Search PubMed⌕ Search

Biomedical subjects

M H Stone

Publications and source records attributed to M H Stone.

At least 37 records · Page 2Linked to original sources

The effects of eliminating alcohol in a college stadium: the Folsom Field beer ban.

In fall 1996, the University of Colorado at Boulder instituted a ban on beer sales at football games. To evaluate the effects of the ban, the authors collected two types of data: first, they examined the effects of the ban on game-day security incidents; second, they looked at survey data from season ticket holders and students. They administered the surveys after the first two postban seasons to assess ticket holders' attitudes about the new policy. The incident data they found indicated dramatic decreases in arrests, assaults, ejections from the stadium, and student referrals to the judicial affairs office following the ban. Survey data also indicated moderately negative attitudes about the ban among students and some season ticket holders. However, all fans were likely to renew their tickets regardless of their attitudes toward the policy. The study illustrates what can be achieved when alcohol is eliminated from a setting that frequently fosters disorderly and aggressive behaviors.

Adolescent↗

Creatine supplementation and health variables: a retrospective study.

PURPOSE: Long-term safety of creatine supplementation has been questioned. This retrospective study was performed to examine markers related to health, the incidence of reported side effects and the perceived training benefits in athletes supplementing with creatine monohydrate. METHODS: Twenty-six athletes (18 M and 8 F, 24.7 +/- 9.2 y; 82.4 +/- 20.0 kg; 176.5 +/- 8.8 cm) from various sports were used as subjects. Blood was collected between 7:00 and 8:30 a.m. after a 12-h fast. Standard clinical examination was performed for CBC and 27 blood chemistries. Testosterone, cortisol, and growth hormone were analyzed using an ELISA. Subjects answered a questionnaire on dietary habits, creatine supplementation, medical history, training history, and perceived effects of supplementation. Body mass was measured using a medical scale, body composition was estimated using skinfolds, and resting heart rate and blood pressure were recorded. Subjects were grouped by supplementation length or no use: Gp1 (control) = no use (N = 7; 3 F, 4 M); Gp2 = 0.8-1.0 yr (N = 9; 2 F, 7 M); and Gp3 = 1(+) (N = 10; 3 F, 7 M). RESULTS: Creatine supplementation ranged from 0.8--4 yr. Mean loading dose for Gp2 and Gp3 was 13.7 +/- 10.0 and the maintenance dose was 9.7 +/- 5.7 g.d(-)1. Group differences were analyzed using one-way ANOVA. CONCLUSIONS: Expected gender differences were observed. Of the comparisons made among supplementation groups, only two differences for creatinine and total protein (P < 0.05) were noted. All group means fell within normal clinical ranges. There were no differences in the reported incidence of muscle injury, cramps, or other side effects. These data suggest that long-term creatine supplementation does not result in adverse health effects.

Adolescent↗

Influence of simulator kinematics on the wear of metal-on-metal hip prostheses.

There is now considerable interest in metal-on-metal bearings for hip prostheses. Extremely low wear rates (0.1 mm3/10(6) cycles) have been reported in some simulator studies, while in vivo studies, although still very low, have shown wear rates of the order of 1 mm3/10(6) cycles. The aim of this study was to compare wear rates of metal-on-metal bearings in two hip simulators with different kinematic inputs. In the simulator with three independent input motions which produced an open elliptical wear path with a low level of eccentricity, the wear rates were very low as recorded previously in other simulators. In the simulator with two input motions which produced an open elliptical wear path with greater eccentricity the wear rate was at least ten times higher and closer to clinical values. The motion and kinematic conditions in the contact are critical determinants of wear in metal-on-metal bearings.

Biomechanical Phenomena↗

A novel method for the prediction of functional biological activity of polyethylene wear debris.

The comparative performance of artificial hip joints has been extensively investigated in vitro through measurements of wear volumes. In vivo a major cause of long-term failure is wear-debris-induced osteolysis. These adverse biological reactions are not simply dependent on wear volume, but are also controlled by the size and volumetric concentration of the debris. A novel model is presented which predicts functional biological activity; this is determined by integrating the product of the biological activity function and the volumetric concentration function with the wear volume over the whole particle size range. This model combines conventional wear volume measurements with particle analysis and the output from in vitro cell culture studies to provide a new indicator of osteolytic potential. The application of the model is demonstrated through comparison of the functional biological activity of wear debris from polyethylene acetabular cups articulating under three different conditions in a hip joint simulator.

