Implantable left ventricular assist devices provide an excellent outpatient bridge to transplantation and recovery.

OBJECTIVES: Our recent experience with outpatient left ventricular assist device (LVAD) support is presented to demonstrate the possibilities and limitations of long-term outpatient mechanical circulatory assistance. BACKGROUND: The experience with inpatient LVAD support as a bridge to transplantation has proved the efficacy of such therapy in improving circulatory hemodynamic status, restoring normal end-organ function and facilitating patient rehabilitation. With miniaturization of the power supplies and controllers, such mechanical circulatory support can now be accomplished in an outpatient setting. METHODS: Between March 1993 and February 1997, 32 patients (26 male, 6 female, mean [+/-SEM] age 49 +/- 15 years) underwent implantation of the ThermoCardiosystems (TCI) Heartmate vented electric (VE) LVAD. The VE LVAD is powered by batteries worn on shoulder holsters and is operated by a belt-mounted system controller, allowing unrestricted patient ambulation and hospital discharge. RESULTS: Mean duration of support was 122 +/- 26 days (range 3 to 605), with a survival rate to transplantation or explantation of 78%. Nineteen patients were discharged from the hospital on mean postoperative day 41 +/- 4 (range 17 to 68), for an outpatient support time of 108 +/- 30 days (range 2 to 466). Four patients underwent early transplantation and could not participate in the discharge program, and three patients currently await discharge. The complication rate was not statistically different from that encountered in our previous 52 patients with a pneumatic LVAD. CONCLUSIONS: Outpatient LVAD support is safe and provides improved quality of life for patients awaiting transplantation. Wearable and totally implantable LVADs should be studied as permanent treatment options for patients who are not candidates for heart transplantation.

Ambulatory Care↗

Implantable left ventricular assist devices: an evolving long-term cardiac replacement therapy.

OBJECTIVE: The authors' 8-year experience with both inpatient and outpatient left ventricular assist device (LVAD) support is presented to show the possibilities and limitations of long-term outpatient mechanical circulatory assistance. SUMMARY BACKGROUND DATA: The limitation of suitable cardiac donors has led to the use of LVADs as a temporizing measure for patients awaiting cardiac transplantation. The success of such devices in the short and medium term as a bridge to transplantation has led to their evaluation as a long-term destination therapy for end-stage heart disease. METHODS: Between August 1990 and February 1997, 85 patients with end-stage heart disease underwent insertion of implantable LVADs. Fifty-two patients underwent pneumatic device insertion and 32 patients received a vented electric device. RESULTS: Patients were supported for a mean of 109+/-13 days for an overall survival to transplant (54) or explant (3) of 73%. Nineteen patients were discharged from the hospital on a mean of postoperative day 41+/-4 (range, 17-68) for an outpatient support time of 108+/-30 days (range, 2-466). Of 12 patients supported after postcardiotomy cardiogenic shock, 10 (82%) survived to hospital discharge. Perioperative right ventricular failure was treated in most patients with inotropic agents and inhaled nitric oxide with only six patients requiring right ventricular assist device support. Thromboembolic rate was low (0.016 events/patient-month) despite minimal or no anticoagulation in all cases. CONCLUSIONS: Left ventricular assist device support has evolved to become an outpatient therapy with excellent survival rates and an acceptable morbidity. Accordingly, wearable LVADs should be studied as permanent treatment options for patients who are not transplant candidates.

Ambulatory Care↗

Treatment of endstage heart disease with mechanical circulatory assistance.

A great number of patients suffer and die from the sequelae of acute and chronic heart failure each year. Although advances in medical and surgical therapy have benefited many of these patients, the majority suffer from disease refractory to any definitive therapy. For these patients, cardiac transplantation is the only remaining hope. Unfortunately, because of the increasing demand for donor organs in the face of a fixed and limited supply, this option is only available to a small percentage of these patients. Even in patients accepted for transplantation, a significant waiting list mortality has been observed. A variety of ventricular assist devices (VAD) have been developed since the first successful case of mechanical cardiac assistance over 30 years ago. These devices differ in basic mechanical function, method of insertion, and degree of implantability, and thus have different indications and potential applications. While the intra-aortic balloon pump and centrifugal pumps are effective short-term support modalities, extracorporeal and implantable pulsatile devices have been used successfully for long-term support of patients with reversible and non-reversible cardiac failure. These pumps have most commonly been utilized as bridges to transplantation, but increasing clinical experience has supported the notion of long-term mechanical assistance as a definitive therapy for endstage heart disease. While complications, particularly infection and thromboembolism, pose significant challenges and long-term device reliability remains to be fully determined, available implantable devices seem capable of providing effective long-term support. As data is obtained from currently ongoing trials comparing VAD support to medical therapy for endstage heart failure, ethical and economic issues will assume increasing importance.

