Modeling of damage to articulating surfaces by third body particles in total joint replacements.

Numerous small scratches and some larger scratches have been observed on metallic femoral heads of explanted hip prostheses, with the larger scratches believed to be a major contributor to increased wear of the polyethylene acetabular cups. Previous work in our group has shown that smaller scratches, with a mean lip height up to 0.35 microm, can be caused by bone cement and bone particles up to 500 microm in size. However, the larger scratches were not readily replicated with these particles. Therefore in this study experimental and theoretical models have been developed to investigate the damage caused by harder metallic and ceramic particles. Small 10 microm diameter spherical metallic particles were also found to produce small fine scratches on the metallic counterface. However larger diameter spherical metal particles greater than 100 microm in diameter, which were embedded in polyethylene pins, caused severe sharp scratching of the metallic counterface with scratch lips greater than 0.5 microm. This level of damage, which was comparable to the severe damage found in vivo, was also simulated by a three body finite element model. Thus the larger metal particles led to the type of damage which was predicted to increase wear dramatically. This technique for simulating severe in vivo third body damage using spherical metal particles was found to be reproducible and reliable and will be used in the future in hip simulator testing to replicate third body damage and wear.

Journal Article↗

The prediction of polyethylene wear rate and debris morphology produced by microscopic asperities on femoral heads.

Counterface damage in the form of scratches, caused by bone cement, bone or metallic particles, has been cited as a cause of increased wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. It is known that high levels of particulate wear debris lead to osteolysis. Surface damage was characterized in a series of explanted Charnley femoral heads. The heads had a mean scratch height of 1 microm with a mean aspect ratio (defined as height divided by half width) of 0.1. Wear discs were artificially scratched using these scratch geometries as a guide. In addition, the scratch geometries were incorporated into a finite element model of a stainless steel asperity repeatedly sliding over UHMWPE under conditions similar to those in an artificial hip joint. Wear tests showed a strong correlation between the average cross-sectional area of the scratch lip above the mean zero line and the measured wear factor. The finite element model predicted increases in the area of UHMWPE suffering plastic strain with increases in the cross-sectional area of the asperity above the mean line. Analysis of the wear debris showed the mode of the particle size was 0.01-0.5 microm for all cases. The morphology of the particles varied with aspect ratio of the asperity, with an increased percentage mass of submicrometer-sized debris with increased scratch lip aspect ratio. The finite element results predicted that the maximum surface strains would increase with increasing asperity aspect ratio. Examination of the worn UHMWPE pin surfaces showed an association between increased surface damage, probably due to high surface strains, and increased aspect ratio. The large areas of surface plastic strain predicted for asperities with high cross-sectional areas above the mean line offer an explanation for the positive correlation between wear rate and the average cross-sectional area of the scratch lip material. The higher surface strains predicted for the higher aspect ratios may explain the increased percentage mass of biologically active submicrometer-sized wear particles found for scratch lips with higher aspect ratios.

Journal Article↗

Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations.

Ultra-high molecular weight polyethylene (UHMWPE) wear debris induced osteolysis has a major role in the late aseptic loosening and ultimate failure of total hip replacements (THR). Clinically relevant in vitro simulations of wear are essential to predict the osteolytic potential of bearing surfaces in artificial hip joints. Newborn calf or bovine serum has been accepted as a boundary lubricant for such in vitro tests, but its biological stability has been questioned. This study compared the wear factors, number of wear particles and levels of microbial contamination produced in bovine serum and a gelatin-based lubricant. The wear factors produced by the two lubricants were not significantly different, however the wear debris morphology produced was substantially different. The bovine serum became contaminated with micro-organisms within 28 h, whereas the protein-based lubricant remained uncontaminated. The results showed that bovine serum was not a stable boundary lubricant. They also showed that although the wear factors for the two solutions were not significantly different, the protein-based lubricant was not a suitable alternative to bovine serum because the wear debris produced was not clinically relevant.

Animals↗

A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups.

