Search PubMed⌕ Search

Biomedical subjects

M L Hull

Publications and source records attributed to M L Hull.

At least 19 recordsLinked to original sources

Sloped muscle excitation waveforms improve the accuracy of forward dynamic simulations.

Mathematical models of the muscle excitation are useful in forward dynamic simulations of human movement tasks. One objective was to demonstrate that sloped as opposed to rectangular excitation waveforms improve the accuracy of forward dynamic simulations. A second objective was to demonstrate the differences in simulated muscle forces using sloped versus rectangular waveforms. To fulfill these objectives, surface EMG signals from the triceps brachii and elbow joint angle were recorded and the intersegmental moment of the elbow joint was computed from 14 subjects who performed two cyclic elbow extension experiments at 200 and 300 deg/s. Additionally, the surface EMG signals from the leg musculature, joint angles, and pedal forces were recorded and joint intersegmental moments were computed during a more complex pedaling task (90 rpm at 250 W). Using forward dynamic simulations, four optimizations were performed in which the experimental intersegmental moment was tracked for the elbow extension tasks and four optimizations were performed in which the experimental pedal angle, pedal forces, and joint intersegmental moments were tracked for the pedaling task. In these optimizations the three parameters (onset and offset time, and peak excitation) defining the sloped (triangular, quadratic, and Hanning) and rectangular excitation waveforms were varied to minimize the difference between the simulated and experimentally tracked quantities. For the elbow extension task, the intersegmental elbow moment root mean squared error, onset timing error, and offset timing error were less from simulations using a sloped excitation waveform compared to a rectangular excitation waveform (p<0.001). The average and peak muscle forces were from 7% to 16% larger and 20-28% larger, respectively, when using a rectangular excitation waveform. The tracking error for pedaling also decreased when using a sloped excitation waveform, with the quadratic waveform generating the smallest tracking errors for both tasks. These results support the use of sloped over rectangular excitation waveforms to establish greater confidence in the results of forward dynamic simulations.

Computer Simulation↗

Is economy of competitive cyclists affected by the anterior-posterior foot position on the pedal?

The primary purpose of this investigation was to test the hypothesis that cycling economy, as measured by rate of oxygen consumption (VO(2)) in healthy, young, competitive cyclists pedaling at a constant workrate, increases (i.e. VO(2) decreases) when the attachment point of the foot to the pedal is moved posteriorly on the foot. The VO(2) of 11 competitive cyclists (age 26.8+/-8.9 years) was evaluated on three separate days with three anterior-posterior attachment points of the foot to the pedal (forward=traditional; rear=cleat halfway between the head of the first metatarsal and the posterior end of the calcaneous; and mid=halfway between the rear and forward positions) on each day. With a randomly selected foot position, VO(2) was measured as each cyclist pedaled at steady state with a cadence of 90 rpm and with a power output corresponding to approximately 90% of their ventilatory threshold (VT) (mean power output 203.3+/-20.8 W). After heart rate returned to baseline, VO(2) was measured again as the subject pedaled with a different anterior-posterior foot position, followed by another rest period and then VO(2) was measured at the final foot position. The key finding of this investigation was that VO(2) was not affected by the anterior-posterior foot position either for the group (p=0.311) or for any individual subject (p>or=0.156). The VO(2) for the group was 2705+/-324, 2696+/-337, and 2747+/-297 ml/min for the forward, mid, and rear foot positions, respectively. The practical implication of these findings is that adjusting the anterior-posterior foot position on the pedal does not affect cycling economy in competitive cyclists pedaling at a steady-state power output eliciting approximately 90% of VT.

Adult↗

Does a tensioning device pinned to the tibia improve knee anterior-posterior load-displacement compared to manual tensioning of the graft following anterior cruciate ligament reconstruction? A cadaveric study of two tibial fixation devices.