Assisted Circulation↗

Is aprotinin indicated for reoperative valvular surgery?

BACKGROUND AND AIMS OF THE STUDY: While the hemostatic effect of aprotinin for patients undergoing reoperative coronary bypass is well established, it remains unclear whether these effects extend to patients undergoing reoperative valvular surgery. METHODS: We examined our experience with 85 consecutive patients undergoing isolated reoperative valvular surgery with and without use of perioperative aprotinin in order to investigate differences in perioperative blood use, blood loss, bleeding complications, mortality and incidence of myocardial injury. RESULTS: Aprotinin recipients benefited from a significant reduction in bleeding complications, and a decrease in perioperative and in-hospital mortalities as compared with untreated patients. Anaphylactic reactions and clinically significant thromboembolic events were not observed. There was no difference in the incidence of renal dysfunction or myocardial injury among aprotinin-treated and untreated groups. CONCLUSIONS: Our results indicate that aprotinin therapy can be safely administered to patients undergoing reoperative valvular surgery. No increased incidence of anaphylactic reactions, renal dysfunction or perioperative myocardial injury was noted. The observed reductions in bleeding complications and perioperative and in-hospital mortality strongly warrant the evaluation of aprotinin for reoperative valvular surgery in a prospective fashion.

Adolescent↗

Self-hypnosis reduces anxiety following coronary artery bypass surgery. A prospective, randomized trial.

OBJECTIVE: The role of complementary medicine techniques has generated increasing interest in today's society. The purpose of our study was to evaluate the effects of one technique, self-hypnosis, and its role in coronary artery bypass surgery. We hypotesize that self-hypnosis relaxation techniques will have a positive effect on the patient's mental and physical condition following coronary artery bypass surgery. EXPERIMENTAL DESIGN: A prospective, randomized trial was conducted. Patients were followed beginning one day prior to surgery until the time of discharge from the hospital. SETTING: The study was conducted at Columbia Presbyterian Medical Center, a large tertiary care teaching institution. PATIENTS: All patients undergoing first-time elective coronary artery bypass surgery were eligible. A total of 32 patients were randomized into two groups. INTERVENTIONS: The study group was taught self-hypnosis relaxation techniques preoperatively, with no therapy in the control group. MEASURES: Outcome variables studied included anesthetic requirements, operative parameters, postoperative pain medication requirements, quality of life, hospital stay, major morbidity and mortality. RESULTS: Patients who were taught self-hypnosis relaxation techniques were significantly more relaxed postoperatively compared to the control group (p=0.032). Pain medication requirements were also significantly less in patients practising the self-hypnosis relaxation techniques that those who were noncompliant (p=0.046). No differences were noted in intraoperative parameters, morbidity or mortality. CONCLUSION: This study demonstrates the beneficial effects self-hypnosis relaxation techniques on patients undergoing coronary artery bypass surgery. It also provides a framework to study complementary techniques and the limitations encountered.

Aged↗

Delayed reversal of impaired metabolic vasodilation in patients with end-stage heart failure during long-term circulatory support with a left ventricular assist device.

BACKGROUND: Whether increased cardiac output during chronic circulatory support with a left ventricular assist device (LVAD) is associated with improved metabolic vasodilation in the peripheral circulation of patients with congestive heart failure is unknown. METHODS: Forearm blood flow, determined by venous occlusion plethysmography, mean arterial pressure, and cardiac output were measured at rest and after 5 minutes of arterial occlusion (a maximal metabolic vasodilatory stimulus) in 14 patients with severe heart failure before LVAD implantation, and in the early (<4 weeks) and late (8 to 12 weeks) postoperative recovery phases after LVAD implantation. Nine normal subjects served as controls. Vascular conductance was calculated as the ratio of forearm blood flow and mean arterial pressure. RESULTS: Mean arterial pressure and cardiac output increased to normal values in the early and late recovery phases after LVAD implantation. Resting forearm blood flow and vascular conductance were similar to normal subjects in the early and late recovery phases after LVAD implantation. Peak forearm blood flow and vascular conductance were significantly less than control subjects in the early preoperative recovery phase (p < 0.05) but were similar to control subjects in the late postoperative recovery phase after LVAD implantation. CONCLUSIONS: In spite of early normalization of cardiac output, mean arterial pressure, and resting forearm blood flow during chronic circulatory support with the LVAD, peak forearm blood flow, and peak vascular conductance did not increase to values similar to those observed in normal subjects until the late postoperative recovery period. The delayed effect of the LVAD on metabolic vasodilation may be related to flow-dependent changes in the peripheral vasculature of patients with heart failure.

