Dynamic left ventricular outflow tract obstruction in acute coronary syndromes.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to L J Sinak.
Explore the source record for details and available documents.
OBJECTIVE: To evaluate the treatment strategies for primary and secondary management of malignancy-related pericardial effusions. PATIENTS AND METHODS: Retrospective review of Mayo Clinic Rochester charts and external records of patients with pericardial effusion associated with malignant disease who required treatment between February 1979 and June 1998 was performed. Telephone interviews with patients, their families, or their physicians were conducted to determine the outcomes of treatment. Recurrence of pericardial effusion and survival were the main outcome measures. RESULTS: Of 1002 consecutive pericardiocenteses performed during the period under study, 341 were performed in 275 patients with confirmed malignant disease. Patients were followed up for a minimum of 190 days, unless death occurred first. Of 275 patients, recurrence of pericardial effusion or persistent drainage necessitated secondary management in 59 (43 of 118 simple pericardiocenteses, 16 of 139 pericardiocenteses with extended catheter drainage, and 0 of 18 pericardial surgery following temporizing pericardiocentesis). Recurrence was strongly and independently predicted by absence of pericardial catheter for extended drainage, large effusion size, and emergency procedures. Recurrence after secondary management occurred in 12 patients: 11 underwent successful pericardiocentesis with extended catheter drainage, and 1 had pericardial surgery. Median survival of the cohort was 135 days, and 26% survived the first year after diagnosis of pericardial effusion. Male sex, positive fluid cytology for malignant cells, lung cancer, and clinical presentation of tamponade or hemodynamic collapse were independently associated with poor survival. CONCLUSION: Echocardiographically guided pericardiocentesis with extended catheter drainage appears to be safe and effective for both primary and secondary management of pericardial effusion in patients with malignancy.
Dynamic left ventricular outflow tract (LVOT) obstruction has traditionally been associated with hypertrophic obstructive cardiomyopathy. Recently, acute dynamic LVOT obstruction has been described as a complication of myocardial infarction (MI). Herein the cases of 3 patients are described, all of whom presented with a systolic murmur and electrocardiographic evidence of MI. All 3 patients developed cardiogenic shock and were subsequently found by echocardiography to manifest an acute dynamic LVOT obstruction. Cardiogenic shock persisted until therapy was directed toward decreasing the degree of the dynamic LVOT obstruction. The treatment of acute coronary syndromes in the presence of a dynamic LVOT obstruction differs from the traditional treatment of acute coronary syndromes and includes the use of beta-blockers and alpha1-agonists, as well as the avoidance of therapies that aggravate the magnitude of the LVOT obstructive gradient, including nitrates, inotropic agents, and afterload reduction. The development of a systolic murmur in the setting of acute MI complicated by cardiogenic shock with only a small elevation in creatine kinase suggests the presence of a dynamic LVOT obstruction, as well as the classical mechanical complications of MI, namely, ventricular septal rupture and papillary muscle rupture. The presence of a dynamic LVOT obstruction is reliably detected by transthoracic echocardiography or by transesophageal echocardiography if transthoracic image quality is suboptimal.
Percutaneous pericardiocentesis was introduced during the 19th century and became a preferred technique for the management of pericardial effusion by the early 20th century. Until the era of two-dimensional echocardiographically guided pericardiocentesis, however, the procedure was essentially "blind," and serious complications were comparatively common, an outcome that resulted in an increased preference for surgical solutions. Because two-dimensional echocardiography facilitates direct visualization of cardiac structures and adjacent vital organs, percutaneous pericardiocentesis can be performed with minimal risk. Since its inception in 1979 (19 years ago), the echocardiographically guided pericardiocentesis technique has continued to evolve. Important procedural adaptations and modifications that optimize safety, simplicity, and patient comfort and minimize the recurrence of effusion have been defined and incorporated. This technique has been proved to be safe and effective. A detailed step-by-step description of the procedure and the necessary precautions to optimize success and safety is presented herein.
The sizing of aortic valve (AV) homografts for optimum function requires an accurate measurement of the aortic annulus. Typically, this measurement is obtained directly with sizers in the open aorta. We describe the use of intraoperative transesophageal echocardiography (IOTEE) to measure the aortic annulus and select the appropriate AV homograft before cardiopulmonary bypass and aortic cross-clamping. Thirty-two patients underwent AV homograft insertion between March 1993 and March 1996 and had IOTEE. There were 13 women and 19 men. Mean age was 58 +/- 14 years. IOTEE measurements were satisfactory in sizing in all patients, and no extraordinary surgical measures were necessary to insert the AV homografts. Early postoperative follow-up showed trivial or mild regurgitation of all homografts. Prebypass IOTEE is reliable in guiding the selection of optimal AV homografts.