Devices that are pinned to the tibia to tension an anterior cruciate ligament (ACL) graft produce joint reaction loads that in turn can affect the maintenance of graft initial tension after tibial fixation and hence knee anterior-posterior (AP) load-displacement. However, the effect of these devices on AP load-displacement is unknown. Our objectives were to determine whether tensioning by device versus tensioning by hand causes differences in AP load-displacement and intraarticular graft tension for two commonly used tibial fixation devices: a bioresorbable interference screw and a WasherLoc. AP load-displacement and intraarticular graft tension were measured in 20 cadaveric knees using a custom arthrometer. An initial tension of 110 N was applied to a double-looped tendon graft with the knee at extension using a tensioning device pinned to the tibia and a simulated method of tensioning by hand. After inserting the tibial fixation device, the 134 N anterior limit (i.e., anterior position of the tibia with respect to the femur with a 134 N anterior force applied to the tibia) and 0 N posterior limit (i.e., AP position of the tibia relative to the femur with a 0 N force applied to the tibia) were measured with the knee in 25 degrees flexion. Intraarticular graft tension was measured at extension. These limits and intraarticular graft tension were also measured after cyclically loading the knee 300 times. Compared to a simulated method of tensioning by hand, tensioning with a device pinned to the tibia did not decrease the 134 N anterior limit and did not cause posterior tibial translation. However, intraarticular graft tension was maintained better with a tensioning device pinned to the tibia for the Washerloc, but not the interference screw. For two commonly used tibial fixation devices, a tensioning device pinned to the tibia does not improve AP load-displacement at 25 degrees flexion over tensioning by hand when the graft is tensioned at full extension, but does improve the maintenance of intraarticular graft tension for the Washerloc.

Absorbable Implants↗

Lengthening of a single-loop tibialis tendon graft construct after cyclic loading: a study using Roentgen stereophotogrammetric analysis.

Although single-loop tibialis tendon allografts have increased in popularity owing to their many advantages over patellar tendon and double-loop hamstring tendon autografts, some percentage of the patient population do not have clinically stable knees following anterior cruciate ligament reconstruction with single-loop tibialis tendon allografts. Therefore, it would be advantageous to determine the causes of increased anterior laxity which ultimately must be traced to lengthening of the graft construct. One objective of this study was to demonstrate the feasibility of using Roentgen stereophotogrammetric analysis (RSA) to determine the causes of lengthening of a single-loop graft construct subjected to cyclic loading. A second objective was to determine which cause(s) contributes most to an increase in length of this graft construct. Radio-opaque markers were inserted into ten grafts to measure the lengthening at the sites of the tibial and femoral fixations and between the sites of fixation. Each graft was passed through a tibial tunnel in a calf tibia, looped around a rigid cross-pin, and fixed to the tibia with a Washerloc fixation device. The grafts were cyclically loaded for 225,000 cycles from 20 to 170 N. Prior to and at intervals during the cyclic loading, simultaneous radiographs were taken. RSA was used to determine the three-dimensional coordinates of the markers from which the lengthening at the sites of fixation and between the sites of fixation was computed at each interval. The sites of the femoral and tibial fixations were the largest contributors to the increase in length of the graft construct, with maximum average values of 0.68 and 0.55 mm, respectively, after 225,000 cycles. The graft substance between the sites of fixation contributed least to lengthening of the graft, with a maximum average value of 0.31 mm. Ninety percent of the maximum average values occurred before 100,000 cycles of loading for the largest contributors. RSA proved to be a useful method for measuring lengthening due to all three causes. Lengthening of the graft construct at the sites of both fixations is sufficiently large that the combined contributions may manifest as a clinically important increase in anterior laxity.

Animals↗

How changing the inversion/eversion foot angle affects the nondriving intersegmental knee moments and the relative activation of the vastii muscles in cycling.

