Search PubMed⌕ Search

Biomedical subjects

Ken Hosoya

Publications and source records attributed to Ken Hosoya.

At least 37 records · Page 2Linked to original sources

Chromatographic molecular recognition for catechol-related compounds using thiacalix[4]arene as an effective selector.

Thiacalix[4]arene (5,11,17,23-tetra- tert-butyl-25,26,27,28-tetrahydroxy-2,8,14,20-tetrathiacalix[4]arene) is an amphiphilic molecule comprising four p-tert-butylphenol-like groups ortho-linked by single sulfur atoms. This molecule has a high electron density area owing to the close proximity of the hydroxyl groups and sulfur atoms. We studied the applicability of this interesting compound as a selector for high-performance liquid chromatography (HPLC) thereby presumably exploiting this feature. Firstly, uniformly sized polymer particles were prepared by using a multi-step swelling and polymerization method with ethylene glycol dimethacrylate (EDMA) as a cross-linker. Methacrylic acid (MAA) was introduced onto the surface of the resulting polymer particles through a new modification method. Thiacalix[4]arene was chemically bonded through the MAA group by using 1,4-dibromobutane as a spacer to reduce steric hindrance around the MAA and the polymer particle itself. The performance of the prepared polymer-based thiacalix[4]arene-modified stationary phase was evaluated with HPLC. Specific chromatographic retention behavior was observed for catechol relative to positional isomers of xylene, cresol, and benzene-diol. Catecholamine and catechol showed specific chromatographic retention behavior.

Catecholamines↗

Interval immobilization technique for recognition toward a highly hydrophilic cyanobacterium toxin.

A novel adsorption medium containing selective molecular recognition site for one of the powerful cyanobacterium toxins, Cylindrospermopsin (CYN) was developed using a special technique, namely interval immobilization technique. The adsorption medium was prepared using molecular assembly derived from an alternative-template molecule coupled with functional monomers for fixing the interval between the ionic functional groups in CYN. As results of liquid chromatographic evaluations, selective molecular recognition ability for CYN was observed as expected. Further studies proved that the association constant for CYN on this medium was slightly higher than that on blank polymer.

Adsorption↗

Determination of bisphenol A in environmental water at ultra-low level by high-performance liquid chromatography with an effective on-line pretreatment device.

We have developed a simple HPLC method for the microanalysis of bisphenol A (BPA), which is often contained in environmental water and is known as an endocrine disrupter. HPLC coupled with electrochemical detection requires a simpler procedure of pretreatment compared to GC-MS. In this study, we analyzed BPA using molecularly imprinted polymer as an on-line pretreatment device. This polymer has molecular recognition sites and provides specific selectivity in extraction process. Due to this effect, the detection limit obtained with this HPLC was 0.36 ng/l. This method applied to environmental water and purified water samples containing 2-70 ng/l of BPA successfully. Furthermore, UV detection was performed in some actual analyses.

Benzhydryl Compounds↗

Novel surface-modification techniques for polymer-based separation media. Stimulus-responsive phenomena based on double polymeric selectors.

A pair of polymeric selectors potentially responding to stimulation was introduced onto monosized porous polymer particles to be evaluated as a packing material for HPLC. Possible complexes formed between polyacrylamide (PAAm) and poly(methacrylic acid) (PMAA) were utilized as stimulus responsive polymeric selectors. Uniformly sized base polymer particle was prepared by multi-step swelling and polymerization method, while the introduction of PAAm and PMAA was done by newly invented modification technique. In this technique, a solvent in which both acrylamide (AAm) and methacrylic acid (MAA) monomers are soluble, but PAAm and PMAA are insoluble, was utilized as a modification medium. The polymer particle doubly modified with PAAm and PMAA was utilized as packing material for HPLC and the stimulus responses were evaluated by changing temperature or pH to check change of the slope of a Van't Hoff plot. By using water as a mobile phase, the expected inflection point of the Van't Hoff plot was observed at upper critical solution temperature (UCST) of the polymer complexes and the temperature responsive ability was observed. Moreover, pH responsive ability was studied by using buffer of either pH 4 or 10 as mobile phase. Slope of the plot was changed in buffer of pH 4, but no change of slope was observed in the buffer of pH 10.

Chromatography, High Pressure Liquid↗

Polymer-based adsorption medium prepared using a fragment imprinting technique for homologues of chlorinated bisphenol A produced in the environment.

