Use of roentgenography and magnetic resonance imaging to predict meniscal geometry determined with a three-dimensional coordinate digitizing system.

To evaluate and improve on the procedures used by a tissue bank in selecting donor menisci for transplantation, this study was designed to fulfill four objectives: (a) define and quantify a set of independent parameters for describing the geometry of the medial and lateral menisci, (b) determine how well the sizing protocol of the tissue bank (i.e., two transverse roentgenographic measurements obtained from the injured knee or six transverse magnetic resonance imaging measurements obtained from the contralateral knee) predicts the four standard transverse parameters of the menisci, (c) determine if including one additional transverse roentgenographic measurement for each compartment improves the ability of roentgenograms to predict transverse meniscal parameters, and (d) determine if five magnetic resonance imaging measurements at three different meniscal cross sections of the contralateral knee predict the 15 standard cross-sectional parameters of the meniscus in the injured knee. A laser-based, noncontacting three-dimensional coordinate digitizing system was used to determine surface coordinates from which menisci were reconstructed in a computer. For each reconstructed meniscus, four parameters in the transverse plane and five cross-sectional parameters in each of three regions (i.e., anterior, middle, and posterior) were defined, yielding a set of 19 standard parameters to describe the geometry. Through a correlation analysis, these standard parameters were shown to be largely unrelated to one another, thus confirming that the parameters form an independent set describing the three-dimensional geometry of the menisci. The two roentgenographic measurements were poor predictors of transverse standard meniscal parameters, predicting only one of four standard parameters for the medial meniscus and none of four standard parameters for the lateral meniscus with coefficients of determination greater than or equal to 0.5. Including one additional roentgenographic measurement to the tissue bank protocol increased the number of standard transverse parameters predicted to three of four for the medial meniscus and two of four for the lateral meniscus. Magnetic resonance imaging was better than roentgenography for predicting the three-dimensional meniscal geometry. The transverse measurements from magnetic resonance imaging predicted three of four standard transverse parameters for the medial meniscus and all four for the lateral meniscus. With the addition of the cross-sectional measurements by magnetic resonance imaging, seven of 15 standard cross-sectional parameters were predicted for both the medial and lateral menisci. Assuming that a successful clinical outcome depends on how well an allograft matches the size and shape of the original meniscus, magnetic resonance imaging rather than roentgenography should be used for allograft size-matching by tissue banks.

Adult↗

Biventricular pacing in end-stage heart failure improves functional capacity and left ventricular function.

BACKGROUND: Asynchronous patterns of contraction and relaxation may contribute to hemodynamic and functional impairment in heart failure. In 1993, we introduced biventricular pacing as a novel method to treat heart failure by synchronous stimulation of the right and left ventricles after an appropriate atrioventricular delay. The objectives of this study were to assess the early and long-term effects of this therapy on functional capacity and left ventricular function in patients with severe heart failure and left bundle branch block. METHODS AND RESULTS: Twelve patients with end-stage congestive heart failure, sinus rhythm and complete left bundle branch block were treated with biventricular stimulation at optimized atrioventricular delay. The NYHA functional class and maximal bicycle exercise capacity were assessed. Systolic and diastolic left ventricular function were studied with echocardiography and radionuclide angiography. Data was collected at various intervals during 1-year follow-up. Cumulative survival [95% CI] was 66.7% [40.0,93.4] at 1 year and 50 % [21.8, 78.2] at 2 and 3 years. Median NYHA class improved from class IV to class II at 1 year (p=0.008). After 6 weeks an increase in exercise capacity occurred, which was sustained. A less restrictive left ventricular filling pattern, an increase in dP/dt and left ventricular ejection fraction, and a decrease in mitral regurgitation were observed early and long-term. CONCLUSIONS: Biventricular pacing at optimized atrioventricular delay results in improvement in functional capacity, which is associated with improved systolic and diastolic left ventricular function, and a decrease in mitral regurgitation during short- and long-term follow-up.

Bundle-Branch Block↗

A theoretical analysis of preferred pedaling rate selection in endurance cycling.