Nondriving intersegmental knee moment components (i.e., varus/valgus and internal/external axial moments) are thought to be primarily responsible for the etiology of overuse knee injuries such as patellofermoral pain syndrome in cycling because of their relationship to muscular imbalances. However the relationship between these moments and muscle activity has not been studied. Thus the four primary objectives of this study were to test whether manipulating the inversion/eversion foot angle alters the varus/valgus knee moment (Objective 1) and axial knee moment (Objective 2) and to determine whether activation patterns of the vastus medialis oblique (VMO), vastus lateralis (VL), and tensor fascia latae (TFL) were affected by changes in the varus/valgus (Objective 3) and axial knee moments (Objective 4). To fulfill these objectives, pedal loads and lower limb kinematic data were collected from 15 subjects who pedaled with five randomly assigned inversion/eversion angles: 10 deg and 5 deg everted and inverted and 0 deg (neutral). A previously described mathematical model was used to compute the nondriving intersegmental knee moments throughout the crank cycle. The excitations of the VMO, VL, and TFL muscles were measured with surface electromyography and the muscle activations were computed. On average, the 10-deg everted position decreased the peak varus moment by 55% and decreased the peak internal axial moment by 53% during the power stroke (crank cycle region where the knee moment is extensor). A correlation analysis revealed that the VMO/VL activation ratio increased significantly and the TFL activation decreased significantly as the varus moment decreased. For both the VMO/VL activation ratio and the TFL activation, a path analysis indicated that the varus/valgus moment was highly correlated to the axial moment but that the correlation between muscle activation and the varus moment was due primarily to the varus/valgus knee moment rather than the axial knee moment. The conclusion from these results is that everting the foot may be beneficial towards either preventing or ameliorating patellofemoral pain syndrome in cycling.

Adaptation, Physiological↗

Empirical relationship between lengthening an anterior cruciate ligament graft and increases in knee anterior laxity: a human cadaveric study.

Lengthening of an anterior cruciate ligament (ACL) graft construct can occur as a result of lengthening at the sites of tibial and/or femoral fixation and manifests as an increase in anterior laxity. Although lengthening at the site of fixation has been measured for a variety of fixation devices, it is difficult to place these results in a clinical context because the mathematical relationship between lengthening of an ACL graft construct and anterior laxity is unknown. The purpose of our study was to determine empirically this relationship. Ten cadaveric knees were reconstructed with a double-looped tendon graft. With the knee in 25 degrees of flexion, the position of the proximal end of the graft inside the femoral tunnel was adjusted by moving the femoral fixation device until the anterior laxity at an applied anterior force of 134 N matched that of the intact knee. In random order, the graft construct was lengthened 1, 2, 3, 4, and 5 mm by moving the femoral fixation device distally along the femoral tunnel and anterior laxity was measured. The increase in the length of the graft construct was related to the increase in anterior laxity by a simple linear regression model. Lengthening the graft construct from 1 to 5 mm caused an equal increase in anterior laxity (slope=1.0 mmmm, r(2)=0.800, p<0.0001). Because an anterior laxity increase of 3 mm or greater in a reconstructed knee is considered unstable clinically and because many fixation devices in widespread use clinically allow 3 mm or greater of lengthening in in vitro tests, our empirical relationship indicates that lengthening at the site of fixation probably is an important cause of knee instability following ACL reconstructive surgery. Our empirical relation also indicates that an important criterion in the design of future fixation devices is that lengthening at the sites of fixation in in vitro tests should be limited to less than 3 mm.

Aged↗

Heterogeneous three-dimensional strain fields during unconfined cyclic compression in bovine articular cartilage explants.

Articular cartilage provides critical load-bearing and tribological properties to the normal function of diarthrodial joints. The unique properties of cartilage, as well as heterogeneous deformations during mechanical compression, are due to the nonuniform microstructural organization of tissue components such as collagens and proteoglycans. A new cartilage deformation by tag registration (CDTR) technique has been developed by the authors to determine heterogeneous deformations in articular cartilage explants. The technique uses a combination of specialized MRI methods, a custom cyclic loading apparatus, and image processing software. The objective of this study was to use the CDTR technique to document strain patterns throughout the volume of normal bovine articular cartilage explants during cyclic unconfined compression at two physiologically-relevant applied normal stress levels (1.29 and 2.57 MPa). Despite simple uniaxial cyclic compressive loading with a flat, nonporous indenter, strain patterns were heterogeneous. Strains in the thickness direction (E(yy)) were compressive, varied nonlinearly with depth from the articular surface from a maximum magnitude of 11% at the articular surface, and were comparable despite a 2-fold increase in applied normal stress. Strains perpendicular to the thickness direction (E(xx) and E(zz)) were tensile, decreased linearly with depth from the articular surface from a maximum of 7%, and increased in magnitude 2.5-fold with a 2-fold increase in applied normal stress. Shear strains in the transverse plane (E(xz)) were approximately zero while shear strains in the other two planes were much larger and increased in magnitude with depth from the articular surface, reaching maximum magnitudes of 2% at the articular cartilage-subchondral bone interface. In general, strain patterns indicated that cartilage osteochondral explants exhibited depth-dependent nonisotropic behavior during uniaxial cyclic loading. These results are useful in verifying constitutive formulations of articular cartilage during cyclic unconfined compression and in characterizing the micromechanical environment likely experienced by individual chondrocytes throughout the tissue volume.

