Clinical evaluation of setting pump occlusion by the dynamic method: effect on flow.

Pump manufacturers recommend setting roller pump occlusion such that the level of a 100 cm column of crystalloid drops 2.5 cm/min (Sarns, 8000 Modular Perfusion System, operator's manual, roller pump software version 2.3L. May 1993; 2.1-2.14). Though this almost occlusive setting ensures accurate pump flow, it has been shown to cause more hemolysis than nonocclusive pumps (Noon GP, Kane LE, Feldman L et al. Reduction of blood trauma in roller pumps for long-term perfusion. World J Surg 1985; 9: 65-71). We conducted a clinical study (n = 19) to compare the standard occlusion method with the dynamic method and to determine the accuracy of flow for the nonocclusive pump. Standard occlusion was set by clamping the pump tubing distal to the arterial line filter and timing the drop in pump outlet pressure as indicated by a pressure transducer connected to the filter. The occlusion setting, expressed in mmHg/s, was recorded for each roller at two specific points along the raceway. The pump was then set nonocclusively with the dynamic method using the Better Header (BH) (Circulatory Technology, Oyster Bay, NY, USA). Readings of the change in pressure in the same two selected points on the raceway were taken. The latter was repeated after discontinuation of bypass. Flow was recorded throughout the procedure from both roller pump output display and a flow meter (Model #109 Transonic, Ithaca, NY, USA). The average drop in pump outlet pressure for the standard method was 1.3 +/- 4.0 (range 0-18 mmHg/s), and for the dynamic method was 38 +/- 28 (range 1.2-89 mmHg/s). Off bypass, the average reading was 44 +/- 38 (range 2.0-103 mmHg/s). Regression analysis indicates that patient flow, when corrected for retrograde flow by the dynamic method, equals 1.003 x revolutions per minute + 40 ml/min (r2 = 0.964). The average error between indicated pump flow, corrected for retrograde flow, was -1% (range from -6.7 to 6.6%). We conclude that the BH allows nonocclusive setting (30 times less than our standard method) without sacrificing pump flow accuracy.

Cardiopulmonary Bypass↗

Role of cardiopulmonary bypass in single vessel coronary revascularization: implications for MID-CABG.

BACKGROUND: Minimally invasive direct coronary artery bypass grafting (MID-CABG) is being utilized for the treatment of coronary artery disease in selected patients. This innovative procedure has generated numerous technical issues relating to coronary revascularization, including whether to perform the revascularization with or without cardiopulmonary bypass (CPB). METHODS: We addressed this issue indirectly by analyzing the 1995 New York State CABG registry, comparing patients who had single vessel bypass without CPB (Non-CPB Group) to a similar cohort of patients who had CABG performed on CPB (CPB Group). The database showed stratification of patients selected for bypass grafting without CPB to a significantly higher risk group, as shown by increased age, higher incidence of reoperation, transmural MI, congestive heart failure, carotid/cerebrovascular disease, and peripheral vascular disease. RESULTS: Patients in the Non-CPB Group had a higher incidence of postoperative malignant ventricular arrhythmias and heart block requiring pacemaker insertion. Otherwise, the incidence of postoperative complications was similar between the two groups. CONCLUSIONS: There were no statistical differences in the hospital mortality or the length of hospitalization between the two groups. In conclusion, the data showed a definite trend toward doing higher risk cases off CPB. These cases had an acceptable early morbidity and mortality outcome. The results were comparable to a group of lower risk patients with single vessel CABG done on cardiopulmonary bypass. However, further follow-up are required to evaluate long-term outcomes and confirm the utility of this surgical option.

Aged↗

Platelet transfusions are associated with the development of anti-major histocompatibility complex class I antibodies in patients with left ventricular assist support.