Among 3,129 dobutamine stress echocardiographic studies, a hypertensive response, defined as systolic blood pressure (BP) > or = 220 mm Hg and/or diastolic BP > or = 110 mm Hg, occurred in 30 patients (1%). Patients with this response more often had a history of hypertension and had higher resting systolic and diastolic BP before dobutamine infusion.
Accelerated coronary artery disease is a common complication following orthotopic cardiac transplantation. The relationship between acute rejection and accelerated coronary artery disease remains unclear. While thallium-201 (201Tl) imaging has been advocated in the diagnosis of post-transplant coronary arteriopathy, other investigators have found little role for this technique in the evaluation of such patients. We undertook a retrospective review of 13 stress/rest (10 exercise, 2 dobutamine, 1 dipyridamole) and 2 rest/rest 201Tl single photon emission tomographic (SPET) imaging studies performed in seven patients post-cardiac transplantation (mean duration post transplantation = 2.5 years). Four of these patients had serial studies with an average interval between studies of 8.3 months (range 3-14 months). Coronary angiography was performed within 12 months of each 201Tl study (mean = 4.2 months). Using the coronary angiographic diagnostic criterion of > or = 50% stenosis in one or more vessels, one or more fixed or reversible segmental defects were found on 201Tl imaging with a sensitivity of 78% and specificity of 33%. When the angiographic criterion of > 70% stenosis in one or more vessels was used the sensitivity increased to 100%, and where reversible segments were diagnostic the sensitivity was 67% and the specificity range from 42 to 58%. Although based on a small sample of patients, these results suggest that use of appropriate test methods and interpretive criteria may improve the utility of 201Tl SPET myocardial imaging in the diagnosis of coronary artery disease in cardiac transplant patients. Limited specificity may reflect associated pathological processes in these patients, including rejection, oedema and focal inflammation.
BACKGROUND: In patients with mitral valve prolapse, spontaneous changes of the effective regurgitant orifice during systole are not well documented. Such changes can now be analyzed by use of the proximal isovelocity surface area method, but the changes raise concern about the reliability of this method for assessing overall severity of regurgitation in these patients. METHODS AND RESULTS: In a prospective study of 42 patients with mitral valve prolapse, the effective mitral regurgitant orifice was calculated at four phases of systole (early, mid, mid-late, and late) as the ratio of regurgitant flow to regurgitant velocity by use of the proximal isovelocity surface area method. Throughout systole, the effective regurgitant orifice increased significantly, from 32 +/- 27 mm2 in early systole to 41 +/- 27 in midsystole, 55 +/- 30 in mid-late systole, and 107 +/- 66 mm2 during late systole (P < .0001). Phasic regurgitant volume increased from early to mid-late systole but decreased in late systole. For quantitation of the overall effective regurgitant orifice, four approaches using the proximal isovelocity surface area were compared with simultaneously performed quantitative Doppler echocardiography (54 +/- 30 mm2) and quantitative two-dimensional echocardiography (51 +/- 29 mm2). All correlations were good (r > .95), but overestimation was considerable when the largest flow convergence was used (70 +/- 39 mm2; both P < .0001), significant when the simple mean of the four phases was used (59 +/- 36 mm2; P = .005 and P = .0007, respectively), mild when a weighted mean of the four phases was used (55 +/- 33 mm2; P = .41 and P = .01, respectively), and no overestimation was observed when the effective regurgitant orifice calculated at maximum regurgitant velocity was used (54 +/- 30 mm2; P = .29 and P = .17, respectively). CONCLUSIONS: Phasic changes of mitral regurgitation are observed in patients with mitral valve prolapse. The effective regurgitant orifice increases throughout systole. Regurgitant volume also increases initially but tends to decrease in late systole. These changes can lead to overestimation of the overall degree of regurgitation, but properly timed measurements made by use of the proximal isovelocity surface area method allow an accurate estimation of the overall effective regurgitant orifice.
Herein we describe a case of pyopneumopericardium that resulted from formation of an acquired esophagopericardial fistula in a patient with silent, benign esophageal ulcer disease. Atypical features on initial examination suggested congestive heart failure or a pneumonic process (or both). The delayed development of pneumopericardium disclosed on a chest roentgenogram led to the clinical recognition of the esophagopericardial fistula. Subsequent emergent pericardiocentesis relieved cardiac tamponade and enabled us to diagnose pyopneumopericardium. A radiographic contrast study with use of meglumine diatrizoate revealed the site of the fistula in the midesophagus. The esophagopericardial fistula was surgically closed, and our patient had a good final result. Formation of an esophagopericardial fistula is a relatively uncommon finding; of the 60 previously reported cases, only 10 patients have survived. As illustrated in the current case, early diagnosis and treatment, including pericardial drainage and intense antibiotic therapy followed by a well-planned operative closure of the fistula, are paramount for the successful management of esophagopericardial fistulas.
