Search PubMed⌕ Search

Biomedical subjects

M Rooze

Publications and source records attributed to M Rooze.

At least 19 recordsLinked to original sources

Multimodal visualization interface for data management, self-learning and data presentation.

A multimodal visualization software, called the Data Manager (DM), has been developed to increase interdisciplinary communication around the topic of visualization and modeling of various aspects of the human anatomy. Numerous tools used in Radiology are integrated in the interface that runs on standard personal computers. The available tools, combined to hierarchical data management and custom layouts, allow analyzing of medical imaging data using advanced features outside radiological premises (for example, for patient review, conference presentation or tutorial preparation). The system is free, and based on an open-source software development architecture, and therefore updates of the system for custom applications are possible.

Anatomy↗

[Changes in knee kinematics and quadriceps and hamstrings moment arms after high valgus and varus tibial "dome" osteotomy: An in vitro study].

PURPOSE OF THE STUDY: Analysis of the correction or over-correction of high valgus and varus tibial osteotomies is generally limited to the frontal plane. Most likely however, the deformation observed radiographically in the frontal plane is simply a one-dimensional expression of a more complex three-dimensional deformation. This might be one of the causes for certain failures after surgery and recurrent problems which are difficult to solve. We proposed using 3D electrogoniometric to measure of the effect of a "dome" osteotomy on patellar and femoro-tibial kinematics and the changes in the moment arms of the knee muscles. MATERIAL AND METHODS: We used five lower limbs harvested from non-fixed cadavers. A "dome" osteotomy was stabilized by external fixation. Three-dimensional analysis of the femoro-tibial and femoro-patellar kinematics was performed using two electrogoniometers with six degrees of freedom. Changes in the lengths of the hamstrings and quadriceps was measured using four LVDT linear variable differential transformers. The muscles lever arms were measured with the tendon excursion method. RESULTS: At 90 degrees flexion, varus osteotomy induced internal rotation while valgus osteotomy induced the opposite effect. Beyond 40 degrees flexion, there was a clear internal rotation of the patella for varus and neutral corrections. Valgus corrections however induced external rotation. The peak lever arm of the quadriceps increased with valgus, while the angle of the peak was higher for varus correction. Valgus appeared to increase the lever arm of the semitendinous. DISCUSSION: Our study demonstrated that the effect of tibial osteotomy is not limited to the frontal plane. Tibial rotations are observed systematically for all corrections in the frontal plane. Varus correction tends to create internal rotation while valgus correction tends to have the opposite effect. Axial correction also affects patellar kinematics. Interanal rotation is induced by varus correction and external rotation by valgus correction. This patellar rotation could result from tibial rotations induced by the different corrections. The loss of the parallelism between the patellar crest and the trochlear groove could produce changes in femoropatellar surface contact and pressure, potentially leading to pain or cartilage degeneration. The maximal value of the quadriceps moment arm appears to increase with valgus. The efficacy of the quadriceps could thus be improved with valgus, potentially increasing extension force. Valgus increases the moment arm, improving limb flexion, while varus correction has the opposite effect. This could explain a loss in flexion amplitude in patients with varus or who underwent varus osteotomy. Tibial osteotomy is designed to correct the deviation solely in the frontal plane but also has effects in all three planes. Further 3D analyses of the morphology and physiology of the knee joint would be needed to better understand the physiological and pathological processes involved.

Biomechanical Phenomena↗

Correlation of Hsp110 expression with caspase-3 and -9 during apoptosis induced by in vivo embryonic exposition to retinoic acid or irradiation in early mouse craniofacial development.