BACKGROUND: Preformed anti-human leukocyte antigen (HLA) antibodies delay heart transplantation in patients with left ventricular assist devices (LVAD) because of difficulty in finding crossmatch-negative donors. These antibodies may also be associated with adverse outcome after transplantation. METHODS: In a retrospective analysis of 40 patients with LVAD at Columbia-Presbyterian Medical Center between 1990 to 1996, age, sex, diagnosis, race, duration of support, transfusions, and infections were studied by univariate and multivariate analysis as predictors for development of either anti-HLA class I (anti-I) or anti-HLA class II (anti-II) immunoglobulin G (IgG) or M (IgM) antibodies. RESULTS: Eighteen (45%) patients had development of anti-I and 20 (50%) had development of anti-II antibodies over the study period. Median time for LVAD support was 142 days (range 35 to 439). Only total number of perioperative platelet transfusions predicted the development of anti-I IgG antibodies (p = .04). No other associations were found for development of anti-I IgM or anti-II antibodies of either IgG or IgM specificity. Patients who had development of anti-I IgG received a mean of 13.9 (SE +/- 2.6) units of platelets compared with a mean of 7.7 (SE +/- 2.3) units in those who did not (p = .01). By Kaplan-Meier analysis, at the median duration of follow-up, 8% of patients receiving < 6 units were predicted to have development of anti-I antibodies compared with 63% receiving > 6 units (p = .002). In the last 7 patients, leukocyte filters were used to decrease the antigenic load during platelet and red blood cell transfusions. Only 1 of 7 (14%) patients had development of anti-HLA antibodies compared with 31 of 33 (94%) in whom filters were not used (p < .005). CONCLUSIONS: These results indicate that platelet transfusion during LVAD implantation is a risk factor associated with development of HLA class I IgG antibodies. Use of leukocyte filters during platelet transfusion may decrease the risk of development of anti-HLA antibodies.

Antibody Formation↗

Complement activation as a cause for primary graft failure in an isogeneic rat model of hypothermic lung preservation and transplantation.

Although agents that inhibit complement activation may be beneficial in discordant xenotransplantation, it is not known whether local complement activation occurs and is deleterious after isogeneic lung transplantation. Lungs were harvested from Lewis rats subjected to 4 degrees C 6-hr preservation followed by transplantation into strain-, gender-, and weight-matched recipients. Transplanted lungs demonstrated increased immunostaining for C5b-9 compared with nontransplanted controls, confirming local complement activation in this isograft model. To investigate the physiologic relevance of complement activation in the transplanted lung, the native pulmonary artery was ligated after transplantation, and pulmonary vascular resistance (mmHg/ml/min), arterial oxygenation (mmHg), graft neutrophil infiltration (myeloperoxidase activity, deltaAbs 460 nm/min), and recipient survival were measured at 30 min. Animals received either saline (control; n=22) or soluble complement receptor type-1 (sCR1, 15 mg/kg; n=19) 2 min before reperfusion. Animals treated with sCR1 showed a marked reduction in serum complement hemolytic activity (CH50; 90% lower than that of control animals, P<0.001). Compared with controls, sCR1-treated animals showed reduced pulmonary vascular resistance (2.9+/-1.1 vs. 8.5+/-1.5 mmHg/ml/min, P<0.05), improved arterial oxygenation (194+/-34 vs. 91+/-17 mmHg, P<0.05), decreased neutrophil infiltration (35% decrease, P<0.005), and improved recipient survival (74% vs. 23%, P<0.005). In parallel with the reduction in complement hemolytic activity in sCR1-treated animals, immunohistology of the transplanted lung revealed decreased C5b-9 deposition compared with controls. Taken together, these data indicate that complement activation occurs after lung preservation and transplantation in an isograft model, and that inhibiting complement activation improves outcome after transplantation.

Animals↗

What is 'minimally invasive' coronary bypass surgery? Experience with a variety of surgical revascularization procedures for single-vessel disease.

