Search PubMed⌕ Search

Biomedical subjects

M Block

Publications and source records attributed to M Block.

At least 181 records · Page 10Linked to original sources

Clinical implications of lactose-positive breast secretions in nonpuerperal females.

Inappropriate milk-like secretion from the breasts is not infrequently encountered in patients. Usually these secretions have been identified as milk on the basis of their characteristic appearance, and only rarely has their identity as milk been proven by appropriate analysis. Since milk is chemically defined as a lactose-containing mammary secretion, the presence of lactose in a breast secretion identifies it as milk irrespective of its appearance or the presence of other constituents. Lactose can be readily identified by thin-layer chromatographic methods, which despite their inherent speed and sensitivity have not been widely utilized. A method using commercially prepared cellulose layers and a sandwich developing apparatus is presented in detail. This method utilizes current advances in chromatographic techniques and permits rapid and accurate identification of lactose in breast secretions. Such secretions from 10 nonpuerperal women were screened for the presence of lactose. The milk-like secretions from 8 contained varying amounts of lactose, which was not detectable in the secretions from the other 2. There was no correlation between the appearance of the secretion and the presence of lactose.

Breast↗

Nonpharmacological therapy for malignant ventricular arrhythmias: implantable defibrillator trials.

Implantable cardioverter-defibrillators (ICDs) are an important nonpharmacological option in the treatment of malignant ventricular arrhythmias. Technological advances in current devices permit nonthoracotomy implantation with transvenous lead systems using biphasic shocks. Decreasing device size has resulted in pectoral implantation. Battery longevity is still short in comparison with that of pacemakers. Lead failure rates as well as pacing thresholds are significantly higher than those for cardiac pacing lead systems. Other complications of ICD systems include infection, perforation, and thrombosis. The long-term performance of nonthoracotomy lead systems for ICD devices has now been extensively studied. Sudden death recurrence rates for these systems are less than 2% in 3 years and less than 5% at 5 years. Clinical trials with both monophasic and biphasic systems show a high degree of prevention of sudden death. Comparison of ICD outcome with that of drug therapy in three large retrospective studies and two small prospective randomized trials favors improved survival and sudden death prevention with device therapy. However, these studies need corroboration from large prospective trials. Two large prospective trials, CIDS and the AVID study, are now in progress to address this issue.

Amiodarone↗