A polymer-based adsorption medium having molecular recognition ability for homologues of chlorinated bisphenol A produced in environment was prepared using a fragment imprinting technique. 2,6-Dimethyl phenol was utilized as a pseudo-template molecule and the adsorption media prepared was evaluated by high performance liquid chromatography (HPLC) and solid-phase extraction (SPE). As results, the adsorption medium showed preferable chromatographic retention and specific adsorption ability for the chlorinated bisphenol As having chlorine substituents at 3,5-positions through fragment imprinting effect.

Adsorption↗

Simple and comprehensive two-dimensional reversed-phase HPLC using monolithic silica columns.

Simple and comprehensive two-dimensional (2D)-HPLC was studied in a reversed-phase mode using monolithic silica columns for second-dimension (2nd-D) separation. Every fraction from the first column, 15 cm long (4.6-mm i.d.), packed with fluoroalkylsilyl-bonded (FR) silica particles, was subjected to the separation in the 2nd-D using one or two octadecylsilylated (C(18)) monolithic silica columns (4.6-mm i.d., 3 cm). Monolithic silica columns in the 2nd-D were eluted at a flow rate of up to 10 mL/min with separation time of 30 s that meets the fractionation every 15-30 s at the first dimension (1st-D) operated at a flow rate of 0.4-0.8 mL/min. Three cases were studied. (1) In the simplest scheme of 2D-HPLC, effluent of the 1st-D was directly loaded into an injector loop of 2nd-D HPLC for 28 s, and 2 s was allowed for injection. (2) Two six-port valves each having a sample loop were used to hold the effluent of the 1st-D alternately for 30 s for one 2nd-D column to effect comprehensive 2D-HPLC without the loss of 1st-D effluent. (3) Two monolithic silica columns were used for 2nd-D by using a switching valve and two sets of 2nd-D chromatographs separating each fraction of the 1st-D effluent with the two 2nd-D columns alternately. In this case, two columns of the same stationary phase (C(18)) or different phases, C(18) and (pentabromobenzyloxy)propylsilyl-bonded (PBB), could be employed at the 2nd-D, although the latter needed two complementary runs. The systems produced peak capacity of approximately 1000 in approximately 60 min in cases 1 and 2 and in approximately 30 min in case 3. The three stationary phases, FR, C(18), and PBB, showed widely different selectivity from each other, making 2D separations possible. The simple and comprehensive 2D-HPLC utilizes the stability and high efficiency at high linear velocities of monolithic silica columns.

Journal Article↗

Recognition of hepatotoxic homologues of Microcystin using a combination of selective adsorption media.

Microcystin, a hepatotoxin produced by cyanobacteria, was chromatographically discriminated with newly prepared selective adsorption media. Since the name Microcystin refers to up to 70 different homologues, we have developed a novel technique to prepare selective recognition sites, based on the "Fragment Imprinting Effect". The homologues of Microcystin can be individually discriminated from each other by antigen-antibody assay as well as by C18-based HPLC. This is mainly due to differences in the three dimensional structure of Microcystin homologues; however, differences in toxicity are relatively small among the homologues. Therefore we have to measure the total amount of Microcystin homologues present to determine contamination by Microcystins. We have demonstrated the first group recognition for Microcystin homologues through combination of two different selective adsorption media prepared by a fragment imprinting technique.

Bacterial Toxins↗

Simple 2D-HPLC using a monolithic silica column for peptide separation.

Separation of peptides by fast and simple two-dimensional (2D)-HPLC was studied using a monolithic silica column as a second-dimension (2nd-D) column. Every fraction from the first column, 5 cm long (2.1 mm ID) packed with polymer-based cation exchange beads, was subjected to separation in the 2nd-D using an octadecylsilylated (C18) monolithic sillica column (4.6 mm ID, 2.5 cm). A capillary-type monolithic silica C18column (0.1 mm ID, 10 cm) was also employed as a 2nd-D column with split flow/injection. Effluentof the first dimension (1st-D) was directly loaded into an injector loop of 2nd-D HPLC. UV and MS detection were successfully carried out at high linear velocity of mobile phase at 2nd-D using flow splitting for the 4.6 mm ID 2nd-D column, or with directconnection of the capillary column to the MS interface. Two-minute fractionation inthe 1st-D, 118-second loading, and 2-second injection by the 2nd-D injector, allowed one minute for gradient separation in the 2nd-D, resulting in a maximum peak capacity of about 700 within 40 min. The use of a capillary column in solvent consumption and better MS detectability compared to a larger-sized column. This kind of fast and simple 2D-HPLC utilizing monolithic silica columns will be useful for the separation of complex mixtures in a short time.