BACKGROUND: Although the use of small incisions is theoretically appealing, it has been argued that the true advantage of minimally invasive approaches to myocardial revascularization lies in the avoidance of cardiopulmonary bypass. METHODS: Of 25 patients referred for surgical revascularization of single-vessel coronary disease, 20 elected to undergo a minimally invasive coronary artery bypass grafting (MICABG) procedure, while 5 opted to have conventional surgery with cardiopulmonary bypass (CPB). Patients having MICABG underwent single-vessel revascularization without CPB, via limited anterior thoracotomy, hemisternotomy, or median sternotomy. Intraoperatively, hemodynamics, anastomotic time, and total operative time were recorded. Postoperatively, length of hospital stay, incidence of myocardial infarction, indexes of end-organ function, and morbidity rates were recorded. In addition, patient questionnaires were used to assess subjective end points such as postoperative pain, wound drainage, and quality of life. RESULTS: Fifteen of 20 patients undergoing MICABG underwent revascularization without CPB, while 4 were converted to standard coronary artery bypass grafting with CPB due to technical reasons and 1 for intraoperative ventricular fibrillation. Patients undergoing MICABG had no perioperative myocardial infarctions, while those having CPB had two infarctions (20%). Furthermore, there were no differences in length of stay or postoperative morbidity among the various approaches, while the MICABG procedures, especially via median sternotomy, were associated with shorter operative times. CONCLUSIONS: The advantage of MICABG lies mainly in the avoidance of CPB. Thus, we advocate that surgeons initially utilize the median sternotomy and limited skin incision for MICABG to assure adequate exposure, technical precision, and patient safety. After a reasonable level of technical proficiency and experience are attained, the limited anterior thoracotomy approach can be used.

Cardiopulmonary Bypass↗

A prospective randomized trial of arginine vasopressin in the treatment of vasodilatory shock after left ventricular assist device placement.

BACKGROUND: Vasodilatory shock requiring catecholamine pressors occurs in some patients following cardiopulmonary bypass. Prompted by a clinical observation, we investigated the use of vasopressin as a treatment for this syndrome in a randomized, controlled trial. METHODS AND RESULTS: Patients undergoing placement of a left ventricular assist device (n=23) were evaluated for post-bypass vasodilatory shock requiring catecholamine pressors, and consecutive eligible subjects (n=10) were evenly randomized to blinded intravenous vasopressin or saline placebo. Vasopressin (0.1 U/min) increased mean arterial pressure (57+/-4 to 84+/-2 mm Hg, P<.001) and systemic vascular resistance (813+/-113 to 1188+/-87 dyne-s/cm5, P<.001), with decreased norepinephrine administration. There was no significant response to saline, but in three subjects who crossed over, blinded vasopressin increased mean arterial pressure (69+/-8 to 93+/-4 mm Hg) and systemic vascular resistance (898+/-88 to 1443+/-72 dyne-s/cm5) with decreased norepinephrine administration. Plasma vasopressin concentrations prior to randomization clustered in two groups: one (n=5) with concentrations inappropriately low for the degree of hypotension (8.4+/-2.1 pg/mL) and a second (n=3) with moderately elevated levels (33.7+/-1.6 pg/mL); vasopressin increased mean arterial pressure in the low vasopressin group from 57+/-4 to 85+/-2 mm Hg (P<.01) and in the high vasopressin group from 68+/-8 to 86+/-4 mm Hg. CONCLUSIONS: Vasopressin is an effective pressor in vasodilatory shock after cardiopulmonary bypass. An absolute vasopressin deficiency was observed in the majority of patients, but all subjects responded to vasopressin administration.

Arginine Vasopressin↗

Bridge experience with long-term implantable left ventricular assist devices. Are they an alternative to transplantation?

