[New materials for intraocular lenses].

The first intraocular lens implanted in a human eye 39 years then lenses ago, was made of polymethylmethacrylate (PMMA). Today this material is considered to be the standard, so every new type of material is compared to PMMA and must fulfil the requirements demanded of an intraocular implant today. Therefore, every attempt is made to use PMMA as the main structure while eliminating the disadvantageous characteristics even though they are minimal. Thus, the hydrophobic surface can be made more biocompatible by heparin-surface modification. In recent years, hydroxyethylmethacrylate (HEMA) and silicone have achieved a certain level of clinical importance. Another of the new materials is polycarbonate, which is still in the preclinical phase.

Benzhydryl Compounds↗

[Natural fluorescence of nuclear cataract lenses and melanomas of the eye].

For various reasons, it is desirable to have an objective cataract classification system that does not depend on either the opinion of the physician or the patient. Since both highly molecular protein aggregates and chromophores are formed in cataractous lenses, which fluoresce under suitable stimulation, we have developed a fluorescence apparatus that illuminates the lens with five monochromatic wavelengths between 350 and 500 nm in situ. The fluorescence spectrum is recorded up to 100 ms with an optical multi-channel analyzer. This fluorescence method is non-invasive and does not harm the eye; it also uses the native fluorophore. The set of fluorescence spectra obtained by this method describes the condition of the cataractous lens both quantitatively and qualitatively. Because of the sensitivity of the method, it can also be used to assess the disease objectively in the early stages and to test and determine the effectiveness of anti-cataract drugs. Another use was discovered by using the fluorescence measurements for the diagnosis of malignant melanomas. With this equipment, melanomas in the eye and the surrounding area can be diagnosed both rapidly and precisely.

Cataract↗

[Measuring lens opacity with the Opacity Lensmeter 701].

The Opacity Lensmeter 701 is a new instrument to quantify the opacity of the lens. The stray light scattered on the lens is measured and the amount depends on the density of the cataract. In 85 patients who underwent cataract surgery, both visual acuity and lens opacity were measured before surgery. After implantation of a lens, the visual acuity was tested again. There was a significant correlation between the opacity values and a cortical cataract. The correlation was lower (p = 0.0696) for eyes with nuclear cataracts. No correlation was found between a posterior subcapsular cataract and the opacity values measured.

Cataract↗

Comparison of intraocular pressure measurements with the Oculab Tono-Pen vs manometry in humans shortly after death.

We compared the Oculab Tono-Pen, a miniaturized Mackay-Marg tonometer, with a Statham membrane manometer in six humans (12 eyes), three to six hours after death. The intraocular pressure was changed in 5- to 10-mm Hg steps in a range between 0 and 60 mm Hg by an infusion system. The correlation coefficient of the relation of Tono-Pen readings vs manometrically determined intraocular pressures was .99. Compared to the manometer, the Tono-Pen gave a small underestimation of intraocular pressure above 17 mm Hg or overestimation below 17 mm Hg. The maximal deviation of the Tono-Pen readings from the manometer readings was 2.5 mm Hg. In our experience the correspondence between Tono-Pen and manometer readings was superior to the correspondence between the readings obtained with the original Mackay-Marg tonometer and manometry.

Aged↗

[Tono-pen, a new position-independent tonometer. Comparison with the Goldmann tonometer by applanation measurement].

A new hand-held tonometer, Tono-Pen (TP), was compared with the Goldmann tonometer (GM). The TP utilizes the operating principle of the Mackay-Marg tonometer. However, the TP is battery-operated, only 18 cm long, weighs only 60 g, and features electronic signal analysis (single-chip microprocessor) and a digital pressure display (mm Hg). In 108 subjects (216 eyes) presenting no ocular abnormalities, comparative tonometric measurements were performed in randomized order by two investigators (A: TP; B: GM). In 33 of these subjects (66 eyes), the intraocular pressure (IOP) was changed by means of a scleral suction-cup system. A total of 457 pairs of values was obtained in an IOP range extending continuously from 0 to 50 mm Hg. The relationship between TP (y axis) and GM (x axis) pressure readings is described exactly by a slightly curvilinear graph (y = 0.96x - 0.003x2 + 1.48; mm Hg). This may be approximated by a regression line with a slope of 0.8, a y intercept of 2.76 mm Hg and a standard deviation of 2.5 mm Hg (y values) in relation to the regression line. The mean values were 17.6 (TP) and 18.6 mm Hg (GM), which were not significantly different (P less than 0.05). The correlation coefficient amounted to 0.97. Below an IOP (GM) of 16 mm Hg, the TP slightly overestimated the IOP by a maximum of 1.48 mm Hg at GM = 0). Above 16 mm Hg, the TP increasingly underestimated, the IOP by a maximum of 8 mm Hg at GM = 50). Summing up, the TP is unique among hand-held tonometers in its miniaturization. In the low and physiological pressure range, there is an acceptable relationship between TP and GM readings. In the high pressure range, however, its readings deviate considerably from those of the tonometer.

