The sensitivity of tibiofemoral contact pressure to the size and shape of the lateral and medial menisci.

In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements have been studied. A number of biomechanical criteria may be important for a meniscal replacement to restore normal tibiofemoral contact pressure in the knee joint and hence be clinically successful. One of these criteria is geometric similarity. The objectives of the current study were to: determine the sensitivity of the contact variables of the tibial plateau to the transverse depth and width of both the lateral and medial menisci; determine the sensitivity of the contact variables of the tibial plateau to the cross-sectional width and height of the lateral and medial menisci; and determine the tolerances on each of the four parameters for both menisci. To satisfy these objectives, a previously developed finite element model of the tibiofemoral joint was used to compute the contact pressure distribution on the tibial plateau. The effect of the above-mentioned geometric parameters on the contact behavior was studied by perturbing the finite element model. Results showed that the contact variables are similarly sensitive to both the transverse and cross-sectional parameters of the menisci. Additionally the medial meniscal parameters have a greater effect on the contact variables than do the lateral meniscal parameters. Finally, less than a 0.5 mm change in the medial meniscal height and greater than a 1 mm change in the lateral meniscal height could be tolerated before the relative difference in the contact variables from those for the original geometry exceeded 10%. Thus in the design or selection of meniscal replacements, each of the four parameters should be measured when sizing a replacement tissue. Also tighter tolerances should be placed on the medial meniscal parameters compared to the lateral meniscal parameters.

Adult↗

How cyclic loading affects the migration of radio-opaque markers attached to tendon grafts using a new method: a study using roentgen stereophotogrammetric analysis (RSA).

An increase in anterior laxity following reconstruction of the anterior cruciate ligament (ACL) can result from lengthening of the graft construct in either the regions of fixation and/or the region of the graft substance between the fixations. RSA could be a useful technique to determine lengthening in these regions if a method can be devised for attaching radio-opaque markers to soft tissue grafts so that marker migration from repeated loading of the graft is limited. Therefore, the objectives of this study were 1) to develop a method for attaching radio-opaque markers to an ACL graft that limits marker migration within the graft, 2) to characterize the error of an RSA system used to study migration, and 3) to determine the maximum amount of migration and the time when it occurs during cyclic loading of ACL grafts. Tendon markers were constructed from a 0.8-mm tantalum ball and a stainless steel suture. Ten double-looped tendon grafts were passed through tibial tunnels drilled in bovine tibias and fixed with a tibial fixation device. Two tendon markers were sewn to one tendon bundle of each graft and the grafts were cyclically loaded for 225,000 cycles from 20 N to 170 N. At specified intervals, simultaneous radiographs were obtained of the tendon markers and a radiographic standard of known length. The bias and imprecision in measuring the length of the radiographic standard were 0.0 and 0.046 mm respectively. Marker migration was computed as the change in distance between the two tendon markers along the axis of the tibial tunnel. Marker migration was greatest after 225,000 cycles with a root mean square (RMS) value of less than 0.2 mm. Because the RMS value indicates the error introduced into measurements of lengthening and because this error is small, the method described for attaching markers to an ACL graft has the potential to be useful for determining lengthening of ACL graft constructs in in vivo studies in humans.

Animals↗

Initial tension and anterior load-displacement behavior of high-stiffness anterior cruciate ligament graft constructs.