OBJECTIVE: To analyze the expression and role of three proteins (HSP110, caspase-3 and caspase-9) during craniofacial development. DESIGN: Seven pregnant C57Bl/6J mice received, by force-feeding at gestation day 9 (E9), 80 mg/kg of all-trans retinoic acid mixed to sesame oil. Seven pregnant NMRI mice received two grays irradiation at the same gestation day. Control mice of both strains (seven mice for each strain) were not submitted to any treatment. Embryos were obtained at various stages after exposition (3, 6, 12 and 24 h), fixed, dehydrated and embedded. Coronal sections (5 microm) were made. Slide staining occurred alternatively using anti-Hsp110, anti-caspase-3 and anti-caspase-9 immunohistochemistry. RESULTS: Expression of HSP110, caspase-3 and caspase-9 was found in cells of well-known locations of programmed cell death. After retinoic acid exposure, expressions were increased especially in neural crest cells of mandibular and hyoid arches. Quantification of positive cells shows that caspase-9 and Hsp110 were expressed before caspase-3. After irradiation, the expression of the three proteins quickly increased with a maximum 3 h after irradiation. For all three models of apoptosis (physiological, retinoic-induced and irradiation-induced) HSP110 positive cells were more numerous than caspase-3 positive cells. Caspase-3 positive cells were more numerous than caspase-9 positive cells especially in mesectodermal irradiation-induced apoptotic cells. CONCLUSION: The findings show a potential function of HSP110 in apoptosis during embryo development. Caspase-3-expressing cells are more numerous than cells expressing caspase-9, especially irradiation-induced apoptotic neural crest cells. This suggests that other caspases, still to be identified, may activate caspase-3 in this model.

Abnormalities, Drug-Induced↗

A case with undescended testis, left pelvic kidney and gut malrotation.

We describe here an autopsy case presenting bilateral cryptorchidism, left pelvic kidney and intestinal malrotation, evoking a "reverse rotation" with hypoplasia of the cecum. Furthermore, the colon showed alternate bands of stenosis and dilatation. This association has not yet been described, and is discussed in the light of the embryological events of kidney, gut and gonad development. Two hypotheses can explain gut stenoses (vascular consequences of the malrotation and type Hirschprung aganglionic segments).

Aged↗

[Expression of caspase 3 and p53 during physiological apoptosis and apoptosis induced by three teratologic agents during early craniofacial development of the mouse embryo].

The neural crest-derived mesectoderm gives rise to physiologic apoptosis areas in early vertebrate embryos. Certain teratologic agents increase this phenomenon. The purpose of this work was to detect caspase 3 (which is associated with the apoptosis cascade) and p53 in cell death areas, both during physiological apoptosis and during apoptosis induced by three agents (retinoic acid, methyl-triazene, irradiation). Antibody revelation was performed using the aBC peroxidase kit. Quantifications were also performed on histological sections. We observed caspase 3 uptake on some apoptotic and preapoptotic cells in control embryos, and in the embryos exposed to the three teratogens. Immunoreactivity generally preceded the development of cytological features of apoptosis. However, p53 was expressed only in the embryos exposed to ionizing radiation and methyl-triazene (an alkylating agent), but not significantly in embryos exposed to retinoic acid. The present results throw some light on apoptosis mechanisms in several teratologic conditions.

Animals↗

[Validation of a new in vivo measurement method to measure subsidence of a cemented Exeter femoral stem].

PURPOSE OF THE STUDY: Total hip arthroplasty has become one of the most common procedures in orthopedic surgery. These patients must nevertheless be followed with care due to the risk of instability. Knowledge of early migration behavior can provide an indirect assessment of implant fixation. The purpose of this work was to develop a new measurement tool for early assessment of the femoral component. MATERIAL AND METHODS: We analyzed the x-rays of ten Exeter stems (Stryker-Howmedica) implanted between 1996 and 2001 using a simple software designed to calculate the vertical subsidence of each implant. The technical precision and inter-observer reproducibility were checked. RESULTS: The software provided a precision of 0.14-0.3 millimeters. The overall precision of the technique was 1.2 millimeters. There was no statistically significant inter-observer variability. We observed a mean subsidence of 1.3+/-0.7 millimeters at six Months, followed by no further migration. DISCUSSION AND CONCLUSION: This new method was found to be reliable. It is useful for identifying implant migration at different bone-cement-implant interfaces. The time course of subsidence appears to be important to determine threshold values for failure. This tool provides an easy-to-use method for both retrospective and prospective analysis. With minor modifications of the software program, this tool can be used for other types of implants.

Adult↗

[Histologic and ultrastructural features of cell death both physiological and induced by two different teratogens in branchial arches of mouse embryo].