Adult↗

[Behavior of the intraorbital pressure in different volumes].

Injection of 5 ml anesthetic solution into the retrobulbar space causes the eye to protrude and the intraorbital pressure to increase up to 14 Torr. Subsequent pressure on the eye leads to enophthalmos and causes the elevated retrobulbar pressure to drop. This pressure never exceeds the perfusion pressure within the retinal vessels.

Aged↗

[Corneal astigmatism following cataract operations].

Following a description of the surgical technique of wound opening and closure for planned extracapsular cataract extraction (ECCE) and posterior chamber lens implantation, the results, with regard to postoperative corneal astigmatism, are analyzed and discussed. In a prospective study a total of 720 cases was divided into 2 groups; the Terry surgical keratometer was used in Group I, while in Group II no postoperative measurements were performed. The results achieved in the two groups by 3 experienced surgeons were compared. Only one surgeon achieved keratometer readings which were statistically significantly lower in the early and late postoperative periods in Group I as compared to Group II. The percentage of cases with final corneal astigmatism of 2 D or less in the early and late postoperative period was higher in Group I - in which the Terry keratometer was used - than in Group II. The numerous factors influencing final postoperative corneal astigmatism are discussed.

Astigmatism↗

[Significance of fluorescence spectra for the evaluation of lens opacities].

The fluorescence spectra of nucleus and cortex material from human lenses obtained as a result of extracapsular cataract extraction were observed. With advancing cataract formation the fluorescence spectra changed in a very characteristic way. The changes in ascorbic acid were compared with those caused by cataract development. Clinical application of corresponding measuring instruments would appear to make sense.

Adult↗

Posterior chamber lenses with convex side posteriorly--the calculation of dioptric power and results.

Out of 2,000 calculated and implanted posterior chamber lenses with the convex side posteriorly we selected all patients with intraocular lenses having a power of 9 to 11 or 29 to 30 diopters. We found significant differences in the results of IOL-power calculation, using the SRK-formula or the theoretical mathematic formula. Using the distance between the corneal vertex and the first principal point of the plano convex lens as the anterior chamber depth we find that the theoretical formula is the most accurate in calculating the IOL-power of higher hypermetropic eyes.

Aged↗

Control of postoperative astigmatism.

The surgical technique of wound opening and closure for planned extracapsular cataract extraction (ECCE) and posterior chamber lens implantation is described and the final postoperative corneal astigmatism is analysed and discussed. A prospective study of 720 cases divided into 2 groups was undertaken; Group I using the Terry surgical keratometer and Group II not using the Terry Keratometer. Out of 3 surgeons, only one had statistically significant lower K-readings in the early and late postoperative periods in Group I compared to Group II. The percentage of cases with final corneal astigmatism of 2 diopters or less in the early and late postoperative period is higher in Group I than in Group II. The factors influencing final postoperative corneal astigmatism are discussed.

Astigmatism↗

[Nd-YAG laser capsulotomy in intraocular lenses with reversed optics].

From a clinico-anatomical point of view the implantation of IOLs with reversed optics approximates natural conditions and has many advantages. The distance between the endothelium or the pigment epithelium of the iris and the front surface of the lens is greater. The refracting surface of the lens is nearer to the nodal point and aniseikonia is reduced. However, it is still not known whether YAG laser treatment to open the posterior capsule is possible under these conditions. The present authors used the pulsed OPL3 neodymium-YAG laser ( Meditec ) to treat 45 eyes for secondary opacification of an intact posterior capsule after planned extracapsular cataract extraction. (A: 15 eyes with reversed-optic IOLs, B: 15 eyes with other types of IOL, C: 15 eyes with extracapsular aphakia). After performing a central capsulotomy with a mean of 44 shots, visual acuity increased immediately (mean improvement in visual acuity determined before and one week after YAG laser treatment - A:6 Snellen lines, B: 3 Snellen lines, C: 5 Snellen lines). In no eye was the post-laser visual acuity lower than before laser treatment. Even though the eyes were treated prophylactically with timolol 0.25% for 3 days, intraocular pressure - measured on the first postoperative day - increased insignificantly (mean: A: 1 mmHg, B and C: 2 mmHg). In 9 cases a mild iritis was observed, while 2 eyes had a hemorrhage of the iris vessels. Symptoms resolved within five days after laser treatment in all cases. The study demonstrates that Nd-YAG laser capsulotomy can be performed in patients with reversed optic IOLs without any disadvantage as compared to other types of IOL.

Aged↗