Animals↗

MRI-based technique for determining nonuniform deformations throughout the volume of articular cartilage explants.

Articular cartilage is critical to the normal function of diarthrodial joints. Despite the importance of the tissue and the prevalence of cartilage degeneration (e.g., osteoarthritis), the technology required to noninvasively describe nonuniform deformations throughout the volume of the tissue has not been available until recently. The objectives of the work reported in this paper were to 1) describe a noninvasive technique (termed the cartilage deformation by tag registration (CDTR) technique) to determine nonuniform deformations in articular cartilage explants with the use of specialized MRI tagging and image processing methods, 2) evaluate the strain error of the CDTR technique using a custom MRI-compatible phantom material, and 3) demonstrate the applicability of the CDTR technique to articular cartilage by determining 3D strain fields throughout the volume of a bovine articular cartilage explant. A custom MRI pulse sequence was designed to tag and image articular cartilage explants at 7 Tesla in undeformed and deformed states during the application of multiple load cycles. The custom pulse sequence incorporated the "delays alternating with nutations for tailored excitation" (DANTE) pulse sequence to apply tags. This was followed by a "fast spin echo" (FSE) pulse sequence to create images of the tags. The error analysis using the phantom material indicated that deformations can be determined with an error, defined as the strain precision, better than 0.83% strain. When this technique was applied to a single articular cartilage explant loaded in unconfined compression, hetereogeneous deformations throughout the volume of the tissue were evident. This technique potentially can be applied to determine normal cartilage deformations, analyze degenerated cartilage, and evaluate cartilage surgical repair and treatment methodologies. In addition, this technique may be applied to other soft tissues that can be appropriately imaged by MR.

Animals↗

Error optimization of a three-dimensional magnetic resonance imaging tagging-based cartilage deformation technique.

Three-dimensional strain fields in articular cartilage subjected to compressive loading can be determined using a recently developed MRI-based cartilage deformation by tag registration technique. The objective of this study was to determine the experimental variables that minimize the technique error, which has not been previously reported. Error (strain bias and precision) was determined using direct experiments and Monte Carlo simulations for four variables: spatial resolution, tag line spacing, applied nominal strain, and number of control points used to describe tag lines in a B-spline model. The important results include the following: (1) bias was not significantly different from zero, (2) precision increased with image resolution and with tag line spacing, (3) precision was independent of applied nominal strain, and (4) error was a minimum (absolute precision = 0.41% strain) for the following values: spatial resolution = 0.05 x 0.05 mm2; tag line spacing = 2.0 mm; control points = 6. With these results the technique can now be used in various applications while minimizing error.

Algorithms↗

Tension in a double loop tendon anterior cruciate graft during a simulated open chain knee extension exercise.

Concerns exist regarding the tension developed in a reconstructed anterior cruciate ligament (ACL) during open chain knee extension exercises used to rehabilitate the knee. Therefore, the primary objective was to measure tension in an ACL graft during a simulated open chain knee extension exercise as a function of ankle weight. A secondary objective was to determine whether the graft tension was reduced with relatively high stiffness fixation. The open chain exercise was simulated in seven cadaveric specimens in which the ACL had been reconstructed with double loop tendon grafts. Graft tension was measured at 15 degrees of flexion as the effective ankle weight was increased from 22.5 to 67.5 and then to 112.5 N for three different fixation stiffnesses (25, 125, and 225 N/mm). The initial tension was set to restore the 225 N anterior limit of motion to that of the intact knee at 30 degrees of flexion. Increasing the ankle weight caused the graft tension to increase significantly (p<0.0001), but the increase with the highest ankle weight was only 62 N on average. Increasing the fixation stiffness caused the graft tension to decrease significantly (p<0.0001) because the initial tension decreased by 107 N as the fixation stiffness increased. Because the graft tension with the highest ankle weight was limited to 112 N on average, high stiffness fixation methods, which are also resistant to lengthening in the region of the fixation, may reduce the risk of graft construct lengthening during open chain knee extension exercises.