BACKGROUND: Because the tension that exists in an anterior cruciate ligament graft when the knee is unloaded (the initial tension) affects the surgical outcome and because high initial tension has a number of adverse consequences, the primary purpose of this study was to determine quantitatively how much less initial tension was required for a high-stiffness construct than for a low-stiffness construct. A secondary purpose was to determine how the stiffness of the graft construct affects the anterior load-displacement behavior of the knee from 0 degrees to 90 degrees of flexion. METHODS: Anterior-posterior load-displacement was measured in each of ten intact cadaveric knee specimens, the anterior cruciate ligament was excised, and the anterior cruciate ligament was reconstructed with a double-loop bovine tendon graft. Graft constructs of different stiffness were created with use of six springs, ranging in stiffness from 25 to 275 N/mm to simulate the fixation stiffness. After adjusting the initial tension of the graft so that the anterior-posterior laxity of the reconstructed knee matched that of the intact knee, the 0-N posterior limit and the 225-N anterior limit were measured at 0 degrees, 30 degrees, 60 degrees, and 90 degrees of flexion. RESULTS: The highest stiffness fixation (275 N/mm) required an average of 73 N of initial tension, which was more than three times less than the average of 242 N of initial tension required by the lowest stiffness fixation (25 N/mm). The 225-N anterior limit was overconstrained an average of 1.0 mm with the highest stiffness fixation (275 N/mm), which was 3.6 mm less than the overconstraint with the lowest stiffness fixation (25 N/mm). Likewise, the posterior limit was overconstrained an average of 2.6 mm with the highest stiffness fixation (275 N/mm), which was 3.8 mm less than the overconstraint with the lowest stiffness fixation (25 N/mm). CONCLUSIONS: The initial tension for a high-stiffness graft construct is more than three times less than that for a low-stiffness construct. The initial tension for a high-stiffness graft construct better restores both the 225-N anterior limit and the 0-N posterior limit to normal than the initial tension for a low-stiffness graft construct over the range of flexion from 0 degrees to 90 degrees.

Adult↗

How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint.

In an effort to prevent degeneration of articular cartilage associated with meniscectomies, both meniscal allografts and synthetic replacements are subjects of current interest and investigation. The objectives of the current study were to (1) determine whether a transversely isotropic, linearly elastic, homogeneous material model of the meniscal tissue is necessary to achieve a normal contact pressure distribution on the tibial plateau, (2) determine which material and boundary condition (attachments) parameters affect the contact pressure distribution most strongly, and (3) set tolerances on these parameters to restore the contact pressure distribution to within a specified error. To satisfy these objectives, a finite element model of the tibio-femoral joint of a human cadaveric knee (including both menisci) was used to study the contact pressure distribution on the tibial plateau. To validate the model, the contact pressure distribution on the tibial plateau was measured experimentally in the same knee used to create the model. Within physiologically reasonable bounds on five material parameters and four attachment parameters associated with a meniscal replacement, an optimization was performed under 1200 N of compressive load on the set of nine parameters to minimize the difference between the experimental and model results. The error between the experimental and model contact variables was minimized to 5.4%. The contact pressure distribution of the tibial plateau was sensitive to the circumferential modulus, axial/radial modulus, and horn stiffness, but relatively insensitive to the remaining six parameters. Consequently, both the circumferential and axial/radial moduli are important determinants of the contact pressure distribution, and hence should be matched in the design and/or selection of meniscal replacements. In addition, during surgical implantation of a meniscal replacement, the horns should be attached with high stiffness bone plugs, and the attachments of the transverse ligament and deep medial collateral ligament should be restored to minimize changes in the contact pressure distribution, and thereby possibly prevent the degradation of articular cartilage.

Adult↗

Non-driving intersegmental knee moments in cycling computed using a model that includes three-dimensional kinematics of the shank/foot and the effect of simplifying assumptions.

Assessing the importance of non-driving intersegmental knee moments (i.e. varus/valgus and internal/external axial moments) on over-use knee injuries in cycling requires the use of a three-dimensional (3-D) model to compute these loads. The objectives of this study were: (1) to develop a complete, 3-D model of the lower limb to calculate the 3-D knee loads during pedaling for a sample of the competitive cycling population, and (2) to examine the effects of simplifying assumptions on the calculations of the non-driving knee moments. The non-driving knee moments were computed using a complete 3-D model that allowed three rotational degrees of freedom at the knee joint, included the 3-D inertial loads of the shank/foot, and computed knee loads in a shank-fixed coordinate system. All input data, which included the 3-D segment kinematics and the six pedal load components, were collected from the right limb of 15 competitive cyclists while pedaling at 225 W and 90 rpm. On average, the peak varus and internal axial moments of 7.8 and 1.5 N m respectively occurred during the power stroke whereas the peak valgus and external axial moments of 8.1 and 2.5 N m respectively occurred during the recovery stroke. However, the non-driving knee moments were highly variable between subjects; the coefficients of variability in the peak values ranged from 38.7% to 72.6%. When it was assumed that the inertial loads of the shank/foot for motion out of the sagittal plane were zero, the root-mean-squared difference (RMSD) in the non-driving knee moments relative to those for the complete model was 12% of the peak varus/valgus moment and 25% of the peak axial moment. When it was also assumed that the knee joint was revolute with the flexion/extension axis perpendicular to the sagittal plane, the RMSD increased to 24% of the peak varus/valgus moment and 204% of the peak axial moment. Thus, the 3-D orientation of the shank segment has a major affect on the computation of the non-driving knee moments, while the inertial contributions to these loads for motions out of the sagittal plane are less important.