BACKGROUND: If long-term use of left ventricular assist devices (LVADs) as bridges to transplantation is successful, the issue of permanent device implantation in lieu of transplantation could be addressed through the creation of appropriately designed trials. Our medium-term experience with both pneumatically and electrically powered ThermoCardiosystems LVADs is presented to outline the benefits and limitations of device support in lieu of transplantation. METHODS AND RESULTS: Detailed records were kept prospectively for all patients undergoing LVAD insertion. Fifty-eight LVADs were inserted over 5 years, with a survival rate of 74%. Mean patient age was 50 years, and duration of support averaged 98 days. Although common, both preexisting infection and infection during LVAD support were not associated with increased mortality or decreased rate of successful transplantation. Thromboembolic complications were rare, occurring in only three patients (5%) despite the absence of anticoagulation. Ventricular arrhythmias were well tolerated in all patients except in cases of early perioperative right ventricular failure, with no deaths. Right ventricular failure occurred in one third of patients and was managed in a small percentage by right ventricular assist device (RVAD) support and/or inhaled nitric oxide therapy. There were no serious device malfunctions, but five graft-related hemorrhages resulted in two deaths. Finally, a variety of noncardiac surgical procedures were performed in LVAD recipients, with no major morbidity and mortality. CONCLUSIONS: Over all, our medium-term experience with implantable LVAD support is encouraging. Although additional areas of investigation exist, improvements in patients selection and management together with device alterations that have reduced the thromboembolic incidence and facilitated patient rehabilitation lead us to believe that a prospective, randomized trial is indicated to study the role that LVADs may have as an alternative to medical management.

Aged↗

Vasopressin deficiency contributes to the vasodilation of septic shock.

BACKGROUND: The hypotension of septic shock is due to systemic vasodilation. On the basis of a clinical observation, we investigated the possibility that a deficiency in vasopressin contributes to the vasodilation of septic shock. METHODS AND RESULTS: In 19 patients with vasodilatory septic shock (systolic arterial pressure [SAP] of 92 +/- 2 mm Hg [mean +/- SE], cardiac output [CO] of 6.8 +/- 0.7 L/min) who were receiving catecholamines, plasma vasopressin averaged 3.1 +/- 1.0 pg/mL. In 12 patients with cardiogenic shock (SAP, 99 +/- 7 mm Hg; CO, 3.5 +/- 0.9 L/min) who were also receiving catecholamines, it averaged 22.7 +/- 2.2 pg/mL (P < .001). A constant infusion of exogenous vasopressin to 2 patients with septic shock resulted in the expected plasma concentration, indicating that catabolism of vasopressin is not increased in this condition. Although vasopressin is a weak pressor in normal subjects, its administration at 0.04 U/min to 10 patients with septic shock who were receiving catecholamines increased arterial pressure (systolic/diastolic) from 92/52 to 146/66 mm Hg (P < .001/P < .05) due to peripheral vasoconstriction (systemic vascular resistance increased from 644 to 1187 dyne.s/cm5; P < .001). Furthermore, in 6 patients with septic shock who were receiving vasopressin as the sole pressor, vasopressin withdrawal resulted in hypotension (SAP, 83 +/- 3 mm Hg), and vasopressin administration at 0.01 U/min, which resulted in a plasma concentration (approximately 30 pg/mL) expected for the level of hypotension, increased SAP from 83 to 115 mm Hg (P < .01). CONCLUSIONS: Vasopressin plasma levels are inappropriately low in vasodilatory shock, most likely because of impaired baroreflex-mediated secretion. The deficiency in vasopressin contributes to the hypotension of vasodilatory septic shock.

Adult↗

Failure to express the P-selectin gene or P-selectin blockade confers early pulmonary protection after lung ischemia or transplantation.

Endothelial P-selectin expression contributes to the first wave of neutrophil (polymorphonuclear leukocyte: PMN) influx in several inflammatory conditions. Although remote tissue ischemia, such as a crush injury to the hindlimb, may result in P-selectin-mediated pulmonary leukosequestration, it is not known whether the lungs exhibit a similar response after hypothermic preservation or when subjected to a direct ischemic insult. To determine if P-selectin may mediate early primary graft failure, left lungs harvested from male Lewis rats were preserved for 6 hr at 4 degrees C and transplanted orthotopically into isogeneic recipients. Recipients immunodepleted of PMNs before transplantation demonstrated improved graft function; pulmonary vascular resistance was reduced approximately 6-fold, arterial oxygenation was increased approximately 3-fold, and recipient survival was increased approximately 4-fold (P < 0.05, 0.05, and 0.005, respectively). Administration of a blocking anti-P-selectin IgG 10 min before reperfusion diminished graft PMN infiltration and resulted in improved graft function and recipient survival compared with controls. To establish the role of P-selectin in normothermic pulmonary ischemia, mice were subjected to temporary left pulmonary artery ligation. After functional removal of the nonischemic right lung, mice deletionally mutant for the P-selectin gene (P-selectin-/-) exhibited reduced PMN infiltration (approximately 2-fold), improved arterial oxygenation (approximately 2-fold), and improved survival (approximately 3-fold) compared with P-selectin +/+ control mice (P < 0.05, 0.01, and 0.05, respectively). These studies isolate and identify the central role of a single gene product (P-selectin) in early PMN recruitment and tissue injury after frank pulmonary ischemia and in the setting of lung transplantation after hypothermic preservation.