One objective of this study was to investigate whether neuromuscular quantities were associated with preferred pedaling rate selection during submaximal steady-state cycling from a theoretical perspective using a musculoskeletal model with an optimal control analysis. Specific neuromuscular quantities of interest were the individual muscle activation, force, stress and endurance. To achieve this objective, a forward dynamic model of cycling and optimization framework were used to simulate pedaling at three different rates of 75, 90 and 105 rpm at 265 W. The pedaling simulations were produced by optimizing the individual muscle excitation timing and magnitude to reproduce experimentally collected data. The results from these pedaling simulations indicated that all neuromuscular quantities were minimized at 90 rpm when summed across muscles. In the context of endurance cycling, these results suggest that minimizing neuromuscular fatigue is an important mechanism in pedaling rate selection. A second objective was to determine whether any of these quantities could be used to predict the preferred pedaling rate. By using the quantities with the strongest quadratic trends as the performance criterion to be minimized in an optimal control analysis, these quantities were analyzed to assess whether they could be further minimized at 90 rpm and produce normal pedaling mechanics. The results showed that both the integrated muscle activation and average endurance summed across all muscles could be further minimized at 90 rpm indicating that these quantities cannot be used individually to predict preferred pedaling rates.

Adult↗

The influence of pedaling rate on bilateral asymmetry in cycling.

The objectives of this study were to (1) determine whether bilateral asymmetry in cycling changed systematically with pedaling rate, (2) determine whether the dominant leg as identified by kicking contributed more to average power over a crank cycle than the other leg, and (3) determine whether the dominant leg asymmetry changed systematically with pedaling rate. To achieve these objectives, data were collected from 11 subjects who pedaled at five different pedaling rates ranging from 60 to 120 rpm at a constant workrate of 260 W. Bilateral pedal dynamometers measured two orthogonal force components in the plane of the bicycle. From these measurements, asymmetry was quantified by three dependent variables, the percent differences in average positive power (%AP), average negative power (%AN), and average crank power (%AC). Differences were taken for two cases--with respect to the leg generating the greater total average for each power quantity at 60 rpm disregarding the measure of dominance, and with respect to the dominant leg as determined by kicking. Simple linear regression analyses were performed on these quantities both for the subject sample and for individual subjects. For the subject sample, only the percent difference in average negative power exhibited a significant linear relationship with pedaling rate; as pedaling rate increased, the asymmetry decreased. Although the kicking dominant leg contributed significantly greater average crank power than the non-dominant leg for the subject sample, the non-dominant leg contributed significantly greater average positive power and average negative power than the dominant leg. However, no significant linear relationships for any of these three quantities with pedaling rate were evident for the subject sample because of high variability in asymmetry among the subjects. For example, significant linear relationships existed between pedaling rates and percent difference in total average power per leg for only four of the 11 subjects and the nature of these relationships was different (e.g. positive versus negative slopes). It was concluded that pedaling asymmetry is highly variable among subjects and that individual subjects may exhibit different systematic changes in asymmetry with pedaling rate depending on the quantity of interest.

Adult↗

Contributions of femoral fixation methods to the stiffness of anterior cruciate ligament replacements at implantation.