Aged↗

A new tibial coordinate system improves the precision of anterior-posterior knee laxity measurements: a cadaveric study using Roentgen stereophotogrammetric analysis.

Roentgen stereophotogrammetric analysis (RSA) can be used to measure changes in anterior-posterior (A-P) knee laxity after anterior cruciate ligament (ACL) reconstruction. Previous measurements of A-P knee laxity using RSA have employed a tibial coordinate system with the origin placed midway between the tips of the tibial-eminences. However, the precision in measuring A-P knee laxity might be improved if the origin was placed on the flexion-extension axis of rotation of the knee. The purpose of this study was to determine whether a center-of-rotation tibial coordinate system with the origin placed midway between the centers of the posterior femoral condyles, which closely approximates the flexion-extension center-of-rotation of the knee, improves the precision in measuring A-P knee laxity compared to the tibial-eminence-based coordinate system. A-P knee laxity was measured using each coordinate system six times in three human cadaveric knees implanted with 0.8-mm diameter tantalum markers. For each laxity measurement, the knee was placed in a custom loading apparatus and biplanar radiographs were obtained while the knee resisted a 44 N posterior shear force and 136 N anterior shear force. A-P knee laxity was determined from the change in position of the tibia, with respect to the femur, resulting from the posterior and anterior shear forces. The precision for each coordinate system was calculated as the pooled standard deviation of A-P knee laxity measurements. The precision of the center-of-rotation coordinate system was 0.33 mm, which was about a factor of 2 better than the 0.62 mm precision of the tibial-eminence coordinate system (p=0.006). The 0.33 mm precision with the center-of-rotation coordinate system suggests that an observed change of either 0.56 mm (i.e. 1.7 standard deviations) or greater in A-P knee laxity over time is a real change and not due to measurement error when the new tibial coordinate system is used and other factors contributing to variability are controlled as was done in this study. Accordingly, clinicians and researchers should consider the use of this alternate tibial coordinate system when making serial measurements of A-P knee laxity using RSA because the improved precision allows for the observation of smaller differences.

Adult↗

Functional roles of the leg muscles when pedaling in the recumbent versus the upright position.

An understanding of the coordination of the leg muscles in recumbent pedaling would be useful to the design of rehabilitative pedaling exercises. The objectives of this work were to (i) determine whether patterns of muscle activity while pedaling in the recumbent and upright positions are similar when the different orientation in the gravity field is considered, (ii) compare the functional roles of the leg muscles while pedaling in the recumbent position to the upright position to the upright position and (iii) determine whether leg muscle onset and offset timing for recumbent and upright pedaling respond similarly to changes in pedaling rate. To fulfill these objectives, surface electromyograms were recorded from 10 muscles of 15 subjects who pedaled in both the recumbent and upright positions at 75, 90, and 105 rpm and at a constant workrate of 250 W. Patterns of muscle activation were compared over the crank cycle. Functional roles of muscles in recumbent and upright pedaling were compared using the percent of integrated activation in crank cycle regions determined previously for upright pedaling. Muscle onset and offset timing were also compared. When the crank cycle was adjusted for orientation in the gravity field, the activation patterns for the two positions were similar. Functional roles of the muscles in the two positions were similar as well. In recumbent pedaling, the uniarticular hip and knee extensors functioned primarily to produce power during the extension region of the crank cycle, whereas the biarticular muscles crossing the hip and knee functioned to propel the leg through the transition regions of the crank cycle. The adaptations of the muscles to changes in pedaling rate were also similar for the two body positions with the uniarticular power producing muscles of the hip and knee advancing their activity to earlier in the crank cycle as the pedaling rate increased. This information on the functional roles of the leg muscles provides a basis by which to form functional groups, such as power-producing muscles and transition muscles, to aid in the development of rehabilitative pedaling exercises and recumbent pedaling simulations to further our understanding of task-dependent muscle coordination.