Adolescent↗

The influence of infection on survival and successful transplantation in patients with left ventricular assist devices.

BACKGROUND: Mechanical cardiac assistance has recently emerged as a tenable option in the treatment of end-stage heart failure. In spite of recent technical improvements that have reduced the incidence of life-threatening complications, the reported frequency of infections in these patients has remained high. METHODS: Over a 5-year period, 60 patients underwent insertion of a left ventricular assist device (LVAD) at our institution. Detailed medical records were kept prospectively for all patients, and a variety of endpoints were analyzed, including the incidence, nature, and sequelae of infections before and after LVAD implantation and after transplantation. RESULTS: Twenty-nine of 60 patients (48%) undergoing LVAD insertion subsequently had development of infections. The most frequent sites of infection were blood, LVAD drivelines, and central venous catheters, representing 61% of all infections. At the time of LVAD implantation, 13 of 60 patients (22%) had culture-proven infections. In spite of an increased incidence of subsequent infection (77% vs 40%), there were no differences in rates of mortality (31% vs 26%), LVAD endocarditis, (23% vs 11%) and eventual transplantation (62% vs 57%) between these patients and those without periimplantation infections. Although the overall mortality rate was not influenced by infections during LVAD support (28% vs 26%), the development of LVAD endocarditis was associated with a high mortality rate. Finally, although patients with infections during LVAD support had significantly longer median support times than those who remained infection free (101 vs 49 days, respectively), there was no difference in the rate of successful transplantation (59% vs 58%) or in the rate of infection after transplantation (35% vs 28%). CONCLUSIONS: Infections are common in patients undergoing LVAD support, but they do not adversely affect survival, the rate of successful transplantation, or the incidence of posttransplantation infection. Periimplantation infections may increase the risk of subsequent infections, but they also do not influence survival or transplantability. Patients with development of LVAD endocarditis are at increased risk for morbidity and death and require early and aggressive therapy, potentially including device explantation.

Adolescent↗

Hypoxia-induced exocytosis of endothelial cell Weibel-Palade bodies. A mechanism for rapid neutrophil recruitment after cardiac preservation.

The period of hypoxia is an important priming event for the vascular dysfunction that accompanies reperfusion, with endothelial cells (ECs) and neutrophils (PMNs) playing a central role. We hypothesized that EC Weibel-Palade (WP) body exocytosis during the hypoxic/ischemic period during organ preservation permits brisk PMN recruitment into postischemic tissue, a process further amplified in an oxidant-rich milieu. Exposure of human umbilical vein ECs to a hypoxic environment (pO2 approximately 20 torr) stimulated release of von Willebrand factor (vWF), stored in EC WP bodies, as well as increased expression of the WP body-derived PMN adhesion molecule P-selectin at the EC surface. Increased binding of 111In-labeled PMNs to hypoxic EC monolayers (compared with normoxic controls) was blocked with a blocking antibody to P-selectin, but was not affected by a nonblocking control antibody. Although increased P-selectin expression and vWF release were also noted during reoxygenation, hypoxia alone (even in the presence of antioxidants) was sufficient to increase WP body exocytosis. To determine the relevance of these observations to hypothermic cardiac preservation, during which the pO2 within the cardiac vasculature declines to similarly low levels, experiments were performed in a rodent (rat and mouse) cardiac preservation/transplantation model. Immunodepletion of recipient PMNs or administration of a blocking anti-P-selectin antibody before transplantation resulted in reduced graft neutrophil infiltration and improved graft survival, compared with identically preserved hearts transplanted into control recipients. To establish the important role of endothelial P-selectin expression on the donor vasculature, murine cardiac transplants were performed using homozygous P-selectin deficient and wild-type control donor hearts flushed free of blood/platelets before preservation/transplantation. P-selectin-null hearts transplanted into wild-type recipients demonstrated a marked (13-fold) reduction in graft neutrophil infiltration and increased graft survival compared with wild-type hearts transplanted into wild-type recipients. To determine whether coronary endothelial WP exocytosis may occur during cardiac preservation in humans, the release of vWF into the coronary sinus (CS) was measured in 32 patients during open heart surgery. CS samples obtained at the start and conclusion of the ischemic period demonstrated an increase in CS vWF antigen (by ELISA) consisting of predominantly high molecular weight multimers (by immunoelectrophoresis). These data suggest that EC WP exocytosis occurs during hypothermic cardiac preservation, priming the vasculature to recruit PMNs rapidly during reperfusion.