One purpose of this study was to determine the stiffness of three femoral fixation methods used commonly in anterior cruciate ligament (ACL) reconstruction to secure a double-looped semitendinosus and gracilis (DLSTG) graft and then assess how the stiffness of these methods affects the stiffness of the young human femur-fixation method-graft complex at the time of reconstruction. A second purpose was to define principles for adjusting the stiffness of the ACL replacement (defined as the femoral fixation method plus DLSTG graft plus tibial fixation method) to match that of the native ACL. The stiffness of a DLSTG graft and the stiffness of the femur-fixation method-DLSTG graft complex for three endoscopic fixation methods were measured. Fixations of the DLSTG graft to a button, anchor, and post, both with and without compaction of bone, were tested in young, human femur. The stiffness of each fixation was calculated by modeling the DLSTG graft and fixation method as a series of springs. The stiffness of the DLSTG graft averaged 954+/-292 N/mm. The stiffness of the DLSTG graft-fixation complex was lowered fourfold to 40-fold by adding fixation. The method of fixation determined the reduction in stiffness. The stiffness of the femur-button-DLSTG graft complex averaged 23+/-2 N/mm, the femur-anchor-DLSTG graft complex averaged 25+/-3 N/mm, and the femur-post with bone graft-DLSTG graft complex averaged 225+/-23 N/mm (P = .0001). The knot in the suture loop was the least stiff component and determined the stiffness when the DLSTG graft was fixed with both the button and anchor. Compaction of bone significantly increased stiffness by an average of 41+/-14 N/mm (P = .027). Because the stiffness of femoral fixation methods are 4 to 40 times less than the stiffness of the graft, increasing the stiffness of an ACL replacement would be best achieved by selecting fixation methods with higher stiffness and not by either shortening the graft or increasing the cross-sectional area of the graft.

Adult↗

Sudden death in recipients of transvenous implantable cardioverter defibrillator systems: terminal events, predictors, and potential mechanisms.

INTRODUCTION: Transvenous implantable cardioverter defibrillator (ICD) systems are very effective in preventing sudden death; however, little is known about terminal events and potential causes and mechanisms of sudden death in recipients of these devices. METHODS AND RESULTS: We analyzed 74 cases of sudden death among patients enrolled in several clinical investigations of transvenous ICD systems. Eighty-one percent were men (mean age 68+/-10 years), 86% had coronary artery disease, mean left ventricular ejection fraction was 0.27+/-0.11, and two thirds presented with sustained ventricular tachycardia. The final event was witnessed in 65 patients (81%). Based on reported ICD shocks, documented rhythm, and/or postmortem device data, sudden death was deemed tachyarrhythmic in 49 cases (66%), nontachyarrhythmic in 12 (16%), and indeterminate in the remaining 13 (18%). Multivariate analysis of several clinical and nonclinical factors found advanced age (> 65 years, P = 0.03, odds ratio [OR] 1.75, 95 % confidence interval [CI] 1.05 to 2.92), reduced left ventricular ejection fraction (< 0.35, P < 0.01, OR 3.51, CI 1.66 to 7.40), and having antibradycardia pacing ICDs (P = 0.02, OR 5.26, CI 1.37 to 20.0) to be independent predictors of sudden death. One or more predisposing factors and/or potential causes of sudden death were identified in 21 patients (28%). CONCLUSION: In this select group of transvenous ICD recipients, (1) sudden death was associated with ventricular tachycardia/ventricular fibrillation in at least two thirds of cases, (2) nearly one third of patients had one or more factors, some device related, that could have been associated with sudden death, and (3) death ensued despite appropriate ICD therapies and, in many cases, external resuscitation, suggesting acute adverse events as common terminal factors.

Aged↗

A hub dynamometer for measurement of wheel forces in off-road bicycling.

A dynamometric hubset that measures the two ground contact force components acting on a bicycle wheel in the plane of the bicycle during off-road riding while either coasting or braking was designed, constructed, and evaluated. To maintain compatibility with standard mountain bike construction, the hubs use commercially available shells with modified, strain gage-equipped axles. The axle strain gages are sensitive to forces acting in the radial and tangential directions, while minimizing sensitivity to transverse forces, steering moments, and variations in the lateral location of the center of pressure. Static calibration and a subsequent accuracy check that computed differences between applied and apparent loads developed during coasting revealed root mean squared errors of 1 percent full-scale or less (full-scale load = 4500 N). The natural frequency of the rear hub with the wheel attached exceeded 350 Hz. These performance capabilities make the dynamometer useful for its intended purpose during coasting. To demonstrate this usefulness, sample ground contact forces are presented for a subject who coasted downhill over rough terrain. The dynamometric hubset can also be used to determine ground contact forces during braking providing that the brake reaction force components are known. However, compliance of the fork can lead to high cross-sensitivity and corresponding large (> 5 percent FS) measurement errors at the front wheel.

