Removal of beta 2-microglobulin by adsorption on dialysis membranes.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Goldman.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Balb/c neonates injected with semi-allogeneic (A/J x Balb/c) F1 hybrid spleen cells develop an autoimmune disease associated with an immune-complex glomerulonephritis. The successful induction and maintenance of B cell chimerism is required for the occurrence of autoimmunity. The percentage of chimeric mice displaying autoimmune features increases in parallel with the number of cells injected at birth. T cell depleted inocula although readily inducing B cell chimerism were found unable to induce hypergammaglobulinaemia, circulating immune complexes and glomerulonephritis. IgG1 is the most and IgG3 the least represented IgG isotype among the immunoglobulins deposited in the glomeruli. Immunoglobulins bearing donor (A/J) allotype are detected in the glomeruli of six out of 11 chimeric mice. Rheumatoid factor activity is significantly concentrated within the immunoglobulins eluted from the kidneys, whereas anti-DNA activity is not.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Cardiac involvement has been reported at autopsy in 20% of patients with sarcoidosis. Involvement of the pericardium with sarcoidosis is rare, with a reported rate of 3% or less at autopsy. We report a case of sarcoidosis with a pericardial effusion which responded dramatically to 30 mgs of prednisone a day with resolution of the effusion, weight gain, and normalization of his temperature curve. The diagnosis of sarcoidosis was established by the typical pathologic changes in biopsies of lymph nodes, liver and bone marrow. All other causes of granulomatous disease and pleural effusion were absent. Pericardial involvement is a rare complication of sarcoidosis and steroid therapy may be effective in treatment.
Many patients with diffuse malignant pleural mesothelioma have dyspnea or chest pain. Cardiac symptomatology is frequently difficult to differentiate from symptoms of pleuropulmonary disease. To better define the clinical characteristics of cardiac involvement in patients with mesothelioma, the electrocardiographic (EKG) and echocardiographic findings in 64 patients with biopsy-proven malignant pleural mesothelioma were reviewed. A total of 19/64 (30%) patients had autopsy studies available for review. The EKG was abnormal in 55 patients (89%). Over half (60%) had an arrhythmia, including sinus tachycardia (42%), premature atrial and ventricular contractions (13%), atrial fibrillation (3%), and atrial flutter (1%). Over one third (37%) had a conduction abnormality, including bundle branch block (13%), hemiblock (8.5%), and incomplete right bundle branch block (13%). Echocardiography revealed a total of 13 patients with pericardial effusions, two with pericardial thickening, and one with an anterior sonolucent space. Of 19 autopsies, cardiac invasion was found in 14 (74%), with more than half to the pericardium and more than one quarter to the myocardium. It is concluded that: clinical cardiac abnormalities occur in the great majority of patients with malignant pleural mesothelioma, pathologic cardiac invasion occurs in the great majority of patients with pleural mesothelioma, and the EKG and echocardiogram are helpful in differentiating cardiac involvement from progressive pulmonary disease in patients with pleural mesothelioma.