Animals↗

Experience with right ventricular assist devices for perioperative right-sided circulatory failure.

BACKGROUND: Right-sided circulatory failure remains a significant source of morbidity and mortality for both cardiac transplant and left ventricular assist device recipients. METHODS: We reviewed our experience with 11 patients who required a right ventricular assist device (RVAD) after either orthotopic heart transplantation or left ventricular assist device implantation. Variables analyzed included total time of RVAD support, hemodynamic and hematologic parameters, and parameters of end-organ perfusion. These were assessed at five time points: (1) at least 2 weeks before RVAD implantation, (2) intraoperatively just before RVAD insertion, (3) while on RVAD support, and, for those who survived, (4) just before RVAD explantation, and (5) off RVAD support. Survival was assessed as the ability to be weaned successfully from RVAD support. Urine output and serum transaminase levels were recorded throughout the period of RVAD support. RESULTS: Five patients received an ABIOMED 5000 BVS RVAD, and 6 received a Bio-Medicus centrifugal pump. Nine patients in the study underwent orthotopic heart transplantation and had development of right-sided circulatory failure from 0 to 96 hours after donor organ insertion, and 2 patients underwent left ventricular assist device implantation 12 to 48 hours before RVAD support. The mean time of RVAD support for survivors was 133.6 +/- 33.6 hours (range, 107 to 190 hours). Six patients were successfully separated from RVAD support, and 5 patients died while on RVAD support. Causes of death included sepsis (2), biventricular failure (2), and coagulopathy (1). Continuous arteriovenous hemodialysis was employed in 3 of 6 survivors and 1 of 5 nonsurvivors. CONCLUSIONS: Right ventricular assist devices work most effectively if implanted early enough to avoid significant, potentially irreversible end-organ injury. We liberally employ continuous arteriovenous hemodialysis, minimize the use of heparin immediately postoperatively, keep patients sedated, and continue RVAD support until the patient displays signs of hemodynamic and end-organ recovery as heralded by (1) a decrease in central venous pressure and, more importantly, a decrease in pulmonary artery diastolic pressure, (2) an increase in urine output, and (3) a decrease in serum transaminase levels.

Adolescent↗

Safety of repeat aprotinin administration for LVAD recipients undergoing cardiac transplantation.

BACKGROUND: Anecdotal reports of allergic and anaphylactic reactions after aprotinin therapy have raised concern that its repeat use may be associated with substantial morbidity. METHODS: To address this concern, we reviewed our experience with all patients who underwent implantation of a left ventricular assist device and subsequent cardiac transplantation with perioperative use of aprotinin. RESULTS: Twenty-three patients received full-dose aprotinin during left ventricular assist device implantation and subsequent cardiac transplantation. All patients tolerated primary exposure to aprotinin without complication. One episode of anaphylaxis after secondary exposure was treated with rapid institution of cardiopulmonary bypass. Although renal dysfunction was observed shortly after cardiac transplantation in 30.4% of patients, the effect was transient and occurred in the presence of cyclosporine. The one perioperative death after secondary exposure was unrelated to bleeding complications. No clinically evident thromboembolic events were documented. CONCLUSIONS: Primary and secondary exposure to aprotinin during operation with cardiopulmonary bypass is associated with limited intraoperative blood use, a low incidence of transient renal dysfunction and anaphylaxis, a rare need of reoperation for bleeding, and no clinical thromboembolic events.

Adult↗

Low thromboembolic risk without anticoagulation using advanced-design left ventricular assist devices.