Biocompatible Materials↗

The influence of phospholipid concentration in protein-containing lubricants on the wear of ultra-high molecular weight polyethylene in artificial hip joints.

There is considerable interest in the wear of polyethylene and the resulting wear-debris-induced osteolysis in artificial hip joints. Proteins play an important role as boundary lubricants in vivo in the pseudosynovial fluid, and these are reproduced in in vitro tests through the use of bovine serum. Little is known, however, about the effect of phospholipid concentrations within proteinaceous solutions on the wear of ultra-high molecular weight polyethylene (UHMWPE). The effects of protein-containing lubricants with 0.05, 0.5 and 5 per cent (w/v) phosphatidyl choline concentrations on the wear of ultra-high molecular weight polyethylene (UHMWPE) were compared with 25 per cent (v/v) bovine serum which had 0.01 per cent (w/v) lipid; the effects were compared in a hip joint simulator with smooth (n = 4) and scratched (n = 3) femoral heads. The control bovine serum lubricant produced UHWMPE wear of 55 and 115 mm3/10(6) cycles on the smooth and rough heads respectively. The increased phospholipid concentration significantly reduced the wear rate. At the higher concentration (5% w/v phosphatidyl choline) the average wear was reduced to less than 2 mm3/10(6) cycles. Even with the relatively low concentrations of 0.05% w/v phosphatidyl choline the wear was reduced by at least threefold compared with the bovine serum tests for both the smooth and rough femoral heads. There may be considerable differences in the phospholipid concentrations in patients' synovial fluid and this is highly likely to produce considerable variation in wear rates. In vitro, differences in the phospholipid concentration of lubricants may also cause variation in wear rates between different simulator tests.

Hip Prosthesis↗

Quantification of third body damage to the tibial counterface in mobile bearing knees.

Fourteen pairs of explanted low contact stress (LCS) tibial interface components: six rotating platform (RP), six meniscal (MN) and two anterior-posterior (AP) glide designs, have been analysed with particular attention paid to the condition of the tibial counterfaces. The average surface roughness, Ra, for the tibial trays ranged from 0.01 to 0.087 micron, significantly greater than the unworn control measurement of 0.008 micron. The scratch geometry analysis showed that the scratch peaks were found to be consistently of a lower aspect ratio than the scratch valleys and under 1 micron in height (average asperity height Rp = 0.52 micron, aspect ratio delta p = 0.01, average asperity depth Rv = 1.10 microns, delta v = 0.05). The largest scratches were 3-4 microns in both Rp and Rv. In vitro tests have shown that ultra-high molecular weight polyethylene (UHMWPE) wear increases in the presence of counterface scratches perpendicular to the direction of motion. In these explants, the unidirectional motion produced scratches parallel to the direction of sliding which is predicted to produce a smaller increase in UHMWPE wear. Other designs in mobile bearing knees have less constrained motion at the tibial counterface and this has been shown to accelerate wear; it may also lead to a further increase in wear in the presence of third body scratches. It may be possible in future knee designs to reduce this type of wear damage by introducing alternative materials or coatings which are more resistant to scratching and surface roughening.

Aged↗

A novel three-dimensional tissue equivalent model to study the combined effects of cyclic mechanical strain and wear particles on the osteolytic potential of primary human macrophages in vitro.

The effects of cyclic mechanical strain and challenge with physiologically relevant doses of submicrometre-size polyethylene (PE) particles on the osteolytic potential of primary human mononuclear phagocytes were investigated. Cells were seeded into a three-dimensional tissue matrix and co-cultured with particles (mean size 0.21 microm) at particle volume to cell number ratios of 7.5, 15, 30 and 100 microm3/cell. Matrices were then either cultured statically or subjected to 20 per cent cyclic compressional strain in the 'ComCell' for 16 h prior to the assessment of cell viability and quantification of the pro-inflammatory cytokine tumour necrosis factor alpha (TNFalpha). The MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazdium bromide) assay was shown to be too insensitive to detect changes in cell viability. However, when quantified by the adenosine triphosphate (ATP) assay, cell viability was demonstrated to be reduced following exposure to cyclic strain. Macrophages cultured in the static three-dimensional tissue equivalent model produced very high levels of TNFalpha in response to submicrometre PE particles at a ratio of 100 microm3/cell. Cyclic strain in the absence of particles gave only a small increase in TNFa production. However, the combined effects of strain and particle stimulation at a ratio of 30 microm3/cell resulted in the secretion of significantly more TNFalpha than was produced by macrophages subjected to strain alone, or the cells-only control. This synergy between cyclic strain and PE particle stimulation was only evident when the volume of particles was reduced below the volume that maximally stimulated cells. These results suggest that while cyclic strain may not be the primary factor responsible for macrophage activation and periprosthetic osteolysis, at low particle load, it may contribute significantly to the osteolytic potential of macrophages in vitro or in vivo.