This study validates a hip joint simulator configuration as compared with other machines and clinical wear rates using smooth metal and ceramic femoral heads and ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. Secondly the wear rate of UHMWPE cups is measured in the simulator with deliberately scratched cobalt-chrome heads to represent the type of mild and severe scratch damage found on retrieved heads. Finally, the scratching processes are described and the resulting scratches compared with those found in retrieved cobalt-chrome heads. For smooth cobalt-chrome and zirconia heads the wear rates were found to be statistically similar to other simulator machines and within the normal range found from clinical studies. An increased wear rate was found with cobalt-chrome heads scratched using either the diamond stylus or the bead cobalt-chrome but the greatest increase was with the diamond scratched heads which generated scratches of similar dimensions to those on retrieved heads. A greater than twofold increase in wear rate is reported for these heads when compared with smooth heads. This increased wear rate is, however, still within the limits of data from clinical wear studies.

Acetabulum↗

Comparison of the response of primary murine peritoneal macrophages and the U937 human histiocytic cell line to challenge with in vitro generated clinically relevant UHMWPE particles.

The response of primary murine macrophages and the U937 human histiocytic cell line to challenge with clinically relevant UHMWPE wear debris of known particle size and dose was evaluated. Particles with mean sizes of 0.24, 0.45, 1.71, 7.62 and 88 microm were co-cultured with cells for 24 hours prior to assessment of cell viability and production of the osteolytic mediators IL-1beta, IL-6, TNFalpha and, in supernatants from murine phagocytes, PGE2 and GM-CSF. All particle fractions were evaluated at particle volume (microm3) to cell number ratios of 10 : 1 and 100 : 1 (and, additionally, 0.1 : 1 and 1 : 1 for U937 cells). These ratios had previously been identified as the most stimulatory and clinically relevant. Although the results for the cell line were highly variable, stimulation with phagocytosable particles (range 0.1 to 15 microm) resulted in enhanced levels of cytokine secretion by both murine macrophages and U937 histiocytes. The most biologically active particles were sub-micrometre in size. However, U937 cells responded to wear debris at much lower particle volume to cell number ratios (>0.1 microm3 per cell) than the murine cells (> 10 microm3 per cell). No GM-CSF was produced by particle or LPS stimulated murine macrophages. Similarly, U937 histiocytes failed to secrete any IL-1beta. Neither macrophage population responded to stimulation with the largest (88 microm) particles. These results confirm earlier findings and suggest that the size of UHMWPE wear particles is a critical factor in macrophage activation. Moreover, primary murine macrophages have been demonstrated to be a suitable model for studying cell-particle interactions in vitro.

Animals↗

A study of the wear resistance of three types of clinically applied UHMWPE for total replacement hip prostheses.

Ultra high molecular weight polyethylene (UHMWPE) is routinely used as one half of a bearing couple in clinical orthopaedic applications. This material is generally one of two grades, compression moulded GUR 1120, with a molecular weight of 4.4x 10(6) g mol(-1), or ram extruded GUR 4150HP with a molecular weight of 7.3x10(6) g mol(-1) although other grades are used as well. This study examines the effect of molecular weight and processing method by comparing the wear resistance of these two materials together with a non-standard extruded form of GUR 1120. Wear studies have been conducted against counterface surfaces which represent new and scratch-damaged femoral heads with bovine serum lubricant in a uniaxial reciprocating test configuration. No difference in the wear resistance was found between any material when tested against smooth cobalt chrome counterfaces. On rough cobalt chrome counterfaces, although no statistically significant difference (P>0.05) was found between the extruded and compression moulded GUR 1120, the extruded GUR 4150HP had a consistently better wear resistance. These results are discussed with reference to previous wear studies as well as the physical and mechanical properties of these materials.

Animals↗

Revision hip surgery in the elderly: is it worthwhile?

We prospectively analyzed the outcome in 103 consecutive patients undergoing revision hip replacement, dividing the patients into 2 groups according to their age at the time of surgery. There were 45 patients aged 75 years or older and 58 patients aged younger than 75 years. The results of revision hip replacement in terms of pain relief, functional improvement, and patient satisfaction did not differ between the 2 groups. There was a significantly higher death rate among the elderly patients (13.3% versus 1.7%; P = .0202) and a significantly higher rate of dislocation (20% versus 1.7%; P = .0019). We conclude that revision hip replacement is an effective operation in the elderly, but that patient and surgeon must be aware of the risks that such surgery entails.

Adult↗

Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements.

