Search PubMed⌕ Search

Biomedical subjects

M Bernstein

Publications and source records attributed to M Bernstein.

At least 253 records · Page 14Linked to original sources

Decreased anion gap associated with monoclonal and pseudomonoclonal gammopathy.

Nine patients with monoclonal and one with pseudomonoclonal gammopathy were found to have a decreased anion gap. Eight of the patients had multiple myeloma, one has plasma cell leukemia and one had chronic active hepatitis. In all of the the decreased anion gap was associated with an increased concentration of IgG greater than 5 g/dl.

Adult↗

Lecithin:cholesterol acyltransferase initial fractional rates of esterification in human and rat serum during development.

The initial fractional rates of cholesterol esterification were measured in human cord serum, in a group of apparently healthy "young adults" (mean age +/- S.D. 32 +/- 5 years), in a group of "middle aged" adults (51 +/- 8 years) with normal coronary angiograms and in newborn, 10-, 20-, 45-, 180- and 365-day-old rats. The initial fractional rate of esterification was inversely related to serum cholesterol levels in humans and, with the exception of newborns, also in rats. A theory of lecithin:cholesterol acyltransferase participation in cholesterol metabolism is discussed.

Acyltransferases↗

Clinical styles and motivation: a study of laboratory test use.

The study reported in this paper examines clinical reasoning styles with a focus on laboratory utilization. A stratified sample of 80 physicians participated in the solution of a simulated patient management problem. The analysis focuses on variation in the portfolio of laboratory tests ordered as a function of practice setting (e,g., physicians in practice versus physicians in training). The study also examines the response of physicians to the imposition of constraints on ordering, as well as behavior, when unlimited ordering capacity is provided. Overall, the data profiles emerging from the analysis indicate the variety inherent in physician decision-making strategies, and point to the necessity of employing a cautious and flexible approach toward any general scheme of constraints upon medical diagnostic procedures;

British Columbia↗

Clinical use of NISR 440 polycarbonate membrane for hemodialysis.

1. In order to accredit the NISR440 Polycarbonate Membrane for clinical studies, the following was accomplished and/or established: a. Casting and synthesis were increased from the laboratory level to production scale. b. Quality control of permeabilities and physical properties was within +/- 5%, from membrane lot to lot and within the same roll. c. The target properties of the Artificial Kidney Program (NIH) were reached(7): 1) Middle M. W. solute permeability of marked molecules was established by 3 different laboratories and averaged: Vitamin B12 - 296 x Cuprophan¿; Inulin 3.6 x Cuprophan¿; Bacitracin 2.94 x Cuprophan¿. 2) Low M. W. species permeabilities were approximately the same as Cuprophan¿, to avoid a depletion syndrome. 3) Hydraulic permeability was essentially the same as Cuprophan¿ (UF rate 1.25 to 2.0 x Cuprophan¿) to avoid dehydration and hypotension. 4) Burst strength was 1.5 to 2.0 x Cuprophan¿. d. Toxicology studies were all negative in spot and in serial lot testing. e. Non-thrombogenicity tests (Lindholm test) were up to 36.6% better than Cuprophan¿. f. No protein adsorption was found. g. The membrane could be produced in the wet and dry state with the same permeability and physical properties. 2. In an earlier clinical study at USC, it was established that: a. There were no toxic effects manifested in patients in 25 episodic studies. b. Clearances forlow M. W. solutes and hydraulic permeabilities were, as targeted, approximately the same as Cuprophan¿. c. In 4 1/2 mos of a double blind study of 6 patients, no significant toxic effects were noted for either the patients on Cuprophan¿ or NISR 440 Polycarbonate Membrane. Two patients had an increase of hematocrit. 3. The ability to heat seal the membrane in the periphery and in channels through many layers, combined with its relative rigidity when wet, make possible clinical hemodialyzer designs approximately the size of a package of cigarettes and inexpensive to produce.

Adult↗