Bicycling↗

Quantification of structural loading during off-road cycling.

To provide data for fatigue life prediction and testing of structural components in off-road bicycles, the objective of the research described herein was to quantify the loads input to an off-road bicycle as a result of surface-induced loads. A fully instrumented test bicycle was equipped with dynamometers at the pedals, handlebars, and hubs to measure all in-plane structural loads acting through points of contact between the bicycle and both the rider and the ground. A portable data acquisition system carried by the standing rider allowed, for the first time, this loading information to be collected during extended off-road testing. In all, seven experienced riders rode a downhill trial test section with the test bicycle in both front-suspension and full-suspension configurations. The load histories were used quantitatively to describe the load components through the computation of means, standard deviations, amplitude probability density functions, and power spectral density functions. For the standing position, the coefficients of variation for the load components normal to the ground were greater than 1.2 for handlebar forces and 0.3 and 0.5-0.6 for the pedal and hub forces, respectively. Thus, the relative contribution of the dynamic loading was much greater than the static loading at the handlebars but less so at the pedals and hubs. As indicated by the rainflow count, high amplitude loading was developed approaching 3 and 5 times the weight of the test subjects at the front and rear wheels, respectively. The power spectral densities showed that energy was concentrated in the band 0-50 Hz. Through stress computations and knowledge of material properties, the data can be used analytically to predict the fatigue life of important structural components such as those for steering. The data can also be used to develop a fatigue testing protocol for verifying analytical predictions of fatigue life.

Bicycling↗

Analysis of ankle deflection during a forward fall in snowboarding.

Toward the general goal of preventing ankle injuries in snowboarding accidents, the objective of this project to develop a dynamic system model of a snowboarder and assess which model parameters, particularly those attributed to the boot, most strongly influenced ankle deflections during a forward fall. To satisfy this objective, a system model was created that included the rider, the boots, the snowboard, and the snow as components. Through dynamic simulations, peak ankle deflections were computed over realistic ranges of input parameter values for each of the model components. Defining sensitivity as the total change in peak ankle deflection over the range of a particular parameter studied, results indicated that the peak ankle deflection was most sensitive to the boot stiffness. Although lower, the sensitivity of the peak ankle deflection to the snow model parameters was still significant, being roughly half of the boot sensitivity. Increases in both snow stiffness and snow damping caused higher ankle deflections. Variations in both snowboard stiffness and anthropometric parameters had little effect. Due to the strong dependence of ankle deflection on boot stiffness, the potential exists for mitigating the ankle injury problem through judicious design of the boot.

Accidental Falls↗

Can an isometer predict the tensile behavior of a double-looped hamstring graft during anterior cruciate ligament reconstruction?

An isometer, a highly compliant spring-scale device for measuring suture displacement, has been used intraoperatively by surgeons to select the optimal placement of the femoral tunnel for an anterior cruciate ligament graft. The isometer measures the displacement of a suture centered in a tibial tunnel and attached to an intraarticular location on the femur before the femoral tunnel is drilled. Because the placement of the femoral tunnel strongly impacts the tensile behavior of an anterior cruciate ligament graft and because surgeons have used the amount of suture displacement to guide the placement of the femoral tunnel, the objective of this study was to determine the ability of an isometer to predict graft tension. In 14 patients undergoing reconstructive surgery of the anterior cruciate ligament, an isometer was used to measure suture displacement during passive knee motion for a provisional femoral tunnel location. An electrogoniometer recorded the flexion angle of the knee. The femoral tunnel was drilled. A double-looped semitendinosus and gracilis autograft was inserted around a post in the femoral tunnel, and the tension in the four limbs of the graft exiting the tibial tunnel was measured during passive knee motion. Graft-tension versus knee-flexion-angle curves revealed that each knee exhibited one of two distinct curve shapes: L-shaped, characterized by the maximum tension occurring at full extension and a nearly flat profile from 35 to 90 degrees of flexion, or U-shaped, with elevated tensions at 80-90 degrees of flexion (p < 0.001) reaching at least half of the tension in full extension. Because the shapes of the suture-displacement versus flexion-angle curves were more consistently L-shaped, the intraoperative measurement of suture displacement was not a useful predictor of either the increase in tension in the graft with flexion or the maximum tension in the graft.