Coculture Techniques↗

A retrieval study of capital hip prostheses with titanium alloy femoral stems.

We have examined 26 retrieved, failed titanium-alloy femoral stems. The clinical details, radiological appearances and the histology of the surrounding soft tissues in each patient were also investigated. The stems were predominantly of the flanged design and had a characteristic pattern of wear. A review of the radiographs showed a series of changes, progressive with time. The first was lateral debonding with subsidence of the stem. This was followed by calcar resorption and fragmentation or fracture of the cement. Finally, osteolysis was seen, starting with a radiolucency at the cement-bone interface and progressing to endosteal cavitation. Three histological appearances were noted: granulomatous, necrobiotic and necrotic. We suggest that an unknown factor, possibly related to the design of the stem, caused it to move early. After this, micromovement at the cement-stem interface led to the generation of particulate debris and fracture of the cement. A soft-tissue reaction to the debris resulted in osteolysis and failure of fixation of the prostheses.

Aged↗

Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.

The wear debris generated from ultra high molecular weight polyethylene (UHMWPE) have been recognised as one of the major causes of failure in total hip replacements (THR). It is essential to reduce the wear debris generated from UHMWPE acetabular cups in order to minimise this problem. Debris in the submicron size range is believed to have greater osteolytic potential. It is now known that crosslinked UHMWPE acetabular cups have reduced volumetric wear rates but little is known about the influence of crosslinking on the size and morphology of the wear debris. In this study, the wear of grade GUR 1020 crosslinked (vacuum gamma irradiated), GUR 1120 crosslinked (acetylene enhanced irradiated) and non cross linked (ethylene oxide sterilised) GUR 1020 UHMWPE was compared in multidirectional pin-on-plate wear tests under three different counterface conditions (smooth, isotropically rough and scratched counterfaces). Multidirectional motion was chosen because this motion was closer to the relative motion in the natural hip. From this study, better wear resistance of crosslinked UHMWPE compared with non-crosslinked UHMWPE was demonstrated for the smooth counterface conditions. However, in the rough and scratched counterface conditions, the vacuum gamma irradiated crosslinked material produced significantly higher wear rates than the non-crosslinked material. The analysis of the wear debris showed that the majority of the volume of the acetylene enhanced crosslinked UHMWPE wear debris was in the most biologically active size range (0.1 to 0.5 microm). In contrast, the non-crosslinked material and the vacuum gamma irradiated crosslinked material had a greater proportion of the volume of the debris in the larger size ranges which are less biologically active. This has important implications for its osteolytic potential.

Acetylene↗

Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces.

A multidirectional pin-on-plate reciprocating machine was used to compare the wear performance of UHMWPE sliding against cast cobalt chrome (CoCr) plates that were either untreated or coated with Amorphous Diamond Like Carbon (ADLC). The test conditions were based on a 1/5 scale model representative of in vivo motion at the tibial counterfaces of unconstrained mobile bearing knees. The average +/- STERR wear rates were 13.78+/-1.06 mm3/Mcycles for the ADLC counterfaces and 0.504+/-0.12 mm3/Mcycles for the control CoCr counterfaces. All of the pins run on the ADLC counterfaces exhibited the same patterns of blistering along the central axis, and severe abrasion elsewhere to the extent that all of the original machining marks were removed after just one week of testing. The average value of friction coefficient was 0.24 for the ADLC counterfaces and 0.073 for the control CoCr counterfaces. The factor of 3.5 increase was statistically significant at p < 0.05. In the tribological evaluation of ADLC coatings for tibial trays in mobile bearing knees, this study shows that this specific Physical Vapour Deposition (PVD) ADLC showed significantly poorer frictional and wear performance than uncoated surfaces which was sufficient to negate any potential benefits of improved resistance to third body damage.

Biocompatible Materials↗

Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator.