Animals↗

Circulatory resuscitation with left ventricular assist device support reduces interleukins 6 and 8 levels.

BACKGROUND: Elevated tumor necrosis factor serum levels have been reported in patients with severe congestive heart failure. This study was designed to characterize the cytokine profile in patients with acute circulatory collapse. METHODS: Blood drawn from 14 consecutive patients within 24 hours before undergoing left ventricular assist device placement and after at least 30 days of mechanical assistance or before transplantation was assayed for levels of interleukin 6, interleukin 8, and tumor necrosis factor-alpha. RESULTS: Interleukin 6 level was elevated in 11 (79%), interleukin 8 in 10 (71%), and tumor necrosis factor in 2 (14%) of the 14 patients. After hemodynamic recovery, interleukin 6 levels decreased from 33.6 +/- 9 pg/mL to 11.3 +/- 4 pg/mL (p = 0.05) and interleukin 8 levels decreased from 122 +/- 34 pg/mL to 19.7 +/- 8 pg/mL (p = 0.005). Tumor necrosis factor-alpha levels did not vary significantly; they were associated with infection in 2 left ventricular assist device recipients and normalized after left ventricular assist device support. All patients had resolution of circulatory shock after mechanical support and had improvement in parameters of end-organ function. CONCLUSIONS: Circulatory shock treated with left ventricular assist device placement is associated with a proinflammatory response similar to that seen in septic shock. The decrease in cytokine serum levels that follows hemodynamic recovery suggests that these cytokines may be markers of tissue damage and may modulate cardiac dysfunction.

Biomarkers↗

Evolving costs of long-term left ventricular assist device implantation.

BACKGROUND: To examine the long-term costs of implanting a left ventricular assist device, we reviewed the initial hospitalization and outpatient costs for 12 patients who received a vented electric left ventricular assist device, and projected the first-year costs. METHODS: We used the ratio-of-cost-to-charges method to measure hospital costs and payments for physician time. We examined time trends in the resource use of 50 pneumatic left ventricular assist device recipients, using actuarial techniques and regression modeling. RESULTS: The average actual cost of left ventricular assist device support is $221,313 over an average of 9.5 months. If there had been no Food and Drug Administration regulatory policy precluding hospital discharge before 30 days, this value would have been $201,148. Based on this latter figure, the average predicted first-year cost is $219,139. The length of the intensive care unit stay, one of the most costly components of care, decreased significantly over time. CONCLUSIONS: The high costs of left ventricular assist device implantation are similar to those reported for cardiac transplantation. Given their success in supporting survival, we anticipate that these devices will be similarly cost-effective. However, further research is imperative to determine the cost-effectiveness of these devices beyond the introductory phase, when costs, benefits, and Food and Drug Administration requirements have stabilized.

Actuarial Analysis↗

Quality of life with an implanted left ventricular assist device.