AIM OF THE STUDY: To observe and compare cell death process both physiological and associated with the administration of two different teratogens (irradiation and retinoic acid) inside cephalic mesectoderm. MATERIAL AND METHODS: Irradiated mice: 2 Gy were administered to E 9 embryos. Retinoic acid: 60 mg/kg were gave to E 8 or E 9 embryos. E 9 - 9.5 and E 10 embryos were removed. E 9 - E 9.5 and E 10 control specimens were collected. We used semi-thin sections and ultra-thin sections observed with transmission electron microscope. RESULTS: The major process is apoptosis, which is increased in experimental embryos compared to control specimens. However, autophagy was observed in retinoic acid-treated embryos, while necrosis can rarely occurs after irradiation. CONCLUSION: If the common process seems to be apoptosis, both teratological models differs owing to their respective secondary features. These differences should be explained by the specific pathogenesis of both teratological agents: ligand-receptor reaction and Hox system disruption in retinoic acid administration, direct aggression against DNA and diffuse cell death process following irradiation. Furthermore, congenital malformations induced by these teratogens are quite different. This can be partially explained by a specific blow of different cellular subpopulations.

Animals↗

The proximal attachments of the popliteus muscle: a quantitative study and clinical significance.

Controversies about the existence of accessory proximal popliteus muscle attachments can be found in the literature. The aim of this study was to verify the occurrence and width of popliteus attachments on the articular and periarticular structures of the knee joint. The relation of these attachments to tibiofemoral cartilage and meniscus degeneration was also investigated. Forty-two anatomical specimens were dissected. The incidence of accessory proximal attachments was determined and their width measured using a caliper. The fibular attachment of the popliteus was observed in 98% of cases; its mean width was 11 (SD 3) mm. At least one attachment on the lateral meniscus was found in 95% of the specimens, with a mean width of 6 (SD 2) mm. Three types of meniscal attachments of the popliteus could be identified. The severity of meniscus and tibiofemoral cartilage alterations was significantly related to the number of meniscopopliteal fascicles: more severe alterations were seen in knees with fewer meniscopopliteal fascicles. Popliteus attachments on the posterior knee joint capsule (57%), arcuate (90%) and oblique popliteal (79%) ligaments were also observed in most specimens. Popliteus muscle relationships with the posterior cruciate (5%) and meniscofemoral (33%) ligament were less common. In conclusion, accessory popliteus attachments on the fibula, lateral meniscus and arcuate popliteal ligament can be considered constant characteristics. The results of this study suggest a role of the popliteus in the protection of knee menisci and tibiofemoral cartilage.

Aged↗

Global 3D head-trunk kinematics during cervical spine manipulation at different levels.

OBJECTIVE: Determination of the three-dimensional kinematics of the head relative to the upper trunk obtained during a manipulation applied on two different cervical levels and on both sides. DESIGN: Descriptive study performed on 14 asymptomatic volunteers. The range of motion was measured by a 3D electrogoniometer during manipulation executed by the same practitioner. BACKGROUND: Spinal manipulative therapy is a common treatment approach in patients suffering from some spinal disorders. Complications exist; they are thought to be related to the force applied by the practitioner and the range of spinal motion obtained during the manipulation. Yet, little is known about cervical spine motion during manipulation. METHODS: Three dimensional electrogoniometry using a 6 degree-of-freedom spatial linkage fixed between the head and the upper trunk was used to record the pattern of motion and the amplitudes obtained during a manipulation on two cervical levels (C3 and C5) and on left and right sides. On single practitioner applied the same technique to all subjects in a seated position. RESULTS: The side and the spinal level manipulated did not influence 3D ranges of motion. The mean ranges of motion obtained were 30 degrees axial rotation, 46 degrees lateral bending and 2 degrees flexion. A significant difference of the flexion-extension range existed between manipulations with and without audible release. Axial rotation and lateral bending ranges were correlated. Except for lateral bending which was close to active range, the motion ranges obtained during manipulation were well below active range of motion reported in literature. CONCLUSIONS: The results of this study suggest that for the kind of manipulation applied, maximal amplitude between head and trunk does not exceed physiological active range of motion. The amplitude for rotation, which is generally assumed to involve greatest risks for negative side effects, is significantly lower than during active motion. As the study was performed with one practitioner, this result may only be generalized with care. RELEVANCE: In spinal manipulative therapy, extreme range of motion as the result of the forces applied is generally believed to represent a major risk for negative side effects, especially with regard to the cervical spine. With a multiple component technique, amplitudes between head and upper trunk were shown not to differ significantly with regard to the side nor to the spinal level. Recorded ranges of motion did not exceed those reported for active motion in literature.