Adolescent↗

The level of compressive load affects conclusions from statistical analyses to determine whether a lateral meniscal autograft restores tibial contact pressure to normal: a study in human cadaveric knees.

This study addressed the question of whether the level of compressive load would affect the conclusions from statistical analyses aimed at determining how well a lateral meniscal autograft restores tibial contact (as indicated by the maximum contact pressure, mean pressure, and contact area) to that of the intact knee. If statistical analyses indicated that normal tibial contact was not restored with a higher, more physiologic load, then a secondary question was whether an autograft surgically implanted with bone plugs would improve tibial contact compared to that in a meniscectomized knee. Nine, fresh-frozen human cadaveric knees were subjected to a low, non-physiologic compressive load of 400 N and a higher, more physiologic compressive load of 1200 N under three conditions (lateral meniscus intact, lateral meniscus removed and reimplanted as an autograft, and lateral meniscus removed). Contact pressure on the lateral plateau was measured with pressure sensitive film at 0 degrees, 15 degrees, 30 degrees, and 45 degrees of flexion. At 400 N, p-values from statistical analyses indicated that both the maximum and mean pressures with the autograft were comparable to those of the intact knee (p> or =0.685). However, at 1200 N, p-values from statistical analyses indicated that both the maximum and mean pressures with the autograft were significantly greater than those of the intact knee (p< or =0.0001). Therefore studies designed to evaluate tibial contact pressure for a meniscal transplant should use a higher, more physiologic compressive load, because lower loads overestimate the transplant's effectiveness. Although none of the contact variables was restored to normal when the compressive load was increased to 1200 N, all of the contact variables were more normal than those of the meniscectomized knee. Thus, lateral meniscal allografts implanted using bone plugs can significantly improve contact pressure relative to a meniscectomized knee at the time of implantation.

Adult↗

Toward an MRI-based method to measure non-uniform cartilage deformation: an MRI-cyclic loading apparatus system and steady-state cyclic displacement of articular cartilage under compressive loading.

Recent magnetic resonance imaging (MRI) techniques have shown potential for measuring non-uniform deformations throughout the volume (i.e. three-dimensional (3D) deformations) in small orthopedic tissues such as articular cartilage. However, to analyze cartilage deformation using MRI techniques, a system is required which can construct images from multiple acquisitions of MRI signals from the cartilage in both the underformed and deformed states. The objectives of the work reported in this article were to 1) design an apparatus that could apply highly repeatable cyclic compressive loads of 400 N and operate in the bore of an MRI scanner, 2) demonstrate that the apparatus and MRI scanner can be successfully integrated to observe 3D deformations in a phantom material, 3) use the apparatus to determine the load cycle necessary to achieve a steady-state deformation response in normal bovine articular cartilage samples using a flat-surfaced and nonporous indentor in unconfined compression. Composed of electronic and pneumatic components, the apparatus regulated pressure to a double-acting pneumatic cylinder so that (1) load-controlled compression cycles were applied to cartilage samples immersed in a saline bath, (2) loading and recovery periods within a cycle varied in time duration, and (3) load magnitude varied so that the stress applied to cartilage samples was within typical physiological ranges. In addition the apparatus allowed gating for MR image acquisition, and operation within the bore of an MRI scanner without creating image artifacts. The apparatus demonstrated high repeatability in load application with a standard deviation of 1.8% of the mean 400 N load applied. When the apparatus was integrated with an MRI scanner programmed with appropriate pulse sequences, images of a phantom material in both the underformed and deformed states were constructed by assembling data acquired through multiple signal acquisitions. Additionally, the number of cycles to reach a steady-state response in normal bovine articular cartilage was 49 for a total cycle duration of 5 seconds, but decreased to 33 and 27 for increasing total cycle durations of 10 and 15 seconds, respectively. Once the steady-state response was achieved, 95% of all displacements were within +/- 7.42 microns of the mean displacement, indicating that the displacement response to the cyclic loads was highly repeatable. With this performance, the MRI-loading apparatus system meets the requirements to create images of articular cartilage from which 3D deformation can be determined.

