreover, we describe two new parameters, the scapho-lunate ratios, that may prove useful in the diagnosis of carpal instability. Average values for carpal height, length of metacarpal III, capitate length, ulnar variance, radial slope and classical and revised carpal height ratios agreed with previous findings. Scaphoid length averaged 22 +/- 3 mm, lunate anterior and posterior horn lengths 11 +/- 1 mm and 16 +/- 2 mm respectively. Except for carpal height and length of metacarpal III, standard deviations did not exceed 3 mm. Some of the variation coefficients reached 30% of the average dimension, so that variations, compared to means were not negligible. The standard deviations of angular measurements ranged from 3 degrees to 13 degrees. Further investigations are needed to confirm the usefulness of scapho-lunate ratios.

Anthropometry↗

High resolution magnetic resonance imaging application in anatomy: the extensor digitorum muscle insertion on the first phalanx.

Classical dissection may give unsatisfactory results because of the presence of artifacts due to both the embalming process and displacement of the anatomical structures. This spatial disturbance could explain the divergent descriptions found in the literature about the presence, or the absence, of an insertion of the extensor digitorum muscle (ED) at the first phalanx (P1). Preliminary experiments by Van Sint Jan et al. (1996) found the same contradiction: dissections did not show a real tendon attachment, whereas a functional experiment seemed to show that "something" should exist between ED and P1 to explain the results. This paper presents the results of an in vitro MRI study of this anatomical area. A 7-T NMR microscope was used to collect accurate, noninvasive data. Subsequently, surface rendering was performed to visualize the structures in a three-dimensional manner. The results of this MRI study, together with functional data obtained in an earlier study, showed that no real insertion of ED on P1 exists. However, some collagenic fibers were occasionally-observed running from the ventral aspect of ED to both P1 and the metacarpo-phalangeal joint capsule. Those few collagenic fibers would play a secondary role in the extension of P1.

Collagen↗