Patients and members of staff from a haemodialysis unit were tested for markers of infection with human T cell lymphotropic virus type III (HTLV-III), the virus associated with the acquired immune deficiency syndrome (AIDS). An enzyme linked immunosorbent assay showed eight of 100 patients to have antibodies to HTLV-III. In five of these patients past or present infection with HTLV-III was confirmed by Western blot analysis or detection of HTLV-III antigens in lymphocyte cultures, or both. Investigation of other risk factors for AIDS showed that the putative source of HTLV-III was unrelated to dialysis in two patients whereas blood transfusion was the most likely cause of contamination in the others. No member of staff gave a positive result in the enzyme linked immunosorbent assay. Nosocomial transmission of HTLV-III seems unlikely if precautions similar to those recommended for the control of hepatitis B infection are applied.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The area-length method is widely used in the determination of left ventricular volume. Although previous studies have reported that this technique overestimates true volume (TV), it is unknown whether this overestimation is the same at different volumes. In the present study, with the use of 10 postmortem human hearts, left ventricular volumes were determined by contrast x-ray biplane cine ventriculography (LVA), biplane radionuclide (LVR), and absolute-counts (LVC) technetium scans, and the results were correlated with TV. LVA correlated well with TV (r = 0.98). LVR correlated well with TV (r = 0.97), and LVR also correlated well with LVA (r = 0.96). Both area-length techniques (LVA and LVR) resulted in overestimation of TV with an upward shift of the regression line of 30.4ml +/- 3.8 (SEM) for LVA and 28.5 +/- 4.4 for LVR. The percentage of overestimation error was significantly greater at smaller left ventricular volumes (error = 33% at TV = 30ml and 10% at TV = 100ml, p less than 0.001). LVC correlated well with TV (r = 0.99), TVA, and LVR but underestimated TV. Thus left ventricular volumes can be reliably obtained from LVR and LVA by means of the area-length method and from LVC. When the area-length method is utilized, the percentage of error in the determination of left ventricular volume is proportional to 1/TV.
Explore the source record for details and available documents.
Electrocardiogram-gated magnetic resonance imaging (MRI) was used to evaluate 36 children, ages 2 to 17 years, with congenital heart disease. With the use of multiple imaging planes, including transverse, sagittal, coronal, and 60-degree left anterior oblique views, high contrast images with excellent spatial resolution were produced. In 34 of the 36 patients the anatomic detail provided by MRI was sufficient to make the cardiac diagnosis. Electrocardiogram-gated MRI is an important new imaging technique for use in children with cardiovascular disease.
Electrocardiographic-gated nuclear magnetic resonance imaging was used to evaluate 10 patients, aged 2.5 to 18 years, with coarctation of the aorta. Six patients had balloon dilation angioplasty, one had surgical repair and three are awaiting treatment. Imaging studies were performed before and after therapy in three patients. In all pretreatment studies, the sagittal and 60 degrees left anterior oblique imaging planes adequately revealed the anatomy of the coarctation. Post-treatment imaging studies demonstrated effective relief of the coarctation in all cases. In three of the six patients who had balloon angioplasty, there was a variable degree of dilation of the aorta at the site of the previous coarctation. Nuclear magnetic resonance imaging is an effective noninvasive imaging method for visualizing coarctation of the aorta and for follow-up after treatment.
The authors investigated the respiratory effects of diazepam in 24 healthy volunteers using a modified Read rebreathing circuit. Resting end-tidal CO2 (PETCO2) and the slopes of the ventilatory (VE/PETCO2) and occlusion pressure (P0.1/PETCO2) response to CO2 were measured just prior to and 5, 20, 40, and 60 min after diazepam, 0.1 mg/kg iv. The slope of VE/PETCO2 for all 24 subjects analyzed as a single group was never significantly depressed. The slope of P0.1/PETCO2 for all 24 subjects analyzed as a single group was significantly depressed only at 5 min after diazepam. The resting PETCO2, however, had small but statistically significant increases throughout the 1 h of study. Group or cluster analysis of the slope of P0.1/PETCO2 clearly divided subjects into one group of five subjects, whose P0.1/PETCO2 slope was significantly and consistently augmented for 1 h and a second group of 19 subjects whose P0.1/PETCO2 slope was always less than control for the entire hour. Diazepam may, through effects on pulmonary mechanics and/or the central nervous system, sometimes enhance respiratory responses to CO2 rebreathing. Failure to select for such group effects when studying drug effects by CO2 rebreathing may obscure the severity and duration of respiratory depression that occurs in the majority of individuals. Resting PETCO2 indicated consistent depression of resting minute ventilation by diazepam and may be a more appropriate or sensitive measure of mild or subtle drug-induced respiratory effects.