Adaptation, Physiological↗

Migration of radio-opaque markers injected into tendon grafts: a study using roentgen stereophotogrammetric analysis (RSA).

An increase in anterior laxity following reconstruction of the anterior cruciate ligament (ACL) can result from lengthening of the graft construct either at the sites of fixation and/or between the sites of fixation (i.e., graft substance). Roentgen stereophotogrammetric analysis (RSA), which requires that radio-opaque markers be attached to the graft, has been shown to be a useful technique in determining lengthening in these regions. Previous methods have been used for attaching radio-opaque markers to the graft, but they all have limitations particularly for single-loop grafts. Therefore, the objective of this study was to evaluate injecting markers directly into the substance of a tendon as a viable method for measuring lengthening of single-loop graft constructs by determining the maximum amount of migration after cyclic loading. Tantalum spheres of 0.8 mm diameter were used as tendon markers. Ten single-loop tendon grafts were passed through tibial tunnels drilled in calf tibias and fixed with a tibial fixation device. Two tendon markers were inserted in one tendon bundle of each graft and the grafts were cyclically loaded for 225,000 cycles from 20 N to 170 N. At specified intervals, simultaneous radiographs were obtained of the tendon markers. Marker migration was computed as the change in distance between the two tendon markers parallel to the axis of the tibial tunnel. Marker migration had a root mean square (RMS) value of less than 0.1 mm. Because the RMS value indicates the error introduced into measurements of lengthening and because this error is negligible, the method described for attaching markers to single-loop ACL grafts has the potential to be useful for determining lengthening of single-loop ACL graft constructs in in vivo studies in humans.

Animals↗

Are the maximum shortening velocity and the shape parameter in a Hill-type model of whole muscle related to activation?

Mathematical models of the inter-relationship of muscle force, velocity, and activation are useful in forward dynamic simulations of human movement tasks. The objective of this work was to determine whether the parameters (maximum shortening velocity V(max) and shape parameter k) of a Hill-type muscle model, interrelating muscle force, velocity, and activation, are themselves dependent on the activation. To fulfill this objective, surface EMG signals from four muscles, as well as the kinematics and kinetics of the arm, were recorded from 14 subjects who performed rapid-release elbow extension tasks at 25%, 50%, 75%, and 100% activation (MVC). The experimental elbow flexion angle was tracked by a forward dynamic simulation of the task in which V(max) and k of the triceps brachii were varied at each activation level to minimize the difference between the simulated and experimental elbow flexion angle. Because a preliminary analysis demonstrated no dependency of k on activation, additional simulations were performed with constant k values of 0.15, 0.20, and 0.25. The optimized values of V(max) normalized to the average value within a subject were then regressed onto the activation. Normalized V(max) depended significantly on the activation (p<0.001) for all values of k. Furthermore, the estimated V(max) values were not sensitive to the selected k value. The results support the use of Hill-type models in which V(max) depends on activation in forward dynamic simulations modeling muscles with mixed fiber-type composition recruited in the range of 25-100% activation. The use of more accurate models will lend greater confidence to the results of forward dynamic simulations.

Adult↗

Nimesulide, a COX-2 inhibitor, does not reduce lesion size or number in a nude mouse model of endometriosis.

BACKGROUND: Women with endometriosis have elevated levels of cyclooxygenase-2 (COX-2) in peritoneal macrophages and endometriotic tissue. Inhibition of COX-2 has been shown to reduce inflammation, angiogenesis and cellular proliferation. It may also downregulate aromatase activity in ectopic endometrial lesions. Ectopic endometrial establishment and growth are therefore likely to be suppressed in the presence of COX-2 inhibitors. We hypothesized that COX-2 inhibition would reduce the size and number of ectopic human endometrial lesions in a nude mouse model of endometriosis. METHODS: The selective COX-2 inhibitor, nimesulide, was administered to estrogen-supplemented nude mice implanted with human endometrial tissue. Ten days after implantation, the number and size of ectopic endometrial lesions were evaluated and compared with lesions from a control group. Immunohistochemical assessment of vascular development and macrophage and myofibroblast infiltration in control and treated lesions was performed. RESULTS: There was no difference in the number or size of ectopic endometrial lesions in control and nimesulide-treated nude mice. Nimesulide did not induce a visually identifiable difference in blood vessel development or macrophage or myofibroblast infiltration in nude mouse explants. CONCLUSION: The hypothesized biological properties of COX-2 inhibition did not influence lesion number or size in the nude mouse model of endometriosis.