Adolescent↗

Quadriceps load aggravates and roofplasty mitigates active impingement of anterior cruciate ligament grafts against the intercondylar roof.

Because of the complications of impingement of anterior cruciate ligament grafts on the intercondylar roof and because current surgical procedures locate the tibial tunnel such that impingement is avoided during passive but not active extension, the objectives of this study were to determine if (a) active extension precipitates and aggravates roof impingement, and (b) a roofplasty mitigates the effects of impingement. The tibial translation, flexion angle defining the onset of roof impingement, graft-roof contact pressure, and graft tension were measured for six cadaveric specimens. In each specimen, two tibial tunnel positions were studied: one customized for the slope of the intercondylar roof, and the other translated 6 mm anteriorly from the customized position. For a quadriceps load of 1,500 N, the flexion angle defining the onset of impingement, the peak contact pressure, and the graft tension increased significantly for both tunnel positions. The increases occurred because of the anterior tibial translation caused by the active load. Although a roofplasty decreased the onset of the angle of impingement, the graft tension remained unaffected. Thus, to mitigate the effect of impingement during active rehabilitative knee extension exercises, the position of the tibial tunnel must be customized to the angle of the intercondylar roof and a roofplasty must be performed. The extent of bone removed must be customized as well and can be determined by removing bone from the intercondylar roof in excess of that required to freely pass a rod, the same diameter of the graft, through the tibial tunnel into the intercondylar notch with the knee in full passive extension.

Adult↗

Telemetry system for monitoring anterior cruciate ligament graft forces in vivo.

Quantifying changes in the tension of an anterior cruciate ligament (ACL) graft in vivo during rehabilitative exercises is useful for developing the optimum rehabilitation for patients who have had reconstructive surgery. The purpose of the work reported is to design, build and test a telemetry system that can measure the in vivo ACL graft tension post-operatively. A commercially available fixation device is modified to sense the graft tension, house electronic components, transmit an output signal and pass the power generating signal. A transcutaneous inductive link is used to power the implanted telemetry electronics. The current difference technique is used to measure changes in two resistance strain gauges that monitor shear strain developed on the femoral fixation device by the ACL graft. This current regulates a frequency-modulated output signal that is transmitted using a new technique. Harnessing the ionic and volume conduction properties of the body fluids, the new technique involves injecting current subcutaneously into the tissue and then sensing the potential developed on the skin by surface electrodes. The waveform shape, amount of charge injected, charge density and current density are regulated to avoid tissue damage, pain and unwanted muscular stimulation. A signal conditioning board detects and converts the output to an analogue voltage for collection by a computer data-acquisition system. A performance evaluation demonstrates that the telemetry system either meets or exceeds all of the criteria necessary for the application.

Anterior Cruciate Ligament↗

A high-accuracy three-dimensional coordinate digitizing system for reconstructing the geometry of diarthrodial joints.

This paper describes the design and performance evaluation of a three-dimensional (3-D) coordinate digitizing system (3-DCDS) for measuring both soft and hard biological tissue. The system incorporates a visible semiconducting laser beam and an X-Y positioning table to directly measure 3-D coordinates that define surface points. Experiments conducted to evaluate the performance of the system showed that it delivers an accuracy of 0.1 microm in the Z-direction and 1.4 microm in the X-Y plane, and an overall system root-mean-squared error (RMSE) of 8 microm on surfaces with slopes of less than 45 degrees . This error is lower than that of previously reported measurement techniques. The 3-DCDS measures 3-D coordinates of surface points uniformly separated by 500 microm in the X-Y plane. Because the 3-DCDS is automated, the coordinates are measured efficiently and the accuracy is independent of operator skill. These highly accurate coordinates can be easily incorporated into nodal values for 3-D finite element models (FEM) of diarthrodial joints. To show the use of the 3-DCDS, the 3-D surface coordinates of human menisci were measured from a cadaver specimen.