Osteolysis and loosening of artificial joints caused by UHMWPE wear debris has prompted renewed interest in metal-on-metal (MOM) hip prostheses. This study investigated the wear and wear debris morphology generated by MOM prostheses in a physiological anatomical hip simulator for different carbon content cobalt chrome alloys. The low carbon pairings demonstrated significantly higher "bedding in" and steady state wear rates than the mixed and high carbon pairings. The in vitro wear rates reported here were up to one or two orders of magnitude lower than the clinical wear rates for first-generation MOM hip prostheses. Two methods for characterising the metal wear debris were developed, involving digestion, scanning electron microscopy and transmission electron microscopy. The metal wear particles characterised by the two methods were similar in size, 25-36 nm, and comparable to particles isolated from periprosthetic tissues from first and second-generation MOM hip prostheses. Due to the small size of the metal particles, the number of particles generated per year for MOM prostheses in vitro was estimated to be up to 100 times higher than the number of polyethylene particles generated per year in vivo. The volumetric wear rates were affected by the carbon content of the cobalt chrome alloy and the material combinations used. However, particle size and morphology was not affected by method of particle characterisation, the carbon content of the alloy or material combination.

Biomechanical Phenomena↗

Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles.

Polyethylene wear debris generated at the bearing surfaces of total artificial hip joints is thought to play an important role in the periprosthetic osteolysis and ultimately the aseptic loosening of these prostheses. The macrophage is believed to be central to this process by releasing various cytokines and other mediators of osteolysis upon phagocytosis of the polyethylene wear debris. This study evaluated the in vitro bone resorption response of C3H murine peritoneal macrophages to clinically relevant GUR 1120 polyethylene particles. Macrophages were co-cultured in vitro with GUR 1120 particles with a mean size of 0.24, 0.45, 1.71, and 7.62, and GUR 1120 polyethylene resin with a mean size of 88 microm at various particle volume (microm)(3): macrophage ratios (0.1:1; 1:1; 10:1; and 100:1). The conditioned supernatants were incubated with (45)calcium radio-labeled mouse calvariae, and bone resorption was measured as (45)calcium release. The results showed that the 0.24 microm particles stimulated the macrophages to generate bone resorbing activity at a ratio of 10(microm)(3) per macrophage. The 0.45 and 1.71 microm particles were active at a ratio of 100( microm)(3) per macrophage, and the 7.62 and 88 microm particles were inactive at all the doses tested. The co-culture supernatants were also assayed for TNF-alpha, IL-1beta, IL-6, and PGE(2). The results followed the same trend for particle size and volume dose to that observed for the bone resorbing activity. This study has demonstrated, for the first time, the importance of size and dose of clinically relevant polyethylene particles on the osteolytic response of macrophages in vitro.

Animals↗

Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose.

The response of primary human peripheral blood mononuclear phagocytes to challenge with clinically relevant ultra-high molecular weight polyethylene (UHMWPE) wear debris of known particle size and dose was evaluated. Particles with a mean size of 0.24, 0. 45, 1.7, 7.6, and 88 microm were cocultured with cells for 24 h before assessment of cell viability and production of the osteolytic cytokines interleukin (IL)-1 beta, IL-6, tumor necrosis factor-alpha, and granulocyte macrophage colony-stimulating factor, and prostaglandin E(2). All particle fractions were evaluated at particle volume (microm(3)) to cell number ratios of 10:1 and 100:1, which had been previously identified as being the most stimulatory and clinically relevant. None of the test fractions had an effect on cell viability. Whereas the heterogeneity of human individuals was clearly evident in the responses of the donors evaluated in this study (the response of donor 3 was between 5 and 20 times greater than the other donors), the most biologically active particles were found to be submicrometer in size. Stimulation with phagocytosable particles (0.24, 0.45, and 1.7 microm) resulted in enhanced levels of cytokine secretion. Macrophages stimulated with particles outside this size range produced considerably less cytokines at the volumes tested. These results confirm earlier findings and suggest that the size and volume of UHMWPE particles are critical factors in macrophage activation. Furthermore, they suggest that the heterogeneity of human individuals may be another important factor in determining implant life.

Biocompatible Materials↗

Comparison of the response of primary human peripheral blood mononuclear phagocytes from different donors to challenge with model polyethylene particles of known size and dose.

