[Free abortion--limited "right" to abortion].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to L Jacobsson.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
For the Philips SL75/5, we have noticed that the performance of the beam (e.g. the hump) varies with the settings of the magnetron frequency and the gantry angle. This study investigated these changes and the optimum magnetron frequency setting was determined. The relation between the relative absorbed dose measured by the accelerator and the relative absorbed dose measured for different amounts of the hump in the centre of the beam was found. Results from a model and from measured values were compared. The beam was studied for different gantry angles and for different adjustments of the beam servo systems. The profiles obtained showed some variations, but were reduced when optimal adjustments of the servos were performed.
The aim of this study was to investigate the therapeutic efficacy of 211At-labelled monoclonal antibody given intraperitoneally to nude mice with intraperitoneal growth of a human ovarian cancer cell line. Female nude mice were inoculated intraperitoneally with 1 x 10(7) cells of the human ovarian cancer cell line NIH:OVCAR 3. After about two weeks they were injected with the 211At-labelled specific monoclonal antibody MOv18 intraperitoneally. For comparison, other groups of mice were given the same labelled antibody intravenously, 211At-labelled unspecific antibody C242 intraperitoneally or unalbelled MOv18 intraperitoneally. Six weeks later the animals were sacrificed and the occurrence of tumour and ascites was determined. When the mice were treated with 211At-labelled MOv18 intraperitoneally 9 out of 10 were apparently free of both ascites and tumour compared to none of the mice given unlabelled antibody. 211At-labelled MOv18 given intravenously or 211At-labelled unspecific antibody given intraperitoneally were less effective. Regional radioimmunotherapy with the alpa-emitter 211Astatine seems to be an effective treatment of nude mice with intraperitoneally growing human ovarian cancer. Hopefully this treatment can be given in an adjuvant setting to women with minimal residual ovarian cancer in the future.
BACKGROUND: The aim of this study was to perform various 211At irradiations of importance for the evaluation of 211At-radioimmunotherapy, and compare the effect with that of low linear energy transfer (LET) radiation. MATERIALS AND METHODS: All irradiations were performed on low-concentration single-cell suspensions. Growth assays using 96-well plates were used to estimate apparent cell survival. Centrifuge tube filters were used to estimate the cell uptake and binding of 211At. RESULTS: A relative biological effect (RBE) of 12 +/- 2 (Colo-205) and 5.3 +/- 0.7 (OVCAR-3) was found from 211At-albumin irradiations. There was a 174 +/- 28 times higher free 211At concentration in the cell fraction than in the surrounding medium. For 211At-MAb, an 8,000-30,000 times higher concentration in the cell fraction was achieved, compared to the medium. Corrected for the uptake, an average of 31 +/- 2 ([211At]-astatine) or 26 +/- 5 ([211At]-MAb) decays per cell were required for 37% survival of Colo-205 cells. An average of 19 +/- 3 decays ([211At]-astatine) were required per OVCAR-3 cell. CONCLUSIONS: Cell uptake and binding of 211At was unexpectedly high, possibly favouring its therapeutic use. The binding is probably to the cell surface. The RBE is 5.3 +/- 0.7 for OVCAR-3 and 12 +/- 2 for Colo-205 cells.
Cell growth kinetics following Astatine-211 (211At, alpha-particle emitter) and photon irradiation were studied for the human colorectal cell line Colo-205. A growth assay using 96-well plates was chosen. The growth kinetics could be simulated by assuming certain fractions of cells with various proliferative capacities, i.e. from none up to 5 cell doublings, in addition to the defined survivors with remaining unlimited clonogenic capacity. No significant difference in cell growth characteristics was seen between 211At and photon irradiation. The cell doubling time, as calculated from the increment in optical density, was compared with the results from BrdU experiments in the early phases of growth (Tpot = 18.5 +/- 0.6 h for LDR (low dose rate) photon irradiated and 20.3 +/- 0.8 hours for sham-irradiated cells 40-45 hours post-irradiation) confirming the transient accelerated growth of irradiated cells. No statistically significant difference in growth was found between LDR, MDR (medium dose rate) and HDR (high dose rate) photon irradiation.
The purpose of the present study was to compare the therapeutic efficacy of the alpha-emitter Astatine-211 with the beta-emitter Iodine-131 bound to the specific monoclonal antibody MOv18. The measurements were performed in an ovarian cancer cell line (NIH:OVCAR 3) growing intraperitoneally in nude mice. Two weeks after the intraperitoneal inoculation of 1 x 10(7) cells of the human ovarian cancer cell line NIH:OVCAR-3 twenty mice were treated intraperitoneally with the specific monoclonal antibody MOv-18 labelled with either 211At (310-400 kBq) or 131I (5100-6200 kBq). The pharmacokinetics and biodistribution of labelled antibody in tumour-free animals were studied and the resulting bone marrow dose was estimated. When the mice were treated with 211At-labelled antibody 9 out of 10 mice were free of macro- and microscopic tumour compared to 3 out of 10 when Iodine-131 was used. The equivalent dose to the bone marrow was 2.4-3.1 Sv from 211At- and 3.4-4.1 Sv from 131I-irradiation. The therapeutic efficacy of 211At-labelled specific antibody is very good and, at approximately equivalent bone marrow doses, better than that of 131I.