Cadaver↗

The effect of intersegmental knee moments on patellofemoral contact mechanics in cycling.

The aim of this study was to evaluate the effect of bicycle pedal design on the mechanics of the patellofemoral joint. Previous research determined that for certain riders the non-driving varus and internal knee moments could be reduced by switching from fixed to free floating pedals (Ruby and Hull, 1993). It was postulated that the presence of varus and internal knee moments during fixed pedal cycling may adversely affect patellofemoral joint contact mechanics which could lead to the development of anterior knee pain. To investigate the effect of pedal design the hypothesis that varus and internal intersegmental knee moments significantly increase patellofemoral contact pressure, contact area and contact force was tested. To test this hypothesis cycling loads were simulated in vitro using a six-degree-of-freedom load application system (LAS). Using the LAS, varus moments ranging from 0-20 Nm and internal knee moments ranging from 0-10 Nm were applied simultaneously with quadriceps force at knee flexion angles of 60 and 90 degrees. Patellofemoral contact patterns were measured using pressure sensitive film. An applied 10 Nm internal moment significantly increased both contact area by 16% and contact force by 22% at 90 of flexion. The application of a 20 Nm varus moment modestly yet significantly increased contact area by 6% and contact force by 5%. When applied in combination, varus and internal knee moments increased contact area and force by as much as 29% and 28% respectively. The mean contact pressure was not significantly increased by either of the two moments. The results suggest that non-driving intersegmental knee moments subject the patellofemoral joint to loads and contact patterns which may accelerate the development of chondromalacia.

Aged↗

The effect of recombinant follicle stimulating hormone (Gonal-F) on endogenous luteinizing hormone secretion in women.

Parenteral administration of follicle stimulating hormone (FSH) has been shown to lower luteinizing hormone (LH) concentrations in women undergoing ovulation induction. This study was designed to explore the physiological mechanism of this effect. Seven healthy women were recruited into a double-blind placebo-controlled study. LH secretion, after the administration of variable i.v. boluses (37.5, 75 and 150 IU) of recombinant FSH (Gonal-F), was evaluated. LH was measured at 10 min intervals for 2 h before and 4 h after the FSH/placebo infusion. LH pulse frequency and amplitude were evaluated and there was no significant difference between control and trial cycles for each subject. A linear regression analysis revealed that in the group receiving 150 IU FSH, the mean plasma LH concentration decreased significantly due to a reduction tonic LH secretion. This could be a result of the suppression of secretion or an alteration of clearance. This decrease was not seen in the other dosage groups, revealing that above a dosage threshold, FSH reduced non-pulsatile LH secretion. Therefore the effect of FSH in this study exposed the likely presence of two components of LH concentration: an FSH-sensitive, non-pulsatile tonic secretion and a gonadotrophin-releasing hormone-stimulated, pulsatile release that is unaffected by FSH. Although an indirect effect involving ovarian regulation is not excluded, the rapidity of the effect suggests that FSH acts directly on the pituitary gland.

Adult↗

A new technique for transmission of signals from implantable transducers.

To reduce space requirements for implant electronics in in vivo telemetry applications, the purpose of this project was to develop and test a new data transmission method that utilizes the ionic properties of bodily fluids as the transmission medium. Motivated by an interest in using the new method to transmit information from a sensor which measures tension in anterior cruciate ligament (ACL) grafts, a sine wave was injected into a cadaver leg using platinum electrodes implanted into the lateral femoral epicondyle. The signal was detected by electromyogram (EMG) surface electrodes. The effect of transmission frequency, the current injected, interelectrode separation, distance of the electrodes from the joint line, and the surface of electrode placement on the signal attenuation was studied. The logarithmic relation between attenuation and frequency was constant from 2 kHz until 10 kHz. For frequencies above 10 kHz, the attenuation increased linearly at the rate of 1 dB/octave. Attenuation was inversely sensitive to both current and interelectrode separation with larger separations and currents giving less attenuation. Attenuation was significantly less for the lateral thigh surface than for the anterior surface and increased with increasing distance from the joint line for both surfaces. For the application of interest here, suitable values of transmission variables to avoid the possible negative consequences of injecting current into living tissue are a current of 3 mA injected at a frequency of 37 kHz. The values of reception variables for minimum attenuation are wide interelectrode separation (5 cm) with the electrodes placed 5 cm proximal of the joint line on the lateral surface of the thigh. With the exception of the surface which is application dependent, these values of the reception variables should also be appropriate for other applications.