Animals↗

How to utilize the true performance of monolithic silica columns.

Ways of utilizing the true separation efficiency of monolithic silica (MS) columns were studied. The true performance of MS columns, both regular-sized (rod-type clad with PEEK resin, 4.6 mm ID, 10 cm) and capillary sized (in 100 or 200 microm ID fused silica capillary, 25-140 cm) was evaluated by calculating the contribution of extra-column effects. HETP values of 7-9 microm were observed for solutes having retention factors (kvalues) of up to 4 for rod columns and up to 15 for a capillary column. The high permeability of MS columns allowed the use of long columns, with several connected together in the case of rod columns. Narrow-bore connectors gave good results. Peak variance caused by a column connector ranges from 50 to 70% of that caused by one rod-type column for up to three connectors or four columns in 80% methanol, but the addition of a 4th or 5th connector to add a 5th and 6th column, respectively, caused a much greater increase in peak variance, especially for long-retained solutes, which is greater than the variance caused by one rod column. Rod columns seem to show slightly lower efficiency at a pressure higher than 10 MPa or so. The use of acetonitrile-water as a mobile phase better preserved the ability of individual rod columns to generate up to 100,000 theoretical plates with 14 columns connected. Methods for eliminating extra-column effects in micro-HPLC were also studied. Split injection and on-column detection resulted in optimum performance. A long MS capillary measuring 140 cm produced 160,000 theoretical plates. The column efficiency of a capillary column was not affected by the pressure, showing advantages over the rod columns that exhibited peak broadening caused by connectors and pressure.

Chromatography, High Pressure Liquid↗

Toxicity recognition of hepatotoxin, homologues of microcystin with artificial trapping devices.

A hepatotoxin produced by cyanobacteria, microcystin (MC), was chromatographically discriminated with newly prepared artificial trapping devices. MC involves up to 70 kinds of homologues, and because homologues have similar toxicity, effective removal and analysis methods have been required. As a trapping device to discriminate MC, we have developed a novel technique for preparation of the "imprinted recognition site" into the crosslinked nano-scale structure, namely "Fragment Imprinting Effect." This technique is simple, and its possible application fields are relatively broad. We have demonstrated the recognition for MC homologues through the combination of two different artificial molecular recognition devices prepared through fragment imprinting technique.

Carcinogens↗

Improved detectability with a polymer-based trapping device in rapid HPLC analysis for ultra-low levels of bisphenol A (BPA) in environmental samples.

A new high-performance liquid chromatography (HPLC) method has been developed to detect ultra-low concentrations of bisphenol-A (BPA) (below 1 ng/L (ppt)) using column switching electrochemical detection (ECD). The results were superior to those obtained from manual pretreatment procedure with membrane stationary phase. BPA is inherently ubiquitous in the environment, including tools and solvents used for its analysis; to obtain meaningful results, therefore, the concentration of the overall BPA contamination must be below the detection limit for BPA using the analytical system. Therefore, purified water for preparing the standard BPA solution must be filtered with a hydrophobic membrane to suppress BPA background levels of contamination. In addition, we investigated methods for effectively preserving environmental water containing BPA. The addition of a small amount of ethylenediaminetetraacetic acid (EDTA) provided good recovery even after overnight storage. By employing these precautionary measures and procedures to reduce BPA contamination from the analytical procedure, we could accurately determine l(-10) ppt of BPA in environmental water samples using a column switching HPLC system.

Benzhydryl Compounds↗

Target-selective ion-exchange media for highly hydrophilic compounds: a possible solution by use of the "interval immobilization technique".

We prepared a crosslinked polymer as a separation and/or adsorption medium for CYN, as shown in Fig. 1. The polymers were evaluated by high-performance liquid chromatography (HPLC) and adsorption was examined under batch conditions. Results from detailed HPLC evaluation and measurement of the difference between the binding affinity for CYN and for other compounds showed the prepared polymer had specific recognition ability for CYN.

Alkaloids↗

Deuterium isotope effects on hydrophobic interactions: the importance of dispersion interactions in the hydrophobic phase.

