Mass of left ventricular myocardium estimated with dynamic spatial reconstructor.

Using the Dynamic Spatial Reconstructor (DSR), a unique multiple X-ray source, high-repetition-rate CAT scanner, we estimated left ventricular (LV) myocardial volume and chamber volume of eight dogs ranging from 2.5 to 32.5 kg. Dogs were given subcutaneous morphine (3 mg/kg) and anesthetized with intravenous pentobarbital sodium (22 mg/kg). A bolus of 1 ml/kg body wt contrast medium was injected into the superior vena cava and 60/s scans repeated over 7 s were performed. Each 0.0167-s scan generated image data for 120 1.8-mm-thick transverse slices, in the dextro and levo phases of the angiograms. Retrospective reformatting of the scan data was used to generate images of thin slices perpendicular to the aortoapical axis of the LV. The LV muscle and chamber volumes were estimated from their outlines in each imaged slice using a manually operated trackball interfaced to a computer. Values of the LV muscle ranged from 18.0 to 146.8 cm3 by DSR and showed a good correlation with the postmortem values (r = 0.99, y = 0.94x + 4.1). Ratios of volume of the myocardium to chamber volume ranged from 1.19 to 3.10.

Animals↗

Subtraction gated computed tomography with the dynamic spatial reconstructor: simultaneous evaluation of left and right heart from single right-sided bolus contrast medium injection.

Three-dimensional (3-D) dynamic computed tomography of the heart with the dynamic spatial reconstructor (DSR) is being used for studies of cardiovascular function. Formerly, continuous infusion of bilateral bolus injections of contrast medium were required to visualize both sides of the heart simultaneously. The DSR was used to circumvent many of the drawbacks of these methods. In anesthetized dogs a bolus of 1 ml/kg body weight contrast medium was injected into the superior vena cava and 60/s scans were performed during the dextro- and levophases of the resulting angiogram. The recorded scan data were used to generate successive volume (3-D) images with a scan aperture time of 0.06 s each. Each scanned cardiac cycle was thus represented by sequential volume images with either the right or left chambers opacified. Matching equal time intervals from the R wave of the electrocardiogram, the volume images of the left heart phase were digitally subtracted (voxel for voxel) from the images of the right heart phase, with all resulting negative voxel values set to zero. Only the contrast enhanced right ventricle (RV) chamber remained in the subtraction images, whose brightness was then scaled to match the brightness of the opacified left ventricle (LV). The modified RV phase images were then added to the LV phase images. The resulting volume images contain equally enhanced LV and RV chambers and can be used for retrospective analysis, including display of static and dynamic oblique planar images. Verification of the accuracy of this technique was made by estimation of LV muscle mass in five dogs. Dynamic spatial reconstructor estimates from subtracted gated images were compared with postmortem measurements. The correlation was 0.999 with a mean discrepancy of 2.3 +/- 0.4% SEM.

Animals↗

Noninvasive quantitative imaging of shape and volume of lungs.

The Dynamic Spatial Reconstructor (DSR) can be used to determine detailed structure-to-function relationships or organ systems in vivo. A basic index of lung structure (shape and dimensions) is total lung volume. We checked the accuracy with which in vivo lung volumes can be measured by comparing lung volume (air plus tissue) determined by DSR scanning with that determined by excision and water displacement. Six dogs (2.5-26 kg) under morphine-pentobarbital anesthesia were scanned supine or prone at functional residual capacity and/or total lung capacity. With the trachea clamped at the lung volume scanned, a lethal dose of pentobarbital was administered, the lung excised, and its volume determined by water displacement. In vivo scan data were used to reconstruct adjacent 0.9-mm-thick transverse sections over the entire axial extent of the thorax. A three-dimensional surface-detection algorithm was used to generate shaded surface displays of the in situ lungs. The number of voxels (volume picture elements) of known dimensions contained within the three-dimensional image of the lung was summed to estimate total lung volume. Lung volumes calculated from the in vivo images ranged from -3.4 to +2.3% of the lung volume determined in vitro. The mean difference was 1.38 +/- 0.07% (SE). Regression analysis yielded an r value (correlation) of 1.00, a slope of 0.99, and an intercept of -4.35 ml. Multiple lung inflation steps scanned and analyzed in one dog showed similar accuracy. This technique is applicable to subjects with thorax dimensions up to 42 cm in cephalocaudal height and 39 cm in ventrodorsal and transverse diameters.

Animals↗

Dynamic volume imaging of moving organs.

The Dynamic Spatial Reconstructor system has been developed to dynamically (up to 60/sec) image the entire 3-D volume (up to 240 adjacent 1-mm-thick transverse sections) encompassing moving organs of the body, particularly the heart and lungs, or the circulation in any organ. This capability permits accurate regional and global measurements to be made of the important relationships between structure and function within and among these organs, which in turn facilitates achievement of new insights into the basic physiological processes of these organs, and promises increased sensitivity and specificity in the diagnosis of pathology that affects normal organ function. This article explains the biomedical and technological rationale for development of the DSR, describes the design concepts and practical operation of the system, and presents preliminary results obtained with the system, including initial data from one of the first patient studies.

Animals↗

Aortic dissection: review of value and limitations of two-dimensional echocardiography in a six-year experience.

The utility of transthoracic two-dimensional echocardiography in patients with aortic dissection was assessed by retrospective analysis in 67 patients: 31 patients with DeBakey type I, 21 patients with type II, 10 patients with type III, and five patients with false-positive diagnoses. Aortic dissection was correctly identified by two-dimensional echocardiography in 49 patients; 13 had false-negative diagnoses. Therefore the sensitivity was 79%, and the positive predictive accuracy was 91%. Transthoracic two-dimensional echocardiography is a reasonable screening technique for diagnosis of aortic dissection.

Acute Disease↗