Anterior Cruciate Ligament↗

An implantable transducer for measuring tension in an anterior cruciate ligament graft.

The goal of this study was to develop a new implantable transducer for measuring anterior cruciate ligament (ACL) graft tension postoperatively in patients who have undergone ACL reconstructive surgery. A unique approach was taken of integrating the transducer into a femoral fixation device. To devise a practical in vivo calibration protocol for the fixation device transducer (FDT), several hypotheses were investigated: (1) The use of a cable versus the actual graft as the means for applying load to the FDT during calibration has no significant effect on the accuracy of the FDT tension measurements; (2) the number of flexion angles at which the device is calibrated has no significant effect on the accuracy of the FDT measurements; (3) the friction between the graft and femoral tunnel has no significant effect on measurement accuracy. To provide data for testing these hypotheses, the FDT was first calibrated with both a cable and a graft over the full range of flexion. Then graft tension was measured simultaneously with both the FDT on the femoral side and load cells, which were connected to the graft on the tibial side, as five cadaver knees were loaded externally. Measurements were made with both standard and overdrilled tunnels. The error in the FDT tension measurements was the difference between the graft tension measured by the FDT and the load cells. Results of the statistical analyses showed that neither the means of applying the calibration load, the number of flexion angles used for calibration, nor the tunnel size had a significant effect on the accuracy of the FDT. Thus a cable may be used instead of the graft to transmit loads to the FDT during calibration, thus simplifying the procedure. Accurate calibration requires data from just three flexion angles of 0, 45, and 90 deg and a curve fit to obtain a calibration curve over a continuous range of flexion within the limits of this angle group. Since friction did not adversely affect the measurement accuracy of the FDT, the femoral tunnel can be drilled to match the diameter of the graft and does not need to be overdrilled. Following these procedures, the error in measuring graft tension with the FDT averages less than 10 percent relative to a full-scale load of 257 N.

Aged↗

Evaluation of performance criteria for simulation of submaximal steady-state cycling using a forward dynamic model.

The objectives of this study were twofold. The first was to develop a forward dynamic model of cycling and an optimization framework to simulate pedaling during submaximal steady-state cycling conditions. The second was to use the model and framework to identify the kinetic, kinematic, and muscle timing quantities that should be included in a performance criterion to reproduce natural pedaling mechanics best during these pedaling conditions. To make this identification, kinetic and kinematic data were collected from 6 subjects who pedaled at 90 rpm and 225 W. Intersegmental joint moments were computed using an inverse dynamics technique and the muscle excitation onset and offset were taken from electromyographic (EMG) data collected previously (Neptune et al., 1997). Average cycles and their standard deviations for the various quantities were used to describe normal pedaling mechanics. The model of the bicycle-rider system was driven by 15 muscle actuators per leg. The optimization framework determined both the timing and magnitude of the muscle excitations to simulate pedaling at 90 rpm and 225 W. Using the model and optimization framework, seven performance criteria were evaluated. The criterion that included all of the kinematic and kinetic quantities combined with the EMG timing was the most successful in replicating the experimental data. The close agreement between the simulation results and the experimentally collected kinetic, kinematic, and EMG data gives confidence in the model to investigate individual muscle coordination during submaximal steady-state pedaling conditions from a theoretical perspective, which to date has only been performed experimentally.