Adaptation, Physiological↗

Effect of the angle of the femoral and tibial tunnels in the coronal plane and incremental excision of the posterior cruciate ligament on tension of an anterior cruciate ligament graft: an in vitro study.

BACKGROUND: High tension in an anterior cruciate ligament graft adversely affects both the graft and the knee; however, it is unknown why high graft tension in flexion occurs in association with a posterior femoral tunnel. The purpose of the present study was to determine the effect of the angle of the femoral and tibial tunnels in the coronal plane and incremental excision of the posterior cruciate ligament on the tension of an anterior cruciate ligament graft during passive flexion. METHODS: Eight cadaveric knees were tested. The angle of the tibial tunnel was varied to 60 degrees, 70 degrees, and 80 degrees in the coronal plane with use of three interchangeable, low-friction bushings. The femoral tunnel, with a 1-mm-thick posterior wall, was drilled through the tibial tunnel bushing with use of the transtibial technique. After the graft had been tested in all three tibial bushings with one femoral tunnel, the femoral tunnel was filled with bone cement and the tunnel combinations were tested. Lastly, the graft was replaced in the 80 degrees femoral and tibial tunnels, and the tests were repeated with excision of the lateral edge of the posterior cruciate ligament in 2-mm increments. Graft tension, the flexion angle, and anteroposterior laxity were recorded in a six-degrees-of-freedom load-application system that passively moved the knee from 0 degrees to 120 degrees of flexion. RESULTS: The graft tension at 120 degrees of flexion was affected by the angle of the femoral tunnel and by incremental excision of the posterior cruciate ligament. The highest graft tension at 120 degrees of flexion was 169 +/- 9 N, which was detected with the graft in the 80 degrees femoral and 80 degrees tibial tunnels. The lowest graft tension at 120 degrees of flexion was 76 +/- 8 N, which was detected with the graft in the 60 degrees femoral and 60 degrees tibial tunnels. The graft tension of 76 N at 120 degrees of flexion with the graft in the 60 degrees femoral and 60 degrees tibial tunnels was closer to the tension in the intact anterior cruciate ligament. Excision of the lateral edge of the posterior cruciate ligament in 2 and 4-mm increments significantly lowered the graft tension at 120 degrees of flexion without changing the anteroposterior position of the tibia. CONCLUSIONS: Placing the femoral tunnel at 60 degrees in the coronal plane lowers graft tension in flexion. Our results suggest that high graft tension in flexion is caused by impingement of the graft against the posterior cruciate ligament, which results from placing the femoral tunnel medially at the apex of the notch in the coronal plane.

Adult↗

Experimental optimization of pivot point height for swing-arm type rear suspensions in off-road bicycles.

Towards the ultimate goal of designing dual suspension off-road bicycles which decouple the suspension motion from the pedaling action, this study focused on determining experimentally the optimum pivot point height for a swing-arm type rear suspension such that the suspension motion was minimized. Specific objectives were (1) to determine the effect of interaction between the front and rear suspensions on the optimal pivot point height, (2) to investigate the sensitivity of the optimal height to the pedaling mechanics of the rider in both the seated and standing postures, (3) to determine the dependence of the optimal height on the rider posture. Eleven experienced subjects rode a custom-built adjustable dual suspension off-road bicycle, [Needle, S., and Hull, M. L., 1997, "An Off-Road Bicycle With Adjustable Suspension Kinematics," Journal of Mechanical Design 119, pp. 370-375], on an inclined treadmill. The treadmill was set to a constant 6 percent grade at a constant velocity of 24.8 km/hr. With the bicycle in a fixed gear combination of 38 x 14, the corresponding cadence was 84 rpm. For each subject, the pivot point height was varied randomly while the motions across both the front and rear suspension elements were measured. Subjects rode in both the seated and standing postures and with the front suspension active and inactive. It was found that the power loss from the rear suspension at the optimal pivot point height was not significantly dependent on the interaction between the front and rear suspensions. In the seated posture, the optimal pivot point height was 9.8 cm on average and had a range of 8.0-12.3 cm. The average optimal pivot point height for the seated posture corresponded to an average power loss for the rear suspension that was within 10 percent of the minimum power loss for each subject for 8 of the 11 subjects. In the standing posture, the average height was 5.9 cm and ranged from 5.1-7.2 cm. The average heightfor the standing posture was within 10 percent of the minimum power loss for each subject for 9 of the 11 subjects. While the optimum height was relatively insensitive to pedaling mechanics in both the seated and standing postures, the choice of the optimal pivot point height in production bicycles necessitates some compromise in performance given the disparity in the averages between the seated and standing postures.