The biological reactions to polyethylene wear debris have been shown to result in osteolysis and loosening of total hip arthroplasties. This has led to renewed interest in the use of metal on metal bearings in hip prostheses. This study employed uniaxial and biaxial multistation pin on plate reciprocators to assess how the carbon content of the cobalt chrome alloy and the types of motion affected the wear performance of the bearing surfaces and the morphology of the wear debris generated. The low carbon specimens demonstrated higher wear factors than both the mixed carbon pairings and the high carbon pairings. The biaxial motion decreased the wear rates of all specimens. Plate wear was significantly reduced by the biaxial motion, compared to pin wear. The metal wear particles isolated were an order of magnitude smaller than polyethylene particles, at 60-90 nm, and consequently, 100-fold more particles were produced per unit volume of wear compared to polyethylene. The low carbon specimens produced significantly larger particles than the other material combinations, although it is thought unlikely that the difference would be biologically significant in vivo. The volumetric wear rates were affected by the carbon content of the cobalt chrome alloy, the material combination used and type of motion applied. However, particle morphology was not affected by the carbon content of the alloy or the type of motion applied.

Journal Article↗

Effects of in-season (5 weeks) creatine and pyruvate supplementation on anaerobic performance and body composition in American football players.

The purpose of this investigation was to study the efficacy of two dietary supplements on measures of body mass, body composition, and performance in 42 American football players. Group CM (n = 9) received creatine monohydrate, Group P (n = 11) received calcium pyruvate, Group COM (n = 11) received a combination of calcium pyruvate (60%) and creatine (40%), and Group PL received a placebo. Tests were performed before (T1) and after (T2) the 50 week supplementation period, during which the subjects continued their normal training schedules. Compared to P and PL, CM and COM showed significantly greater increases for body mass, lean body mass, 1 repetition maximum (RM) bench press, combined 1 RM squat and bench press, and static vertical jump (SVJ) power output. Peak rate of force development for SVJ was significantly greater for CM compared to P and PL. Creatine and the combination supplement enhanced training adaptations associated with body mass/composition, maximum strength, and SVJ; however, pyruvate supplementation alone was ineffective.

Adolescent↗

The influence of lubricant on the morphology of ultra-high molecular weight polyethylene wear debris generated in laboratory tests.

Since the implication of polyethylene wear debris as a major cause of osteolysis in total joint replacements, there has been much interest in polyethylene wear studies and in cell culture studies using ultra-high molecular weight polyethylene (UHMWPE) wear debris. Studies have shown that particles in the 0.1-10 microns size range are particularly important in causing adverse cellular reactions resulting in osteolysis. The morphology, the mass and size distributions, and the number of wear particles produced at the joint surfaces are influenced by the tribological conditions at the joint. Laboratory wear tests are used to investigate the wear properties of prosthetic joint materials and different research groups have used different lubricants in these tests. This paper shows that the volumetric wear and morphology of UHMWPE particles generated in vitro are influenced by the type of lubricant used. This study compared, quantitatively, UHMWPE wear debris generated in deionized water to debris that was generated in a system lubricated by bovine serum which was diluted to 25 per cent. The wear factors of UHMWPE in water and serum lubricants were significantly different (p < 0.05). UHMWPE wore 14 times more in water than in serum. Quantitative analysis of the wear particles showed that the debris that was generated in serum was morphologically different from debris that was produced in a water-lubricated system. Furthermore, the particles produced in serum showed a closer similarity to those found in retrieved acetabular tissues.

Blood↗

A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates.

In some designs of hip joint simulator the cost of building a highly complex machine has been offset with the requirement for a large number of test stations. The application of the wear results generated by these machines depends on their ability to reproduce physiological wear rates and processes. In this study a hip joint simulator has been shown to reproduce physiological wear using only one load vector and two degrees of motion with simplified input cycles. The actual path of points on the femoral head relative to the acetabular cup were calculated and compared for physiological and simplified input cycles. The in vitro wear rates were found to be highly dependent on the shape of these paths and similarities could be drawn between the shape of the physiological paths and the simplified elliptical paths.

Analysis of Variance↗

A comparison of the wear and debris generation of GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) ultra high molecular weight polyethylene.