BACKGROUND: With the increasing use of left ventricular assist devices (LVADs) for longer-term support of patients awaiting cardiac transplantation, we must now consider whether to use these devices as alternatives to medical therapy when biologic hearts are needed but not forthcoming. This expansion of use depends as much on quality of life as it does on survival. To draw an inference about long-term quality of life with implanted LVADs, we studied "bridged" patients at our institution. METHODS: We elicited, by standard gamble, the utilities (preferences) of bridged patients at three points in their care: before LVAD implantation, during LVAD support, and after cardiac transplantation. RESULTS: Utility was 0.548 (+/-0.276) before implantation, 0.809 (+/-0.136) during LVAD support, and 0.964 (+/-0.089) after transplantation. For patients interviewed during all three states of health, the utilities were significantly different (p = 0.0009 by analysis of variance). CONCLUSIONS: The quality of life with an LVAD was substantially better than with medical therapy, on par with renal transplantation (as established by others), and not as good as after cardiac transplantation. These results portend an acceptable quality of life for long-term use of LVADs for patients with end-stage heart failure and contribute to the growing body of evidence supporting a clinical trial to test this new use.

Female↗

Improved results for postcardiotomy cardiogenic shock with the use of implantable left ventricular assist devices.

BACKGROUND: Over the past decade, the use of mechanical circulatory support in patients with postcardiotomy cardiogenic shock has resulted in hospital discharge rates of 25% to 40%. In an attempt to improve patient survival, we initiated a program of early insertion of an implantable Thermocardiosystems Incorporated Heartmate left ventricular assist device in patients who have circulatory failure after having undergone high-risk cardiac operations. METHODS: Between April 1993 and February 1997, 12 patients underwent insertion of an implantable left ventricular assist device for postcardiotomy cardiogenic shock after coronary artery bypass grafting. Indications for insertion included postoperative cardiogenic shock (7 patients), postoperative cardiac arrest (3 patients), and failure to wean from cardiopulmonary bypass (2 patients). RESULTS: The median time to device insertion was 3.5 days. The mean duration of left ventricular assist device support was 103 +/- 19 days (range, 2 to 225 days). Nine of 11 patients (82%) survived to undergo either transplantation (8 patients) or explantation (1 patient), with successful hospital discharge of all 9 patients. The major complication was device-related infection (42%). A single thromboembolism occurred in a patient with an infection. CONCLUSIONS: Long-term outcome after postcardiotomy cardiogenic shock is improved substantially with the use of an implantable left ventricular assist device early in the postoperative course. Access to such a device is an important consideration before undertaking a high-risk cardiac operation, and early implantation of the device is a critical factor in ensuring long-term survival.

Algorithms↗

The continuing evolution of mechanical ventricular assistance.

A great number of patients suffer and die of the sequelae of acute and chronic heart failure each year. Although advances in medical and surgical therapy have benefited many of these patients, most have disease that is refractory to any definitive therapy. For these patients cardiac transplantation is the only remaining hope. Unfortunately, because of the increasing demand for donor organs in the face of a fixed and limited supply, this option is available to only a small percentage of these patients. Even in patients accepted for transplantation, a significant waiting list mortality has been observed. A variety of VADs have been developed since the first successful case of mechanical cardiac assistance more than 30 years ago. These devices differ in basic mechanical function, method of insertion, and degree of implantability and thus have different indications and potential applications. Whereas the intraaortic balloon pump and centrifugal pumps are effective short-term support modalities, extracorporeal and implantable pulsatile devices have been used successfully for long-term support of patients with reversible and nonreversible cardiac failure. Although these pumps have most commonly been used as bridges to transplantation, increasing clinical experience has supported the notion of long-term mechanical assistance as a definitive therapy for patients with end-stage heart disease. Although complications, particularly infection and thromboembolism, pose significant challenges and long-term device reliability remains to be fully determined, available implantable devices appear to be capable of providing effective long-term support. As data are obtained from currently ongoing trials comparing VAD support with medical therapy for end-stage heart failure, ethical and economic issues will assume increasing importance.

Cardiac Output, Low↗

Cerebral dysfunction after coronary artery bypass grafting done with mild or moderate hypothermia.