Adult↗

A finite element model of the human knee joint for the study of tibio-femoral contact.

As a step towards developing a finite element model of the knee that can be used to study how the variables associated with a meniscal replacement affect tibio-femoral contact, the goals of this study were 1) to develop a geometrically accurate three-dimensional solid model of the knee joint with special attention given to the menisci and articular cartilage, 2) to determine to what extent bony deformations affect contact behavior, and 3) to determine whether constraining rotations other than flexion/extension affects the contact behavior of the joint during compressive loading. The model included both the cortical and trabecular bone of the femur and tibia, articular cartilage of the femoral condyles and tibial plateau, both the medial and lateral menisci with their horn attachments, the transverse ligament, the anterior cruciate ligament, and the medial collateral ligament. The solid models for the menisci and articular cartilage were created from surface scans provided by a noncontacting, laser-based, three-dimensional coordinate digitizing system with an root mean squared error (RMSE) of less than 8 microns. Solid models of both the tibia and femur were created from CT images, except for the most proximal surface of the tibia and most distal surface of the femur which were created with the three-dimensional coordinate digitizing system. The constitutive relation of the menisci treated the tissue as transversely isotropic and linearly elastic. Under the application of an 800 N compressive load at 0 degrees of flexion, six contact variables in each compartment (ie., medial and lateral) were computed including maximum pressure, mean pressure, contact area, total contact force, and coordinates of the center of pressure. Convergence of the finite element solution was studied using three mesh sizes ranging from an average element size of 5 mm by 5 mm to 1 mm by 1 mm. The solution was considered converged for an average element size of 2 mm by 2 mm. Using this mesh size, finite element solutions for rigid versus deformable bones indicated that none of the contact variables changed by more than 2% when the femur and tibia were treated as rigid. However, differences in contact variables as large as 19% occurred when rotations other than flexion/extension were constrained. The largest difference was in the maximum pressure. Among the principal conclusions of the study are that accurate finite element solutions of tibio-femoral contact behavior can be obtained by treating the bones as rigid. However, unrealistic constraints on rotations other than flexion/extension can result in relatively large errors in contact variables.

Adult↗

Identification of cross-sectional parameters of lateral meniscal allografts that predict tibial contact pressure in human cadaveric knees.

To guide the development of improved procedures for selecting meniscal allografts, the objective of this study was to identify which cross-sectional parameters of a lateral meniscal allograft predict the contact pressure of the articular surface of the tibia. To meet the objective, the contact pressure of the articular surface of the tibia was measured with a lateral meniscal autograft and a lateral meniscal allograft using pressure sensitive film in 15 fresh-frozen human cadaveric knees. Allografts were matched only in transverse dimensions to the autograft but not in cross-sectional dimensions. Knees were loaded to 1200 N in compression at flexion angles of 0, 15, 30 and 45 degrees using a load application system that allowed unconstrained motion in the remaining degrees of freedom. Five cross-sectional parameters for both of the grafts in each of the anterior, middle, and posterior regions were derived from measurements obtained using a laser-based non-contacting three-dimensional coordinate digitizing system (3-DCDS) (Haut et al., J. Orthop Res, 2000). Five contact variables (i.e. the maximum pressure, mean pressure, contact area, and anterior-posterior and medial-lateral locations of the centroid of contact area) were determined from the pressure sensitive film. When each allograft was paired with the corresponding autograft, the root mean squared percent differences for the cross-sectional parameters ranged from a minimum of 28% for the width of the posterior region to 572% for the height of the posterior region. The root mean squared percent differences between the contact variables for paired grafts were 29% for the maximum pressure, 19% for the mean pressure, and 24% for the contact area. Differences in the cross-sectional parameters between the grafts were related to differences in the contact variables using regression analysis. Difference in the width was most often a predictor variable in the regression models with R2 values > or = 0.45. Differences in all of the four remaining cross-sectional parameters were also important predictor variables. Because failure to match cross-sectional parameters causes substantial difference in contact variables between an allograft and autograft and because cross-sectional parameters predict the contact pressure on the tibial plateau, protocols used to prospectively select allografts should concentrate on matching cross-sectional parameters and particularly the width to those of the original meniscus.