BACKGROUND: A major limitation of cardiac assist devices has been the high incidence of thromboembolic events and their requirement for systemic anticoagulation. The Thermo Cardiosystems HeartMate 1000 IP left ventricular assist device (LVAD) employs a design that may reduce thromboembolic risk and obviate the need for systemic anticoagulation. METHODS: Two hundred twenty-three patients with nonreversible heart failure were supported with the HeartMate LVAD as a bridge to heart transplantation. All patients were monitored prospectively for thromboembolic events. Anticoagulation regimens and occurrence of subclinical thromboembolic events, including those seen by transcranial Doppler examinations in selected patients, were also recorded. RESULTS: Total time of LVAD support use was 531.2 patient-months. Twenty-three patients (10%) received warfarin postoperatively for 42.4 patient-months (8.2% of total support time). Six patients (2.7%) had thromboembolic events, representing 0.011 events per patient-month of device use. CONCLUSIONS: The thromboembolic complication rate associated with this LVAD is acceptably low despite the minimal anticoagulation employed in this series, allowing consideration of long-term device use for the treatment of heart failure.

Adolescent↗

Outpatient left ventricular assist device support: a destination rather than a bridge.

BACKGROUND: To evaluate the feasibility and efficacy of outpatient left ventricular assist devices as a bridge to transplantation, we reviewed the initial clinical experience with this modality at our institution. METHODS: During January 1993 to November 1995, 12 male and 2 female patients with an average age of 47 +/- 17 years were supported for an average of 117 +/- 24 days with the Thermo Cardiosystems VE wearable left ventricular assist device. Seven patients were discharged home an average of 35 +/- 4 days after implantation. RESULTS: No device failures occurred, although 29 controller malfunctions were identified during 1,640 total support days. All patients were able to safely maintain their devices. Outflow graft bleeding and driveline infection were responsible for two readmissions. No long-term anticoagulation treatment was used; one small thromboembolic episode occurred, but without significant long-term sequelae. CONCLUSIONS: None of the 7 patients released from the hospital died, and all were able to successfully maintain their devices at home. Hospital discharge of patients supported with left ventricular assist devices has allowed long-term evaluation of this technology, and the findings should prompt study of their use as a long-term alternative treatment to medical management for congestive heart failure.

Adolescent↗

Development of an intraluminal device for the treatment of aortic regurgitation: prototype and in vitro testing system.

OBJECTIVES: Development of an intraluminal device to reduce aortic regurgitation could provide a strategy intermediate between medical treatment and aortic valve replacement. An initial prototype and a testing system have been designed. METHODS: Aortic valves obtained from heart transplant recipients were explanted and assessed in a mock circulatory loop with resistive and capacitive elements, including pressure-flow characteristics, similar to those of a normal arterial system. Normal heart function was simulated by a pulsatile ventricular-assist device. Pressure on each side of the valve and flow through the valve were recorded, allowing the calculation of regurgitant fractions and transvalvular gradients. Six solid geometrically differing obturators were tested. RESULTS: All six designs resulted in significant reduction in aortic regurgitation (p < 0.0001), ranging from 15% to 38% improvement compared with control values. Small increases in transvalvular gradients (from 0 to 7 mm Hg) were also noted. DISCUSSION: Initial results suggest that an intraluminally placed obturator can reduce aortic regurgitation without creating clinically significant transvalvular gradients. These initial in vitro experiments demonstrate the feasibility of an intraluminal device for the treatment of aortic valve disease, and further investigation is warranted.

Aortic Valve↗

Miniature axial flow pump for ventricular assistance in children and small adults.

We investigated the efficacy of the Jarvik 2000 intraventricular assist device (Jarvik Research, Inc., New York, N.Y.) in an ovine model. The device is an axial flow pump measuring 1.8 cm in diameter by 5 cm long, has a displacement volume of 12 ml, and can deliver flow from 2 to 7 L/min. Seven devices were implanted through a left thoracotomy into the left ventricle with an outflow graft to the descending aorta. Animals were treated with warfarin sodium and aspirin to maintain prothrombin times approximately 1.5 times control. Animals were followed up for 3 to 123 days. Two animals died of operative complications at days 3 and 5. One device failed at 58 days because of thrombus formation at the inflow side of the impeller. The remaining four animals were killed at days 19, 42, 42, and 123, respectively, because of broken electric power cables. Hematocrit values rose significantly higher than preoperative levels (22.8% +/- 3.8% to 30.5% +/- 3.4%); premortem elevations of values higher than baseline values of plasma free hemoglobin (10.4 +/- 7.8 mg/dl to 17.1 +/- 7.4 mg/dl) and lactate dehydrogenase (391.5 +/- 113.7 units/L to 771.2 +/- 370.8 units/L) were statistically insignificant. Serum creatinine and bilirubin levels were normal. No end-organ dysfunction arising from long-term support was evident clinically or at postmortem examination, nor was there any evidence of embolism or damage to intracardiac structures. We found the Jarvik 2000 intraventricular assist device to be easily implantable, safe, nonhemolytic, and able to provide physiologic flow with power requirements under 10 watts.

