Search PubMed⌕ Search

Biomedical subjects

L Krishnan

Publications and source records attributed to L Krishnan.

76 records · Page 5Linked to original sources

Anesthesia for caesarean section and immediate neonatal outcome.

Seventy-eight parturient mothers undergoing elective caesarean section were studied with regard to the immediate neonatal outcome in those receiving general and spinal anesthesia. All mothers were of grade I anesthesia risk, were term and had singleton appropriate for gestational age babies. There was no difference in fetal acid base chemistry in the two groups. Babies delivered after general anesthesia appeared relatively depressed requiring more free flow oxygen and bag and mask ventilation though one minute Apgar scores showed no significant difference in either group. Induction delivery intervals were longer in the spinal group but it was not associated with more morbidity. Uterine incision delivery intervals were very small in both groups and no meaningful conclusion could be drawn as regards effect on the newborn. A plea is made for more frequent use of spinal anesthesia considering its many postnatal advantages.

Acid-Base Equilibrium↗

Breast conservation therapy with tumor bed irradiation alone in a selected group of patients with stage I breast cancer.

Radiotherapy after breast-conserving surgery increases local control. We tested the feasibility of limited surgery with tumor bed irradiation only with 192Ir in a selected group of patients with stage I breast cancer. Twenty-five breasts in 24 women more than 60 years old with low- or intermediate-grade stage I tumors were treated with placement of interstitial catheters at the time of lumpectomy and axillary node dissection. This procedure was followed by after-loading with low-dose 192Ir to deliver 20-25 Gy to the tumor bed over 24-48 hours. There were neither local recurrences in the breast nor distant recurrences at a median follow-up of 47 months (range 25-90 months). Cosmetic appearance ranged from very good to excellent. There were no long-term complications. It is feasible to treat a select group of patients with tumor bed irradiation, using relatively low doses of interstitial irradiation, with excellent local control and no significant morbidity.

Aged↗

Effect of silicone gel breast prosthesis on electron and photon dose distributions.

The effect of a silicone gel breast prosthesis on the absorbed dose distribution of 9-20 MeV electron beams and 1.25-15 MV photon beams was studied. Compared to water measurements, at depths smaller than the practical range of the electron beams, the central axis depth dose values below the prosthesis were lower for all energies by as much as 3.5%. However, at depths near the practical range, the central axis depth dose values for the prosthesis were greater than that of water by as much as 33%. Since this occurs near the end of the electron range, the resultant difference may not be clinically significant. Results of the effect of breast prosthesis on photon depth dose distributions reveal that no clinically significant perturbation is produced by the breast prosthesis using Co-60, 6- and 15-MV radiations.

Breast Neoplasms↗