Adult↗

A method for quantifying the anterior load-displacement behavior of the human knee in both the low and high stiffness regions.

The anterior load-displacement behavior of the human knee with an intact ACL is characterized by a very low stiffness region initially and a high stiffness region that develops as anterior load is increased. Although this behavior has been well recognized for some time, a method for quantitatively describing the behavior in these two regions based on limits of motion at specific values of anterior/posterior force has not yet been developed. Thus, the purposes of this study were to describe and justify such a method for measuring the laxity and stiffness in both of these regions in the intact knee. Unique to this study, low stiffness and high stiffness laxities were computed based on three limits of motion for seven cadaveric knees tested at flexion angles ranging from 0 degrees to 90 degrees. Defining the reference position of the tibia relative to the femur, one limit was the 0 N posterior limit which was determined using a specially designed load cycle to reduce uncertainty in establishing a reference position. Defining the upper bound of the load-displacement curve, a second limit was the 225 N anterior limit. A third intermediate limit was the 45 N anterior limit, which was the load that represented the transition from the low stiffness to the high stiffness region. Stiffnesses corresponding to each of the two regions were computed using regression analysis and also estimated based on the laxities. Comparison between the computed and estimated stiffnesses demonstrated that the stiffnesses in both the low and high stiffness regions can be estimated reasonably accurately based on the laxities. Therefore, the 0 N posterior limit and the two laxities are the three quantities needed to describe the load-displacement behavior of the normal knee.

Aged↗

Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons.

Due to ready availability, decreased cost, and freedom from transmissible diseases in humans such as hepatitis and AIDS, it would be advantageous to use tendon grafts from farm animals as a substitute for human tendon grafts in in vitro experiments aimed at improving the outcome of anterior cruciate ligament (ACL) reconstructive surgery. Thus the objective of this study was to determine whether an anterior cruciate ligament (ACL) graft composed of two loops of bovine common digital extensor tendon has the same viscoelastic, structural, and material properties as a graft composed of a double loop of semitendinosus and gracilis tendons from humans. To satisfy this objective, grafts were constructed from each tissue source. The cross-sectional area was measured using an area micrometer, and each graft was then pulled using a materials testing system while submerged in a saline bath. Using two groups of tendon grafts (n = 10), viscoelastic tests were conducted over a three-day period during which a constant displacement load relaxation test was followed by a constant amplitude, cyclic load creep test (first day), a constant load creep test (second day), and an incremental cyclic load creep test (third day). Load-to-failure tests were performed on two different groups of grafts (n = 8). When the viscoelastic behavior was compared, there were no significant differences in the rate of load decay or the final load (relaxation test) and rates of displacement increase or final displacements (creep tests) (p > 0.115). To compare both the structural and material properties in the toe region (i.e., < 250 N) of the load-elongation curve, the tangent stiffness and modulus functions were computed from parameters used in an exponential model fit to the load (stress)-elongation (strain) data. Although one of the two parameters in the functions was different statistically, this difference translated into a difference of only 0.03 mm in displacement at 250 N of load. In the linear region (i.e., 50-75 percent of ultimate load) of the load-elongation curve, the linear stiffness of the two graft types compared closely (444 N/mm for bovine and 418 N/mm for human) (p = 0.341). At failure, the ultimate loads (2901 N and 2914 N for bovine and human, respectively) and the ultimate stresses (71.8 MPa and 65.6 MPa for bovine and human, respectively) were not significantly different (p > 0.261). The theoretical effect of any differences in properties between these two grafts on the results of two types of in vitro experiments (i.e., effect of surgical variables on knee laxity and structural properties of fixation devices) are discussed. Despite some statistical differences in the properties evaluated, these differences do not translate into important effects on the dependent variables of interest in the experiments. Thus the bovine tendon graft can be substituted for the human tendon graft in both types of experiments.