Adult↗

Left ventricular assist devices. Psychosocial burden and implications for heart transplant programs.

Left ventricular assist devices (LVADs) driven by external sources and capable of sustaining life over weeks to months as a bridge to heart transplantation have been implanted in over 300 patients in the United States. Because of the limited availability of organs for transplantation, the remarkable degree to which LVADs reverse end-organ dysfunction, and patient acceptance, proposals for home LVAD treatment and for use of the LVAD as a permanent treatment for heart failure are being considered. LVAD therapy is associated with characteristic psychiatric and psychosocial problems, however, which must be addressed to optimize results. Among the first 30 LVAD patients treated at our center, psychiatric interventions were frequently required for family stress, major depression, organic mental syndromes, and serious adjustment disorders. Psychiatric problems most often occurred in patients with ongoing medical complications following LVAD implantation, and often significantly impaired rehabilitation. Both depression and organic mental syndromes were frequently associated with preexisting cerebrovascular disease, which was sometimes occult, and with strokes complicating LVAD therapy. Aggressive treatment of depression played a major role in improving functional status. LVADs may decompress heart transplant waiting lists and make it possible to optimize patients' physiological and functional status before transplantation. With increased LVAD use, however, neuropsychiatric factors can be expected to play a large role in determining quality of life and outcome both before and after heart transplantation.

Activities of Daily Living↗

cAMP-mediated vascular protection in an orthotopic rat lung transplant model. Insights into the mechanism of action of prostaglandin E1 to improve lung preservation.

Prostaglandin E1 (PGE1) is often added to the donor pulmonary flush solution to enhance clinical lung preservation for transplantation. Although PGE1 is thought to act as a pulmonary vasodilator during the harvest period, the precise mechanism(s) of action whereby PGE1 enhances lung preservation is unknown. Because cAMP levels decline in endothelial and vascular smooth muscle cells exposed to hypoxia, we hypothesized that a PGE1-mediated increase in cAMP levels within the preserved lungs might improve pulmonary vascular homeostasis following lung transplantation. Rat lungs demonstrated a time-dependent decline in cAMP levels during hypothermic storage, with cAMP levels significantly increased by PGE1 supplementation (approximately 2-fold by 6 hours, P < .0005). To test whether augmenting cAMP levels may enhance lung preservation, experiments were performed using an orthotopic rat left lung transplant model. Compared with controls, supplementing the preservation solution with the membrane-permeable cAMP analogue dibutyryl-cAMP resulted in dose-dependent preservation enhancement, marked by reduced pulmonary vascular resistance (6.0-fold, P < .01), improved arterial oxygenation (3.0-fold, P < .01), reduced graft neutrophil infiltration (1.5-fold, P < .05), and improved recipient survival (7.0-fold, P < .005). Similar preservation enhancement was observed with another cAMP analogue (8-bromo-cAMP) or the phosphodiesterase inhibitor indolidan. Stimulating the cAMP second messenger system by PGE1 supplementation resulted in marked hemodynamic benefits and improved recipient survival, in parallel with reduced graft neutrophil infiltration, vascular permeability, and platelet deposition. These beneficial effects of PGE1 were abrogated by simultaneous administration of the cAMP-dependent protein kinase antagonist Rp-cAMPS. Although an arterial vasodilator (minoxidil) resulted in significant pulmonary vasodilation during harvest, it lacked other nonvasodilating effects of PGE1 and resulted in poor preservation. These data show that harvest vasodilation by itself is insufficient to enhance lung preservation and that PGE1 enhances lung preservation by stimulating the cAMP-dependent protein kinase and promoting non-vasodilatory mechanisms of pulmonary protection.

Alprostadil↗