Hydrogen/deuterium isotope effects on hydrophobic binding were examined by means of reversed-phase chromatographic separation of protiated and deuterated isotopologue pairs for a set of 10 nonpolar and low-polarity compounds with 10 stationary phases having alkyl and aryl groups bonded to the silica surface. It was found that protiated compounds bind to nonpolar moieties attached to silica more strongly than deuterated ones, demonstrating that the CH/CD bonds of the solutes are weakened or have less restricted motions when bound in the stationary phase compared with the aqueous solvent (mobile phase). The interactions responsible for binding have been further characterized by studies of the effects of changes in mobile phase composition, temperature dependence of binding, and QSRR (quantitative structure-chromatographic retention relationship) analysis, demonstrating the importance of enthalpic effects in binding and differentiation between the isotopologues. To explain our results showing the active role of the hydrophobic (stationary) phase we propose a plausible model that includes specific contributions from aromatic edge-to-face attractive interactions and attractive interactions of aliphatic groups with the pi clouds of aromatic groups present as the solute or in the stationary phase.

Chromatography, High Pressure Liquid↗

On-column concentration of bisphenol A with one-step removal of humic acids in water.

An efficient extraction method for bisphenol A from environmental water including contaminants was developed using surface selective localization of functional group, on a polymeric separation device. The polymer utilized in this study was prepared through a kind of molecular imprinting technique, namely fragment imprinting effect utilizing a pseudo-template molecule (p-tert.-butylphenol) instead of bisphenol A. The concentration of bisphenol A onto the polymer device prepared, up to 1000 times concentration from environmental water including contaminants (humic acids), was achieved very easily with interesting exclusion effect for humic acids. The results obtained in this study suggest that molecular imprinting with the pseudo-template molecule is quite an effective way for selective concentration of the diluted target molecule from other contaminants including similar functional group with the target molecule.

Benzhydryl Compounds↗

A possible purification method of DNAs' fragments from humic matters in soil extracts using novel stimulus responsive polymer adsorbent.

Novel stimulus responsive, uniformly sized polymer-based adsorbent was prepared for a possible purification method of DNAs from humic matters in soil extracts. The prepared polymer adsorbent has a pair of anion exchangeable and cation exchangeable polymeric selectors, which are reversibly responded by the changes of column temperature as well as pH of mobile phase. At pH 5, DNAs and humic matters were completely adsorbed on the polymer adsorbent at room temperature, while up to 90% of the adsorbed DNAs were released and recovered at 70 degrees C with no release of adsorbed humic matters. Cleaning up of the polymer adsorbent could be performed by washing the adsorbed humic matters with alkaline mobile phase (pH 9) to recover those and realize repeatable use of the adsorbent.

Adsorption↗

Preparation of uniformly sized molecularly imprinted polymers for phenolic compounds and their application to the assay of bisphenol A in river water.

Uniformly sized molecularly imprinted polymers, which can recognize bisphenol A (BPA), have been prepared by a multi-step swelling and polymerization method using BPA or a structurally related analogue of BPA [p-t-octylphenol (OP) or p-t-butylphenol (BP)] as the template molecule, 4-vinylpyridine as the functional monomer, and ethylene glycol dimethacrylate as the cross-linker. The BP-imprinted polymer showed higher molecular recognition ability for BPA than the OP-imprinted polymer. The BPA- and BP-imprinted polymers were applied for the assay of a trace amount of BPA in river water using column-switching HPLC with fluorescence detection: A BPA-imprinted polymer was used for removal of BPA from the pretreatment eluent as the trap column, and a BP-imprinted polymer was used for selective pretreatment and enrichment of BPA in river water as the pretreatment column. The calibration graph, constructed from peak area data plotted versus BPA concentration, was linear with a correlation coefficient of >0.999 in the concentration ranges of 25-1000 ppt. The limit of quantitation was 25 ppt with a 5-ml injection. The column-switching HPLC system was successfully applied for the assay of BPA in river water.

Benzhydryl Compounds↗

Novel surface modification of polymer-based separation media controlling separation selectivity, retentivity and generation of electroosmotic flow.

Uniformly sized packing materials based on synthetic polymer particles for high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC) have been prepared from polymerization mixtures containing methacrylic acid (MAA) as a functional monomer and by using a novel surface modification method. This "dispersion method" affords effectively modified separation media. Both the amount of MAA utilized in the preparation and reaction time affect the selectivity of chromatographic separation in both the HPLC and the CEC mode and electroosmotic flow. This detailed study revealed that the dispersion method effectively modified internal surface of macroporous separation media and, based on the amount of MAA introduced, exclusion mechanism for the separation of certain solutes could be observed.

Chromatography, High Pressure Liquid↗