The wear debris generated from UHMWPE (ultra high molecular weight polyethylene) has been recognised as one of the major causes of failure in THR (total hip replacement). GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) which are currently the most frequently used materials in THR were studied in pin-on-plate wear test. The wear particles generated from this test were observed by scanning electron micrograph and analysed by image analysis. The results from this study showed that GUR 4150HP had superior wear resistance than GUR 1120 under relatively high wear factor conditions. These results also highlighted the importance of multidirectional motion and its effect on the wear rates of UHMWPE. The multidirectional motion tended to show a higher wear factor than previous studies using unidirectional motion conducted under otherwise similar conditions. The wear debris analysis conducted with the wear particles collected from unidirectional (relatively rough) pin-on-plate wear tests (GUR 1120 and GUR 4150HP) showed that the greatest number of particles had a size range of 0.1-0.5 micron followed by 0.5-1.0 micron, 1.0-5.0 microns and 5.0-10.0 microns, in both GUR 1120 and GUR 4150HP. However, comparing the masses of the wear particles, the bigger size range of greater than 10 microns, had the highest percent mass followed by 1.0-5.0 microns, 0.5-1.0 micron, 0.1-0.5 micron and 5.0-10.0 microns.

Biocompatible Materials↗

Mapping variables.

This paper describes Mapping Variables, the principal technique for planning and constructing a test or rating instrument. A variable map is also useful for interpreting results. Modest reference is made to the history of mapping leading to its importance in psychometrics. Several maps are given to show the importance and value of mapping a variable by person and item data. The need for a critical appraisal of maps is also stressed.

Maps as Topic↗

An experimental model of tibial counterface polyethylene wear in mobile bearing knees: the influence of design and kinematics.

Current designs of mobile bearing knees have different kinematics at the tibial counterface articulation; unidirectional represented by linear tracks and rotating platform designs, and multidirectional represented by reduced constraint designs with motion of the tibial surface in A-P and M-L directions simultaneously. One fifth scale experimental models of the tibial counterface articulation have been developed with mean contact stresses of 0.6 MPa. The unidirectional model had a linear reciprocating motion with a 10 mm stroke, the multidirectional model had a reciprocating motion with a 10 mm stroke and simultaneous rotation of +/- 7.5 degrees. Six specimens of GUR415 polyethylene were tested for each model, sliding on polished cobalt chrome counterfaces with Ra < 0.01 micron in 25% bovine serum lubricant. The mean +/- STERR wear rates were: unidirectional 0.045 +/- 0.015 mm3/million cycles and multidirectional 0.44 +/- 0.15 mm3/million cycles. Applying the scaling factor of 5, the predicted wear rates in actual knee prostheses were: unidirectional 0.23 mm3/million cycles and multidirectional 2.2 mm3/million cycles. The order of magnitude increase in wear rate was statistically significant (p = 0.05).

Arthroplasty, Replacement, Knee↗

Effect of weight training exercise and treadmill exercise on post-exercise oxygen consumption.

Effect of weight training exercise and treadmill exercise on postexercise oxygen consumption. Med. Sci. Sports Exerc., Vol. 30, No. 4, pp. 518-522, 1998. To compare the effect of weight training (WT) and treadmill (TM) exercise on postexercise oxygen consumption (VO2), 15 males (mean +/- SD) age = 22.7 +/- 1.6 yr; height = 175.0 +/- 6.2 cm; mass = 82.0 +/- 14.3 kg) performed a 27-min bout of WT and a 27-min bout of TM exercise at matched rates of VO2. WT consisted of performing two circuits of eight exercises at 60% of each subject's one repetition maximum with a work/rest ratio of 45 s/60 s. Approximately 5 d after WT each subject walked or jogged on the TM at a pace that elicited an average VO2 matched with his mean value during WT. VO2 was measured continuously during exercise and the first 30 min into recovery and at 60 and 90 min into recovery. VO2 during WT (1.58 L.min-1) and TM exercise (1.55 L.min-1) were not significantly (P > 0.05) different; thus the two activities were matched for VO2. Total oxygen consumption during the first 30 min of recovery was significantly higher (P < 0.05) as a result of WT (19.0 L) compared with that during TM exercise (12.7 L). However, VO2 values at 60 (0.32 vs 0.29 L.min-1), and 90 min (0.33 vs 0.30 L.min-1) were not significantly different (P > 0.05) between WT and TM exercise, respectively. The results suggest that, during the first 30 min following exercise. WT elicits a greater elevated postexercise VO2 than TM exercise when the two activities are performed at matched VO2 and equal durations. Therefore, total energy expenditure as a consequence of WT will be underestimated if based on exercise VO2 only.