Adult↗

Computed tomography of a cyclotocephalic neonate.

Cyclotocephaly is a very rare malformative lethal condition which associates otocephaly (extreme hypoplasia of the mandibular arch with agnathia) and cyclopy with proboscis. The head of a cyclotocephalic neonate from our Museum of Anatomy and Embryology was examined using computed tomography (CT). Cutaneous and osseous three-dimensional reformations were performed. Severe bony malformations were observed. A single orbital cavity was surrounded by a cartilaginous proboscis and a median fusion of maxillae, temporal and zygomatic bones. The single orbital cavity contained both paramedial eyeballs (synophthalmia). The external auditory meati and the ear pinnae were also parasagittal. No oral cavity and mandible were observed. Despite the poor conservation state of the brain, lobar holoprosencephaly was suspected. The mesencephalon and pituitary gland were absent. This exercise could lead to optimizing ultrasonographic prenatal diagnosis.

Abnormalities, Severe Teratoid↗

Registration of 6-DOFs electrogoniometry and CT medical imaging for 3D joint modeling.

The paper describes a method in which two data-collecting systems, medical imaging and electrogoniometry, are combined to allow the accurate and simultaneous modeling of both the spatial kinematics and the morphological surface of a particular joint. The joint of interest (JOI) is attached to a Plexiglas jig that includes four metallic markers defining a local reference system (R(GONIO)) for the kinematics data. Volumetric data of the JOI and the R(GONIO) markers are collected from medical imaging. The spatial location and orientation of the markers in the global reference system (R(CT)) of the medical-imaging environment are obtained by applying object-recognition and classification methods on the image dataset. Segmentation and 3D isosurfacing of the JOI are performed to produce a 3D model including two anatomical objects-the proximal and distal JOI segments. After imaging, one end of a custom-made 3D electrogoniometer is attached to the distal segment of the JOI, and the other end is placed at the R(GONIO) origin; the JOI is displaced and the spatial kinematics data is recorded by the goniometer. After recording, data registration from R(GONIO) to R(CT) occurred prior to simulation. Data analysis was performed using both joint coordinate system (JCS) and instantaneous helical axis (IHA).Finally, the 3D joint model is simulated in real time using the experimental kinematics data. The system is integrated into a computer graphics interface, allowing free manipulation of the 3D scene. The overall accuracy of the method has been validated with two other kinematics data collection methods including a 3D digitizer and interpolation of the kinematics data from discrete positions obtained from medical imaging. Validation has been performed on both superior and inferior radio-ulna joints (i.e. prono-supination motion). Maximal RMS error was 1 degrees and 1.2mm on the helical axis rotation and translation, respectively. Prono-supination of the forearm showed a total rotation of 132 degrees for 0.8mm of translation. The method reproducibility using JCS parameters was in average 1 degrees (maximal deviation=2 degrees ) for rotation, and 1mm (maximal deviation=2mm) for translation. In vitro experiments have been performed on both knee joint and ankle joint. Averaged JCS parameters for the knee were 109 degrees, 17 degrees and 4 degrees for flexion, internal rotation and abduction, respectively. Averaged maximal translation values for the knee were 12, 3 and 4mm posteriorly, medially and proximally, respectively. Averaged JCS parameters for the ankle were 43 degrees, 9 degrees and 3 degrees for plantarflexion, adduction and internal rotation, respectively. Averaged maximal translation values for the ankle were 4, 2 and 1mm anteriorly, medially and proximally, respectively.

Ankle Joint↗

The nerve supply of the trapeziometacarpal joint.

Ten forearm and hand specimens from fresh cadavers were dissected and examined under magnification for articular branches to the trapeziometacarpal joint arising from the thenar and palmar cutaneous branches of the median nerve, the superficial branch of the radial nerve and the lateral cutaneous nerve of forearm. In all but one specimen the thenar branch of the median nerve sent an articular branch to the trapeziometacarpal joint. Multiple branches from the palmar cutaneous branch of the median nerve, the superficial branch of the radial nerve and the lateral cutaneous nerve of forearm were also found. All these branches need to be divided during a "complete" denervation of the trapeziometacarpal joint.

Cadaver↗

Analysis of the capital femoral line orientation. A CT scan study.