Animals↗

In vivo calibration of a femoral fixation device transducer for measuring anterior cruciate ligament graft tension: a study in an ovine model.

Toward developing a transducer for measuring in vivo tension in anterior cruciate ligament grafts in humans, the objectives of this study were to determine the following: (1) whether the calibration of a previously reported femoral fixation device transducer (FDT) (Ventura et al., 1998) is affected by the presence of the graft when implanted in the tibial metaphysis of an ovine model, (2) whether the FDT remains calibrated at 4 weeks postoperatively, and (3) whether the biological incorporation of the graft occurs prior to a change in the FDT calibration. The FDT was implanted in the hind limb of five sheep using an extra-articular procedure. Both the proximal common digital extensor tendon (i.e., graft) and a Teflon-coated wire were looped around the FDT inside a tunnel in the tibial metaphysis. The FDT was calibrated on three occasions using the loop of wire: once intraoperatively before graft insertion, once intraoperatively after graft insertion, and once postoperatively after the animals had been sacrificed at 4 weeks. Following sacrifice, the load transmitted to the FDT by the graft was also determined. The FDT exhibited linear calibration intraoperatively both before and after graft insertion with an average error relative to the calibration before insertion of the graft of -4.6 percent of full-scale load (150 N) and this average relative error was not significantly different from zero (p = 0.183). After 4 weeks of implantation, the average relative percent error was -5.0 percent and was not significantly different from zero (p = 0.434) indicating that the FDT remained calibrated in the in vivo environment. Because only 15 percent of the graft tension was transmitted to the FDT after 4 weeks, biological incorporation of the graft preceded the loss of calibration. In light of these findings, the FDT offers the capability of measuring the intra-articular ACL graft tension in vivo in animal models and possibly humans before the biological bond develops and also of monitoring the formation and maturation of the biological bond between a graft and bone tunnel.

Animals↗

Vascular complications after hemostatic puncture closure device (Angio-Seal) are not higher in overweight patients.

BACKGROUND: Angio-Seal (Daig Corporation, Minnetonka, Minnesota) allows earlier discharge from the hospital after coronary angiography. Manual compression in overweight patients after percutaneous procedures is associated with a higher incidence of groin complications. The purpose of this study was to determine if a vascular closure device could be safely used without increasing the risk of vascular complications in overweight patients. METHODS: A total of 198 patients who received the 6 French Angio-Seal device after diagnostic coronary angiography were divided into 3 groups. Group A included patients with a body mass index (BMI) of < or = 25, group B with BMI between 25 and 30, and group C with BMI > or = 30. Patients were followed for groin complications during their hospital stay. RESULTS: Complication rates were comparable between the 3 groups. Groin complications occurred in 11% in group A, 5% in group B and 6% in group C. CONCLUSION: After diagnostic cardiac catheterization, a vascular closure device such as Angio-Seal can be safely used in overweight patients.

Aged↗

Use of roentgenography and magnetic resonance imaging to predict meniscal geometry determined with a three-dimensional coordinate digitizing system.

To evaluate and improve on the procedures used by a tissue bank in selecting donor menisci for transplantation, this study was designed to fulfill four objectives: (a) define and quantify a set of independent parameters for describing the geometry of the medial and lateral menisci, (b) determine how well the sizing protocol of the tissue bank (i.e., two transverse roentgenographic measurements obtained from the injured knee or six transverse magnetic resonance imaging measurements obtained from the contralateral knee) predicts the four standard transverse parameters of the menisci, (c) determine if including one additional transverse roentgenographic measurement for each compartment improves the ability of roentgenograms to predict transverse meniscal parameters, and (d) determine if five magnetic resonance imaging measurements at three different meniscal cross sections of the contralateral knee predict the 15 standard cross-sectional parameters of the meniscus in the injured knee. A laser-based, noncontacting three-dimensional coordinate digitizing system was used to determine surface coordinates from which menisci were reconstructed in a computer. For each reconstructed meniscus, four parameters in the transverse plane and five cross-sectional parameters in each of three regions (i.e., anterior, middle, and posterior) were defined, yielding a set of 19 standard parameters to describe the geometry. Through a correlation analysis, these standard parameters were shown to be largely unrelated to one another, thus confirming that the parameters form an independent set describing the three-dimensional geometry of the menisci. The two roentgenographic measurements were poor predictors of transverse standard meniscal parameters, predicting only one of four standard parameters for the medial meniscus and none of four standard parameters for the lateral meniscus with coefficients of determination greater than or equal to 0.5. Including one additional roentgenographic measurement to the tissue bank protocol increased the number of standard transverse parameters predicted to three of four for the medial meniscus and two of four for the lateral meniscus. Magnetic resonance imaging was better than roentgenography for predicting the three-dimensional meniscal geometry. The transverse measurements from magnetic resonance imaging predicted three of four standard transverse parameters for the medial meniscus and all four for the lateral meniscus. With the addition of the cross-sectional measurements by magnetic resonance imaging, seven of 15 standard cross-sectional parameters were predicted for both the medial and lateral menisci. Assuming that a successful clinical outcome depends on how well an allograft matches the size and shape of the original meniscus, magnetic resonance imaging rather than roentgenography should be used for allograft size-matching by tissue banks.

