Search PubMed⌕ Search

Biomedical subjects

M Goddard

Publications and source records attributed to M Goddard.

79 records · Page 5Linked to original sources

Microporous small diameter PVDF-TrFE vascular grafts fabricated by a spray phase inversion technique.

Microporous prostheses of 1.5 mm internal diameter were fabricated with a polyvinylidene fluoride-trifluoroethylene (PVDF-TrFE)n co-polymer by the spray phase inversion technique. Some of the grafts were made piezoelectric by poling under a high electrical field. Overall, 24 poled grafts (P) and 24 unpoled grafts (UP) (15-22 mm in length) were implanted in the infrarenal aorta of 48 adult rats. Patency rates in P were 100% (8/8) at 2 days, 100% (8/8) at 2 weeks, 75% (6/8) at 6 months, and 92% total (22 of 24). Patency rates in UP were 100% (8/8) at 2 days, 63% (5/8) at 2 weeks, 100% (8/8) at 6 months, and 88% total (21 of 24). Thus there was no significant difference in patency between the two types of grafts. Both showed similar macroscopic and microscopic findings. At 2 days, fibrin deposition was somewhat heavier on the poled grafts, but no difference in surface platelet deposition could be detected. Endothelialization was observed from both anastomoses at 2 weeks and was almost complete at 6 months. The excellent biocompatibility of PVDF-TrFE and the microporous structure of the grafts were probably the dominant factors in success with these grafts. Although piezoelectric activity in excised cleaned poled prostheses remained significantly higher than that in the control UP, the charges developed may have been too small to exert a biologic effect, either because of insufficient dipole orientation or inadequate mechanical deformation.

Animals↗

Penetrating micropores increase patency and achieve extensive endothelialization in small diameter polymer skin coated vascular grafts.

This article points to the importance of penetrating micropores through the graft wall to minimize thrombosis and to enhance endothelialization in small diameter polymer skin coated vascular grafts. Four types of spongy polyurethane-polydimethylsiloxane vascular grafts (PUG) fabricated by a spray, phase-inversion technique, 1.5 mm inner diameter, 1.5-1.9 cm in length, were implanted end-to-end in the infrarenal aorta of 26 adult rats. Some had a continuous inner skin and a hydraulic permeability (HP) of 0 ml/min/cm2/ 120 mmHg (PUG-S-O). Some had an inner skin with varying amounts of isolated penetrating micropores and a mean hydraulic permeability of 11 (PUG-S-11), 37 (PUG-S-37), or 58 ml/min/cm2/120 mmHg (PUG-S-58). Twelve PUG-S-O, 6 PUG-S-11, 4 PUG-S-11, and 4 PUG-S-58 were evaluated between 2 hr and 3 months after implantation. All PUG-S-O occluded soon after implantation. The PUG that had a HP of more than 11 ml/min/cm2 showed acceptable patency. However, endothelialization was limited to anastomoses in patent PUG-S-11. In contrast, the patent PUG-S-37 and PUG-S-58 were largely endothelialized. In all patent grafts at 3 months, numerous host cells had migrated, and newly formed capillaries were seen in the voids of the graft wall, which appeared moderately to highly cellular. In conclusion, it appears that penetrating micropores through the graft wall increase patency and that a highly porous structure is needed to achieve extensive endothelialization in small diameter polymer skin coated vascular grafts.

Animals↗

Preservation, reperfusion, and rejection in transgenic xenograft organs.

The success of transplantation has resulted in increasing demand, despite a continuing fall, in donor organ supply. This widening gap encourages the argument for animals to act as a reservoir for donor organs (xenografts). Despite genetic manipulation, transgenic xenograft organs are at risk of vascular rejection in man (delayed xenograft rejection), a process in part involving endothelial cell activation. It appears that ischemia-reperfusion injury also involves endothelial cell activation. Evidence already exists to support the suggestion that ischemia-reperfusion injury may promote delayed xenograft rejection. The mechanisms of both these processes are briefly described and a case is made for optimum organ preservation of transgenic xenograft donor organs before clinical work is proposed.

Animals↗

In vivo evaluation of porous versus skinned polyurethane-polydimethylsiloxane small diameter vascular grafts.

Two types of spongy polyurethane-polydimethylsiloxane (PU-PDMS) vascular grafts (1.5 mm ID, 450 microns wall thickness) were fabricated with either a skinned (SG) or a porous (PG) luminal surface and an open mesh filamentous external surface by a spraying, phase-inversion technique. Tubular membranes, 15-20 mm in length, were all implanted by the same surgeon as infrarenal aorta replacements in male Sprague-Dawley rats weighing 250-350 g (SG: n = 12, PG: n = 23). The patency rates at 2 weeks and 3 months were 0% (0/7) and 0% (0/1) for SG, 72% (8/11) and 8% (1/12) for PG. Because the wall structure of these grafts was relatively compact and did not provide enough communicating voids, another series of 15 highly porous luminal surface grafts was fabricated with a higher void to material ratio. These grafts (HPG) exhibited a 73% patency at 3 months, with a fully endothelialized surface. The authors conclude that a very open luminal surface structure, and a high wall porosity, are significant factors of graft patency in small diameter vascular prostheses made of a porous material.

Animals↗

Taken to task.

Explore the source record for details and available documents.

Efficiency↗