The response of primary human peripheral blood mononuclear phagocytes to challenge with polyethylene particles of known size and dose was evaluated. Particles with mean sizes of 0.21, 0.49, 4.3, 7.2, and 88 microm were co-cultured with cells for 24 h prior to the assessment of cell viability and production of the osteolytic mediators IL-1beta, IL-6, TNFalpha, GM-CSF and PGE2. All particle fractions were evaluated at particle volume (microm3) to cell number ratios of 10:1 and 100:1 which were previously identified as being the most biologically active and clinically relevant. The heterogeneity of human individuals was clearly evident both in the profile and the magnitude of the response of the donors evaluated in this study (the response of donor 5 being 2- to 15-fold lower than that of the other donors). Only the sub-micrometre particles stimulated significantly enhanced cytokine secretion at the ratios tested: mean particle sizes of 0.49 and 0.21 microm being the most biologically active. Macrophages stimulated with particles outside this size range produced considerably lower levels of mediator. These results compared favourably with the results of earlier studies, which demonstrated that particles within the phagocytosable size range (0.1-10 microm) were the most biologically active. These results, therefore, confirm earlier findings and suggest that the size and volume of polyethylene particles are critical factors in macrophage activation. Furthermore, they suggest that the heterogeneity of human individuals may be another important factor in determining implant life and could provide the basis for a valuable diagnostic tool to identify those patients most at risk of implant loosening.

Blood Donors↗

Production of TNF-alpha and bone resorbing activity by macrophages in response to different types of bone cement particles.

We have compared the capacity of clinically relevant wear debris from seven different cement types to activate macrophages to produce TNF-alpha, IL-1beta, IL-6 and bone resorbing activity in vitro. The bone cements were: CMW 1 original (PMMA only); CMW 1RO (1 microm BaSO4; 9.2%); CMW copolymer bone cement 1 (10 microm BaSO4; 10%); CMW copolymer bone cement 2 (1 microm BaSO4; 10%); Palacos R (10 microm ZrO2; 15.6%); CMW Calcium phosphate cement 20% (10 microm tri-calcium phosphate; 20%) and CMW calcium phosphate cement 30% (10 microm tri-calcium phosphate; 30%). Cement debris was produced aseptically using a simple configuration wear test. The majority of particles were in the size range 0.1-0.5 microm for each cement type. The cement particles were co-cultured with the U937 macrophage cell line at ratios of 10 and 100 microm3 particle volumes to macrophage cell numbers for 24 h. At the 10:1 ratio the particles had no effect on the cells. At the 100:1 ratio, the major cytokine produced was TNF-alpha and there were no statistical differences between the different types of cement debris. The bone resorption activity of the co-culture supernatants was significantly greater than the control (U937 cells without particles) for particles of CMW 1RO, CMW copolymer bone cement 1, CMW copolymer bone cement 2 and Palacos R (P < 0.05, ANOVA). However there were no statistical differences between the levels of bone resoprtion evoked by these four cement types. The CMW1 original and CMW calcium phosphate containing cements failed to induce the macrophages to elaborate bone resorption activity at the 100:1 ratio. These data suggest that the addition of radio-opaque additives to bone cement may increase the capacity of the debris to induce osteolysis.

Acrylic Resins↗

Clinical guidelines for psychotherapy for patients with borderline personality disorder.

In planning a course of psychotherapy for borderline patients, clinicians must take into account the heterogeneity of the clinical presentation in the borderline domain. Borderline personality disorder is usually accompanied, for example, by one or several "symptom disorders," such as an eating disorder, depression, posttraumatic stress disorder, premenstrual tension, dissociative disorder, or anxiety disorder--not to mention one or more other personality disorders. The nature of the "comorbidity" in each patient will determine which medications, if any, are applicable. The accompanying personality disorders will have an impact on amenability to psychotherapy. The main forms of therapy currently in use are supportive, cognitive-behavioral (including dialectical behavioral therapy) and psychodynamic (including transference-focused psychotherapy). Group therapy is often used adjunctively with any of these approaches. The main question is no longer, Which of these approaches is best, overall? but rather, Which approach is best for which type of borderline patient? Contemporary research is addressed to this latter question.

Adult↗

Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses.

Submicrometer- and micrometer-sized ultra-high molecular weight polyethylene (UHMWPE) wear particles have been associated with osteolysis and failure of total artificial joints. Previous studies have isolated predominantly submicrometer-sized particles at the expense of larger particles (>10 microm). This study aimed to isolate and characterize quantitatively all sizes of UHMWPE wear particles generated in 18 Charnley hip prostheses. In addition, to analyze the wear debris with respect to the total volumetric wear of the cup and damage to the femoral head. Particle size distributions ranged from 0.1 to ->1000 microm. A significant proportion (3-82%) of the mass of the wear debris isolated was>10 microm. The mode of the frequency distribution of the particles was in the range 0.1-0.5 microm for all patients. However, analysis of the mass of wear debris as a function of its size allowed differentiation of the wear debris from different patients. Femoral head damage was associated with high volumetric wear and increased numbers of biologically active submicrometer-sized particles.

Journal Article↗