Adult↗

How the fixation method stiffness and initial tension affect anterior load-displacement of the knee and tension in anterior cruciate ligament grafts: a study in cadaveric knees using a double-loop hamstrings graft.

There were two objectives to this study. The first was to investigate the relationship of graft fixation stiffness and graft initial tension on the anterior load-displacement behavior of knees reconstructed with a double-loop hamstrings tendon graft. The second was to determine the corresponding graft tensions at 225 N of anterior force applied to the knee. To satisfy these objectives, the anterior-load displacement curves were measured for seven cadaveric knees with the ACL intact at flexion angles ranging from 0 degrees to 90 degrees. The ACL was reconstructed in the same knees using a double-loop hamstrings graft. A/P load-displacement curves of the knee and graft tension were measured as the fixation method stiffness and the initial tension applied at full extension were varied (25-326 N/mm and 25-300 N). The 0 N posterior limit (unloaded position of tibia) and the anterior laxity (difference between the 0 N posterior limit and 225 N anterior limit) were computed to characterize the A/P load-displacement of the intact and reconstructed knees. The key results were that the 0 N posterior limit of the tibia was insensitive to changes in stiffness (p>0.6503) but that increasing initial tension caused increasing posterior subluxation of the tibia with respect to the femur (p=0.0001). The tibia was subluxed posteriorly by 5-6 mm on average at high levels of initial tension. Both initial tension and stiffness significantly affected the anterior laxity (p=0.0001 for both factors). Anterior laxity was restored closely to normal (i.e. <1 mm difference) by relatively high initial tension of 200 N in combination with low stiffness of 25 N/mm and by low initial tension of 25 N in combination with higher stiffness ranging between 94 and 326 N/mm. When anterior laxity is restored to normal using a high initial tension-low stiffness combination however, the tibia undergoes a large posterior subluxation with respect to the femur in the unloaded state (approximately 5 mm) and a relatively high graft tension of 275 N is developed at 225 N of anterior force. Both the tibial subluxation and graft tension are reduced substantially with low initial tension-higher stiffness combinations because the amount of initial tension required to restore anterior laxity to normal is reduced by about 200 N.

Aged↗

Lengthening of double-looped tendon graft constructs in three regions after cyclic loading: a study using Roentgen stereophotogrammetric analysis.

Lengthening of a double-looped tendon graft construct used to reconstruct the anterior cruciate ligament (ACL) can result in an increase in anterior knee laxity and affect the stability of the reconstructed knee. Three possible regions where lengthening of the construct can occur are (1) the region of the tibial fixation, (2) the region of the femoral fixation, and (3) the region of the graft between the fixations. One objective of this study was to demonstrate the feasibility of using Roentgen stereophotogrammetric analysis (RSA) to determine the lengthening in each region of a double-looped graft construct subjected to cyclic loading. A second objective was to determine which region(s) contributes most to an increase in length of this graft construct. Radio-opaque markers were attached to ten grafts to measure the lengthening in each of the three regions. Each graft was passed through a tibial tunnel in a bovine tibia, looped around a rigid cross-pin, and fixed to the tibia with a Washerloc fixation device. The grafts were cyclically loaded for 225,000 cycles from 20 to 170 N. Prior to and at intervals during the cyclic loading, simultaneous radiographs were taken of the tibia and graft. RSA was used to determine the 3-dimensional coordinates of the markers from which the lengthening in each region was computed at each interval. The regions of the tibial and femoral fixations were the largest contributors to the increase in length of the graft, with maximum average values of 0.91 and 0.76 mm respectively after 225,000 cycles. The region between the fixations contributed least to lengthening of the graft, with a maximum average value of 0.23 mm. More than 90% of the lengthening in each region occurred before 100,000 cycles of loading. RSA proved to be a useful method for measuring lengthening in all three regions of the graft construct. Lengthening of the graft construct in both regions of fixation is sufficiently large that the combined contributions may cause a recurrence of instability in some knees.

Animals↗