Adult↗

Is the circumferential tensile modulus within a human medial meniscus affected by the test sample location and cross-sectional area?

Quantifying the material properties of the human menisci is paramount to understanding their biomechanical functions within the knee. One important intrinsic material property governing the biomechanical functions of the meniscus is the circumferential tensile modulus. The purpose of this study was to determine if the circumferential tensile modulus of the human medial meniscus depends on the location and thickness of the sample tested. The following three hypotheses were tested: (a) the circumferential location (anterior, central, and posterior) does not significantly affect the tensile modulus, (b) the radial location (inner to outer) significantly affects the tensile modulus, and (c) the thickness (cross-sectional area) significantly affects the tensile modulus. Test samples, whose length was oriented in parallel with the circumferential collagen fibers, were collected from different circumferential and radial locations throughout 30 human medial menisci. Samples of three different thicknesses (0.5, 1.5, and 3.0 mm) were taken from three equal groups of 10 menisci (i.e., one thickness per group). The circumferential tensile modulus was measured under quasi-static loading. Statistical analysis showed no significant effect of the circumferential or radial location of the sample on the circumferential tensile modulus. This indicates that an overall circumferential tensile modulus may be calculated for the human medial meniscus by averaging the values determined at the various locations. However, the thickness of the test sample had a significant effect on the measured circumferential tensile modulus; the modulus varied inversely with the thickness. Thus, moduli determined from test samples that are too small in cross-sectional area overestimate the effective modulus of the tissue on the whole, and the cross-sectional area of the sample must be considered when determining a representative circumferential tensile modulus for the medial meniscus in a human knee.

Adult↗

Biventricular pacing in end-stage heart failure improves functional capacity and left ventricular function.

BACKGROUND: Asynchronous patterns of contraction and relaxation may contribute to hemodynamic and functional impairment in heart failure. In 1993, we introduced biventricular pacing as a novel method to treat heart failure by synchronous stimulation of the right and left ventricles after an appropriate atrioventricular delay. The objectives of this study were to assess the early and long-term effects of this therapy on functional capacity and left ventricular function in patients with severe heart failure and left bundle branch block. METHODS AND RESULTS: Twelve patients with end-stage congestive heart failure, sinus rhythm and complete left bundle branch block were treated with biventricular stimulation at optimized atrioventricular delay. The NYHA functional class and maximal bicycle exercise capacity were assessed. Systolic and diastolic left ventricular function were studied with echocardiography and radionuclide angiography. Data was collected at various intervals during 1-year follow-up. Cumulative survival [95% CI] was 66.7% [40.0,93.4] at 1 year and 50 % [21.8, 78.2] at 2 and 3 years. Median NYHA class improved from class IV to class II at 1 year (p=0.008). After 6 weeks an increase in exercise capacity occurred, which was sustained. A less restrictive left ventricular filling pattern, an increase in dP/dt and left ventricular ejection fraction, and a decrease in mitral regurgitation were observed early and long-term. CONCLUSIONS: Biventricular pacing at optimized atrioventricular delay results in improvement in functional capacity, which is associated with improved systolic and diastolic left ventricular function, and a decrease in mitral regurgitation during short- and long-term follow-up.