BACKGROUND: Transthoracic Doppler echocardiography examination has become an integral part of the investigations performed in patients with mitral valve prostheses. The limitations of the transthoracic approach are well documented. Transesophageal echocardiography provides a unique window for achieving a clear view of the mitral prosthesis. METHODS AND RESULTS: This study shows the usefulness of transesophageal echocardiography in clinical practice for assessment of patients with a mitral valve prosthesis. This technique demonstrated an abnormality in 48% of patients who had normal results on transthoracic examination. The overall sensitivity of transesophageal echocardiography was 96%. CONCLUSIONS: Transesophageal echocardiography constitutes an essential part of a comprehensive two-dimensional/Doppler echocardiographic examination in patients with suspected malfunction of mitral prostheses.
The feasibility, safety and clinical impact of transesophageal echocardiography were evaluated in 51 critically ill intensive care unit patients (28 men and 23 women; mean age 63 years) in whom transthoracic echocardiography was inadequate. At the time of transesophageal echocardiography, 30 patients (59%) were being mechanically ventilated. Transesophageal echocardiography was performed without significant complications in 49 patients (96%), and 2 patients with heart failure had worsening of hemodynamic and respiratory difficulties after insertion of the transesophageal probe. The most frequent indication, in 25 patients (49%), was unexplained hemodynamic instability. Other indications included evaluation of mitral regurgitation severity, prosthetic valvular dysfunction, endocarditis, aortic dissection and potential donor heart. In 30 patients (59%), transesophageal echocardiography identified cardiovascular problems that could not be clearly diagnosed by transthoracic echocardiography. In the remaining patients, transesophageal echocardiography permitted confident exclusion of suspected abnormalities because of its superior imaging qualities. Cardiac surgery was prompted by transesophageal echocardiographic findings in 12 patients (24%) and these findings were confirmed at operation in all. Therefore, transesophageal echocardiography can be safely performed and has a definite role in the diagnosis and expeditious management of critically ill cardiovascular patients.
Diastolic filling can be measured by radionuclide ventriculography with use of several techniques including those based on gated and list-mode acquisitions, the first-pass method, and the nuclear probe. Radionuclide ventriculography specifically assesses volumes, rates of volume change, and intervals during ventricular filling. Normal values for diastolic filling measurement vary depending on the individual radionuclide methods used and the age of the patient. Comparative studies of the radionuclide method with contrast angiographic and Doppler echocardiographic techniques for measuring diastole are discussed, and the advantages and disadvantages of the radionuclide techniques are explored. The role of radionuclide assessment of diastolic function in specific clinical examples of hypertrophic cardiomyopathy, hypertension, anthracycline-induced cardiomyopathy, and coronary artery disease is reviewed. Radionuclide ventriculography is an accurate and easily applicable procedure for studying left ventricular volume changes in diastole.
Left ventricular (LV) filling at rest was studied by radionuclide ventriculography using alternate R-wave gating in 42 patients (29 men, 13 women) who had a low likelihood of cardiac disease. LV filling measurements differed little between men and women. Age was correlated positively with atrial filling duration (r = 0.55), atrial filling duration fraction (r = 0.52) and atrial filling fraction (r = 0.56) and negatively with rapid filling fraction (r = -0.58). Age was not correlated with peak filling rate, time to peak filling rate and first-half filling fraction. The heart rate at rest was significantly negatively correlated with rapid (r = -0.62), slow (r = -0.81) and atrial (r = -0.72) filling durations, but not with isovolumic duration. The heart rate at rest was weakly positively correlated with peak filling rate in end-diastolic volume per second (r = 0.36) and negatively correlated with first-half filling fraction (r = -0.35). Systolic pressure at rest influenced atrial filling duration. LV ejection fraction and end-diastolic volume index were not correlated significantly with LV filling in relatively normal subjects.
