Case challenges in knee surgery: what would you do?

In an interactive case presentation session, the faculty discussed management of complex primary and revision knee arthroplasty issues. Principles discussed included: preoperative evaluation of the failed knee arthroplasty, intra-articular versus extra-articular deformity correction, ligamentous balancing, managing the unstable total knee arthroplasty, bone deficiency management, rotational positioning of prosthetic components, selection of articular constraint in the revision knee, and extensor mechanism balancing.

Arthroplasty, Replacement, Knee↗

Intraoperative monitoring for safety of bilateral total knee replacement.

Cardiopulmonary hemodynamics in 79 consecutive patients who had one-stage bilateral total knee replacements were monitored prospectively with a pulmonary artery catheter. The pulmonary vascular resistance, wedge pressure, pulmonary artery pressure, and systemic vascular resistance were measured before skin incision, 5 to 10 minutes after implanting the first total knee replacement, and after the second knee replacement. The second knee replacement was cancelled in five patients because the pulmonary vascular resistance after the first knee replacement was more than double the baseline, or above 200 dyne/second/cm(5). No patient had clinical symptoms of fat embolism during the postoperative course. Patient predictive factors, or the use of pulse oximetry readings instead of a pulmonary artery catheter, were not predictive of intraoperative elevation of pulmonary vascular resistance. For this reason, the safety of this operation for the patient requires that intraoperative measurement of hemodynamic parameters of embolism be done.

Aged↗

Contrary view: wear is not an issue.

Wear was not an issue with total knee replacements that had a round-on-round design such as the Total Condylar and the Insall-Burstein prostheses. As long as designs do not try to reproduce normality in kinematics, wear will not be an issue. To date, there are no data that mobile-bearing knee replacements will decrease wear complications as compared with round-on-round fixed designs. Wear is not an issue if the total knee replacement is done with a round-on-round design with a cobalt chrome femoral component, monoblock tibial component, and an all-polyethylene patella, all with cemented fixation.

Arthroplasty, Replacement, Knee↗

Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up.

BACKGROUND: Press-fit implantation of a porous-coated hemispheric acetabular component without screws is an option for primary total hip replacement. The purpose of the present study was to evaluate the results of this technique after an average duration of follow-up of ten years to determine if there was any loss of fixation or increase in osteolysis over time. METHODS: From June 1988 to November 1990, 132 primary total hip replacements were performed with a porous-coated socket that was implanted with use of a press-fit technique. Twenty-two hips were excluded because the patient had died or had been lost to follow-up, leaving 110 hips (103 patients) available for inclusion in the study after an average duration of follow-up of 10.2 +/- 1.0 years. The average age of the patients at the time of operation was 60.7 years (range, 23.7 to 86.2 years). Radiographs were evaluated with regard to initial gaps, radiolucent lines, migration, polyethylene wear, and osteolysis. Kaplan-Meier survivorship analysis was performed to calculate the rate of survival of the acetabular component. RESULTS: One hip (0.9%) had revision of the socket because of aseptic loosening, and four hips (4%) had revision of a stable socket. With the numbers available, the presence of gaps on the initial postoperative radiographs was not associated with the occurrence of radiolucent lines (p = 0.039). Pelvic osteolysis was seen in four hips, with an average time to radiographic appearance of six years. Increased wear was directly related to an abduction angle of >40 degrees. The twelve-year survival rate was 99.1% with revision because of failure of fixation of the metal shell as the end point, 95.3% with revision for any reason as the end point, and 79.6% with exchange of the liner as the end point. CONCLUSIONS: The fixation of this press-fit socket did not deteriorate over time and was associated with a low rate of osteolysis. The most common reasons for reoperation were wear and dissociation of the polyethylene insert.