OBJECTIVE: Ninety-nine patients undergoing elective coronary artery bypass grafting were enrolled in a prospective, randomized study to evaluate the incidence of cerebral dysfunction after "mild" or "moderate" hypothermia during cardiopulmonary bypass. METHODS: Patients were evaluated before and after operation before hospital discharge and in some cases at follow-up at least 6 weeks later with a complete neurologic examination (85 patients) and a battery of standard neuropsychometric tests (86 patients). RESULTS: Postoperative changes detected by neurologic examination consisted of the appearance of new primitive reflexes in both groups. No statistically significant differences in incidence were found. The neuropsychometric performances of the two groups were statistically similar by either event-rate or group-rate analysis. CONCLUSIONS: There is no detectable difference in postoperative cerebral dysfunction in patients undergoing coronary artery bypass grafting who are supported by cardiopulmonary bypass with either mild or moderate hypothermia.

Aged↗

Inhaled nitric oxide is not a negative inotropic agent in a porcine model of pulmonary hypertension.

BACKGROUND: Reports of pulmonary edema complicating inhaled nitric oxide therapy in patients with chronic heart failure and pulmonary hypertension have raised the concern that inhaled nitric oxide may have negative inotropic effects. METHODS AND RESULTS: We investigated the effect of multiple doses of inhaled nitric oxide (20, 40 and 80 ppm) on left ventricular contractile state in 10 open-chest pigs. Pressure-volume loops were generated during transient preload reduction to determine the end-systolic pressure-volume relationship and the stroke work-end-diastolic volume relation. Inhaled nitric oxide had no effect on systemic vascular resistance, cardiac output, end-systolic pressure volume relationship or stroke work-end-diastolic volume relation under normal conditions. After induction of pulmonary hypertension (intravenous thromboxane A2 analog), inhalation of nitric oxide (80 ppm) resulted in a reduction in pulmonary vascular resistance (mean +/- standard error of the mean) from 10.4 +/- 3 to 6.5 +/- 2 Wood units (p < 0.001) and in pulmonary artery pressure from 44 +/- 4 to 33 +/- 4 mm Hg (p < 0.05). Left ventricular end-diastolic volume rose from 53 +/- 9 ml to 57 +/- 10 ml (p = 0.02). No statistically significant change in cardiac output or systemic vascular resistance was observed. Inhaled nitric oxide had no effect on end-systolic pressure-volume relationship or stroke work-end-diastolic volume relation. CONCLUSIONS: In a porcine model of pulmonary hypertension, inhaled nitric oxide does not impair left ventricular contractile function. Therefore the cause of pulmonary edema observed in some patients receiving inhaled nitric oxide is not due to a negative inotropic action of this therapy.

Administration, Inhalation↗

Systolic ventricular interaction in normal and diseased explanted human hearts.

OBJECTIVE: The purpose of this study was to quantify the magnitude of interaction between the right and left ventricles in conditions of heart failure. METHODS: Human hearts were taken from transplant recipients diagnosed with diluted cardiomyopathy at the time of transplantation and were restored to beating condition with use of an isolated perfusion circuit. Left ventricular-right ventricular interaction was determined by ramping volume in the left ventricle while holding right ventricular volume constant. Right ventricular pressure gain was plotted against left ventricular pressure and the slope of the linear regression determined the left ventricular-right ventricular interaction. A similar procedure was used to determine right ventricular-left ventricular interaction. Two normal hearts were obtained from transplant donors not suitable for cardiac donation to serve as control hearts. RESULTS: Mean left ventricular-right ventricular interaction was 0.22 in the hearts with dilated cardiomyopathy compared with 0.06 in the control hearts. Mean right ventricular-left ventricular interaction was 0.14 in the hearts with dilated cardiomyopathy compared with 0.09 in the control hearts. A marked increase in left ventricular-right ventricular interaction was noted in the hearts with dilated cardiomyopathy compared with control hearts. Although observed values of right ventricular-left ventricular interaction also correspond to previously published results, no significant increase was observed in the dilated cardiomyopathy condition. CONCLUSIONS: These studies confirm previously published values for systolic ventricular interaction obtained with animal models and demonstrate a marked increase in the dependence of the right ventricle on left ventricular function to maintain systolic pressure generation during conditions of dilated cardiomyopathy.

Cardiomyopathy, Dilated↗