In symptomatic severe aortic regurgitation, left ventricular diastolic pressure increases rapidly, often exceeding left atrial pressure in late diastole. This characteristic hemodynamic change should be reflected in the Doppler mitral inflow velocity, which is the direct result of the diastolic pressure difference between the left ventricle and left atrium. Mitral inflow velocity was obtained by pulsed wave Doppler echocardiography in 11 patients (6 men, 5 women: mean age 53 years) with severe symptomatic aortic regurgitation and compared with normal values from 11 sex- and age-matched control subjects. The following Doppler variables were determined: velocity of early filling wave (E), velocity of late filling wave due to atrial contraction (A), E to A ratio (E/A), deceleration time and pressure half-time. In severe aortic regurgitation, E and E/A (1.13 m/s and 3.3, respectively) were significantly higher (p less than 0.001) than normal (0.60 m/s and 1.5, respectively). Deceleration time and pressure half-time (117 and 34 ms, respectively) were significantly shorter (p less than 0.001) than normal (203 and 59 ms, respectively). Late filling wave velocity (A) was not statistically different in the two groups, although it tended to be lower in the patient group (0.39 versus 0.50 m/s). Diastolic mitral regurgitation was present in eight patients (73%). M-mode echocardiography of the mitral valve, performed in 10 patients, showed that only 3 (30%) had premature mitral valve closure. In symptomatic severe aortic regurgitation, the Doppler mitral inflow velocity pattern is characteristic, with increased early filling wave velocity (E) and early to late filling wave ratio (E/A) and decreased deceleration time of the E wave.(ABSTRACT TRUNCATED AT 250 WORDS)
The purpose of this study was to assess the role of MR imaging for evaluating suspected cardiac tumors or paracardiac masses involving the heart. Sixty-one patients with clinical or radiologic evidence of cardiac masses were imaged with ECG-gated MR at 1.5 T (22 patients) or 0.15 T (39 patients). Fifty-one patients had echocardiography previously. Among the tissue diagnoses were myxoma (six); fibroma, rhabdomyoma, plasma cell granuloma, lipomatous hypertrophy of the atrial septum, mesothelioma, and thymoma (two each); and leiomyosarcoma, lymphoma, metastatic carcinoid, melanoma, malignant fibrous histiocytoma, hemangiopericytoma, and lung spindle cell sarcoma (one each). MR imaging demonstrated masses in 50 patients (82%); they were centered in the heart in 32, pericardial in nine, and juxtacardiac in nine. MR imaging provided diagnostic information that affected clinical management or surgical planning in 53 patients (87%), including 11 (18%) in whom cardiac mass was excluded by MR. The ability to provide a global view of cardiac anatomy and other unique capabilities of MR imaging give the procedure an important role in the diagnosis and preoperative assessment of cardiac masses.
The dynamic spatial reconstructor, or DSR, is a unique high-speed volume-imaging x-ray scanner based on computed tomographic principles. In this report, we present data obtained from the first feasibility DSR studies of adult patients with heart disease. Information from three patients--one with hypertrophic obstructive cardiomyopathy, one with calcific aortic valvular disease, and one with a left ventricular aneurysm--is described in detail. The mean DSR scanning time for each patient was 20 seconds, and the mean total irradiation to the sternum was 15.3 R. Transverse cross sections were reconstructed and then retrospectively reformatted to provide operator-selected oblique sections in space (for example, long-axis and short-axis sections of the left ventricle), to follow these sections through time (such as from end-diastole through end-systole), and to create three-dimensional displays (for instance, of the left ventricular chamber). Unique quantitative measurements of structure and function were made by using these images. For generation of most imaging data, only one injection of contrast material into the right side of the heart is necessary. Clinically useful three-dimensional dynamic imaging data can be acquired from adult patients with heart disease by using the DSR. Compared with conventional angiocardiography, DSR studies can provide information with less x-ray exposure and fewer angiographic injections.
The Dynamic Spatial Reconstructor is a unique high speed volume imaging X-ray scanner based on computed tomographic principles. It has several potential advantages over conventional angiographic methods, including reduced invasion, reduced rate of false negative results and increased accuracy of measurements of structure and function. To evaluate the utility of the Dynamic Spatial Reconstructor in the investigation of congenital heart disease, scanning was performed in several pediatric patients with pulmonary valve atresia. Early results show that three-dimensional images of the cardiac chambers and intrathoracic vessels can be acquired and displayed with the system. All the information necessary for quantitative analysis of the pulmonary arteries can be obtained with a single scan involving injection of 0.6 to 2.0 cc/kg of contrast agent and radiation exposure of 0.54 to 0.95 rad/s over 5 to 8 seconds.
The Dynamic Spatial Reconstructor (DSR) is a high-temporal resolution, three-dimensional (3-D) X-ray scanning device based on computed tomography (CT) principles. It was designed for investigation of some problems inherent in current diagnostic imaging techniques, and to allow quantitative studies of cardiovascular structure and function. One of the research protocols in which DSR is currently used involves studying selected pediatric patients with complex congenital heart disease. Initial results show that 3-D dynamic images can be obtained from these patients with minimal invasiveness and that these images may provide useful diagnostic information.