An accurate knowledge of the relationship between the neck and the epiphyseal plate at the end of growth is important for biomechanical investigations of femoral neck remodelling during childhood. Statistical data about the position of the epiphyseal femoral cartilage in relation to the neck axis at the end of the growth, are rare in the literature. As the trace of the epiphysis can be observed on a CT scan view of an adult hip, cadaver femurs were investigated to study this relationship and to avoid irradiation of children. The mean anteversion angle of the epiphyseal line towards the patient's coronal plane is 2.3 degrees. The plate is retroverted in an average of 8.2 degrees in relation to the neck axis and is related to neck anteversion. The more the neck is anteverted, the more the plate is retroverted.

Femur↗

Theoretical study of the decrease in the femoral neck anteversion during growth.

This theoretical analysis tries to explain the decrease of the femoral neck anteversion during growth according to well-established concepts. In the frontal plane, it was demonstrated that the capital epiphyseal plate inclination allows the plate to remain perpendicular to the resultant force applied to the hip during gait. In the transversal plane, the projection of this force varies from -24 degrees, outwards and forwards (heel strike), to 20 degrees, outwards and backwards (toe off). A mathematical formula calculates the instantaneous coordinates of the plate in this plane during gait. This kinematic study points out that the physiological value of the capital epiphyseal plate anteversion at the end of the growth is theoretically the ideal value to obtain in the transversal or horizontal plane a perpendicular relation between the orientation of this plate and the projection of the resultant force during walking.

Biomechanical Phenomena↗

[In vivo measurements of shoulder movements by a goniometer with six degrees of freedom: preliminary study].

PURPOSE OF THE STUDY: The purpose of this work was to develop a goniometer with six degrees of freedom (6DOF) to achieve global measurement of the main movements of the shoulder and to examine the reproducibility of the measurements obtained. MATERIAL AND METHODS: Movement amplitudes, inter- and intra-observer reproducibility of the methodology and the device were tested in a population of ten young subjects with asymptomatic shoulders. RESULTS: Maximal amplitudes obtained for each movement were: abduction 111.8 +/- 11 degrees; flexion 127.9 +/- 12.7; external rotation 86.3 +/- 14 degrees; free elevation 129.3 +/- 9 degrees. The curves traced in the plane of rotation and rotation were plotted against elevation. Comparison between amplitudes on the right and left were not significantly different. DISCUSSION AND CONCLUSION: This preliminary study demonstrated the potential contribution of a 6DOF-goniometer for a 3D assessment of shoulder movement. Measurements made when positioning the goniometer demonstrated good reproducibility. Our data are similar to others reported in the literature. The plane of the scapula and the position in physiological internal rotation, as described in the literature, were also observed. Studying shoulder movements, particularly their association, should provide a new means of assessing function in patients with complex disease of the shoulder joint. The device should be helpful in obtaining an objective measurement of the shoulder kinetics that would be useful for patient follow-up and assessment of corporal damage.

Adult↗

Histology of Kashin-Beck lesions.

There are few papers in existence describing the histopathology of Kashin-Beck disease. The few existing papers mention chondronecrosis within the epiphyseal primodium and metaphyseal cartilage. In the present study, two series of samples were available for histology: supernumerary fingers removed from young subjects and intra-articular bodies collected in more advanced cases of the disease. The prevailing characteristic of the samples is the absence of vascularisation within the proximal cartilage end plate of the phalanx associated with an alteration of the epiphyseal bone formation. These observations suggest that Kashin-Beck disease could develop from an alteration of the angiogenesis of the metaphyseal cartilage resulting in degeneration with consequent joint dysplasia, which may be associated with a decrease in growth of the diaphyseal bones.

Adolescent↗

Skeletal deformities induced by the intraperitoneal administration of deoxynivalenol (vomitoxin) in mice.

The contamination of drinking water by organic acids, selenium deficiency and the ingestion of fungal mycotoxins are the three main aetiological factors in the development of Kashin-Beck disease. An avian tibial chondrodysplasia induced by mycotoxins has been reported. Deoxynivalenol (DON) is one of many mycotoxins produced by the most common contaminating species of fungi. The pattern of skeletal malformations induced by its administration intraperitoneally to pregnant mice is reported. Costo-vertebral segmentation abnormalities were the main deformities observed. The chondrodysplasia previously described was not seen.

Animals↗