Transesophageal echocardiography (TEE) is a new monitoring technique that images the heart and provides information on regional wall motion and left ventricular filling. However, despite its potential for inaccuracy due to its retrocardiac position and angulation, TEE has not been validated by another imaging technique. Using direct on-heart echocardiography (OHE) as a standard, the authors evaluated the ability of TEE to measure accurately left ventricular end-diastolic area (EDa), end-systolic area (ESa), and ejection fraction area (EFa). Ten patients with coronary artery disease without evidence of valvular dysfunction undergoing myocardial revascularization were studied. A Diasonics 3.5 MHz two-dimensional TEE probe was introduced into each patient's esophagus and positioned to obtain a view equivalent to the parasternal short-axis projection. A similar view was obtained by OHE using a sterilely prepared 3 MHz ATL probe placed on either the pericardium or epicardium. In each patient, immediately prior to and after pericardiotomy, both transesophageal and on-heart short-axis views at the level of the papillary muscles were obtained. Using a dedicated Diasonics computer echoanalyzer, EDa and ESa from four consecutive cardiac cycles were outlined with a light pen and averaged. EFa was calculated by the formula EFa = (EDa - ESa)/EDa. Seventeen comparable transesophageal and on-heart echocardiograms were obtained. ESa by TEE correlated well with ESa by OHE (15.13 +/- 9.62 cm2 vs. 14.92 +/- 10.53 cm2; r = 0.94). Similar results were obtained for EDa (27.75 +/- 9.88 cm2 vs. 30.40 +/- 13.99 cm2; r = 0.88) and EFa (0.49 +/- 0.17 vs. 0.54 +/- 0.13; r = 0.92). filling and ejection.
In this study ventilation was evaluated in 12-mo-old male and female rats who had received large doses of aspartic acid neonatally. Rats of both sexes treated with aspartic acid were obese, stunted, and exhibited hypogonadism. Although metabolic rates of the aspartic acid-treated rats were not different compared with sex-matched controls, ventilatory patterns were different. Aspartic acid-treated females breathed with a smaller tidal volume (VT), higher frequency (f), and similar minute ventilation (VE) compared with control females. This pattern is commonly observed in many patients who are obese. The aspartic acid-treated females responded to hypercapnic and hypoxic challenges by increasing f more than VT. Tissue pocket gases (PCO2 and PO2) of aspartic acid-treated females were normal. In contrast, aspartic acid-treated males hypoventilated compared with control males. Tissue pocket gas values suggested that aspartic acid-treated males were hypoxemic and hypercapnic. Moreover, the response of aspartic acid-treated males to hypercapnia was parallel to but was less than that of control male rats. The ventilatory response of aspartic acid-treated male rats to hypoxia was blunted. This study has shown that neonatal administration of aspartic acid causes a decreased ventilation and blunted response to hypoxia in adult male but not female rats.
Personal experience with subclavian vein cannulations for hemodialysis are given, and the pertinent literature on the subject is reviewed. Two hundred subclavian dialysis catheters were placed in 148 patients who kept them in place for a total of 2,798 days. Immediate complications were two pneumothoraxes and two hemothoraxes due to subclavian artery puncture. Seventeen cases of bacteremia were related to subclavian catheter infections. In 1 case, a complication of sepsis was a vertebral osteomyelitis. Clinical evidences of subclavian vein thrombosis occurred in 5 cases. Life-threatening complications were met in 2 cases: 1 with pericardial tamponade due to right atrium perforation and 1 with mediastinal hematoma and right hemothorax due to superior vena cava perforation. Review of the literature indicates that pneumothoraxes and/or hemothoraxes occurred in 1.7% of the catheter insertions and that sepsis related to subclavian dialysis catheters occurred in 8.9% of the patients. As systematically investigated subclavian vein thrombosis involved at least 50% of the patients. Our 2 personal cases of life-threatening complications and 14 similar cases of the literature were analyzed: left subclavian catheters were associated with superior vena cava perforation with right hemothorax or mediastinal hematoma, while right subclavian catheters gave atrial perforation with pericardial tamponade. Death occurred in 3 of 16 cases, and emergency surgery was required in 5 of 16 cases. Taking into account all these complications, recommendations are made for the use of subclavian dialysis catheters.